PA1000 - Overhead Garage Door Operator Instruction Manual (Notice D’exploitation) FOR RESIDENTIAL USE ONLY Part Number #40020 Model: PA1000V1 October 2011 www.bnd.com.
WARNING: It is vital for the safety of persons to follow all instructions. Failure to comply with the installation instructions and the safety warnings may result in serious personal injury and/or property and remote control opener damage. Please save these instructions for future reference. AVERTISSEMENT: pour la sécurité des usagers, il est essentiel de suivre toutes les instructions.
PA1000 Instruction Manual (Instructions d’installation) CONTENTS PA1000V1 Overhead Garage Door Operator Safety Rules 05 System Specifications 06 Default Settings and Technical Specification 06 About Your Operator 07 Operating Controls 08 Kit Contents 10 Installation Knockdown C-Rail Assembly 12 C-Rail Assembly 13 Mounting Operator for Track Type Door 14 Mounting Door Bracket & Arms 15 Safety Beam I
PA1000 Instruction Manual (Instructions d’installation) CONTENTS PA1000V1 Overhead Garage Door Operator How to Use Your Operator Remote Control Transmitter 26 In-Build Locking 27 Manual Door Operation 27 Power Failure 27 Removing Transmitter Battery 27 Safety Beam Option 28 Auto-Close Option 28 Courtesy Light 28 Auxiliary Output 28 Vacation Mode 28 Pet Mode 28 Service 28
PA1000 Instruction Manual (Instructions d’installation) Safety Rules (Les règles de la sécurité) Please read these important safety rules These safety alert symbols indicate a personal safety or property damage instruction exists. Read these instructions carefully. This automatic garage door operator is designed and tested to offer safe service provided it is installed and operated in strict accordance with the following safety rules.
PA1000 Instruction Manual (Instructions d’installation) System Specifications Factory Default Settings Default Step Maximum Maximum motor run time 30 Secs. - - Courtesy light time 3 Mins. approx. - - Obstruction force margin 2 1 14 Auto close time 30 Secs - - Technical Specifications Input Voltage 120Vac / 60Hz Fuse (primary) 1.
PA1000 Instruction Manual (Instructions d’installation) About Your Operator Thank you for choosing a PA1000 automatic garage door operator. Courtesy Light The technically advanced construction of this operator ensures you enjoy the following benefits: The courtesy light automatically switches on for approximately three (3) minutes when operating the door. This can also be programmed to turn on and off from a transmitter.
PA1000 Instruction Manual (Instructions d’installation) Operating controls 01. Terminal is used to connect Vac to the control board. 02. 10 Amps fuse to protect the electronic circuit board. 03. This connector is used to connect Battery Charger SBC02 to the opener. 04. DC 24V motor connects to this connector. 05. Operate (blue) Button is used during installation to test the open, stop and close cycles for the opener.
PA1000 Instruction Manual (Instructions d’installation) 9 Operating controls 05 04 06 03 02 01 07 16 15 Fig.01 08 09 10 14 11 13 12 01. 02. 03. 04. 05. 06. 07. 08. 24V power input connector. 10Amp fuse. SBC02 Battery Backup Connector Motor connector OPERATE (Blue) button Plus (+) (Green) button PG-3 Programmer connector Open Limit LED 09. 10. 11. 12. 13. 14. 15. 16.
PA1000 Instruction Manual (Instructions d’installation) Kit contents: Powerhead Drive Unit Kit (Fig.02). Fig.02 1 X PA1000 drive unit; 1 X Handheld Transmitter with battery; 1 X Wall mount Transmitter with battery; 2 X Door attachment arms; 1 X Accessory and hardware pack. PLUS Single Piece Track With Pre-Assembled Chain (Fig.03) Fig.03 NOTE: Chain in one piece rail has been tensioned by the factory. Do not adjust the tension of the chain.
PA1000 Instruction Manual (Instructions d’installation) 11 Kit contents: OR Multi-Piece Knockdown Track with Pre-Assembled Chain (Fig.05) IMPORTANT NOTE: If modification to the track length required, adjustment must be made only from power head End. Fig.05 OR Multi-Piece Knockdown Track With Pre-Assembled Timing Belt (Fig.06) Fig.06 IMPORTANT NOTE: If modification to the track length required, adjustment must be made only from power head End.
PA1000 Instruction Manual (Instructions d’installation) Knockdown C-Rail Assembly Step 1 Unpack and assemble the C-Rail as shown above in Fig.07. Fig.
PA1000 Instruction Manual (Instructions d’installation) 13 C-Rail Assembly Step 2 Locate and insert the shaft of drive unit into sprocket as shown in Fig.08. Shaft Fig.08 Locate shaft into sprocket 4 Taptite screws ‘S’ M4 X 10 Step 3 Fix the two track brackets with four screws supplied in accessory pack as shown in Fig.09. 2 P1 sV ket rac b ck Tra Fig.
PA1000 Instruction Manual (Instructions d’installation) Mounting Operator for a Track Type Door Step 4 - Determine Bracket Position Level Track Fig.10 Door Open the door and find the highest point of travel of the top door panel. Using a level, transfer this height to the wall above the door (Fig 10) and mark a line 0.197” (60mm) above it. Determine the centre point on the wall above and on top of the door. Then draw two lines 0.0705” (21.5mm) on each side of the centre point (Fig.11).
PA1000 Instruction Manual (Instructions d’installation) 15 Mounting Door Bracket and Arms Drill hole at centre of track (recommended bolt size M6 or M8) Step 8 - Alternative Mounting Option The operator can be fastened to the roof by drilling a hole in the centre of the C-Rail and driving a bolt through it into structural timber support. The height of bolt head must not exceed 0.24” (6mm) (Fig.14).
PA1000 Instruction Manual (Instructions d’installation) Safety Beam Installation IMPORTANT NOTE: The Safety Beam must be installed and connected before the travel limits are set. 5 3 4 Step 15 - Safety Infra-Red Beam A Safety Beam extends across the door opening. This Safety Beam is designed to detect an obstruction while the door is closing and to send a signal to the door operator to reverse or stop the door movement. Fig.17 6 1 2 Step 15.1 - Fitting the Safety Beam 5 a. b. c. d.
PA1000 Instruction Manual (Instructions d’installation) 17 Setting Speed and Limits Step 16 - Setting Speed Mode The default speed of the operator has been set to suit the majority of applications. However, there are 3 speed modes available if required: 1. 2. 3. SLOW - suits one piece door without tracks. MEDIUM (default) - suits majority of applications. FAST - suits some special applications. Fig.20 The speed settings can only be changed before setting the travel limits.
PA1000 Instruction Manual (Instructions d’installation) Setting Speed and Limits IMPORTANT NOTE: The operate button will not function until the open and close limits positions are set. Step 17 - Setting Travel Limits Fig.21 NOTE: The door and shuttle must be engaged into the chain/belt index. The door should be open approximately half way. Remove the controls cover (Fig.20) to access the controls panel and place it back when finish programming. 17.1 - Setting Limits Positions (Fig.21) 1.
PA1000 Instruction Manual (Instructions d’installation) 19 Testing Safety Obstruction Force CAUTION: Please take care when testing the safety obstruction force. Excessive force may cause serious personal injury and/or property damage can result from failure to follow this warning. 18.1 - Testing the Close Cycle 1. Press the OPERATE button to open the door (Fig.23). 2. Place an object approximately 1-1/2”(38mm) high (or a 2”x 4” board laid flat) on the floor under center of garage door opening (Fig.24).
PA1000 Instruction Manual (Instructions d’installation) Setting Safety Obstruction Force Adjusting Safety Obstruction Force Fig.25 The safety obstruction force is calculated automatically and set in memory on the operator. It is usually not necessary to adjust the safety obstruction force. The only time the force may need to be increased is due to environmental conditions, for example, windy or dusty areas, and areas with extreme temperature changes.
PA1000 Instruction Manual (Instructions d’installation) 21 Coding Transmitters Step 19 - Setting Transmitters Codes The garage door operator can only operate from remote control transmitters that have been programmed into the opener’s receiver. The receiver needs to learn the codes of any remote control transmitter that will be used with the operator. Up to 14 codes can be stored in the receivers memory. 19.1 - Storing the Transmitters Code (Fig.28) 1. 2. 3. 4. 5.
PA1000 Instruction Manual (Instructions d’installation) Coding Transmitters 19.3. Setting the Transmitter to Operate Vacation Mode Fig.30 Press Code set Button three times Select one of the four buttons (not programmed yet) that you wish to use to control the Vacation Mode Fig.31 The opener can be programmed into a “Vacation Mode” where the operator will not respond to any transmitter except one programmed unit. 1. Press CODE SET button three times.
PA1000 Instruction Manual (Instructions d’installation) 23 Coding Transmitters 19.5 - Setting the Transmitter to Operate Pet (Pedestrian) Mode (Fig.32) The opener can be programmed into a “Pet Mode” where the door opens partially to allow pet to enter/exit the garage. 1. 2. 3. Press CODE SET button five times. The CODE SET LED will illuminate and the courtesy light will flash quickly (twice per second) to indicate that the learning mode for “Pet Mode” is active.
PA1000 Instruction Manual (Instructions d’installation) Accessories Terminal Block V+ EB1 OV Fig.35 EB2 0V OSC AUX A variety of wired accessory items can be connected to the terminal block J4 such as Safety Beam, Electric Key Switch and more (Fig. 35). Terminal connections from top down are as follows: 1. V+ (+35V/+24V); 2. EB1 (Safety Beam input, mandatory); 3. 0V (0V for Safety Beam); 4. EB2 (Safety Beam input); 5. 0V (Common ground for accessories and Safety Beam); 6.
PA1000 Instruction Manual (Instructions d’installation) 25 Battery Backup Installation (Optional) Fig. 37 Battery Back Up (optional) The operator has provision for a Battery Back Up kit that allows continued operation of the door in the absence of mains power. Testing Battery Back Up 1. 2. Installation 1. 2. 3. 4. 5. 6. 7. 8. Disconnect power to the operator. Remove screws and swing open the cover (Fig 37). Mount the PCB support with two screws item # 12.
PA1000 Instruction Manual (Instructions d’installation) How to Use Your Operator For maximum efficiency of your operator, your garage door must be in good operating condition. An annual service of your garage door by an authorised dealer is recommended. CAUTION: Activate the operator only when the door is in full view, free of obstructions and with the operator properly adjusted. No one should enter or leave the garage while the door is in motion. Do not allow children to play near the door.
PA1000 Instruction Manual (Instructions d’installation) 27 How to Use Your Operator In-built Locking Facility DO NOT lock your door with the locking bars when your operator is engaged. This operator has an in-built locking facility. With the operator engaged your door will be locked whether the power is on or off. Manual Door Operation CAUTION: When operating the manual release while the door is open. It may fall rapidly due to weak or broken springs, or an improperly balanced door.
PA1000 Instruction Manual (Instructions d’installation) How to Use Your Operator Safety Beam Option A Safety Beam Kit must be fitted to this operator. • When this Kit is fitted, the operation of this device is such that if an object (i.e. car, child, etc.) blocks the Safety Beam, then the garage door opener will not close the door automatically. • When the Safety Beam is fitted but not operating correctly, then the door once opened automatically, will not close automatically.
PA1000 Instruction Manual (Instructions d’installation) Maintenance The Service LED will indicate the requirement for a service and/or adjustment. To reset the Service LED when the door is serviced, reprogram the Door Travel Limits and the Door Travel Force – on completion of this programming the Service LED will go out. CAUTION: Frequently examine the installation, in particular cables, springs and mountings, for signs of wear, damage or imbalance.
PA1000 Instruction Manual (Instructions d’installation) Troubleshooting Guide Symptom Possible cause Remedy The opener does not work from the hand remote control transmitter Garage door in poor condition e.g. springs may be broken Check the door for normal operation – see monthly maintenance. The opener does not have power Plug a device e.g. a lamp, into the power point and check that it is OK.
PA1000 Instruction Manual (Instructions d’installation) Parameters Door status indicators Door opener state Open LED green Open On Close Opening Close LED red Door status LED yellow Beeper On Flashing Closing Flashing Door travel stopped Flashing Door obstructed when opening Flashing Door obstructed when closing Flashing Flashing Opener overloaded Alternating flashes Door in open position with autoclose mode selected One second flashes Mains power interrupted Rapid flashes Beeps whi
PA1000 Instruction Manual (Instructions d’installation) Spare Parts List
PA1000 Instruction Manual (Instructions d’installation) © Copyright 2011 Diamond PD Power Drive : Instruction Manual 33
PA1000 Instruction Manual (Instructions d’installation) Warranty 1. Definitions 2. .
PA1000 Instruction Manual (Instructions d’installation) Warranty Purchased From: Installed By: Installed Date: The Purchaser shall complete this certificate and keep it together with a copy of the receipt of purchase in a safe place – production of such information will assist the handling of a claim made under this warranty.
PA1000 Instruction Manual (Instructions d’installation) Optional Accessories There is a range of additional accessories for your convenience and security. • Safety Infra-Red Beams - Gives additional protection if the door is closing onto your property or person. Simply breaking the beam “stops” the door! Must be fitted if auto closing feature is operational. • Keyring remote control transmitter - Ideal for personal use when entry into the house may be via the garage.
PA1000 Instruction Manual (Instructions d’installation) © Copyright 2011 Diamond PD Power Drive : Instruction Manual 37
©Copyright October 2011. All Rights Reserved. www.