USER M A NUA L AIVO-70A4K
Thank you for purchasing the IP camera tester. Please read the manual before using the IP camera tester and use properly. For using the IP camera tester safely, please first read the「Safety Information」carefully in the manual. The manual should be kept well in case of reference. Keep the S/N label for after-sale service within warranty period. Product without S/N label will be charged for repair service.
Content 1 .Safety information ----------------------------------------------------------------------------------------------------- 1 2. IP Camera Tester Introduction --------------------------------------------------------------------------------------- 2 2.1 General ----------------------------------------------------------------------------------------------------------- 2 2.2 Packing list ------------------------------------------------------------------------------------------------------ 3 2.
3.3.15 TVI camera test ( *Optional )------------------------------------------------------------------ 61 3.3.16 AHD camera test ( *Optional ) ---------------------------------------------------------------- 63 3.3.
3.3.37 Office ------------------------------------------------------------------------------------------------107 3.3.38 LED Flashlight -------------------------------------------------------------------------------------107 3.3.39 Browser ---------------------------------------------------------------------------------------------108 3.3.40 Notepad ---------------------------------------------------------------------------------------------108 3.3.
1 .Safety information ◆ The tester is intended to use in compliance with the local rules of the electrical usage and avoid to apply at the places which are inapplicable for the use of electrics such as hospital, gas station etc. ◆ To prevent the functional decline or failure, the product should not be sprinkled or damped. ◆ The exposed part of the tester should not be touched by the dust and liquid.
◆Never connect the meter with any voltage source while the function switch is in the current, resistance, capacitance, diode, continuity, otherwise it will damage the meter. ◆Never perform capacitance measurements unless the capacitor to be measured has been discharged fully. ◆Never measure any of resistance, capacitance, diode or continuity measurements on live circuits.
2.2 Packing list 1). Tester 2). Adaptor DC12V 2A 3). Network cable tester 4). Polymer lithium ion battery (7.4V DC 5000mAh) 5). BNC cable 6). RS485 cable 7). SC,ST connector(Only for optical power meter) 8). Multi-meter test leads one pair of red and black (only for the Multi-meter models) 9). Output Power cable 10). Audio cable 11). TDR alligator clamp (only for TDR models) 12). Safety cord 13). Tool bag 14). Manual 15).8GB SD card Page.3.
2.3 Function interface Page.4.
Press more than 2 seconds, turn on or off the device,short press to turn on or off 1 the menu display 2 Menu key. press it to call shortcut- menu 3 4xzoom the image displays. 4 Far focus: Focus the image faraway 5 Near focus: Focus the image nearby 6 TELE: zoom in the image 7 WIDE: zoom out the image 8 Open/set, Confirm the setting of parameters, open or enlarge the aperture 9 10 Upward, set function or add parameter.
Top interface Bottom interface 21 TDR cable test interface (Optional) 22 SDI input (BNC interface) ( Optional) 23 RS485 Interface: RS485communication for the PTZ 24 HDMI IN 25 Video signal output(BNC interface)/ cable tracer interface 26 CVBS input /AHD /TVI/CVI Coaxial interface (AHD /TVI/CVI Optional ) 27 Optical power meter interface (Optional) 28 PoE power supply output or LAN test port (Use to test PoE or non-PoE IP camera) 29 PSE power sourcing equipment.
32 Visible red laser source emits Interface (Optional) 33 Power battery switch 34 DC 12V 2A charging interface 35 Audio input 36 Audio output and earphone interface 37 USB 5V 2A power output (used only for power, not data) 38 UTP cable port: UTP cable tester port/ Cable tracer port 39 Micro SD card moveable (comes with 8GB, supports up to 32GB) 40 HDMI output interface 3. Operation 3.1 Installing the Battery The battery main switch at the right-bottom corner of tester bottom.
hours will not damage the battery. Notice: Press the key several seconds to restore the default settings when the instrument works abnormally. Multi-meter: The red and black multi-meter pen must insert the corresponding port. Warnings: Instrument communication port is not permitted access circuit voltage over 6V, otherwise damage the tester. Warnings: Not allow insert multi-meter pen in the current terminal to measure voltage. 3.2 Instrument connection 3.2.
Note:1) If the IP camera requires PoE power, then connect the IP camera to the IP tester’s LAN port . The tester will supply PoE Power for the IP camera. Click on the icon labeled POE to turn the PoE Power off or on. 2) If use the tester’s menu to turn off the tester’s PoE power supply, the PoE switch and the power sourcing equipment are allowed to connect to the tester’s PSE port, and the PoE power will be supplied to the IP camera by the tester’s LAN port.
(1) ) Connect the camera's video output to the IP tester’s VIDEO IN. The image will display on the tester after pushing the PTZ icon. (2) CCTV IP Tester “VIDEO OUT” interface connect to the Video input of monitor and optical video transmitter and receiver, the image display on the tester and monitor. (3) Connect the camera or the speed dome RS485 controller cable to the tester RS485 interface (Note: positive and negative connection of the cable). 3.2.
3.2.4 HDMI IN DVR or other device’s HDMI out port connect to tester’s HDMI in port, the meter will display input image. 3.3 OSD menu Press the key 2 seconds to turn on Press the key again to turn off short press the key to enter sleep mode, press it again to test. If tester works abnormally and cannot be turned off , Press the key turn off, the tester reset. 3.3.1 Lite mode & Normal mode Lite mode: You can easy find corresponding apps Page.11.
In Lite mode, Press the icon several seconds, can move the icon to other apps. In lite mode, click the finger icon in the lower right corner to release lock icon, move icons and change function icons sequence. Normal mode Tap the screen and slide left or right to change menu. Page.12.
In normal mode, press icon several seconds, go screen management status. Change icons sequence and move it to common tools bar. You can move the icon to any pages, self-define the number of icons in any page. Make interface sample and individuality. Page.13.
Create New Folder: Drag the icon to the folder in top right corner, enter the folder name, icon will be auto placed in the new named folder. Press the folder several seconds, to change the folder name, you can move the icon out of folder, the folder will be auto deleted until move out all icons. Select Icons to enter, if quit, please click Click SD card, install or remove SD card. Page.14.
3.3.2 Drop-down Menu Press and slide at right top right corner twice to open shortcut menu. The shortcut menu includes POE power output, IP settings, Wi-Fi, HDMI IN, CVBS, Video OUT, LAN, Brightness, settings etc.
3.3.3 Short cut-menu You can call shortcut menu by press tester’s “menu” key, you can self-define shortcut menu. Press the key“ ”, you can turn on it, and switch functions, then press to enter app, tap other area on the screen, to exit the menu. Short cut-menu setting, you can long press any app in the all applications list, it will auto move to shortcut menu. If delete any app in the shortcut menu, please select a app and press several seconds, it will be deleted. Page.16.
3.3.4 Screen capture Long press the key “enter”, can capture screen interface and save it in any time. You can go file management to view “File management - SDcard - Pictures - Screenshots”. 3.3.5 TesterPlay Mobile screen projection (Only for android version) The meter creates WIFI hotspot, connect mobile phone to the tester’s WIFI hotspot, or the tester and mobile phone connect to the same Wi-fi network.
PC screen projection: Install VLC player in the PC, turn on the VLC player "Media - Open Network Streaming", and input the RTSP address of on the top instrument two-dimensional code, click "play" to view the screen real-time projection. (you also can install “VLC player” in the mobile phone, tester and mobile phone display at the same time) Page.18.
3.3.6 Rapid video Press enter function, One key to detect all network cameras and auto play the images. Auto log in and display camera image. Detailed operation refer to ONVIF function. Page.19.
After exit ONVIF app, Click Refresh to search ip address. 3.3.7 IP discovery Press IP discovery ,tester auto-scan the whole network segment IP, as well as auto-modify the tester’s IP to the same network segment with the scanned camera's IP. Local IP: Tester’s IP address, Tester can auto-modify the tester’s IP to the same network segment with the scanned camera's IP. Discovery IP: Connected tester equipment’s IP address.
current IP address. Temp IIP:After searching IP address, the modified tester’s IP address will not be saved, if you do not select “Temp IP”, the tester’s IP address will auto-save after searching. Start: PING function, Click "Start", can PING camera’s IP.
then default use the modified password to log in. If you select ONVIF Rapid mode, the meter automatically scan different network segments for ONVIF cameras. It lists the camera name and IP address on the Device List. Tester can auto login camera and display camera image. Click the button “Refresh”, tester will scan the ONVIF camera again. Click the newly displayed ONVIF camera on the “Device List”. The tester will show the IP camera’s relative information and settings.
Enter a new password for the camera. When comes out “activate success” prompt, click login to display camera image. Page.23.
Pop-up settings menu when click the “ONVIF setting” icon in the upper left corner Across network segments scan: After open this function , enter “Setting - IP Settings - Advanced” to add other network segments IP, Rapid ONVIF function can across network segments to scan camera’s IP. Auto Login : After open this function, tester can auto login camera and display camera image.
Click “MENU” icon to open camera setting. While in the “Live video” menu, click “Video Menu” at the top right of the image to access the following tools: Snapshot, Record, Photo, Playback, PTZ and Settings. ONVIF PTZ control: Tap the image in the direction you want the PTZ camera to move. Tap the left side of the image to move left, right to go right, up to go up and down to go down. Compatible IP PTZ cameras will rotate accordingly. PTZ rotation direction is displayed on top left corner of the image.
IP camera video settings: Click “Video Set” to enter the IP camera’s encoder and resolution settings. Make the desired changes and click “OK” to save. Page.26.
Image setting: Click “Imaging Set” to adjust image brightness, saturation, contrast, sharpness and backlight compensation mode. Profiles:Click “profiles”, can view video streaming current configuration files, as well as switch between Major stream and minor stream. Page.27.
Preview pictures:Quickly preview and zoom in or out pictures, automatically and manual refresh. Identification: click “Identification” to view information of the camera. Page.28.
Time set: Click “Time set”, Select "Manual set" to set up the time of camera. Maintenance: For camera software reset or restore to factory settings. Page.29.
User Set: Modify camera user name,password etc parameters. Network setting: Click “Network Set” to change the IP address. Some cameras cannot support change IP address, so there is no change after saving. Page.30.
Zoom in image: Press the key to enter the zoom mode. Press it again to exit zoom mode.When the image is enlarged tap left, right,up or down on the image to move the whole image on the screen. When the image is enlarged, if not operate on touch screen, it can operate by the keyboard,press the key to zoon in , press the key to zoom out ,press upward and downward key to move image.
Snapshot: Click bottom “snapshot” to screenshot the image and store it to SD card. if select manual storage, appears dialog box “Input Name”, user-defined the files name(by Chinese character, English letter or digit ) to save in SD card, if select “Auto- storage”, the tester auto stores the files after snapshot. Record: When you click bottom the “Record” icon, video starts recording. A red recording icon appears on the screen and begins to flash and a timer appears indicating the time elapsed for the video.
To rename or delete a photo, click and hold on the file until this screen appears: Video files can play in the Video player on the main menu. PTZ Set preset position: Move the camera to preset position, enter the preset number on the Bottom right corner to complete position preset. Call the preset position: Select the preset number on the left, click "Call" to call preset. Page.33.
PTZ Speed set: Horizontal and Vertical Speed set. RTSP: Get RTSP address of the current camera. Doc: Auto create testing reports document of camera, click "Create document”. Click Preview to view the report document. Page.34.
Enter the camera test information, click "Create Document" to complete the report. Click “Doc” menu again, you can preview the report document. Icons description: The description of function icons on the bottom toolbar. Page.35.
3.3.9 IP camera test Display image from the 4K H.265 camera by main stream Click icon to enter IP camera test Note: Currently, the IPC Test App only supports some brands’ specific IP cameras, these include specific models made by ACTI, AXIS, Dahua, Hikvision, Samsung, and many more. If the camera is not fully integrated, please use the ONVIF or RTSP apps. IPC test interface Local IP: This is the tester’s IP address. Click “Edit” to enter “IP setting” and change the tester’s IP address settings.
Stream code: When test camera via RTSP, you can select mainstream or sub stream to test (if camera’s RTSP have not been start or without, it will tip “auto match” fail, please witch to manually selecting. IP Camera's IP: Enter the IP camera’s IP address manually or click “Search” to auto-scan for the IP camera’s IP address. It is better to directly connect the IP camera to the tester so the search results will only display the camera’s IP address.
IPC Password: Enter IP camera’s login password. IPC Port: When you select the IP camera type, it will default the camera’s port number and doesn’t need to be changed. After all settings are completed, click “Enter” to view the live video. If IP address setting has error or IP camera is not connected.. The tester prompts “Network Error”. Click to quit from image display and return to IP camera test interface.
(1) Snapshot Click the icon “Snapshot”, when the video in, to take a picture and save the current video frame in the SD card as JPEG file. If the unit is set to the manual mode an “Input Name” pop up box will appear and you can enter a title for the snapshot. If the unit is set up to automatically set file names, this box will not pop up. (2) Video record When you click the “Record” icon, video starts recording.
icon again to stop recording and save the video file to the SD card. If select manual storage, before recording begins, appears dialog box “Input Name”, user-defined the files name(by Chinese character, English letter or digit) to store in SD card , tester will hereby store the files in SD card after recording. if select Auto-storage, tester will auto store the files in SD card after recording. (3)Photo Click the icon “photo” to enter, click the selected thumbnail photo to display it on the screen.
To rename or delete an image, click and hold on the file until this screen below appears Click (4) to close and return to PTZ controller. Recorded video playback Click the “Playback” icon to view your recorded videos. Tap on the video file image you want to watch. Page.41.
To rename or delete a video, click and hold on the file until this screen appears: Video files also can play in the main menu “Video Player". 3.3.11 Video monitor test Analog camera test and PTZ control, click icon to enter Display the input video image, click the top menu bar icon Page.42.
(PEAK level, SYNC level, COLOR BURST measurement) Select relative function on the right side Toolbar to operate , functions including “Photos”, “Snapshot” , “Record” , “Playback” , “PTZ” , “Set” , Click , or press to quit. Click the screen twice quickly, can be full zoom in on the touch screen. (1) PTZ controller parameter setting Select and click icon “PTZ” to enter PTZ setting: A.
D. Address Set the ID according the ID of PTZ camera (0~254), the setting address data must be consistent the speed dome address. E. Pan speed: Set the pan speed of PTZ camera (0~63) F. Tilt speed: Set the tilt speed of PTZ camera (0~63) G. Set preset position (Set PS) Click and select “Set PS”, set and save preset position number(1~128). H.
(2) Video and storage setting Click icon “set” to enter and set analog video image brightness, contrast, color saturation, as well as the file storage way after snapshot and recording, support auto-storage and manual storage. When select manual storage, user can name and store the files. (3) 4 x zoom image display and Video out When image input, press to enter “zoom”, press it again to quit.
If not use touch screen to operate, press the key to zoom out , press the key to zoom in, press upward and downward key to move the image. For analog video input, as the resolution is 720*480, it is normal that the zoom in image is not clear. But for network digital video input, as it supports resolution up to 1280*960, the zoom in image is still very clear. This is very helpful for IP camera installation.
recording. (6)Photo Click the icon “photo” to enter, click the selected thumbnail photo to display it on the screen. Double-tap the image you want to view to make it full screen. Double-click again the photo to return. Page.47.
To rename or delete an image, click and hold on the file until this screen below appears Click (7) to close and return to PTZ controller. Recorded video playback Click the “Playback” icon to view your recorded videos. Tap on the video file image you want to watch. Page.48.
To rename or delete a video, click and hold on the file until this screen appears: Video files also can play in the main menu “Video Player". (8) Video level meter Click the icon to enter, the IP camera tester has adopted hardware high-speed sampling and processing technology, can perform both NTSC and PAL video amplitude signal measurements for PEAK to PEAK, SYNC levels and COLOR BURST chroma level.
While in PAL format, the unit will be mV, While in NTSC format, it will be IRE.
For NTSC format, the Chroma standard level is 40 IRE For PAL format, the Chroma standard level is 280mV If the Chroma level is too low, the color will not be as deep, and some details of the image will become lighter. If the Chroma level is too high, there will be distortions on the image. If the coaxial cable is too long, it will reduce the chroma level.
BNC loop test: Tester can send and receive color bar generator through the tester’s “video out and video in” port, it is for testing transmission channels, such as video Optical, video cables etc. The tester “VIDEO OUT” port to connect optical terminal’s sending port, and “VIDEO IN” Port to optical terminal’s connect its receiving port. A. When maintaining the dome camera, the tester sends out the color bar by its BNC output to the monitor at the monitoring center.
3.3.13 SDI/EX-SDI Camera Test ( *Optional ) SDI camera test, Dome camera test and PTZ control, click icon to enter. When tester receives SDI camera image, it will display the image data. Double-taps on the screen to make the image displayed full screen.
video monitor function, please refer to the relevant instructions “3.3.1” in the manual. Click , or press to quit. 3.3.14 CVI camera test ( *Optional ) HD CVI camera, CVI dome camera test and PTZ control, click icon to enter When HD CVI signal input, the tester will display the image resolution on the top bar. Double-taps on the screen to make the image displayed full screen.
(1)PTZ control 1.1 Coaxial PTZ control Click the icon“PTZ”on the right toolbar to do the corresponding setting. “Port”: select coaxial control Enter PTZ address to perform parameters setting. Operation instructions, please refer to “3.3.1 PTZ (1) Video monitor test”. Page.55.
The PTZ address in the tester must be consistent with the dome camera or decoder, then the IPC tester can test .After setting the parameter, the tester can control the PTZ and lens. To control PTZ by screen touch: Tap left, right, upward and downward on the touch screen to control the PTZ rotation direction, PTZ cameras will rotate accordingly. By two fingers move outward and inward on the touch screen to zoom in and out the PTZ.
Set preset position Setup preset position: Move the PTZ camera to the preset position, then Tap it and input preset position number. Tap “Set position” to complete set preset position. Call preset position Tap the preset position: Tap the preset position area, input preset position number. Tap “call position” to complete call preset position. Page.57.
1.2 RS485 control Operation instructions, please refer to “3.3.1 PTZ (1) PTZ control parameters setting”. (2)Coaxial camera menu setting Tap icon “UTC”, select “menu setting” to enter the dome camera menu. Input calling dome camera menu address code, after finishing the parameter settings, you can press the key or click the icon to call the dome camera menu. Page.58.
Press arrow keys to set. (3) Snapshot, record, photo viewer and video play back, please refer to “3.3.1 PTZ (1) Video monitor test”. Page.59.
Tap “close menu” or press the key “ ” to close camera menu. (4) Save setting Click icon “Set” on the right toolbar to enter storage setting. Support auto-storage and manual storage. When select manual storage, user can name and store the files. Page.60.
3.3.15 TVI camera test ( *Optional ) HD TVI camera, TVI dome camera test and PTZ control, Click icon to enter When HD TVI signal input, the tester will display the image resolution on the top bar. Double-taps on the screen to make the image displayed full screen.
Coaxial camera menu settings Tap icon “UTC”, select “menu setting” to enter the dome camera menu. Input calling dome camera menu address code, after finishing the parameter settings, you can press the key or click the icon to call the dome camera menu. More operation instructions (such as PTZ control, coaxial camera menu setting ,snapshot, recording and playback etc), please refer to “3.3.6 CVI camera test”. Page.62.
3.3.16 AHD camera test ( *Optional ) AHD camera, AHD dome camera test and PTZ control, Click icon to enter When AHD signal input, the tester will display the image resolution on the top bar. Double-taps on the screen to make the image displayed full screen. The tester supports resolution as follows: 1280x720P 25FPS / 1280x720P 30FPS / 1920x1080P 25FPS / 1920x1080P 30FPS/2048x1536P 18FPS/2048x1536P 25FPS/2048x1536P 30FPS /2560x1440P 15 FPS/2560x1440P 25 FPS/ 2560x1440P 30 FPS/2592x1944P 12.
(1) Coaxial PTZ control UTC control : select “PTZ control or PTZ control-2”(AHD camera has two different order ,if select “PTZ” cannot control , pls go “PTZ-2” ) If to coaxial PTZ control the AHD camera, no parameters setting is needed. More operation instructions please refer to “3.3.6 CVI camera test”. 3.3.17 Network tool (1)IP address scan Connect the cable to the LAN port, click icon to enter, Set your IP address search range by changing the Start and End IP addresses.
(2)PING Test Connect a network cable to the LAN port and click the icon to open the PING tool. You can set your LOCAL (native) IP address, Remote IP address (e.g. IP camera), Packet count, Packet Size, Packet time and Timeout. Press “Start” to start pinging. If the IP camera or network device is not configured properly or not plugged in, it will say “Destination host unreachable” or have 100% packet loss. If the tester connects to the device, the send and receive packets will have a 0% packet loss. Page.
Application: PING testing is the most conventional network debugging tools. It is used for testing if the connected. IP camera or other network equipment’s Ethernet port is working normally and the IP address is correct. It’s normal that the first data packet will be lost when test start. (3)Network test (Ethernet bandwidth test) To use the Network tester, you will need two IP testers. One is used as a Server and the other as a Client.
b). Start send packet test: Using the other IP tester, type in the Server's IP address at the top right corner of the screen. This app is used to send packets for network speed testing. Click the “Start” button to send the packets and start testing. Network bandwidth testing can also be tested with a computer using compatible network bandwidth testing software. Install network bandwidth testing software on a computer, as a test Client or Server, to do the mutual testing with the tester.
Tester as Client, tester’s IP address is:192.168.0.238. The Server and the Client are at the same network segment, but with different IP address. Input Server’s IP address 192.168.0.39 in the tester and click “Start” to test network bandwidth. Or use tester as a Server, computer as test Client(select Client, input tester’s IP address to test) Page.68.
When use tester as Server,shows results: (4)Port Flashing Connect a network cable to the meter’s “LAN port”, click the icon to open the Port Flashing app. Click “Start”. The IP tester sends a unique signal to make the connected LAN port of the switch flash. Page.69.
If the tester and PoE switch are connected well, the LAN port of POE switch flash at special frequency, If not, no any changes on the LAN port. Application: The tester will send special signals to make the connected LAN port flicker at special frequency, which will enable the installers to easily and quickly find the connected Ethernet cable. This function can prevent mistakenly insertion or disconnection non-corresponding cable to artificially interrupt network connection. Page.70.
(5)DHCP server Click on the DHCP icon to open the DHCP server app. Select the “Start” check box at the top and make any desired changes to the network settings. Click “Save” to start assigning dynamic IP addresses for IP cameras and other networked devices. Click the “Refresh” button to check your Client list. (6)Trace route It is used to determine path of the IP packet access target.
Click “Start” to trace the goal address. (7)Link monitor Click the icon to open the Link Monitor app. This app is used to see if an IP address is occupied by other network devices. This will avoid new address conflicts. Click “Add ” and enter the desired IP address. To test different network segments, click the “Settings” icon on the main menu and go to IP Settings and make the desired changes. Once the desired IP addresses are added to the Link Monitor list, click “Start”.
Application: Add an IP camera or other network device to the current network group, the new IP address must not be occupied, otherwise it will cause IP conflicts and stop the equipment normal working. Link monitor can check if the new setting IP address is occupied. 3.3.18 Rapid IP Discovery Connect the cable to tester’s LAN port. Press to enter Rapid IP Discovery app. Click “Start” to search all IP address of connected equipment in whole network segment. Click “Stop” to stop work. 3.3.
Note: 1. Don’t input power into the “DC12/2A OUTPUT” port. 2. Don’t output this DC12V/2A power to the DC12V/IN port of the IP camera tester to avoid destroy. 3. The IPC tester power output is close to 2A, if the IP camera’s power is over 2V, the tester will auto enter protection mode. Disconnect all the connections of the tester and then connect the tester with power adaptor to resume the tester. 4. Before turning on the PoE power output, please make sure the IP camera supports PoE power.
3.3.20 Cable Test Click icon to enter Test LAN cable or telephone cable. Connect LAN cable or telephone cable with the CCTV tester and cable tester. And then the connecting status, cable type and the sequence of wires as well as the serial number of the cable tester kit will be displayed. The number of the cable tester is 255 If need several different number other types cable testers, should pay the additional cost.
3.3.21 RJ45 cable TDR test Connect cable to tester’s LAN port, click icon to enter RJ45 cable TDR test app. Single test: Test cable status, length and attenuation. Repeat test: Continue to test cable status, length and attenuation. Status: After link up, screen display “online”, if not link up or open circuit, screen display “open circuit”, if cable pair is short circuit, screen display “short circuit”.
Cable quality test: Green is good quality cable, Yellow is Poor quality cable, Red is water poured cable, the attenuation value will be displayed when cable over 10 meters. Advanced Test: Test cable pair status, length, attenuation, reflectivity, impedance, skew and other parameters.
Connection diagram: Cable sequence diagram: A straight- through and cross-over cable diagram, the cable sequence display for reference. Click “Help”, check the instruction of all parameters. Page.78.
3.3.22Z Cable Tracer Connect test cable or BNC cable to the UTP port or the CABLE SCAN (VIDEO OUT) port on the bottom. Click icon to enter, click the Number on the screen to adjust audio type. Use the blue Combination cable identifier and network cable tester’s copper pointer to touch all the cables in the bundle. You are searching at the other end. The cable that gives off the loudest tone is the cable connected to the tester. Press the + or – buttons on your blue cable identifier to adjust the volume.
Note: The battery of the cable tracer must according to corresponding positive pole + and negative pole -, otherwise will damage the tester. Note: While the cable tracer tester is receiving the audio signal from the tester, it may be influenced by other signals and make some noise. 3.3.
User-defined calibration: Choose the cable 100 meters to 200 meters (more than 50 meters), click “Cable”, “Type” to select user-defined 1 for calibration, 11 groups user-defined can be set. 1.Select user-defined and click “Calibration” to enter test , click “user-defined 1” can define cable name,such as: AiPu BNC-5 2. Click “Cable” , “Type” to select cable, and corresponding type, for example, if testing BNC cable, select “BNC”, if testing communication cable 75-2, select SYV 75-2. Page.81.
3.Click “+” or “-” to adjust wave speed ,while display length is the same with the actual Length ,click “Save” to save calibration data. It can be used for the same cable testing next time. Application: TDR test is used for pulse reflection method, to transmit pulse signal for tested cable, when cable is open circuit or short-circuit, reflected pulse is generated, the tester receives and deals with the reflected wave, measurement results displayed on the screen.
connected etc to cause the different TDR measurement, the TDR measurement is for reference only. 3.3.24 PoE Voltage test Click icon to enter PoE voltage measurement Connect a network cable from a PoE switch to the IP tester’s PSE IN port. Connect an IP camera or other PoE using node to IP tester’s LAN port, the PoE voltage and the cable’s pin connection status show on the screen.
3.3.25 12V power input test Connect 12V power adaptor to tester’s charging port, then click icon “PoE” to enter voltage measurement app, screen show the current adaptor input voltage and power. Note: the current 12V input measured power is the battery charging power and the device working power, the measured power will change depending on the different of battery power and backlight brightness.
3.3.
2) OPERATING INSTRUCTION A. DC Voltage Measuring WARNING! You can’t input the voltage which more than 660V DC, it’s possible to show higher voltage, but it’s may destroy the inner circuit. Pay attention not to get an electric shock when measuring high voltage. a. Connect the black test lead to the “COM ” jack and the red test lead to the “V/Ω” jack. b.Select U, enter the DC voltage measurement. c.
e.Manual range: 0.000V 6.600V range 00.00V 66.00V range 000.0V 660.0V range 000.0mV 660.0mV range C. DC Current Measuring (only manual range ) WARNING! Shut down the power of the tested circuit, and then connect the meter with the circuit for measurement. a. Connect the black test lead to the “COM ” jack and the red test lead to the “mA” jack for a maximum of 660mA current. For a maximum of 10A, move the red lead to the 10A jack.
The maximum current of 10A socket is 10A, over-current will destroy the meter, and will damage the operator. D. AC Current Measuring (Only Manual range) WARNING! Shut down the power of the tested circuit, and then connect the meter with the circuit for measurement. a. Connect the black test lead to the “COM” jack and the red test lead to the“mA” jack for a maximum of 660mA current. For a maximum of 10A, move the red lead to the 10A jack. ~ b.
the operator. In “ AC ” mode, only can input “AC ”, if not, will damage the meter. E. Resistance Measuring WARNING! When measuring in-circuit resistance, be sure the circuit under test has all power removed and that all capacitors have discharged fully. a. Connect the black test lead to the “COM ” jack and the red test lead to the “V/Ω” jack. b.
will sound. G. Diode Testing WARNING! The capacitance of a capacitor should be tested separately, should not test in the installation of circuit. a. Connect the black test lead to the “COM” jack and the red test lead to the “V/Ω” jack. (the red lead anode “+” ) b. to select , enter the diode testing. c. Connect test red lead across to the anode, the black lead to the cathode of the diode under testing. d. Connect test red lead across to the cathode, the black lead to the anode of the diode under testing.
0.000uF 6.600μF range 00.00uF 66.00μF range 000.0uF 660.0μF range 0.000mF 6.600mF range 00.00mF 66.00mF range d. Before connect test leads across two sides of the capacitor under measurement, be sure that the capacitor has been discharged fully. Note: a. The capacitance of a capacitor should be tested separately, should not test in the installation of circuit. b.
Data hold Click “Hold data” to enter, the data be hold, the value is green. Press it again to quit. Relative value measurement Click “Relative” to enter, the tester Auto-save the data, the displayed new measurement and relative value is red color. Press it again to quit. The hold function and the relative value be combined use, the display value is yellow.
Data hold While testing, click “Hold” to data hold, the data will not change. It’s convenient to read. Press again to quit. Relative power value (optical link loss) measurement While testing, set the wavelength for measurement. Click “relative”(difference) to test, the tester Auto save current fiber power value as the base reference value. Input another optical fiber to be measured, the displayed new measurement and relative value is red color. Press it again to quit.
3.3.28 Visual Fault Locator Click icon ( *Optional ) to enter VFL four status can select——“Steady mode”, “Evasive 1Hz”,“Evasive 2Hz”and “ Time off ”. Click button “Steady mode” to enter steady status, click button “Evasive 1Hz” and “Evasive 2Hz”, to enter pulse mode, click button “ Time off ”, VFL is turned off. Timed turn off can select (5 mins, 10 mins, 30 mins, 60 mins and 120 mins). Page.94.
Click” Steady mode”, red laser source emits steady, click again to quit. Click icons “Evasive 1Hz” or “Evasive 2Hz” to enter pulse mode, the red laser source is emitted by a certain frequency, press it again to quit. Page.95.
3.3.29 Audio Record Connect an audio device to the IP tester’s audio input port. Click the icon to enter the Audio Recorder app. Click the red button to stop, and the unit will prompt you to save the recording. 3.3.30 Data monitor Pls click icon to enter Click “Setting” to choose the baud rate of RS485, it must be the same as the DVR or the Control. Keyboard.
3.3.31 Audio player Click the icon to enter. The audio player only supports MP3 format Audio files. 3.3.32 Media Player Click the icon to enter The Media player can browse video and image files. It supports the video formats of MP4, H.264, MPEG4 and MKV. The IP tester recorded files can play directly via the Media player. The Media player will automatically display the video files from the SD card. Click on the desired file to play. Click RETURN to exit.
3.3.33 RTSP Player The RTSP Player app will allow you to view the RTSP video stream from an IP camera. If you were unable to view your camera via the ONVIF or IPC Test apps, it is possible your camera will have an RTSP stream and you can view live video. From the main menu, select the “APP Tool” folder and then select the “RTSP Player” to open the app. If the IP camera uses MJPEG, select the RTSP icon. If the IP camera uses H.264, select the “RTSP HD” icon. Page.98.
Local IP: This is the IP testers IP address. RTSP Add: This is where you can manually enter the IP camera’s RTSP URL or click on Search to search the network for cameras that use an RTSP stream. IPC Username: Enter the IP camera’s user name. IPC Password: Enter the IP camera’s password. Once you have entered all the necessary information, select Enter at the bottom left to view the RTSP stream.
1. Hikvision activation: When connect the unactivated Hikvison camera to the tester, it will auto identify and display “Unactivate” at safety mode. Select needed activate the camera, click bottom right corner button “Enable”, pop-up “the camera have not been activated, activated now”? 2. Input password: Input new password, tap “ok” to activate. Page.100.
3. Confirm activation After activating the camera, the program default modifies the camera IP. Activated multiple cameras in the local area Network, and pop-up menu to modify IP, improve project efficiency. Play: Display image from the camera. Modify network information: Change the camera IP address, sub-net mask and gateway etc. Page.101.
Modify user information: Modify the camera's user name and password. Factory Reset: Camera factory reset 3.3.35 Dahua test tool Dahua test tool is developed for installation and debugging of the Dahua IP camera, it can display image, modify IP, user name and password etc. Making Dahua camera test more convenient and quickly. Page.102.
Click “DH” icon to enter Dahua test tool. Select the camera of the online detection menu, if the camera support non-verification login, you can click “play” directly, and view the image. Page.103.
Pop up stream menu, select Mainstream or Substream to test. If the camera not supports non-verification login, pls select “camera” of online detection menu, and input correct user name and password, then click “log in”. After logging successful, you can test it. Play: Select Mainstream or Substream, IP camera live video display. Page.104.
Modify network information: Modify camera parameter, such as ip address, subnet mask, gateway etc. Modify user information: Modify camera user name and password, which is onvif, Dahua test tool, IPC TESTE user name and password, not web user name and password. Factory reset setting: Camera will be soft reset, and the device’s user name, password and network set be saved. Other settings information is factory reset. Page.105.
3.3.36 Update Copy the downloaded update file to SD card "update" directory, if no directory, please create one. Click the icon to open the Update menu. Select “Local Update” to update via the SD card or select “Online Update” to check for updates on the internet. If there are applications that need updating, the applications will be displayed on the screen. If there are update programs, applications will be listed in the interface, click related applications, update to the latest version. Page.106.
3.3.37 Office Quick office app (support excel, word, ppt format) doc. editable 3.3.38 LED Flashlight It is convenient for the installation or maintenance in the evening or in the dark. Click icon to enter. While in the flashlight app, click the red button to turn on the LED lamp. Press it again to turn it off. If you don’t press the red button to shut off the lamp and press the button to exit the app, the lamp will stay on. Click the Time Setting button to set a timer that will shut off the lamp.
3.3.39 Browser Click icon to enter Type in the camera’s IP address and press “Go” to access the IP camera’s interface. NOTE: You will not be able to view live video in the web browser. For viewing video, use the IP tester’s live camera view Apps. The IP camera and IP tester be on the same network segment for the browser to interface with the camera. If they are not in the same segment, click the button or press “RETRUN” to exit.
pls click to view the notepad , all saving contents display. Click each record bar to show the details. Press the record bar for several seconds, prompt whether delete it. 3.3.41 System Setting Click icon to enter Language: Select your desired language: English, Chinese, Korean, Russian, Italian, Polish,Spanish, French or Japanese. Page.109.
Typewriting: You can select typewriting or install other typewriting: Date/Time: Set the Date/time of the IP tester. IP setting: Manually set the IP address, Sub-net Mask, Default Gateway and DNS address or select “Dynamic allocation” to use DHCP. To test multiple network segments, click “Advanced ” and then click “Add ” to enter another IP address for the IP tester. After setting an advanced IP address (refer to the photos above), the unit can test two network segments (192.168.5.0) and (192.168.1.0).
Select and press “WIFI” several seconds, to set static IP address. Wi-Fi hotspot: input “SSID” name and “password”, and then click “ok” to create Wi-Fi hotspot. Page.111.
Brightness: Set the desired brightness of the IP tester and adjust the sleep time settings. Volume: Set volume level. SD Card: Displays SD Card Capacity. You can also format the SD card or unmount it before removing it. FTP server: Once the IP tester connects to a network, a computer can be used to read the SD card files via FTP. Start the FTP server and then input the tester’s FTP address in the PC’s address bar.
Screen display rotation: Click on “Screen Rotation” to flip the IP tester’s display 180 degrees. This function is very convenient for the user to connect the LAN cable on the bottom of the unit without having to flip the unit itself. PTZ address scan: You can toggle the PTZ Address scan off or on before entering the “PTZ controller” app. This needs to be turned on in order to use the PTZ Scan feature of the PTZ app.
Browse It includes Music, Videos, Pictures, Documents, zip file etc. It is convenient to view and manager. FTP server You can choose internal or external SD card. Other operation details, Pls refer to FTP settings. Page.114.
3.3.43 Theme Click Theme icon to enter themes setting. Desktop style : You can select Lite mode or normal mode. Theme: Pressing square area’s any color icon several seconds, the selected color icon will be auto move the rectangle area, if you press selected color several seconds, and it will be auto deleted. Theme colors include fixed order and random order, and click “set” to save. Page.115.
Color When set background color, you can select colors from Color Phase, and also can input color’s RGB to set. After finished color setting, click “set” to set it as desktop or application background. Set as desktop background: Setting color as desktop background. Set as application background: Set color as application background. Set at the same time: Setting color as desktop background and application background. Cancel: Cancel current setting. Page.116.
Picture: Click Picture to select one, and set as temporarily background to view setting effect. Click “more” to select pictures from local file, and click set to set picture as background. Sliding effect: Tester’s sliding effect includes stereo effect, folding effect, Left and right folding, rotate effect, Gradual effect etc, selecting one of effect to view slide effect in the square area, and click “set” to save. Page.117.
3. 4 Audio test You can test the audio input from audio pickup devices by connecting the audio pickup device to the IP tester with the supplied audio cable. 3.5 HDMI output The built in HDMI output port can output live video from an analog or IP camera, recorded files, media files and images to HDTV monitors. Connect an HDMI cable from the IP tester to an HDTV monitor at any time. It supports up to 1080P resolution. 3.
c. The instrument’s PoE maximum power output is 24W. If Ultra- high-power load happens, the tester will enter protection mode . 3.7 DC12V 2A power output When the IPC tester is turned on, the DC 12V power output ON by default. The smaller end of the supplied converter cable connects to the tester’s DC12V/2A OUTPUT and the other end connects to the camera’s power input. Application Power output function is mainly used in the camera field demonstration and testing, meanwhile, for Page.119.
some cameras installation sites, If there is no power outlet for the adapter to power the camera, the tester can offer temporary power for it. But we do not suggest tester supply power for a long time. Notice: a. Don’t input any power into the “DC12/2A OUTPUT” port of the tester. b. Man-made damage is not within our company’s warranty. c. The IP tester’s power output capacity is 2A. If the IP camera uses more than 2A, the tester will automatically enter a protection mode. d.
4. Specifications 4.1 General Specifications Model Display Network port IP Camera Tester【*】models Optional New 7 inch retina touch screen cctv tester ,1920*1200 resolution 10/100M auto adjust, RJ45 Built in WIFI,speeds 150M, allows you to connect to a wireless network WIFI and view IP cameras H.265 Mainstream test New hardware decoding,4K,H.265/H.
(Optional) 25,30,50,60fps/ 1080p 25,30fps/2560x1440p 25fps,30fps, UTC control and call OSD menu 1 channel TVI input(BNC interface), resolution support 720p TVI video signal test (Optional) 25,30,50,60fps/ 1080p 25,30fps /2048x1536p 18,25,30fps, 2688x1520p 15fps , 2560x1944p 12.5,20fps, UTC control and call OSD menu 1 channel AHD input(BNC interface), resolution support 720p 25,30fps / AHD video signal test 1080p 25,30fps/2560x1440p 15,25,30fps/2560x1944p 12.
video cable.(red, green ,blue, white and black color) Test UTP cable connection status and display on the screen. Read the UTP Cable tester number on the screen Captures and analyzes the command data from controlling device, also can Data monitor send hexadecimal IP address scan, link scan, and Ping test.
Working -10℃---+50℃ Temperature Working Humidity 30%-90% Dimension/Weight 255mm x 160mm x 46mm / 0.95Kg 4.2 Multi-meter specifications Counts:-6600~+6600 Conversion rate: 3times/s Current modes for clamp meter with ZERO function Isolation: the Multi-Meter connector must be isolated with the other connector. DC voltage Range Accuracy 660mV (Manual range) Resolution 0.1mV 6.600V 1mV ±(0.3%+4) 66.00V 10mV 660.0V 100mV AC voltage Range 660.0mV (Manual range) Accuracy ±(1.5%+6) 6.600V 66.
Range Accuracy Resolution 6.600mA 1uA 66.00mA 10uA ±(0.5%+3) 660.0mA 100uA 10.00A ±(1%+5) 10mA AC current Range Accuracy Resolution 6.600mA 1uA 66.00mA ±(0.5%+3) 10uA 660.0mA 100uA 10.00A ±(1%+5) 10mA Resistance Range Accuracy 660.0Ω Resolution 0.1Ω ±(0.8%+5) 6.600KΩ 1Ω 66.00KΩ 10Ω ±(0.8%+2) 660.0KΩ 100Ω 6.600MΩ 1KΩ 66MΩ 10KΩ ±(1.2%+5) Continuity Range Resolution 660.0Ω 0.1Ω Function The measurement value less 30Ω±3Ω,the tester will sound Page.125.
Diode Range Resolution Function Schottky diode:0.15~0.25V 2.0V 1mV rectifier diode:0.6~1.0V triode PN junction:0.5~0.8V Capacitance Range 6.600nF Accuracy Resolution 1pF ±(0.5%+20) 66.00nF 10pF 660.0nF 6.600μF 100pF ±(3.5%+8) 1nF 66.00μF 10nF 660.0μF 100nF 6.600mF 1μF ±(5%+8) 10μF 66.00mF 4.
Operating Temperature(℃) -10~+50 Storage Temperature (℃) -20~+70 FC/PC Connector type 4.4 Visual fault locator specifications Laser type LD Wavelength Calibration 650nm Output power 5mW(Optional 10mW, 20mW) Modulation mode CW/1Hz/2Hz Measurement Range 5KM(Optional 10-20KM) Connector FC/PC exchangeable Working Temperature -10℃~+50℃ Operating Temperature -20℃~+70℃ The data above is only for reference and any change of them will not be informed in advance.