Control board ONE-C USER MANUAL
COAT015197 – Instruction manual ONE-C – EN 13.10.2020 19.04.2022 Date A B Indice Création Ajout FCC statement Description Note: The illustrations in this document are non-contractual.
COAT015197 – Instruction manual ONE-C – EN Contents 1 PRESENTATION ON THE INTERFACE ................................................................................................... 4 GENERAL INTERFACE .................................................................................................................................4 INPUTS/OUTPUTS .....................................................................................................................................5 1.2.
COAT015197 – Instruction manual ONE-C – EN 1 Presentation on the interface 1.1 General interface SD Modbus Encoder RTU Card Digital inputs (x8) Relay Power Brake 230Vac Analogue (or digital) inputs (x4) Transistor outputs 24Vdc (x6) User interface Ethernet RJ45 Analogue Output 0-10V Additional Serial link 24Vdc input User interface Screen Buttons LEDs 4 Dry contact relay outputs Three-phase (x6) Motor 230Vac Description 4x20 character backlit viewing screen.
COAT015197 – Instruction manual ONE-C – EN 1.2 Inputs/outputs 1.2.
COAT015197 – Instruction manual ONE-C – EN 1.2.2 Default assignment of the inputs/outputs I1 I2 I3 I4 I5 I6 I7 I8 Open command (NO) Close command (NO) Magnetic safety loop (NC) Safety infrared cell (or ultrasound detection) (NC) no. 1 Safety infrared cell (or ultrasound detection) (NC) no.
COAT015197 – Instruction manual ONE-C – EN 2 Controls and viewing 2.1 Local controls: Control Key ▼ Function Local close command (from the "Information" and "Inputs-Outputs" screens) Local open command (from the "Information" and "Inputs-Outputs" screens) Display of the advanced settings Display of the input/output statuses Main menu Key ▲ ESC key (2s) ENTER key (2s) ESC + ENTER (3s) 2.2 Viewing The screen as well as the viewing LEDs allow you to view the current status of the barrier. 2.2.
COAT015197 – Instruction manual ONE-C – EN • Information" screen (default screen): This display is the default screen, it indicates useful information for the installer: ====Informations==== Fr: -7 Hz Cycles: 125 BARRIER CLOSED - - Frequency of the motor (in Hz): this corresponds to the frequency of the current injected into the motor. This frequency is positive in the opening direction and negative in the closing direction.
COAT015197 – Instruction manual ONE-C – EN • Status of the inputs/outputs" screen (hold "ENTER" for 2s): To access the screen for viewing the status of the inputs/outputs, press and hold the « ENTER » button for 2s.
COAT015197 – Instruction manual ONE-C – EN 3 3.1 Messages and safety component activation Status messages of the barrier: Here are the various status messages of the barrier (last line on the information screen): Message « BARRIER OPEN » « BARRIER OPEN 15S » « BARRIER CLOSED » « OPENNING » « CLOSING » « DETECTION LOOP » « DETECTION CELL » « BARRIER UNHINGED » « CRANK MISSING » 3.
COAT015197 – Instruction manual ONE-C – EN 4 Main menu: To go to the main menu, press the "ESC" and "ENTER" keys simultaneously for 3s. 4.1 Choice of the user: Before accessing the main menu, you must first select the user.
COAT015197 – Instruction manual ONE-C – EN Once the user is selected and, where applicable, the password has been entered, you will access the PLC's main menu, the "PLC MENU" screen is displayed: ==== PLC MENU ===== INFORMATIONS [*] STOP PLC [ ] USER PARAMETERS [ ] 4.2 "INFORMATION" - Characteristics of the programme: The "INFORMATION" function provides you with fast access to the various advanced pieces of information on the contents of the board.
COAT015197 – Instruction manual ONE-C – EN 4.4 "USER PARAMETERS" - Settings for the program: The "USER PARAMETERS" functions provides access to the list of user settings that can be modified in order to adjust the barrier. Some of these settings can be accessed only via the "ADMIN" user.
COAT015197 – Instruction manual ONE-C – EN T_detection_FAP T_PVT Presign_OUV Presign_FERM Clignotement_feux T_ON_feux T_OFF_feux PWM_verrou T_verrouillage Activation_deverr T_deverrouillage Angle_deverr Mode_1_BP Mode_homme_mort Mode_orange 14 Minimum detection time on the magnetic loop so that closing after passage is activated (default mode: 0.
COAT015197 – Instruction manual ONE-C – EN Cligno_orange Cligno_rouge Veille_Vert T_Veille_Vert English Regondage_auto Reouverture_secu Etat_apprentissage Butee_1 Tolerance_1 Butee_2 Tolerance_2 Offset_Ouv Offset_Ferm signalling elements (LED cover, illuminated rail) during the moving phase. (TRUE: On; FALSE: Off). Activation of the flashing of the signalling elements (LED cover, illuminated rail) during the orange lighting phase. (TRUE: On; FALSE: Off).
COAT015197 – Instruction manual ONE-C – EN Valeur_Filtre_Chocs Duree_Filtre_Chocs Numero_Serie T_pos_ouverte T_detection_choc Rampe_detection_choc Réouverture_obstacle Nb_chocs_autorises Detection threshold of a frontal impact in the closed position for counting the number of impacts suffered (default: 200) Duration of the pulse created by an edge for taking the count into account (default: 2s) Barrier serial number (not configured).
COAT015197 – Instruction manual ONE-C – EN Modification of a setting: To modify a setting in the PLC, you must: === USER PARAM === T_manoeuvre [*] FAT [ ] FAP [ ] =T_manoeuvre= 30 Up(Next)/Down(Prev) Enter => Edit value 4.5 1- Using the directional arrows and the "Enter » key, select the setting that you want to modify. The value is displayed. 2345- Press "Enter" again to be able to modify the value Set the desired value using the up and down arrows.
COAT015197 – Instruction manual ONE-C – EN 4.6 "DOWNLOAD PLC PROG" - Modification of the program using an SD card: To modify the program of the barrier using an SD card, you must: SD Card 1- Remove the SD card already present and insert the SD card which contains the program into the housing provided at the top left of the board 2- Go to the menu of the control board by pressing the "ESC" and "ENTER" keys simultaneously for 3s. 3- Select the "OP" profile by clicking on "ENTER".
COAT015197 – Instruction manual ONE-C – EN 4.7 "UPLOAD PLC PROG" - Recording of the program on an SD card: To modify the program of the barrier on an SD card, you must SD Card 1- Remove the SD card already present and insert the SD card into the housing provided at the top left of the board 2- Go to the menu of the control board by pressing the "ESC" and "ENTER" keys simultaneously for 3s.
COAT015197 – Instruction manual ONE-C – EN 4.8 "LOCATED VARS" - Local variables of the program: The "LOCATED VARS" tab provides access to the statuses of the local variables of the barrier for the purposes of troubleshooting, for example. This function can be accessed only with the ADMIN profile (See §4.1.
COAT015197 – Instruction manual ONE-C – EN 5 TCP/IP Modbus Communication: The ONE-C control board can be controlled via the Ethernet port or the RS485 port using the Modbus communications protocol. 5.1 RS485 Communication: The control board is configured as a slave. If the control board is not located at the end of the line, remove the jumper located to the right of the connector. 5.2 Ethernet TCP/IP Communication The control board is configured as a server. 5.
COAT015197 – Instruction manual ONE-C – EN 5.
COAT015197 – Instruction manual ONE-C – EN Following: Data Life word Data type Word Direction Read Serial number Double word Word Read Default code Read Type Holding Register Holding Register Holding Register Address 4 6-7 8 Description Life word (increment by 1 every second; reset to 10000) Barrier serial number.
COAT015197 – Instruction manual ONE-C – EN 6 Web server The ONE-C control board has a built-in web server that makes it possible to view, control, and configure the barrier using a web browser. 6.1 Connection to the barrier To connect to the barrier, simply connect the barrier to the network using an Ethernet cable via the RJ45 port located to the lower right of the control board.
COAT015197 – Instruction manual ONE-C – EN 6.2 Authentification When you open the web server in your browser, you will see the home page below.
COAT015197 – Instruction manual ONE-C – EN 6.3 Home page The web server's home page provides a precise view of the status of the barrier as well as the possibility to control the barrier for the "ADMIN" profile. Below is an example of the home page for an "ADMIN" profile. In this example, the barrier is closed and is in fault. We also have the "Ouverture – Open" and "Fermeture –Close" buttons that were not present before authentication.
COAT015197 – Instruction manual ONE-C – EN None Red light: The barrier is not open or is about to close. Passage is prohibited. The "Red light" output is activated. None Green light: The barrier is open and is not about to close. Passage is authorised. The "Green light" output is activated. Safety detection The barrier is open and detects a presence on the safety loop and/or in front of the infrared (or ultrasound) cells. Closing is impossible.
COAT015197 – Instruction manual ONE-C – EN 6.4 6.4.1 Other tabs "Configuration" tab The "Configuration" tab makes it possible to configure the barrier's network settings. This allows you to choose whether you want the barrier to have a fixed (Static) IP address or if you want the IP address to be assigned automatically by the network that the barrier is connected to (DHCP). Note: The IP address can be modified only with the "ADMIN" profile. 6.4.
COAT015197 – Instruction manual ONE-C – EN 6.4.3 "Located var" tab (authentication required) The "Located var" tab provides access to the statuses of the local variables of the barrier for the purposes of troubleshooting, for example. Note: The page has to be refreshed in order to view the new status of the variables. 6.4.4 Informations" tab The "Informations" tab includes the list of advanced information for the barrier's program and control board (see §13.2.
COAT015197 – Instruction manual ONE-C – EN 7 7.1 FCC statements Changes or modifications Caution: the user that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 7.2 Class A NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.