AUTOMATIC TECHNOLOGY AUSTRALIA PTY LTD Elite SWING GATE OPENER OWNERS COPY Installation Instructions Warning: It is vital for the safety of persons to follow all instructions. Failure to comply with the installation instructions and the safety warnings may result in serious personal injury and/or property and remote control opener damage. Please save these instructions for future reference.
CONTENTS PAGE CONTENTS 4..... 5..... 6..... 7..... 9..... 9..... 10... 11... 12... 13... 14... 15... 17... 18... 19... 19... 20... 20... 21... 22...
IMPORTANT SAFETY INSTRUCTIONS Warning - It is vital for the safety of persons to follow all instructions. Failure to comply with the following Safety Rules may result in serious personal injury and/or property damage. For ADDITIONAL SAFETY protection we STRONGLY recommend the fitting of a Photo Electric Beam. In most countries Photo Electric Beams are mandatory on all gates fitted with automatic openers.
FEATURES Thank you for purchasing the ATA Elite Swing Gate Opener. This opener is designed to suit residential hinged swing gates. The components and materials used in this opener are of the latest technology and highest quality. Listed below are some of the many features. DUAL LEAF GATE A dual leaf gate can be controlled with the addition of a second drive unit. Mains power is only required for the control box and a 5-core low voltage cable for the drive units.
Kit Contents CONTROL BOX The control box contains the control board, capable of driving either a single or dual leaf gate, a remote control receiver and transformer. When used with suitable cable glands, it is designed to meet the IP56 weather proof rating. DRIVE UNIT The Drive Unit consists of a 24V DC motor, a rugged gear box and a cam activated limit switch assembly. Each drive unit is supplied with a pair of arms, arm bracket plus arm assembly hardware. ITEM 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13.
DRIVE UNIT INSTALLATION The ATA Elite swing gate opener is designed to operate most residential swing gates. The gates must be in good working condition and should operate by hand relatively freely. Wind loading may affect the operation of the opener in high wind areas. Correct obstruction and reversing settings should be chosen for trouble free operation. 2. The pier or post for mounting must be of solid construction (Brick, solid timber or steel). It must bare most of the force applied by the drive unit.
DRIVE UNIT INSTALLATION MOUNTING DRIVE UNIT 1. Mount drive unit using four (4) 10mm loxins or dynabolts. 2. Make sure that the Drive Unit is mounted at an appropriate height from the ground - allow minimum 35mm clearance for drive arm extension. FIG. 3 PULL RING TO DISENGAGE MOTOR NOTE: If the gateway slopes away from pier/post make sure an allowance is made for clearance of the drive arm extension and slave arm to not touch the ground.
INSTALLING DRIVE UNIT ARMS FIG. 5 AFFIXING ARMS AND BRACKETS TO GATE 1. Position gate in close position. 2. Attach drive arm extension to drive arm (fixed to the drive unit) (Fig. 1), using two (2) Hex. Head screws and spring and flat washers supplied. 3. Attach slave arm to drive arm extension using plastic washers and shoulder screw supplied. (see Page 6). 4. Assemble Gate Mounting Bracket and Slave Arm using shoulder screw and plastic washers, do not tighten yet. 5.
MOUNTING CONTROL BOX MOUNTING CONTROL BOX FIG. 8 CAUTION: DO NOT USE ANY CABLES WHICH CARRY GREEN/YELLOW WIRES AS THIS SIGNIFIES EARTH, AND DOES NOT COMPLY WITH ELECTRICAL AUTHORITY REGULATIONS. The control box should be mounted near the drive unit using four (4) 6mm screws. 1. Drill holes as per (Fig. 8). When locating the control box allow ample space around the unit for easy access and wiring connections. 2. Remove cover from control box. 3.
ELECTRICAL CONNECTION - SINGLE LEAF FIG. 10 SINGLE LEAF INSTALLATION Motor on Left Side FIG.
ELECTRICAL CONNECTION - DUAL LEAF FIG. 12 DUAL LEAF INSTALLATION Left side opens first FIG.
SETTING OBSTRUCTION FORCE CHECKING LIMITS POSITIONS WARNING: If gates require sync delay - Switch 1 must be set to ON before fine tuning limits. 1. Re-engage drive units. 2. Press OSC to move gate until the limit switch engages. 3. Fine tune limts cam positions so that the gate reaches the desired open and closed positions. NOTE: In the pre-initialised state the OSC button moves the gate only while depressed. INITIALISATION 1. Engage the motor assembly (Fig. 3 & 4), switch power on at power point.
CONTROL BOARD LAYOUT FIG. 14 1. COMMON TERMINAL FOR (2) TO (7) BELOW. 2. PHOTO-ELECTRIC SAFETY BEAM INPUT (N/C). 3. OPEN CONTROL INPUT (N/C). 4. STOP CONTROL INPUT (N/C). 5. CLOSE CONTROL INPUT (N/O). 6. OPEN/STOP/CLOSE CONTROL INPUT (N/O). 7. PEDESTRIAN ACCESS CONTROL INPUT (N/O). 8. MOTOR 1 TERMINALS. 9. MOTOR 1 LIMIT SWITCH INPUTS. 10. MOTOR 2 LIMIT SWITCH INPUTS. 11. MOTOR 2 TERMINALS. 12. 24V DC SUPPLY OUTPUT (TO ACCESSORIES). 13. ELECTRIC LOCK CONTROL TERMINALS. 14.
MODE SELECTION AUTO-CLOSE MODE Auto-close mode automatically closes the gate after a preset time once the gate has reached its desired open position. The controller starts to close the gate when the count down has expired. The timer can be suspended by activating a suspending input (which inputs 'suspend' depends on which auto-close mode is selected). When the input is deactivated the auto-close timer is reset and the count down recommenced. Auto-close functions are temporarily disabled by certain actions.
MODE SELECTION If the P.E. input is configured to stop the gate during opening or closing, then the gate can auto-close from a midway position. This feature is implemented so that once a vehicle has entered the gateway and broken the P.E. beam, the gate will stop. When the P.E. beam is cleared the gate will auto-close from the stopped position. This results in the gate not having to fully open and thus reducing the time unwarranted access through the gate is possible.
CODING TRANSMITTERS CODING TRANSMITTERS INTO RECEIVER Transmitters can be programmed into the gates receiver to do two functions: the full Open/Stop/Close cycle, and partly open gate for PEDestrian access. The memory in the receiver can store up to 30 different remote control transmitters. FIG. 15 Note: Make sure to connect the battery to the transmitter in the correct polarity. STORING TRANSMITTER CODE FOR O/S/C 1. Press and hold the SW1 button on the receiver (Fig. 15). 2.
ACCESSORIES CONTROL AND SAFETY INPUT TERMINALS Fig. 19 shows the control and safety input terminals and their switch contacts. Note that the P.E., OPN and STP inputs require a normally closed contact, which is provided by the shunts (Fig. 14 and Fig. 19). The appropriate shunt must be removed when the P.E, OPN or STP inputs are used. The CLS, OSC and PED inputs require a normally open momentary contact. FIG. 19 ATA Photo Electric Beam - Order Code: 90214 LOCK RELEASE OUTPUT FOR SOLENOID LOCKS Fig.
BATTERY BACK UP An optional battery backup system is available so that the gate can be operated (for a limited time) in the event of mains power failure. When the backup system is utilised, the control board detects the presence of mains voltage. If mains power fails the control board switches to the backup supply provided by a 24V DC battery. When mains power is restored the control board switches back to mains supply. The following items are required to use the battery backup system: 1.
TROUBLE SHOOTING Gate does not open or close Check that power is still available at mains power point. Check that Control Box is plugged into mains power Check that motor is engaged for automatic operation. Check all wiring from motor and microswitches to the control board are sound. Gate reverses while closing or stops while opening Check obstruction overload sensitivity adjustment Check for obstructions. Disengage the drive unit to manual and check the gate is in good working order. If a P.E.
PARTS LIST WHEN ORDERING SPARE PARTS PLEASE QUOTE THE ORDER CODE NUMBER TO YOUR YOUR INSTALLER/DEALER 21
WARRANTY AND EXCLUSION OF LIABILITY 1. This warranty is an addition to any non-excludable conditions or warranties that are implied into this contract by relevant statute, including the Trade Practices Act 1974 (Cth). 2.
NOTES Purchased From ___________________________________ Phone ______________________ Installed By _______________________________________ Date _______________________ Serial No.
AUTOMATIC TECHNOLOGY AUSTRALIA PTY LTD ABN 11 007 125 368 17-19 Advantage Rd, Highett, Victoria, Australia 3190 Tel: +61 3 9532 2788 Fax: +61 3 9532 2799 Web: www.ata-aust.com.au Email: sales@ata-aust.com.au © May 2005 Automatic Technology Australia Pty Ltd. All rights reserved. SecuraCode® is a registered trademark of Automatic Technology Australia Pty Ltd. In an ongoing commitment to product quality ATA reserve the right to change specification without notice. E&OE. Printed For Export.