High Station Count Controller A B-hyve® Pro Connected Device Beta unit Installation and Operation Guide MODEL: HSC-1600-M
SYMBOL DEFINITION FCC AND IC STATEMENT This device complies with Part 15 of the FCC Rules and Industry Canada license exempt RSS standards. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Safety Information Warning: A circuit breaker or cutoff switch shall be installed in the wiring to isolate the controller Warning: Date and time on the controller are maintained by a long-life lithium battery. This battery shall be disposed of in accordance with local regulations. Contents SYMBOL DEFINITION ....................................................................................................................... 2 FCC AND IC STATEMENT ...........................................................
Manual Operation ..................................................................................................................... 11 Sensor Alarm Bypass ................................................................................................................. 11 Fault Alarms .............................................................................................................................. 11 VIEW FLOW ....................................................................................
Set a station as a Master Valve ................................................................................................. 17 Set NC/NO valve operation ....................................................................................................... 17 Reset menu ................................................................................................................................... 18 Reset Programs .....................................................................................
Welcome to the Hydro-Rain Family Thank you for your purchase of the weather-based, smart irrigation, High Station Count Controller! We understand that time is money, so our products are designed to save you time. Whether it is programming a controller, installing the system, or adjusting the system our products go together faster and easier. HSC Controller Smart. Adaptable. Formidable. Hydro-Rain has focused on making products faster and easier to use.
HSC Hardpoints Physical touchpoints to use the HSC: 1. Ethernet Connection Used for a hardwire internet connection 2. USB Power Port A charger your phone or tablet. 3. Display Shows alerts, current status, upcoming watering events, and remaining runtime 4. Buttons Look to the display screen to see what the buttons does. The function of these buttons’ changes based on the screen you are in, or what the controller is doing. 5.
1 1 1. Release button for easy removal 2. Activity lights shows water status 3. Terminal Screw 4. Common or grounding terminal 2 3 2 3 4 4 • • • • Before installing or removing modules turn off power using the on/off switch. DO NOT pull the modules out until the release button has been fully depressed. The number plate on the 8-station module is keyed so that the stations can to be identified by the controller quickly.
Menu Overview: STOP STATIONS SETUP Pump & Master Valves RESET FLOW NETWORKING DIAGNOSTICS MANUAL System Off Setup Language Programs Flow Assignment System Update Fault Log Station Pause Irrigation Set Station as Master Valve Time Select Pump or Master Valve Set Station as Master Valve Flow Manual Learn Flow Solenoid Diagnostics Program Stop All Irrigation Flow Assignment Date NC/NO valve selection Programs & Flow Flow Delay Current Connection Status Wi-Fi Reset Test Timed Of
Setup When the system first powers on it will run several checks. You may see several messages on the screen and notice that alerts may activate. This is normal. Once the system checks have completed you can pair to the HSC and begin the setup process. Setting Day and Time During the pairing and setup process the HSC will automatically set the day and time. If the day or time needs to be adjusted Press Main Menu button and scroll to Setup and select time or date.
If a fault was detected it is recorded in the log. o At the controller Press the triangle with an exclamation point to see the log file. VIEW FLOW Use the B-hvye Pro App When flow meters are installed and configured, Flow will show on the Home screen.
Functions and Definitions Stop Menu In the Stop Menu you can find most options to stop, delay or pause watering events System Off • Stops all irrigation and places controller in off mode • Can be used at end of season to stop all watering Pause Interrupts whatever is currently running, until either Resume is pressed, or 30 minutes have passed (count down is shown on screen). Anything running will be resumed where it left off and run for its remaining time.
Selective Stop Allows user to selectively stop what is watering. The controller is still in automatic irrigation mode and will continue watering all other programs or stations. Once stopped the station or program will not water until watering is resumed. The "Play" button can be pressed to resume watering, and cancel selective stop, at any time. Faults and delays will display over selective stop information Station Menu Station Setup Only connected stations appear in this screen.
Set Normally Closed / Normally Open valve operation The PMV Settings Screen allows user to define if station is normally closed or normally open. All valves are considered normally closed, until changed. If a valve is set as normally open this screen can change it back to Normally Closed. The “##” flashes until you press up or down to selects a number. Entering 0 exits to prior screen and you can only cycle through connected stations.
• • • • • • • Spanish (Latin America) Portuguese (Brazil) Portuguese (European) French (European) Italian (European) German (European) Polish (European) Set Time If you have connected the HSC, the time is automatically set. To manually set or change the time following the instructions below. The “HH” will flash until you press up or down to select a number. As you cycle through 1-12, the system should automatically switch between AM and PM.
The “DD” should flash until you press up or down to select a number. If the button is held for 3 seconds the days advance by 5-day intervals. The “YYYY” should flash until you press up or down to select a number. If the button is held for 3 seconds the years advance by 5-minute intervals. Once you select a number the system will wait 5 seconds before moving back to the Month. Press enter to select the time and return to the previous screen.
Reset menu We have different levels of resets available based on different needs. Reset Programs Reset Flow Reset Programs and Flow Factory Reset System Update Programs Flow Firmware Saved Log / History Saved Reset Saved Reset Reset Reset Saved Saved Saved Saved Reset Reset Reset Reset Saved Saved Saved Updated Saved Reset Programs Reset Programs by clearing all program information.
System Update Updates Firmware, saves all Flow data, saves all Program data, saves historical data, Updates current firmware version, Returns to home screen once complete Current Connections Lists current connections and their status • • • • • Wi-Fi 900 MHz Bluetooth Cellular Ethernet Wi-Fi Reset If the Wi-Fi has changed, or you wish to disconnect from it, this screen allows you to clear the stored Wi-Fi information.
• • Short for a failing solenoid Open for a broken wire or poor contact Pump, Master Valve Log If a P/MV is connected anytime it activates a record is made. You can scroll through the activity; the most recent activity is at the top of the list. Flow Log When a Flow meter is connected the system automatically records the average flow from readings taken during the middle third of the scheduled runtime. This log displays that reading along with the PMV, station, program, day, and time.
connected stations. The station can run for a predetermined time (2 minutes default). You can also stop the test or return to prior menu.
Station Program Runtime Program 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 Start Watering Time Days A B C D Terminal T1 T2 T3 T4 T5 T6 MASTER VALVES STATION NC / # NO FLOW ASSIGNMENT
36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63