Getting Started Guide

1/6 2/6
Tools
DD 200 pro diamond core rig, vacuum base (P/N
on Hilti website: Item #3423950).
Ø130mm crown
10-litre portable water supply tank (P/N on Hilti
website: Item #365595) + Extra portable Water Tank
Vacuum Cleaner
App Activation Tool on Android mobile phone
RFID device (DOTR-900 from KCTNS) and selfie
stick
Materials
Mortar Mapegrout SV
Sensor installation position
Installation step by step
U-Spot DUO installation
U-Spot DUO installation
!
Getting started
Activation Tool installed on Android Smartphone (contact
support@urbiotica.com to get the latest version)
Activation Tool username and password available
Check that the network is configured in the Fastprk web platform
Ensure that the LoRa coverage is ensured in the sensors’ installation area
1. Make a hole 75 mm deep with a crown of 130 mm Ø.
2. Clean and dry the hole from dust, debris and water.
3. Prepare the Mapegrout SV fast mortar.
4. For each of the sensors, fill the hole with enough mortar to ensure
that the mortar takes up all the space between the hole and the sensor
(approximately 250ml per sensor). For optimal installation, a surplus of
mortar must spill over the hole when the sensor is inserted
5. Clean the mortar that overflowed from the edge of the hole.
6. Place a weight over the sensor and wait until dries. We recommend
letting the mortar dry for 15 minutes.
Sensor edge must be in line with the pavement
Sensor should be completely flush within the
pavement
7. Take pictures of the installed sensors, about 70% - 80% of the
sensors.
8. Take a picture (if possible panoramic) to ensure there are no cars
nearby.
9. Activate the sensor with the Activation tool following the procedure
describe in the next pages.

Summary of content (3 pages)