AW-BT715C Bluetooth Module Demo Board User Guide Version 0.
Document release Date Version 0.1 2014/06/26 Modification Initial Version -2- Initials Approved N.C.
Contents 1. Install driver and tool install active perl version: 5.8.4.810 before install Broadcom tool install Broadcom tool BLUETOOL version:1.7.3.3 install CP210X(USB to UART ) driver CP210X_VCP_Win2K_XP_S2K3 2.
Check the com port that will be used. A.
1. From the BlueTool View menu, select Log Window. A record of issued commands will be maintained in the log window. 2. From the Transport menu, select HCI Control. a. In the Select HCI Control Window Transport window (screenshot below), select UART, the COM port that will be used, 115200, and CTS flow control. b. Click OK.
-6-
B. Reset 1.In the HCI Control window a. Select 7.3 Host Controller & Baseband Commands (3 key) for HCI protocol active b.Double-click Reset. 2. Confirm that this step is done successfully by viewing the log window C. Download the Configuration File 1. In the HCI Control window a. Select 0: Vendor-specific Commands (0 key) for HCI protocol active b.Double-click Download Minidriver. 2.
3. From the BlueTool Transport menu, select Download Firmware/Config…. 4. In the Select Download Firmware/Config Transport window a. select UART, the COM port that will be used, 115200,and CTS flow control. b. Click OK.
5. In the Download: com @115200 window, a. select 20702 A0/A1/B0 Runtime RAM for Device configuration b. mark From burn image c. key in 0x00090000 on SS location d. click Locate e. select the configuration f. click open g. click Execute h. close the window D. Verify the DUT condition by reading the BD address 1. In the HCI Control window a. mark HCI protocol active ,select 7.4 Informational Parameters(4 keys)from it b. Double-click Read BD ADDR. 2. The Log Window will show the BD address.
E. Set Event Filter 1. In the HCI Control window a. select 7.3 Host Controller & Baseband Commands (3 key) for HCI protocol active b. Double-click Set Event Filter. 2.In the HCI Command window a. select connection setup for filter type b. select Allow Connecttion from all devices for Connection_Setup_ Filter _Condition_type c. select Do Auto accept the connection with role switch disabled for Auto_Accept_Flag d. Click OK. 3. Confirm that this step is done successfully by viewing the log window .
F. Write Scan Enable 1. In the HCI Control window a. select 7.3 Host Controller & Baseband Commands (3 key) for HCI protocol active b. Double-click. Write Scan Enable 2. In the HCI Command window a. select Inquiry and Page Scan enabled for scan_Enable b. Click OK. 3. Confirm that this step is done successfully by viewing the log window .
G. Enable Device Under Test Mode 1. In the HCI Control window a. select 7.6 Testing Commands (6 key) for HCI protocol active b. Double-click Enable Device Under Test Mode 2. Confirm that this step is done successfully by viewing the log window .
H.TX Testing 1. In the HCI Control window a. select 0: Vendor-specific Commands (0 key) for HCI protocol active b. Double-click TX Test 2. In the HCI command window a. From the Local_Device_BD_ADDR shortcut menu, select the Bluetooth device address of the DUT. b. From the Hopping_Mode shortcut menu, select single frequency. c. From the frequency shortcut menu, select which frequency you want to test. d. From the Modulation_Type shortcut menu, select PRBS9 Pattern. e.
- 14 -
I. RX Testing 1. In the HCI Control window a. select 0: Vendor-specific Commands (0 key) for HCI protocol active b. Double-click RX Test 2. In the HCI command window a. From the Local_Device_BD_ADDR shortcut menu, select the Bluetooth device address of the DUT. b. From the report period shortcut menu, select which period you want to used c. From the frequency shortcut menu, select which frequency you want to test. d. From the Modulation_Type shortcut menu, select PRBS9 Pattern. e.
- 16 -
Measure performance with instrument for auto testing (ex. Agilent N4010) Step : A to G Measure performance with instrument for manual testing (ex. Spectrum Analyzer) Step :A to D ,H(testing TX) or I(testing RX) The device under test (DUT) should be reset before each procedure. Re-test or replace the DUT need to switch Bluetool and plug DUT. If the Log Window didn’t show successful message in any step (Step B~I),please reset it.
2.
EVB PCB Stackup - 21 -
Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
This device is intended only for OEM integrators under the following conditions: 1) The antenna must be installed such that 20 cm is maintained between the antenna and users, and 2) The transmitter module may not be co-located with any other transmitter or antenna. As long as 2 conditions above are met, further transmitter test will not be required.
Industry Canada statement: This device complies with RSS-210 of the Industry Canada Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Ce dispositif est conforme à la norme CNR-210 d'Industrie Canada applicable aux appareils radio exempts de licence.
This device is intended only for OEM integrators under the following conditions: (For module device use) 1) The antenna must be installed such that 20 cm is maintained between the antenna and users, and 2) The transmitter module may not be co-located with any other transmitter or antenna. As long as 2 conditions above are met, further transmitter test will not be required.
End Product Labeling This transmitter module is authorized only for use in device where the antenna may be installed such that 20 cm may be maintained between the antenna and users. The final end product must be labeled in a visible area with the following: “Contains IC: 6100A-BT715C”.
低功率電波輻射性電機管理辦法 第十二條 經型式認證合格之低功率射頻電機,非經許可,公司、商 號或使用者均不得擅自變更頻率、加大功率或變更原設計之 特性及功能。 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通 信;經發現有干擾現象時,應立即停用,並改善至無干擾時 方得繼續使用。 前項合法通信,指依電信法規定作業之無線電通信。 低功率射頻電機須忍受合法通信或工業、科學及醫療用電波 輻射性電機設備之干擾。 模組認證: 1. 本模組於取得認證後將依規定於模組本體標示審驗合格標籤。 2.