About This Document This document introduces the installation and debugging steps of CW0100 outdoor CPE equipment, which is used for guiding installer to install CPE correctly. Copyright Notice BaiCells copyrights this specification. No part of this specification may be reproduced in any form or means, without the prior written consent of BaiCells. Disclaimer This specification is preliminary and is subject to change at any time without notice.
Contents 1. 2. 3. 4. 5. Installation Preparation ................................................................................................. 2 1.1 Out-of-Box Audit ...................................................................................................... 2 1.2 Installation Accessories .............................................................................................. 2 1.3 Installation Tools .............................................................................
Contents of Figure Figure 2-1 Appearance of CW0100.............................................................................. 5 Figure 2-2 Install on pole A........................................................................................... 7 Figure 2-3 Install on pole B .......................................................................................... 8 Figure 2-4 Mounting Hole of Install on Wall .................................................................
Contents of Table Table 2-1 CW0100 Interface and button ...................................................................... 5 Table 2-2 LED Indicators .............................................................................................. 6 Table 2-3 RF Specification ........................................................................................... 6 Table 3-1 Lightning Protection Demand of Cable ......................................................
1. Installation Preparation 1.1 Out-of-Box Audit Before opening the box, make sure the packaging cases are in good condition, undamaged and not soaked. During the unpacking, avoid potential damaging impacts from hits or excessive force. Check whether the material in the box is consistent with “Shipping List” and is in good condition and undamaged. Note: During the unpacking, if the outer package is damaged or soaked, stop unpacking and find the cause. Report the issue to the vendor.
Figure Name Shielded CAT5 twisted pair The length of the cable is tailored according situation of the installation site. Plastic tie Grounding wire 1.3 Installation Tools The following tools are needed during the installation.
Wrench 1.4 Electroprobe Electric soldering iron Ladder Installation Environment According to “Reconnaissance Report”, check whether the external environment of installation site is ready. 1.5 Safety Protection Construction personnel must conform to “Construction Safety Specification”, wearing safety protection guard, such as safety belt, safety helmet, gloves, and wrist strap, and so on.
2. Equipment Installation 2.1 Appearance The appearance of CW0100 outdoor CPE is smart, the dimension of CPE is 245mm x 135mm x 42mm, the weights of CPE is 600g. The appearance is shown in Figure 2-1. Figure 2-1 Appearance of CW0100 CW0100 CPE support installing on pole or installing on wall. The following introduces the two ways separately. Caution: The direction of CPE cable exit end must be down. 2.
2.3 LED Indicators Table 2-2 LED Indicators LED Name PWR LTE Signal LAN 2.
2.5 Install on Pole Installing on pole have three methods: traditional on pole, telegraph on pole and iron on tower. Traditional on pole: Required diameter of the pole is 25mm to 45mm. Telegraph on pole: If the pole is telegraph, you need to install a pole that length is over 700mm and diameter is 25mm to 45mm as the mounting bracket. Iron on tower: If CPE is installed on iron tower, you need to choose vertical direction angle iron as the mounting bracket. The length is about 25mm to 45mm.
Figure 2-3 Install on pole B Fasten the screw using screw driver 2.6 Install on Wall When CW0100 installs on wall, the installation method is as follows: On the wall, fix two big head screw which distance is 52mm, and then hang the CPE on the big head screw.
3. Wire Connection 3.1 Make Ethernet Cable Connector CW0100 outdoor CPE need to use shielded CAT5 twisted pair, the operation steps of making connector is as follows:: 1. Before making the RJ-45 shielded connector, strip the outer Jacket of the twisted pair about 30mm using crimping tool, which is shown in Figure 3-1. Figure 3-1 Strip Shielded Twisted Pair 2. Separate the metal net, wire of cable and aluminum foil layer of twisted pair, as shown in Figure 3-2.
Figure 3-3 Cut off the aluminum foil layer of twisted pair 4. The mode of connection is standard straight through cable. The color order is white/orange, orange, white/green, blue, white/blue, green, white/brown, brown, which is shown in Figure 3-4. The color order is important to get corrected. Figure 3-4 Color Order 5. Insert the eight wires into the line card according to the color order, shorten them to a suitable length (about 12 mm) using diagonal pliers, as shown in Figure 3-5.
Figure 3-6 Insert line card into Connector 7. Crimping the cable using crimper, as shown in Figure 3-7. Figure 3-7 Crimping connector 8. Impact the metal part of the shielded connector tail with the metal net shielded layer of the Ethernet cable using nipper pliers, as shown in Figure 3-8.
9. Cut off the redundant part of metal net using diagonal pliers, as shown in Figure 3-9. Figure 3-9 Cut off the redundant part 10. After the completion of shielded connector making, as shown in Figure 3-10. Repeat all the steps and wire color on the other end of the cable. Figure 3-10 Completion of shielded connector 11. Test whether the cable is normal using Ethernet cable tester.
is normal. In the tester, if eight signal indicator and grounding indicator flash green in turn, it indicates that the Ethernet cable is normal. If any signal indicator is red or yellow, it indicates that there is circuit break or bad contact. You need to make a new connector again. 3.2 1. Connect Ethernet Cable Connect the shielded cable to WAN interface of CPE, as shown in Figure 3-11. Figure 3-11 Connect Cable 1 2. After connecting the Ethernet cable, cover the slide of CPE, as shown in Figure 3-12.
Figure 3-12 Connect Cable 2 3. Connect to POE power. One end of the cable connect to CPE and the other end connect to POE power. Fix the cable on the pole using plastic tie close to CPE about 20cm, preventing the damage of the cable waggling with the wind. It is recommended that the cable is fixed by plastic tie at intervals of 50cm until POE power. If the length of outdoor is too long, you need to protect the cable with metal shielded flexible sleeve. 3.
Figure 3-13 POE power Mode 3.4 Lightning Protection of Cable It need to use shielded cable and ensure the grounding of two ends of equipment. If the opposite equipment has plastic enclosure, which cannot be grounding. In this situation, the shielded cable function is decreased largely. If its available, it is recommended that Ethernet cable and power cable pass through metal sleeve to ground separately. And they cannot be in a same metal sleeve.
4. Power on Detection 4.1 Detection Item Power on detection includes the following four items: Ethernet port working status CPE configuration check CPE access test CPE parameter record 4.2 Ethernet Port Working Status After CPE powered on, waiting for 2 minutes, connect the Ethernet port of PC to POE adaptor. The CW0100 CPE default IP address is 192.168.1.1. Set the IP address of PC is 192.168.1.2, ensure that the Ethernet indicator get light and ping CPE IP address normal. 4.
5. Regulatory Compliance FCC Compliance This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
IC Compliance This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.
Appendix A FAQ CPE is unable to power on Check whether POE power is connected normal. Check whether the Ethernet cable is damaged and wire order is correct. CPE service is unable to running Check whether it is correct that the network normal configuration of CPE. Check whether the CPE have connected to LTE network. CPE receive download signal weak If external antenna is used, check whether antenna feed system have connected normal. (The standing wave measuring can be used.