AMM215WTTP LCD Color Display User Guide ENABLING BRIGHT OUTCOMES
Barco, Inc. 3059 Premiere Parkway, Suite 400, Duluth, GA 30097, USA www.barco.com/en/support www.barco.com Registered office: Barco NV President Kennedypark 35, 8500 Kortrijk, Belgium www.barco.com/en/support www.barco.
Table of contents 1 Welcome!.......................................................................................................................................................................................................... 5 1.1 1.2 What’s in the box ...............................................................................................................................................................................6 Product Overview ..........................................................
R5911667 /03 AMM215WTTP
1 Welcome! Introduction Thank you for choosing this AMM215WTTP! For future reference, record the serial number of your display below. The serial number is located on the back of the display. Serial number Warnings, cautions, notes and tips There are four levels of precautionary or advisory statements that may be used in this user guide. In descending order of importance, they are: WARNING: Describes hazards or dangers that might result in personal injury or death.
Welcome! 1.1 What’s in the box Overview Make sure the following items are present when you unpack the box: • • • • • • • • • • • AMM215WTTP LCD display Power cord VGA signal cable USB cable (A to B) DVI-D cable DC power supply Quick start guide Manual Multilingual documentation disc Cable cover screw AC-Adaptor (part number: BPM050S12F09 (Bridgepower)) Your system provider may offer alternative cords or cables depending on the installation requirement and local geography issues.
Welcome! Bottom View VGA DVI RJ-Type DC IN USB Image 1–2 Flat Panel Mounting Physical Mounting Interface by VESA This monitor confirms to the VESA Flat Panel Mounting Physical Mounting Interface standard which defines a mounting interface for flat panel monitors, and corresponding with the standards of flat panel monitor mounting devices, such as wall and table arms.
Welcome! 8 R5911667 /03 AMM215WTTP
Installation 2 WARNING: Read all the important safety information before installing and operating your monitor. Please refer to the dedicated chapter in this user guide. WARNING: Sufficient expertise is required to install this equipment. All devices and complete setup must be tested before taking into operation. CAUTION: When the display is assembled in the medical system, take care of the fixation of all cables, to avoid unwanted detachment. CAUTION: The equipment is not intended to be sterilized.
Installation 2.1 Workspace To prepare a suitable workspace Before you carefully unpack your monitor, prepare a suitable workspace You need: • • • a stable and level surface a grounded power outlet an area which is relatively free of glare from sunlight or other sources of bright light The monitor is cooled by natural convection (it has no fan). For optimum performance, do not block the cooling vents. 2.
Installation Image 2–1 R5911667 /03 AMM215WTTP 11
Installation 2.4 Connecting the Display How to set up the Display 1. Be sure all equipment is turned off. 2. Connect the DC plug to the power connector on the monitor and the other end into an electrical outlet. 3. Connect the D-SUB or DVI cable from the display’s D-SUB or DVI input connector to the D-SUB or DVI connector of your host computer and tighten the screws. 4. Connect the USB cable from the USB port of your display to the USB port of your computer. 5. Configure the touch screen.
Daily Operation 3 R5911667 /03 AMM215WTTP 13
Daily Operation 3.1 Recommendations for daily operation To avoid image retention Permanent burn-in may occur from the following: • • • Displaying color bar or static images repeatedly or for a long period of time. Using the unit repeatedly in a high temperature/ high humidity environment. Continuously displaying an image smaller than the monitor. To reduce the risk of burn-in, it is recommended to turn off the power of the unit, and reduce the brightness when the unit is not in use. 3.
Advanced Operation 4 R5911667 /03 AMM215WTTP 15
Advanced Operation 4.
Advanced Operation Mode Resolution Horizontal frequency (KHz) Vertical frequency (Hz) WXGA+ 1440 x 900 70.60 75 WSXGA+ 1680 x 1050 65.20 60 WSXGA+ 1680 x 1050 (VGA only) 82.30 75 WXGA 1366 x 768 47.712 60 WSXGA+ 1920 x 1080 67.50 60 4.3 Touch Screen Driver Installation Overview The AMM215WTTP is available with USB connections. The touch driver is located on the enclosed CD-ROM for these operating systems: VISTA, XP, 2000, CE, XP Embedded, Linux, Apple Mac OS.
Advanced Operation 2. Be sure the USB cable is connected to the computer 3.
Cleaning your display 5 R5911667 /03 AMM215WTTP 19
Cleaning your display 5.1 Cleaning instructions To clean the display Turn off the product before cleaning. No specific liquid or chemical is necessary when cleaning this LCD monitor. However, we suggest to clean the monitor with non-abrasive cloths and cleaning solutions used in hospitals to clean similar equipment. CAUTION: Do not apply excessive pressure on the LCD. CAUTION: To clean the display, do not spray liquid cleaners directly to the screen.
Troubleshooting 6 R5911667 /03 AMM215WTTP 21
Troubleshooting 6.1 Troubleshooting list To diagnose a problem Before sending your LCD display for servicing, check the troubleshooting list below to see if you can selfdiagnose the problem. Problem No image Partial image or incorrectly displayed image Image has vertical flickering line bars Image is unstable and flickering Image is scrolling Vague image (characters and graphics) Remedy Check that all the I/O and power connectors and correctly and well connected.
Important Information 7 R5911667 /03 AMM215WTTP 23
Important Information 7.1 Safety Information General recommendations • • • • • • • • Read the operating manual thoroughly and be familiar with the content, prior to using this equipment. Do not place the monitor, or any other heavy object, on the power cord to prevent fire or electrical shock from damage to the power cord. Power cord is used as a disconnection device. To de-energize equipment, disconnect the power cord. ME equipment should be placed easily powered off place.
Important Information Water and moisture • • • Never expose the display to rain or moisture. Degree of protection against the ingress of water: IPX1 compliance. AC adapter is not protected against water. Do not expose AC adapter to water. Ventilation • • • Do not cover the slots or openings of the monitor for proper heat dissipation. Always put the monitor in a place where there is adequate ventilation to prevent internal heat buildup. Do not block the monitor cooling vents.
Important Information This symbol on the product indicates that, under the European Directive 2012/19/EU governing waste from electrical and electronic equipment, this product must not be disposed of with other municipal waste. Please dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment.
Important Information 部件名稱 有害物質 鉛 Pb o 汞 Hg o 鎘 Cd o 六價鉻 Cr6+ o 多溴聯苯 PBB o 多溴二苯醚 PBDE o 軟體(CD等) 本表格依据SJ/T 11364的規定編制。 o: 表示该有害物質在該部件所有均質材料中的含量均在 GB/T 26572規定的限量要求以下。 X: 表示该有害物質至少在該部件的某一均材料中的含量超出GB/T26572規定的限量要求,對于所有顯示X的情 況, 本公司按照EU RoHS采用了容許的豁免指標。 根据 SJ/T 11364SJ/T 11364 SJ/T 11364 SJ/T 11364 SJ/T 11364 要求 , 本公司電子信息產品均注明以下污 染控 制标志.
Important Information Contra-indications This display is not intended to be used for direct diagnosis and therapeutic interventional radiology. Intended users Surgical displays are intended to be used by trained medical practitioners. Notice to the user and/or patient Any serious incident that has occurred in relation to the device should be reported to the manufacturer and the competent authority of the Member State in which the user and/or patient is established.
Important Information WARNING: Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.
Important Information Immunity test IEC 60601 test levels Power frequency (50/60 Hz) magnetic field IEC 61000-4-8 30 A/m 50 Hz or 60 Hz Voltage dips, short interruptions and voltage variations on power supply input lines IEC 61000-4-11 0 % UT ; 0,5 cycle At 0° . 45°, 90°, 135°, 180°, 225°, 270°, and 315° q) 0% UT; 1 cycle and 70 % UT ; 25/30 cycles Single phase: at 0° 0 % UT ; 250/300 cycle Compliance level UT is the A.C. mains voltage prior to application of the test level.
Important Information Immunity test Conducted RF IEC610004-6 Radiated RF IEC 61000-43 IEC 60601 test levels Compliance level 3V 0,15 MHz - 80 MHz 6V in ISM and amateur radio bands between 0,15 MHz and 80 MHz 80 % AM at 1 kHz 10 V/m 80 MHz - 2,7 GHz 80% AM at 1 kHz Electromagnetic environment – guidance Portable and mobile RF communications equipment should be used no closer to any part of the AMM215WTTP, including cables than the recommended separation distance calculated from the equation applicable t
Important Information Recommended Separation Distances Between Portable and Mobile RF Communications Equipment and the AMM215WTTP system The AMM215WTTP system is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
Important Information MD SN UDI Indicates this is a Medical Device. Indicates the device serial number. Indicates the Unique Device Identifier. Warning: dangerous voltage Caution Consult the Instructions For Use. Indicates this device must not be thrown in the trash but must be recycled, according to the European WEEE (Waste Electrical and Electronic Equipment) directive. Indicates Direct Current (DC).
Important Information IPX1 Tested to comply with IP (Ingression Protection) Rating Atmospheric pressure: 500 hPa ~1,060 hPa 1060 hPa 500 hPa Humidity: 10 ~ 90% RH 90 % 10 % Storage temperature: -20° C — 60° C +60°C -20°C Refer to instruction manual / booklet Note: On ME EQUIPMENT “Follow instructions for use” 7.7 Warranty Responsibility Barco, Inc.
Important Information unauthorized disassembly, repair or modification; normal wear and tear; tampering by anyone other than an BARCO engineer or an BARCO Authorized Service Center (ASC); the use of supplies, consumable items and conditions beyond the control of BARCO, such as common carrier provided equipment and/or facilities; operation of BARCO product in excess of the specifications.
Important Information THE LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE OR JURISDICTION TO JURISDICTION. 7.8 Legal disclaimer Disclaimer notice Although every attempt has been made to achieve technical accuracy in this document, we assume no responsibility for errors that may be found. Our goal is to provide you with the most accurate and usable documentation possible; if you discover errors, please let us know.
Barco, Inc. 3059 Premiere Parkway, Suite 400 Duluth, GA 30097 USA R5911667 /03 | 2021-04-14 www.barco.