Interactive Patient Care – Barco Healthcare Division Content Locations of the Jumpers and Connectors ................................................... 22 Top View ............................................................................................... 22 Jumpers and DIP Switch Setting ................................................................... 22 Safety Precautions .........................................................................................
Interactive Patient Care – Barco Healthcare Division Preface Copyright This publication, including all photographs, illustrations and software, is protected under international copyright laws, with all rights reserved. No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written consent from BARCO.
Interactive Patient Care – Barco Healthcare Division However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the European Union (CE) directives if it has a CE marking. For computer systems to remain CE compliant, only CE-compliant parts may be used. Maintaining CE compliance also requires proper cable and cabling techniques.
Interactive Patient Care – Barco Healthcare Division development procedure and that all the new RoHS components and new manufacturing processes maintain the highest industry quality levels for which BARCO are renowned. The model selection criteria will be based on market demand. Vendors and suppliers will ensure that all designed components will be RoHS compliant. CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.
Interactive Patient Care – Barco Healthcare Division Safety Precautions 1. Read these safety instructions carefully. 2. Keep this User Manual for later reference. 3. Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not use liquid or spray detergents for cleaning. 4. For plug-in equipment, the power outlet socket must be located near the equipment and must be easily accessible. 5. Keep this equipment away from humidity. 6.
Interactive Patient Care – Barco Healthcare Division Technical Support and Assistance 1. For the most updated information of products, visit Barco website at www.barco.com. 2.
Interactive Patient Care – Barco Healthcare Division Conventions Used in this Manual Warning: Information about certain situations, which if not observed, can cause personal injury. This will prevent injury to you when performing a task. Caution: Information to avoid damaging components or losing data. Note: Provides additional information to complete a task easily CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.
Interactive Patient Care – Barco Healthcare Division Symbol Glossary There are some symbols marks on user manual, label, carton and product, each symbol has its purpose, please take notice the symbol identification before use. Network The system support 10/100/1000 Mbps Ethernet connection. Line out 3.5mm earphone jack supports line out signal.
Interactive Patient Care – Barco Healthcare Division Ordering Information The following information below provides ordering information. JAO 15 / ST156BIPC000 (P/N: 10Q0ST15600X1) 15.6” bedside terminal, Intel Bay Trail J1900 2.0GHz, resistive touch screen, 2GB DDR3L, 32GB MLC SSD, 13.56MHz RFID and smart card reader JAO18/ ST185DIPC000 (P/N: 10Q0ST18500X1) 18.5” bedside terminal, Intel Bay Trail J1900 2.0GHz, PCAP touch screen, 2GB DDR3L, 32GB MLC SSD, 13.
Interactive Patient Care – Barco Healthcare Division Flat Panel by Resistive Touch Screen Product Introduction With 1x GbE/ HDMI input/ 5x USB ports Built in speaker/ microphone/ 2x line out JAO15 Overview JAO 15 is designed to serve as a Point of Care (POC) and Point of Information terminal (POI) within healthcare applications.
Interactive Patient Care – Barco Healthcare Division Specification Panel - LED size: 15.6”, 16:9 - Resolution: 1366x768 - Luminance: 300 cd/m2 - Contrast ratio: 500 - LED color: 16.7M - Viewing Angle: 80(U) 80(D) 80(L) 80(R) - Backlight: LED Touch Screen - 5 wire Resistive touch - Light transmission: 78% - Interface: USB System - CPU: On-board Intel® Celeron® J1900, 2.
Interactive Patient Care – Barco Healthcare Division - Certified module BOINTE PE809-AA - Support 802.11 b/g/n - Support BT 4.
Interactive Patient Care – Barco Healthcare Division JAO18 Overview JAO 18 is designed to serve as a Point of Care (POC) and Point of Information terminal (POI) within healthcare applications. Manufactured using anti-bacterial plastics, the terminals provide a host of interactive healthcare applications providing secure access to Electronic Medical Records (EMR) and innovative triple-play solutions (web, IPTV, VoIP) for patient entertainment. Key Features 16:9 18.
Interactive Patient Care – Barco Healthcare Division Specification Panel - LED size: 18.5”, 16:9 - Resolution: 1366X768 - Luminance: 300 cd/m2 - Contrast ratio: 1000 - LED color: 16.7M - Viewing Angle: 80(U) 80(D) 85(L) 85(R) - Backlight: LED Touch Screen - PCAP touch - Light transmission: 87% - Interface: USB System - CPU: On-board Intel® Celeron® J1900, 2.
Interactive Patient Care – Barco Healthcare Division - Certified module BOINTE PE809-AA - Support 802.11 b/g/n - Support BT 4.0 - Power input: 100-240V~ 1.5-0.75A 50-60Hz - Power Output: 19VDC, 4.
Interactive Patient Care – Barco Healthcare Division IO introduction Front side Camera 720p camera with white LED RFID and smart card reader 13.56MHz RFID and smart card reader. RFID tag also readable while parking in smart card reader slot Power Key Touch icon input. Long press 5 seconds to turn on panel backlight; long press 10 seconds to reset or power off system. CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.
Interactive Patient Care – Barco Healthcare Division Back side Microphone Built in digital microphone HDD service door Lock with Torx screws, use for SSD replacement Speaker Built in stereo speaker RAM and miniPCIe service door Lock with Torx screws, use for RAM replacement or install extension module Rear IO 19V DC input Service call USB LAN connect to PSU connect to back end service system (intra network) with 4 wire signal pin 3x USB 2.
Interactive Patient Care – Barco Healthcare Division Mechanical Dimensions JAO15 JAO18 CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division Jumpers and Connectors This chapter describes how to set the jumpers and connectors on the motherboard. metal object. Static electricity can damage many of the electronic components. Humid environments tend to have less static electricity than dry environments. A grounding strap is warranted whenever danger of static Before you Begin Ensure you have a stable, clean working environment. Dust and dirt can get into components and cause a malfunction.
Interactive Patient Care – Barco Healthcare Division Leave all components inside the static-proof packaging that they shipped with until they are ready for installation. Use correct screws and do not over tighten screws. Jumper Setting A jumper is the simplest kind of electric switch. It consists of two metal pins and a cap. When setting the jumpers, ensure that the jumper caps are placed on the correct pins. When the jumper cap is placed on both pins, the jumper is short.
Interactive Patient Care – Barco Healthcare Division Locations of the Jumpers and Connectors Top View Jumpers and DIP Switch Setting CMOS Clear Select Connector type: 1x3 3-pin header, 2.54mm pitch Connector location: JBIOS1 Pin Settings 1-2 ON Normal 2-3 ON Clear BIOS CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.
Interactive Patient Care – Barco Healthcare Division Connector Pin Definition External I/O Interface 19V DC Power Input HDMI Input Port Connector type: 5.5mm DC jack Connector type: HDMI Female connector Pin Definition Pin Definition 1 TMDS Data2+ 11 TMDS Clock Shield 2 TMDS Data2 Shield 12 TMDS Clock– 3 TMDS Data2– 13 CEC 4 TMDS Data1+ 14 N.
Interactive Patient Care – Barco Healthcare Division Service Call connector USB Connector type: 6 pin RJ 11 connector Pin Definition 1 VCC5 2 USB 0- 3 USB 0+ Pin Definition 4 GND 2 Service call + 3 Service call - 4 Handset LED + 5 Handset LED - Service call CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.
Interactive Patient Care – Barco Healthcare Division LAN Ports Connector type: RJ45 port with LEDs ACT Status LINK Status Yellow blinking Data activity Steady green 1000M link Off No activity Steady orange 100M link Off 10M or no link Pin Definition Pin Definition 1 LAN M0+ 5 LAN M2- 2 LAN M0- 6 LAN M1- 3 LAN M1+ 7 LAN M3+ 4 LAN M2+ 8 LAN M3- Pin Definition 1 LOUT_R 2 JD 3 NC 4 LOUT_L 5 GND 6 GND Line-out Jack Connector type: 3.
Interactive Patient Care – Barco Healthcare Division Internal Connectors SATA Connector location: SATA1 Pin Signal Pin Signal S1 GND S2 SATA_TX0P S3 SATA_TX0N S4 GND S5 SATA_RX0N S6 SATA_RX0P S7 GND P1 VCC3 P2 VCC3 P3 VCC3 P4 GND P5 GND P6 GND P7 VCC5 P8 VCC5 P9 VCC5 P10 GND P11 NC P12 GND P13 VCC12 P14 VCC12 P15 VCC12 CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.
Interactive Patient Care – Barco Healthcare Division Mini-PCIe Slot Connector location: CN2 Pin Signal Pin Signal Pin Signal Pin Signal 1 WAKE0# 2 3.3V_MINI 27 GND 28 +1.5V_MINI 3 NC 4 GND 29 GND 30 SMB_CLK 5 NC 6 1.5V_MINI 31 PCIE_TX3- 32 SMB_DAT 7 PCIE_CLKREQ 8 NC 33 PCIE_TX3+ 34 GND 9 GND 10 NC 35 GND 36 USB- 11 GPP_CLK1- 12 NC 37 GND 38 USB+ 13 GPP_CLK1+ 14 NC 39 +3.3V_MINI 40 GND 15 GND 16 NC 41 +3.
Interactive Patient Care – Barco Healthcare Division System Setup Prior to removing the chassis cover, make sure the unit’s power is off and disconnected from the power sources to prevent electric shock or system damage. Replace SATA Disk To fully disengage the power to the unit, please disconnect the power cord from the AC inlet 1. Loose the screw of HDD service door. 2. Remove current SATA and replace with new one.
Interactive Patient Care – Barco Healthcare Division Replace RAM 1. Loose the screw of RAM service door. 2. Remove DDR3L RAM module and replace with new one. 3. CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division System Mounting accessory pack, there are 4 M4 screws. Length of screw teeth should be 5mm. Screw should be fasten to back cover by 8KG torque. There are different mount types to fix system in bracket or arm. In system CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.