User's Manual

Technical
Brief
BadgerMeter,Inc.
®
RTR
®
- Extended
Range Pit ORION
®
Recordall
®
Transmitter Register for
Extended Range Pit ORION
®
RTR-T-37
5-02
DESCRIPTION
APPLICATIONS: The Badger
®
RTR
®
Extended Range Pit ORION
®
RF
system is designed for water meter pit or vault installations that are subject
to flooding or submergence. The assembled system consists of the
Recordall
®
Transmitter Register (RTR
®
) and the Extended Range Pit
ORION Module. The RTR is factory wired to the end cap assembly for
maximum reliability; the Extended Range Pit ORION is bottom mounted
thru a drilled hole in the meter pit lid.
The assembled RTR Extended Range Pit ORION is designed to
communicate with Badger interrogation devices, including handheld or
mobile.
OPERATION: The RTR provides a digital signal from Badger Meter's
patented piezoelectric solid-state switch. This signal has the characteristics
of an open drain Field Effect Transistor (FET) and has no electrical
contacts to stick, wear or corrode. It is fully compatible with the input
circuitry of the Extended Range Pit ORION Module. The Extended Range
Pit ORION Module uses the RF bubble-up (broadcast) mode.
RESOLUTION: Digital output from the RTR has resolution of 1/10th of
the register test circle. Output resolution of the Extended Range Pit
ORION Module may vary with meter size. The resolution table on the back
of this technical brief lists output resolution for all ORION meter applications.
LEAK DETECTION: The Orion system provides optional leak detection
notification when the meter is read. The system reports leak detection
when a two hour window of no usage is found within a 24 hour time period.
The system automatically resets when the next two hour window of no
usage is found.
MOUNTING: The RTR uses a bayonet connection compatible with all
Recordall
®
Disc, Turbo, Compound and Fire Series meters. A TORX
®
seal
screw is provided to allow positioning and to secure the RTR to the meter
body in a tamper resistant mode. The RTR can be removed from the meter
without disrupting service or disconnecting the Extended Range Pit
ORION. The RTR is factory wired to the Extended Range Pit ORION
Module.
For best performance, the Extended Range Pit ORION is mounted
through the drilled hole in the lid, attached to the lid, and programmed
by the utility in the field. If the Extended Range Pit ORION system is
mounted below the lid (not through the drilled hole) reduced
performance will result.
MAGNETIC DRIVE: Direct drive, high-strength, magnetic coupling through
the meter body to the wetted magnet provides reliable and dependable
register coupling.
SEALED REGISTER: The RTR local register consists of a six-digit
straight-reading mechanical odometer totalizer, a 360° test circle with
sweep hand, and a flow finder to detect leaks. The register gearing is self-
lubricating, thermoplastic to minimize friction and provide long, reliable
life. Permanent sealing eliminates moisture, dirt, and other contaminants.
TAMPER-PROOF FEATURES: Removal of the RTR from the meter can
be minimized by using a tamper resistant TORX seal screw. TORX seal
screws are provided as standard accessories with the RTR. Optional
tamper detection seal wire screws are also available.
CUT WIRE TAMPER INDICATION: The Extended Range Pit ORION has
the capability to detect a tamper should it exist. Proper setup in ORION
Reading System software needed.
CONSTRUCTION: The housing of the RTR is constructed of a tempered
glass lens top and a copper alloy metal bottom. Internal construction
materials are thermoplastic for long-life and high reliability. The integrity
of the adhesive seal joining the glass top to the metal base provide
unmatched protection in water meter applications. A corrosion and
tamper resistant TORX seal screw is provided to secure the RTR to the
meter. The shroud assembly is polycarbonate.
The housing of the Extended Range Pit ORION is constructed of a
polycarbonate material.
TEMPERATURE: The operating range of the RTR is -40°C to 49°C (-40°F
to 120°F). The operating range of the Extended Range Pit ORION is -
40°C to 60°C (-40°F to 140°F). The water meter should not be subjected
to temperatures below freezing.
SPECIFICATIONS
Transmitter/Register Straight reading, permanently sealed,
magnetic drive
Unit of Measure U.S. Gallons, Cubic Feet, Cubic Meters,
clearly identified on register face
Number Wheels Six with 3/16" high numerals
Namel font type
Test Circle 360° circle with ten major increments with
ten divisions each
Weight 9 Ounces
Humidity 0% to 100% Condensing
Signal Characteristics Open Drain (FET)
Visual Resolution 1/100th of Test Circle
Electronic Resolution 1/10th of Test Circle
Typical Signal Duration 15 ms to 75 ms @ 25°C (77°F)
8 ms to 75 ms over operating temperature
range at 67 µA
On State Resistance 7.5 Ohms @ 25°C (77°F)
Power Source External
Maximum Switching 30 VDC @ 1 mA @ 25°C (77°F)
Battery on Pit ORION (2) 3.6V 2.4 Ahr Lithium Batteries
See Badger Technical Brief RTR-T-05 for RTR
®
specifications.