AW-CM217NF IEEE 802.11 a/b/g/n/ac Wireless LAN and Bluetooth M.2 Combo Module User Guide Document release Date Version 0.
-2-
Contents 1. WLAN Basic Test Driver Installation Throughput Test RF Tx/Rx Performance Test 2.
1. WLAN Basic Test Driver Installation COMPONENTS bcmwI5/ bcmwI564.sys and bcmwI5.inf bcmwI5/ bcmwI564.sys and bcmwI5.inf are the dongle host driver for PCI Bridge Card. It also includes a dongle image for download to the PCI dongle. wl.exe wl is an utility application that one can use to control the software running in the PCI dongle, e.g. initiate an association and modify WLAN parameters.
• SSID: “ADHOC#1” • Mode: Ad Hoc RSSI: -41 dBm noise: -105 dBm Channel: 1 • BSSID: B2:51:28:6B:3C:A1 Capability: IBSS • Supported Rates: [ 1(b) 2(b) 5.5(b) 11(b) ] CONNECTING TO AN INFRASTRUCTURE NETWORK WITH NO SECURITY (AP CONNECTION) To connect to the network through an AP with SSID = Eval4325 Run wl join Eval4325. CONNECTING TO AN INFRASTRUCTURE NETWORK WITH WEP SECURITY To connect to the network that uses 12345 as the network key • Run wl join Eval4325 key 12345.
To enable legacy IEEE 802.11 Power Save (PS) mode • Run wl PM 1. To enable Fast IEEE 802.11 Power Save mode • Run wl PM 2. Note: • The STA automatically transitions to Legacy PS mode when no data is being sent or received. • The STA automatically disables PS mode when data is being sent or received. MEASURING WLAN THROUGHPUT The throughput measurement shows the performance of the TCP/IP layer over the wireless link.
LAN HOST COMPUTER. AW-CM217NF A Reference Computer P Chariot EndPoint Console FIG. 2.2 HOST Reference COMPUTER. Computer AW-CM217NF Chariot EndPoint Console FIG. 2.3 MEASURING THROUGHPUT USING NETIQ CHARIOT Test Procedure 1. Bring up the AW-CM217NF demo boar with the IP address set as 192.168.1.110. 2. Connect the reference computer with Chariot Console, which is assigned an IP address of 192.168.1.100, to the LAN port of the AP 3.
1. From the Start menu, select Run. 2. Type cmd, then click OK. 3. Navigate to the directory that contains wl.exe 4. Enter the wl ver command to check the current WL driver version. 5.
wl mpc 0 wl phy_watchdog 0 wl country ALL wl band b wl channel 1 wl up wl phy_forcecal 1 wl scansuppress 1 wl txchain 1 wl txcore -k 1 -o 1 wl 2g_rate -r 54 -b 20 wl phy_txpwrctrl 1 wl txpwr1 -1 wl txpwr1 -o -d 15 wl pkteng_start 00:11:22:33:44:55 tx 100 1024 0 This will send continuous Tx Packets with 100 us packet interval,1024 byte packet length. Data rate =54Mbps ,Channel=1 and output power =15dBm. 2.
wl txchain1 wl txcore -s 1 -c 1 wl 2g_rate -h 7 -b 20 wl phy_txpwrctrl 1 wl txpwr1 -o -d 14 wl pkteng_start 00:11:22:33:44:55 tx 100 1024 0 This will send continuous Tx Packets with 100 us packet interval,1024 byte packet length. Data rate =MCS7, Bandwidth=20Mhz, Channel=1 and output power =14dBm. 2.
This will send continuous Tx Packets with 100 us packet interval,1024 byte packet length. Data rate = MCS7 ,Bandwidth=40Mhz, Channel=3 and output power =12dBm. 11a rate: wl mpc 0 wl phy_watchdog 0 wl country ALL wl band a wl channel 36 wl up wl phy_forcecal 1 wl scansuppress 1 wl txchain 1 wl txcore -o 1 wl 5g_rate -r 54 -b 20 wl phy_txpwrctrl 1 wl txpwr1 -o -d 14 wl pkteng_start 00:11:22:33:44:55 tx 100 1024 0 This will send continuous Tx Packets with 100 us packet interval,1024 byte packet length.
wl 5g_rate -h 7 -b 20 wl phy_txpwrctrl 1 wl txpwr1 -o -d 12 wl pkteng_start 00:11:22:33:44:55 tx 100 1024 0 This will send continuous Tx Packets with 100 us packet interval,1024 byte packet length. Data rate = MCS7 ,Bandwidth=20Mhz, Channel=36 and output power =12dBm.
4. Run the following command set 11b/g rate: wl mpc 0 wl phy_watchdog 0 wl country ALL wl band b wl channel 7 wl up wl phy_forcecal 1 wl scansuppress 1 wl rxchain 1 wl reset_cnts wl counters This will enter Channel 7 receive mode. 2.4G 11n 20 SISO rate: wl mpc 0 wl phy_watchdog 0 wl country ALL wl band b wl chanspec 1/20 wl up wl phy_forcecal 1 wl scansuppress 1 wl rxchain 1 wl reset_cnts wl counters This will enter Channel 1, bandwidth=20Mhz receive mode.
2.4G 11n 40 SISO rate: wl pkteng_stop rx wl down wl mpc 0 wl country ALL wl up wl phy_watchdog 0 wl scansuppress 1 wl band b wl down wl mimo_bw_cap 1 wl mimo_txbw 4 wl up wl chanspec -c 6 -b 2 -w 40 -s 0 wl 2g_rate wl txchain 1 wl rxchain 1 wl phy_forcecal 1 wl pkteng_start 00:11:22:33:44:55 rxwithack wl counters wl reset_cnts This will enter Channel 6, bandwidth=40Mhz receive mode.
wl reset_cnts wl counters This will enter Channel 36 receive mode. 5G 11n 20 SISO rate: wl mpc 0 wl phy_watchdog 0 wl country ALL wl band a wl chanspec 36/20 wl up wl phy_forcecal 1 wl scansuppress 1 wl rxchain 1 wl reset_cnts wl counters This will enter Channel 36, bandwidth=20Mhz receive mode.
This will enter MCS7 HT40, Channel 38 receive mode. ※.The default MAC address is 001122334455. Packets sent from Signal Generator must have the same MAC address as the DUT’s MAC address (Runtime mac address can be overrode by using wl cur_etheraddr xx:xx:xx:xx:xx:xx . ※. Use “wl counters” and find the received frame numbers in “rxdfrmocast”. ※. The RX PER = [ (Total lost packets at the receiver) / (Total sent packets from the Signal Generator) ] x 100%.
2. Bluetooth Basic Test Download Mini-driver 1. Start Broadcom BlueTool. 2. On the View menu, click Log Windows Details. 3. On the Transport menu, click HCI Control. 4. In Select HCI Control Window Transport: a. Select USB as the type of transport. b. In the usb port list, select usb0.
c. Click OK. 5. In HCI Control, select the HCI protocol active check box 6.
Download Minidriver. 7. On the Transport menu, click Download Firmware/Config. 8. In Select Download Firmware/Config Transport: a. Select USB as the type of transport. b. In the usb port list, select usb0. c. Click OK. 9. In Download, configure the settings to match those shown below 10. Click Execute. 11. Select the HCI protocol active check box Throughput Test Bluetool contains a throughput test feature that can be used with two or more AW-CM217NF devices.
2. If the Log Window is not already open, select “View” and then select “Log Window”.Select “Transport” and then Select “HCI Control.” New window pop-up, select “USB” and enter usb port number. Click “OK”. 3. Download mini driver (see 3.1) 4. In the “HCI Control” window, select “7.3 Host Controller & Baseband Commands” (Note: may be 4.3, depending on version) 5. Double Click the “Write Scan Enable” entry 6. Select “Inquiry and Page Scan Enabled” and click “OK” 7. Double Click “Set Event Filter” 8.
NOTE: once the connection has been established, Inquiry and Page Scan can be disabled. Also, go to: “7.3 Host Controller & Baseband Commands” →→ “Set Event Filter”. Select “Connection Setup”; Select “Allow Connections from all devices”; Select “Do NOT Auto accept the connection” and hit ‘OK’. This will make the slave device non-discoverable and increase throughput by reducing overhead. SET UP AND EXECUTE THE THROUGHPUT TEST SET UP THE SLAVE AS THE RECEIVER 1.
RESETTING THE USB DEVICE To reset the USB device •In HCI Control, in the HCI Control commands list, select 7.3: Host Controller & Baseband Commands (3 key), and then double-click Reset. READING THE BLUETOOTH DEVICE ADDRESS To read the Bluetooth Device Address • In HCI Control, in the HCI Control commands list, select 7.4: Informational Parameters (4 key), and then double-click Read_BD_ADDR. The Bluetooth Device Address (BD_ADDR) is displayed in the log window.
Enable_Device_Under_Test_Mode. The AW-CM217NF is now ready to receive a connection request from the Bluetooth tester and begin testing specified RF parameters.
Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
install or remove this RF module in the user’s manual of the end product which integrates this module. The end user manual shall include all required regulatory information/warning as show in this manual. Industry Canada statement: This device complies with RSS-210 of the Industry Canada Rules.
produit final. Dans ces circonstances, l'intégrateur OEM sera chargé de réévaluer le produit final (y compris l'émetteur) et l'obtention d'une autorisation distincte au Canada. End Product Labeling This transmitter module is authorized only for use in device where the antenna may be installed such that 20 cm may be maintained between the antenna and users. The final end product must be labeled in a visible area with the following: “Contains IC: 6100A-CM2XXNF”.
1. 本模組於取得認證後將依規定於模組本體標示審驗合格標籤。 2.