AW-CU277B EVB User Guide IEEE 802.11 b/g/n + Bluetooth 4.0 HS Smart Energy Module (PCB 1288 Ver:I2,I3) V0.2 2016/06/06 Kai.
Relative Software Application Software •FTDI VCP Drivers (FT2232D) •Libusb-win32-bin-1.2.6.0 •Cygwin Set-up Procedure 1. Download FTDI VCP Drivers (FT2232D) 2. Download Libusb-win32-bin-1.2.6.0 3. Set Up CU277B EVB for Windows 4. Install FTDI VCP Drivers 5. Install Libusb-win32-bin-1.2.6.0 6. Install Cygwin 7. Insert file “OpenOCD.zip” (By wmsdk_bundle-2.13.78) 8. Burning MCU Image with normal firmware 9. Run WIFI Normal Driver 10. Burning MCU Image with MFG firmware 11. Run WIFI/BT MFG tool 12.
Relative Hardware I2 EVB Power Supply Option: 1. 2. CU277B Reset CU277B Wake Up USB B-type 5V Input Power Jack 5V Input (If the USB B-type driving force shortage) JP11 for CU277B boots Option External QSPI flash to CU277B LDO 5V to 3.3V External 32.
Relative Hardware I3 EVB Power Supply Option: 1. 2. External QSPI flash to CU277B USB B-type 5V Input Power Jack 5V Input (If the USB B-type driving force shortage) AW-CU277BB External 32.768KHz to CU277B FTDI USB to UART/JTAG with CU277B (COM Port 1 for CU277B’s JTAG, COM Port 2 for CU277B’s UART0) LDO 5V to 3.3V LDO 5V to 3.
1. Download FTDI VCP Drivers (FT2232D) Install the driver manually. You can get the driver from FTDI’s web site. http://www.ftdichip.com/Drivers/VCP.
2. Download Libusb-win32 You can get the driver from libusb-win32’s web site. http://sourceforge.
3-1. Set Up CU277B EVB I2 for Windows The USB port (B type) connects the CU277B evaluation board to the PC. Please refer to “AW-CU277B EVB PCB Info” document.
3-2. Set Up CU277B EVB I3 for Windows The USB port (B type) connects the CU277B evaluation board to the PC. Please refer to “AW-CU277B EVB PCB Info” document.
4-1.
4-2. Install FTDI VCP Drivers Verifying Driver Installation: To verify that driver installation has completed successfully, you can open the “Device Manager” (right-click My Computer, select Properties). In the System Properties windows, select Hardware, Device Manager. Two “USB Serial Port” should be listed under MY-PC\Ports (COM & LPT) 10 Confidential
5-1.
5-2. Install Libusb-win32 Verifying Driver Installation: To verify that driver installation has completed successfully, you can open the “Device Manager” (right-click My Computer, select Properties). In the System Properties windows, select Hardware, Device Manager. One “USB Serial Converter A” should be listed under MY-PC\Ports (lib usbwin32 devices) DONE 12 Confidential
6-1. Install Cygwin Install Cygwin: 1. Install Cygwin from: http://www.cygwin.com/setup_x86.exe (for x86 32-bit systems) or http://www.cygwin.com/setup_x86_64.exe (for x86 64-bit systems) 2. Select the option Install from Internet 3. Use default installation path: c:\cygwin. If you chose an alternate installation directory, please make sure that there are no spaces in the path. 4. Pick the Local Package Directory (this is the download cache directory) 5. Select the option Direct Connection 6.
6-2.
7-1. Insert file “OpenOCD.zip” Unzip “CU277B_OpenOCD.zip” and put “readelf.exe” to C:\cygwin\bin 15 Confidential
7-2. Insert file “OpenOCD.zip” Unzip “CU277B_OpenOCD.zip” and put them to C:\cygwin\ 16 Confidential
7-3. Insert file “OpenOCD.zip” Process C:\cygwin\Cygwin.
7-4. Insert file “OpenOCD.
8-1. Burning Normal F/W Check config_normal.txt, layout.
8-2. Burning Normal F/W Key in command : ./flashprog.sh -l layout.txt -b config_normal.
8-3.
9-1.
9-2.
9-3.
10-1. Burning MFG F/W Check config8777_mfg.txt, layout.
10-2. Burning MFG F/W Command : ./flashprog.sh –l layout.txt –b config_mfg.
10-3.
11-1.
11-2.
11-3.
12-1. Radiation Statement Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
12-2. Radiation Statement As long as 3 conditions above are met, further transmitter test will not be required.
12-3. Radiation Statement This device is intended only for OEM integrators under the following conditions: 1) The antenna must be installed such that 20 cm is maintained between the antenna and users, and 2) The transmitter module may not be co-located with any other transmitter or antenna. As long as 2 conditions above are met, further transmitter test will not be required.
12-4. Radiation Statement Plaque signalétique du produit final Ce module émetteur est autorisé uniquement pour une utilisation dans un dispositif où l'antenne peut être installée de telle sorte qu'une distance de 20cm peut être maintenue entre l'antenne et les utilisateurs. Le produit final doit être étiqueté dans un endroit visible avec l'inscription suivante: "Contient des IC: 6100A-CU277B".
12-5. Radiation Statement Taiwan 警語: 第十二條→經型式認證合格之低功率射頻電機,非經許可,公司,商號或使用者均不得擅自變更頻率、加大功率或變更原設計之特性及功能。 第十四條→低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。 前項合法通信,指依電信法規定作業之無線電通信。 低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。 1. 本模組於取得認證後將依規定於模組本體標示審驗合格標籤 2.