AXIS D2110-VE Security Radar Installation Guide
Read this first Read through this Installation Guide carefully before installing the product. Keep the Installation Guide for future reference. Legal considerations Radar surveillance can be regulated by laws that vary from country to country. Check the laws in your local region before using this product for surveillance purposes. Liability Every care has been taken in the preparation of this document. Please inform your local Axis office of any inaccuracies or omissions.
Korea 이 기기는 업무용 환경에서 사용할 목적으로 적합 성평가를 받은 기기로서 가정용 환경에서 사용하 는 경우 전파간섭의 우려가 있습니다. 적절히 접지 된 STP (shielded twisted pair) 케이블을 사용하여 제품을 연결 하십시오. Radio transmission This equipment may generate or use radio frequency energy. The user could lose the authority to operate this equipment if an unauthorized change or modification is made. The transmitter operates at 24.05–24.25 GHz with maximum output power < 20 dBm. USA This product complies with FCC radiation exposure limits for an uncontrolled environment.
This product complies with IEC/EN/UL 62368-1, safety of audio/video and IT equipment, and IEC/EN/UL 60950-22, Safety of Information Technology Equipment. The product shall be grounded either through a shielded network cable (STP) or other appropriate method. Disposal and recycling When this product has reached the end of its useful life, dispose of it according to local laws and regulations.
AXIS D2110-VE Security Radar Package contents • • • • • • • • • • • • • AXIS D2110-VE Security Radar Mount bracket Pipe adapter (2x) Screw T30 (4x) for use with pole mount.
AXIS D2110-VE Security Radar Product overview 1 2 3 4 5 6 7 8 9 10 11 12 13 Control button Network LED Status LED Power LED PoE out LED microSD card slot DC power connector I/O connector Relay connector Grounding screw Network connector (PoE in) Network connector (PoE out) Intrusion alarm sensor 6
AXIS D2110-VE Security Radar Where to install the product The detector is intended for monitoring open areas. Any solid object (such as a tree or a bush) in the coverage area will create a blind spot (radar shadow) behind it. Install the detector on a pole, or on a spot on a wall where there are no other objects or installations close to it. To be able to correctly identify movement in the coverage area, the detector needs to be installed on a stable mount. Do not install the detector on a swaying pole.
AXIS D2110-VE Security Radar The following table shows the detection range at different mounting heights when detecting a 1.8 m (6 ft) tall person walking. Mounting height 3.5 m (11 ft) 4 m (13 ft) 4.5 m (15 ft) 5 m (16 ft) Near detection limit 4.5 m (15 ft) 6 m (20 ft) 7 m (23 ft) 8.5 m (28 ft) Far detection limit (max.
AXIS D2110-VE Security Radar How to install the product 1. Use the drill template and drill holes in the wall. 2. Fasten the mounting bracket to the wall. 3. Route the network cable through the mounting bracket. Leave approximately 30 cm (12 in) of cable for connecting the detector. CAUTION Risk of water leaks. Do not use network cables with capped network connectors because they can cause tearing of the cable gasket. 4.
AXIS D2110-VE Security Radar 1 2 3 Hook, bracket side Hook, detector side Screw (2x) 8. Attach the detector to the mounting bracket with the hooks and tighten the screws with 1 N m (0.7 lb ft) torque.
AXIS D2110-VE Security Radar 3 4 5 Power I/O Ground/Relay 9. Remove the left cable gasket and pull the tab to open a hole for the network cable. CAUTION Risk of water leaks. • Only open holes in cable gaskets that are used. • If a cable gasket is torn, replace it with a new cable gasket. 10. Push the network cable through the cable gasket. 11. Pull the network cable back slightly so that the cable gasket adjusts itself on the cable. CAUTION Risk of water leaks.
AXIS D2110-VE Security Radar 1 2 3 4 5 6 Nut Gasket Body Seal Cap Plug (discard) 15. If using a grounding wire, attach it to the cable shoe using cable shoe pliers. Attach the cable shoe to the grounding screw. Make sure the cable shoe is in contact with the grounding surface. 16. Connect external devices to the detector. 17. Connect the network cable. 18. Make sure that the LEDs indicate the correct condition. See LED Indicators on page 16. 19. Pull out the strut and close the cover. 20.
AXIS D2110-VE Security Radar For more information about how to find and assign IP addresses, see the document How to assign an IP address and access your device on the device page at axis.com. Browser support You can use the device with the following browsers: ChromeTM Firefox® Edge® Windows® recommended x x OS X® recommended Other operating systems x Safari® x x To find out more about how to use the device, see the User Manual available at axis.com.
AXIS D2110-VE Security Radar Reset to factory default settings Important Reset to factory default should be used with caution. A reset to factory default resets all settings, including the IP address, to the factory default values. To reset the product to the factory default settings: 1. Disconnect power from the product. 2. Press and hold the control button while reconnecting power. See Product overview on page 6 . 3.
AXIS D2110-VE Security Radar Further information • • • • For the latest version of this document, see axis.com The user manual is available at axis.com To check if there is updated firmware available for your device, see axis.com/support For useful online trainings and webinars, see axis.com/academy Optional accessories For a complete list of available accessories for this product, go to the product’s page on axis.com and select Software & Accessories.
AXIS D2110-VE Security Radar Specifications To find the latest version of the product’s datasheet, go to the product page at axis.com and locate Support & Documentation. LED Indicators Status LED Indication Green Steady green for normal operation. Amber Steady during startup. Flashes when restoring settings. Network LED Indication Green Steady for connection to a 100 Mbit/s network. Flashes for network activity. Amber Steady for connection to a 10 Mbit/s network. Flashes for network activity.
AXIS D2110-VE Security Radar The control button is used for: • Resetting the product to factory default settings. See page 14. Connectors Network connector RJ45 Ethernet connector with Power over Ethernet Plus (PoE+). Network connector (PoE out) Use this connector to supply power to a camera. Power over Ethernet IEEE802.3at Type 2, max 30W I/O connector Use the I/O connector with external devices in combination with, for example, motion detection, event triggering, and alarm notifications.
AXIS D2110-VE Security Radar 3– 6 Configurable (Input or Output) Digital input – Connect to pin 1 to activate, or leave floating (unconnected) to deactivate. 0 to max 30 V DC Digital output – Internally connected to pin 1 (DC ground) when active, and floating (unconnected) when inactive. If used with an inductive load, e.g., a relay, connect a diode in parallel with the load, to protect against voltage transients.
AXIS D2110-VE Security Radar Relay connector CAUTION Use single core wires for the relay connector. Function Specifications Type Normally open Rating 30 V DC/5 A 125 V AC/10 A 250 V AC/5 A Isolation from other circuitry 2.
AXIS D2110-VE Security Radar Safety information Hazard levels DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE TICE NO Indicates a situation which, if not avoided, could result in damage to property.
AXIS D2110-VE Security Radar Safety instructions DANGER Risk of electric shock. All cables shall be de-energized before installing or performing maintenance on the product. WARNING The Axis product shall be installed by a trained professional, and in compliance with local laws and regulations. CAUTION Be careful of sharp metal edges. Use cut-resistant gloves during installation. NOTICE TICE NO • The Axis product shall be used in compliance with local laws and regulations.
AXIS D2110-VE Security Radar Battery Lithium coin cell 3.0 V batteries contain 1,2-dimethoxyethane; ethylene glycol dimethyl ether (EGDME), CAS no. 110-71-4. WARNING • Risk of explosion if the battery is incorrectly replaced. • The battery should be replaced with an identical battery only. • Used batteries should be disposed of according to local regulations or the battery manufacturer's instructions.
Installation Guide AXIS D2110-VE Security Radar © Axis Communications AB, 2018 - 2019 Ver. M1.14 Date: October 2019 Part No.