CAM520 User Manual
FCC NOTICE (Class A) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Federal Communications Commission Statement NOTE- This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
COPYRIGHT © 2016 AVer Information Inc. All rights reserved. All rights of this object belong to AVer Information Inc. Reproduced or transmitted in any form or by any means without the prior written permission of AVer Information Inc. is prohibited. All information or specifications are subject to change without prior notice. NOTICE SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. THE INFORMATION CONTAINED HEREIN IS TO BE CONSIDERED FOR REFERENCE ONLY.
Contents Package Contents ............................................................................................................................ 1 Product Introduction ........................................................................................................................... 2 Camera ....................................................................................................................................... 2 Remote Control.....................................................
Package Contents 1 2 3 5 6 7 1. CAM520 5. USB cable 2. Mount (mounting screws are included) 6. User Manual 3. Power Cord* & Power adapter 7. AAA Batteries (x2) 4. Remote Control 4 * The power cord will vary depending on the standard power outlet of the country where it is sold.
Product Introduction Camera 1. IR Sensor 5. Power Jack 2. Power indictor 6. Kensington lock 3. RS232 connection* 7. Screw hole for mounting 4. USB port * If you need a converter or instructions on how to use RS232, please contact AVer USA.
Remote Control 1 9 2 3 4 10 5 11 6 12 7 8 13 Name 1. Camera select 2. Camera direction control 3. FaceLumi Function One remote can control up to 3 AVer VC/Cam. Please use the AVer PTZApp to set cameras to buttons 1 to 3. Once set, camera may be selected by a simple press of the camera select button. Position of the camera lens may be adjusted through the direction buttons. Long press of the button allows continuous pan or tilt of the camera.
Name Function 8. Call/answer* Answer a call or start a call. 9. Enter** To confirm the selection in the OSD menu. 10. Mute/Unmute Speakerphone Mute/Unmute the speakerphone. 11. Volume up/down Adjust volume up or down. 12. Far site camera control Press the Far/Near button to control the far site camera for pan, tilt, or zoom functions. 13. Hang up* End the call. * Function requires AVer PTZApp. ** Only support on CAM530. [Note] Volume control and mute buttons are not applicable to CAM520.
Setup CAM520 Device Connection Wall outlet Camera Power cable PC USB cable Laptop 1. Use USB cable to connect the CAM520 to your PC/laptop (refer to diagram above). 2. Connect the power to the CAM520; power indicator will light up and camera head will rotate. 3. Install AVer PTZApp on laptop or PC that is connected with CAM520. The app can be used to adjust and setup the parameters of the camera (refer to section of AVer PTZApp) 4.
Mounting Camera There are 3 ways to mount the camera – on the wall, on the ceiling, and on a table with the mount and screws included in the package. [Warning] 1. When securing the camera mount on a wall or celling, only use hardware and materials certified to support 22 lb (10 kg) weight. For dry wall installation, please use Sleeve-Type Hollow Wall Anchors (a.k.a. Molly Bolts). 2.
Table Use CAM520 Make a Video Call 1. Make sure CAM520 and PC/laptop are well connected and power is on. 2. Run your video application (SkypeTM, Microsoft ® LyncTM, Google HangoutsTM, Cisco WebEx® , GoToMeetingTM, WebRTC, and etc.) on your PC or l laptop. 3. Set the CAM520 camera as the primary camera for your video application (refer to your video application user guide). You can now make your call. 4. The CAM520 is a plug-and-play conference camera.
AVer PTZApp Install AVer PTZApp Please go to http://www.aver.com > Support > Download Center > Video Conferencing to download the AVer PTZApp. After downloading, double-click on the file and follow the on screen instructions to complete the installation. Remember to select the “Skype plug-in” option during installation. After installing the AVer PTZApp, double-click on the AVer PTZApp icon to run the application. Use AVer PTZApp 1.
a. Function icon: Click it to switch to the function’s page. - PTZ: To control the camera direction, zoom in and out, and to enable/disable the backlight compensation during your video call. - Settings: To setup parameters of the camera – White balance, noise filter, frequency, brightness, sharpness, flip, mirror, ADDR, baud rate, H.264 stream, and numeric key control. ADDR and baud rate is for RS232 connection setting. Click the Save button to save all settings.
- Diagnostic Utility: To display the S/W and F/W version and the devices connection status. You can also update the firmware of the camera. b. Minimize: Minimize the app to system tray. To quit the application, right-click the icon on the system tray and select “Quit”. c. (Camera): Click it to view the camera live view. Click the camera icon again to close the camera live view.
d. Connection diagnostic: Display devices connection status. If the AVer PTZApp has detected that camera and laptop/PC are not connected well, the diagram will display an “X” on the camera to indicate the connection has a problem. If the camera is in use by another application, it will display “Can’t start video” warning. e. Test Camera: Click the “Test Camera” to check the camera video display status. You can adjust the camera direction and view of the zoom in/out.
f. Update Now: Allows the user to update the CAM520 camera’s firmware. 1. Click” Update Now”. 2. A dialog will display the current firmware version and available new firmware version (internet connection is required). 3. To auto update, click “Auto Update” and update process will start. The new firmware will be downloaded first; then, the new firmware will be uploaded to camera. [Note] Please make sure camera, power, and laptop/PC are all well connected and stay connected during the entire process.
Select Remote Control CAM520 supports two different remote controls. Please select your remote.
Set the Camera Number With multiple cameras connected, users can set each camera to buttons 1 to 3 on remote control. 1. If PTZApp detects computer connects to multiple VC/CAM, you can select which camera you like to control through the dropdown list. 2. Next, Click Change Binding button. 1 2 3. Select which camera number of remote control it maps to. 4. Click Save to save settings. To un-save the settings, click Abort.
Hotkey Control Enable hotkey control to use keyboard control camera’s movement and backlight. 1. Selet “Settings” 2. Set Hotkey Control to “On”. 1 2 3.