L-400_835996_0803_E.p65 1 Manual Identification Systems BIS Compact Processor BIS L-400-035-00_-_ _-S115 Deutsch – bitte wenden! 2 No. 835 996 D/E • Edition 0803 Specifications subject to charge. Replaces edition 0710. Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.F. Germany Phone +49 7158 173-0 Fax +49 7158 5010 balluff@balluff.de www.balluff.
L-400_835996_0803_E.p65 3 Table of Contents Safety Notes ............................................................................................................................... 4 Introduction BIS L-400 Identification System ........................................................................ 5/6 Basic knowledge for using the BIS L-400 Processor .............................................................. 7 Configuration ........................................................................
L-400_835996_0803_E.p65 5 Introduction BIS L-400 Identification System This manual is intended to guide the user in installing and commissioning the components in the BIS L-400 identification system, so that start-up time is reduced to an absolute minimum. The BIS L-400 identification system belongs to the category of Principle read-only, non-contacting systems.
L-400_835996_0803_E.p65 7 BIS L-400 Processor Basic knowledge for the application Data integrity with CRC_16 For applications which demand high security against incorrect data the CRC_16 procedure can be used. Here a check code is written to the data carrier which can be used at any time and anywhere to test for data integrity.
L-400_835996_0803_E.p65 9 Configuration Interface BIS L-400 In the first screen the transmission rate, number of data and stop bits as well as the parity type for the serial port are configured. The figure shows the factory default settings. . Additional settings are made in the screens illustrated on the following Operation mode The device can be operated in one of two modes: Terminal or Controller.
L-400_835996_0803_E.p65 11 Configuration CRC_16 data check BIS L-10_-05 ☞ If this parameter is set, the data from the data carrier are sent along with a 2-byte CRC_16 check sum. This leaves only 3 bytes of user data remaining. If a correct CRC_16 check sum is recognized, it will be output in bytes 1 and 2. If a CRC error is detected, 00 Hex, 00Hex is sent instead of the check sum. To use the CRC_16 procedure, the data carriers must first be initialized from the BIS L-60_ _ processor using the BISCOMRW.
L-400_835996_0803_E.p65 13 Protocol Sequence Controller mode A simple transmission protocol is used between the host controlling system and the processor. The following control characters are used: ASCII Hex Meaning 'ENQ' 05 The processor informs the host system that an event has occured. – Data carrier in front of the read head, data are ready. 'DLE' 10 The host system queries the current status or a current event. This is possible at any time.
L-400_835996_0803_E.p65 15 Error Messages Error numbers Error No. Hex ASCII Error description Cause 30 '0' no error 31 '1' No data carrier present No data carrier in the active zone of the read/write head. 45 'E' CRC error The CRC on the data carrier does not agree with the calculated CRC for the read data. 15 english 16 Timing Diagrams Reading the data without Reset When a data carrier enters the read zone of the processor, the latter sends the ASCII character 'ENQ'.
L-400_835996_0803_E.p65 17 BIS L-400 Installation Installation BIS L-400 When installing two BIS L-400 on a metal base, there is normally no mutual interference. If a metal frame is located in an unfavorable location, problems may result when reading out the data carriers. In this case the read distance will be reduced to 80 % of the maximum value.
L-400_835996_0803_E.p65 19 BIS L-400-035-001-_ _-S115 Installation Clear zone 30 ø100 Power 7.3 BIS L-200-03 TP 6.5 L 60 46 120 at v = 0 (static condition) Characteristic data by data carrier Center axis offset at a (installed in clear Read distance of: (mm) zone) distance (mm) 0-25 0-35 0-45 0-15 BIS L-200-03 / L-100-05 Speed [m/s] 15 0.4 BIS L-201-03 20 0.45 BIS L-202-03 27.5 0.6 BIS L-203-03 10 0.
L-400_835996_0803_E.p65 21 BIS L-400-035-003-_ _-S115 Installation Set screw Clear zone Cable length max. 20 m Cable length 50 cm Active surface Speeds (at standard setting data comparison counter = 2): Characteristic data by data carrier at v = 0 (static condition) Characteristic data Center axis offset by data carrier (installed in clear at a distance of: Read (mm) zone) distance (mm) 0-5 0-8 0-11 BIS L-203-03 / L-103-05 0 -11 ±6 ±4 ±2 BIS L-203-03 at read distance [mm] Speed [m/s] 5.
L-400_835996_0803_E.
L-400_835996_0803_E.p65 25 BIS L-400-035-00_-00-S115 Interface Information Interface V.24 / RS232 9 pin connector ➀ RTS connection (TP) allows TP display in the BISCOMRW.EXE program. ➁ OUT TP switches to +24V when there is a data carrier in the capture zone. english 26 BIS L-400-035-00_-02-S115 Interface Information Do not change position of JP RS422 4-wire point-to-point Termination resistor * Galvanic isolation is recommended for the supply voltage and RS422 interface! Data line twisted pair.
L-400_835996_0803_E.p65 27 BIS L-400-035-00_-00-S115 Connection Diagrams Wiring the outputs OUT TP (only for RS232) Supply voltage: Output current: Voltage drop at 50 mA: DC 24 V +10% / –20% (incl. ripple) max. 200 mA < 1.5 V english 28 BIS L-400 Technical Data General data Housing Plastic (PBT) Temperature range Ambient temperature 0 °C to +60 °C Enclosure rating Enclosure rating IP 67 (only when assembled) Supply voltage Supply voltage Current consumption DC 24 V +10 % / –20 % (incl.
L-400_835996_0803_E.p65 29 BIS L-400 Ordering Information Part Numbers BIS L-400-035-00_-0_-S115 Balluff Identification System Series L Hardware type 400 = Plastic housing Software type 035 = Serial Hardware type 001 = Coil Ø 34 mm 002 = discharged read head module M18 (0.5 m cable) 003 = discharged read head module M12 (0.5 m cable) 004 = discharged read head module C-305 housing (0.
L-400_835996_0803_E.p65 31 Appendix, ASCII Table DeciControl Hex ASCII mal Code 0 00 Ctrl @ NUL DeciControl Hex ASCII mal Code 22 16 Ctrl V SYN DeciHex ASCII mal 44 2C , DeciHex ASCII mal 65 41 A DeciHex ASCII mal 86 56 V DeciHex ASCII mal 107 6B k 1 01 Ctrl A SOH 23 17 Ctrl W ETB 45 2D - 66 42 B 87 57 W 108 2 02 Ctrl B STX 24 18 Ctrl X CAN 46 2E .