MST200 High Performance Multi-Service Terminal Device Quick Installation Guide V1.
Azalea MST200 Quick Installation Guide Copyright 2008 Azalea Networks All rights reserved. Printed in China. 2008. Azalea Networks reserves the right to change, modify, revise this publication without notices. Trademarks Copyright 2008 by Azalea Networks, Inc. All rights reserved. Azalea, the Azalea logo, and MST200 are trademarks of Azalea Networks, Inc. All other brand and product names are registered trademarks or trademarks of their respective holders.
Azalea MST200 Quick Installation Guide incidental, consequential or indirect damages including but not limited to loss of use, loss of data, business interruption, loss of revenue, loss of business or other financial loss arising out of or in connection with any of the products or other goods or service furnished by the company under this manual, even if advised of the possibility of such damages.
Azalea MST200 Quick Installation Guide FCC Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. REMINDING This device complies with Part 15 of the FCC Rules.
Azalea MST200 Quick Installation Guide Safety Warnings MST200 must be installed by trained professional installation technician. All below warning information must be read before installation. General Safety Warnings You can be killed or injured if performing antenna installation near electrical power lines. Carefully read and follow all instructions in this guide. Please be sure there are no high voltage and electronic field.
Azalea MST200 Quick Installation Guide where the antenna can come into contact with such circuits. When installing antennas, take extreme care not to come into contact with such electrical circuits, as they can cause serious injury or death. Grounding Warning Please always remember to protect your MST200 system by installation of grounding lines. The ground connection must be complete before connecting power to the MST200 enclosure.
Azalea MST200 Quick Installation Guide Contents 1 ABOUT THIS MANUAL ......................................................................................................................... 8 1.1 FURTHER READING ............................................................................................................................. 8 1.2 BEFORE YOU BEGIN ........................................................................................................................... 8 1.3 PACKAGE CONTENTS ...
Azalea MST200 Quick Installation Guide 1 About This Manual This Quick Installation Guide provides step by step instructions for installing and setting up the MST200. Content includes methods to access the MST200. For configuration, please refer to manuals in the attached CD ROM. 1.1 Further Reading More detailed configuration instructions can be found in the CD-ROM. 1.2 Before You Begin Open the shipping box and carefully unpack its contents. The packing list is as shown below.
Azalea MST200 Quick Installation Guide 2 Overview 2.1 Function Introduction The Azalea Multi-Service Terminal 200 (MST200) is the high performance multi-service terminal device specifically designed for wireless video surveillance. It is the first dedicated device for wireless video surveillance in the industry. This device delivers unprecedented stability and reliability for long distance wireless transmission of high resolution video streams.
Azalea MST200 Quick Installation Guide 2.3 Operating Range Operating Temperature Range Storage Temperature Range Non-Condensing Humidity Range Power input (VAC) AC Power Consumption -40℃-55℃ -40℃-80℃ 10%-90% 100-240 (50/60 Hz) 9W (typical) 2.4 Environmental Rating Shock and Vibration Rating ETSI 300-19-2-4 spec T41.E class 4M3 2.5 Ethernet Cable Figure below shows one end of the Ethernet cable for connecting to the Ethernet port on the MST200, and the other end of the cable with a standard RJ45 jack.
Azalea MST200 Quick Installation Guide Connection guide for power cable: Phase(Live Line) – 2nd pin of 3 pin power cable with water protection Neutral(Zero Line) – 3rd pin of 3 pin power cable with water protection Grounding– 1st pin of 3 pin power cable with water protection z Power Plug The other side of power cable is a standard connection according to local regulation 2.
Azalea MST200 Quick Installation Guide 3 Installation Preparation 3.1 Site Survey site surveyis is the key step in wireless network project, which is decisive to the reasonablity of system design and the smooth implementation of deployment. Figure 5 Site Survey 3.
Azalea MST200 Quick Installation Guide 3) Interference must be considered in site selection. New site should avoid known interference, unless the interference is controlable. 3.4 Site Survey Guide Site survey mainly include location selection and detailed site study 3.4.1 Site Selection The site survey engineer should be experienced with good knowledge of microwave propagation, antenna ,feeder, MSR products and experiences in wireless network deployment.
Azalea MST200 Quick Installation Guide D Installation Tool D Measurement Tool D Power Panel D Template of Installation 3.
Azalea MST200 Quick Installation Guide 4 Antenna Installation MST200 uses two types of antennas: built-in antenna and external antenna. The built-in antenna has already been installed inside the plastic enclosure at the front of MST200. The built-in antenna works at the same frequency band as the corresponding MST200 and is configured to the factory setting (See figure below).
Azalea MST200 Quick Installation Guide According to the LEDs that indicate the wireless signal strength, users can adjust the horizontal degree of MST200. Since the distance between MSR routers and MST200 is usually quite long, the extent of each adjustment should keep small, not exceeding 5 degrees. After adjustment, users should wait a few seconds, and observe the change on LED to get the maximum signal strength.
Azalea MST200 Quick Installation Guide 5 MST200 Installation Installation procedure for MST200 on mast 1. Use suitable bolts to fasten the chassis onto the back of MST200 (See figures below). Figure 8 Chassis, Suitable bolts and the Back Side of MST200 Figure 9 Chassis Installation Effect 2. Use suitable bolts to fasten the bracket onto the chassis (See figures below).
Azalea MST200 Quick Installation Guide Figure 11 Bracket Installation Effect Note: To adjust MST200 angle, one can adjust the angle of the bracket by using the fasten bolt as axis. 3. Use suitable bolts to fasten the bracket onto the mast (See figure below).
Azalea MST200 Quick Installation Guide 6 Grounding of MST200 The grounding of MST200 is to protect MST200 from electrostatic damage, there is grounding terminal on the enclosure of MST200. Tools needed: Paper knife, Pliers, Crimping Pliers, and Cross Screwdriver. The procedure of grounding is as: 1. Put naked side of grounding wire into the copper ring, and press it firmly by Crimping Pliers; 2. Unmount the screw of in the grounding terminal. 3. Put the copper ring into the grounding terminal.
Azalea MST200 Quick Installation Guide 7 Ethernet Cable Installation Ethernet cable connects MST200 mesh network to wire network. Ethernet cable is needed, only when MST200 used as gateway. The performance of network cable will degrade seriously with length longer than 100 meters. So in MSR nodes planning, it is better to choose access point to wire network within 100 meters. The process of Ethernet cable installation 1. Unscrew the protective cap on the Ethernet enclosure.
Azalea MST200 Quick Installation Guide 8 Power Cord Installation MST200 use 100-240V AC as power, the power interface is on the left bottom of MST200. Power cable should be the last step of installation.
Azalea MST200 Quick Installation Guide 9 Completed Installation Figure 16 Complete Installation Copyright 2008 Azalea Networks 22
Azalea MST200 Quick Installation Guide Appendix 1. MST200 basic specifications y Power range: 100 ~ 240 VAC 50/60Hz y Power consumption: 9W (in typical circumstances) y Operating temperature: -40℃ - 55℃ y Storage temperature: -40℃ - 80℃ y Operating humidity (non condensing): 10%-90% 2.