AUTOMATIC TECHNOLOGY AUSTRALIA PTY LTD Elite SWING GATE OPENER OWNERS COPY Installation Instructions And Owners Manual Remote control Warning: Failure to comply with the Installation instructions and the Safety Warnings may result in Serious Personal Injury and/or Property Damage.
Contents Page Contents Page IMPORTANT SAFETY WARNINGS 3 CONTROL BOARD LAYOUT 13 PRODUCT DESCRIPTION 4 CONTROLLERS MODE SELECTION SWITCHES 14 GENERAL DESCRIPTION & FEATURES 5 CONTROL BOARD ADJUSTMENTS 15 INSTALLATION OF MECHANICAL DRIVE UNIT 6 CODING OF RECEIVER / TRANSMITTER 16 INSTALLATION OUTWARD SWING GATES 8 WIRING TERMINALS AND CONNECTORS 17 INSTALLATION OF MINIMUM SIDE ROOM KIT 8 INSTALLATION OF BATTERY BACK-UP 18 OPERATING INSTRUCTIONS FOR OWNER 18 FAULTS & REMEDIES / SP
PRODUCT DESCRIPTION The ATA Elite Swing Gate Opener consists of one electronic control box, two hand held transmitters and gate operator drive unit (one drive unit for single gate installation and two drive units for dual gate installations), with the accessories listed below. CONTROL BOX The control box contains the Control Board, (capable of driving 1 or 2 swing gates), a remote control receiver and transformer. When used with suitable glands, it is designed to meet the IP56 weather proof rating.
G E N E R A L D E S C R I P T I O N A N D F E AT U R E S The ATA Control board is packed with many new and exciting features using the latest technology in electronics, board design, and surface mounting components. The CB-9 control board is designed to automate one or two 24V DC swing or sliding gate drive units with or without limit switches. The CB-9 3.03 supersedes earlier CB-9 versions. A list of some of the features of the control board follows.
I N S TA L L AT I O N O F M E C H A N I C A L D R I V E U N I T The ATA ELITE SWING GATE OPENER is designed to operate most domestic swing gates. The gates must be in good working condition and should operate by hand relatively freely. Wind loading may affect the operation of the opener in high wind areas, correct obstruction and reversing settings should be chosen for trouble free operations. INITIAL CHECKING STEP 1 Before commencing installation of the Elite Swing Gate Opener, check the following: 1.
I N S TA L L AT I O N O F M E C H A N I C A L D R I V E U N I T MOUNTING OF DRIVE UNIT STEP 2 CHANGING TO/FROM MANUAL OPERATION 1. Mount Drive Unit using four (4) 10mm loxins or dynabolts. 2. Make sure that the Drive Unit is mounted at an appropriate distance from the ground (Minimum 35mm to allow clearance for drive arm extension). (Fig 1) NOTE: If the gateway slopes away from pier/post make sure an allowance is made for clearance of the Drive Arm Extension and Slave Arm to not touch the ground. FIG.
I N S TA L L AT I O N O F M E C H A N I C A L D R I V E U N I T FIG. 5 I N S TA L L AT I O N O F M I N I M U M S I D E R O O M K I T If you have limited Side Room, a special kit allows you to modify the Elite Swing Gate Opener so that the space required is reduced to the width of the Drive Unit (135mm). (ATA Order code 90182). NOTE: If a shorter Arm is required, drill the Drive Arm Exten- FITTING MINIMUM SIDE ROOM KIT STEP 3A 1.
I N S TA L L AT I O N O F E L E C T R O N I C C O N T R O L B O X MOUNTING CONTROL BOX STEP 4 The Control Box is to be mounted nearby the Drive Unit using (4) 6mm screws. The mounting coordinates is 55mm x 275mm. When locating the Control Box allow ample space around the unit for easy access and wiring connections. Remove cover from control box. Determine which leaf you would like to open first and close last. This gate leaf must be connected to Motor 1 (M1) terminals on the control board.
I N S TA L L AT I O N O F E L E C T R O N I C C O N T R O L B O X OPENS FIRST DUAL INSTALLATION Left Gate Opens First A B COM M1 OP CL COM OP M2 CL A MOTOR 2 M2 B MOTOR 1 M1 5 4 3 CB-9 CONTROL BOARD 2 1 5 (MOTOR 2) 4 3 2 1 (MOTOR 1) BLUE BLACK WHITE RED ORANGE WHITE RED ORANGE BLACK BLUE OPENS FIRST DUAL INSTALLATION Right Gate Opens First (MOTOR 2) CB-9 CONTROL BOARD A B COM M1 OP CL COM OP M2 CL A MOTOR 2 M2 B MOTOR 1 M1 BLACK BLUE WHITE RED ORANGE WHITE RED ORANGE BLUE BLACK Pag
CONT.. INSTALLATION OF ELECTRONIC CONTROL BOX CLOSE SINGLE INSTALLATION Left Gate Opens (MOTOR 1) OPEN M1 A B COM OP CL 5 3 4 1 MOTOR 1 M1 2 CB-9 CONTROL BOARD BLUE BLACK WHITE RED ORANGE CLOSE SINGLE INSTALLATION Right Gate Opens (MOTOR 1) OPEN MOTOR 1 M1 M1 A B COM OP CL BLACK BLUE WHITE RED ORANGE Page.
SETTING OPENING & CLOSING OBSTRUCTION FORCE STEP 6 SETTING OVERLOAD SENSITIVITY Engage the motor assembly (Fig 3 & 4), switch power on at power point. Slide back Drive Unit cover and lock it by key. 1.The overload sensitivity is adjustable using the OVERLOAD dial [25], with dial position 0 making it easy to overload a motor, increasing through positions 1 to 8, with position 9 being the hardest to overload a motor. 2.
C O N T R O L B O A R D L AY O U T Fig. 11 20 1 2 3 4 5 6 7 8 9 10 18 11 12 17 13 16 15 14 1. COMMON TERMINAL FOR (2) TO (7) BELOW. 2. PHOTO-ELECTRIC SAFETY BEAM INPUT. 3. OPEN CONTROL INPUT. 4. STOP CONTROL INPUT. 5. CLOSE CONTROL INPUT. 6. OPEN/STOP/CLOSE CONTROL INPUT. 7. PEDESTRIAN ACCESS CONTROL INPUT. 8. MOTOR 1 TERMINALS. 9. MOTOR 1 LIMIT SWITCH INPUTS. 10. MOTOR 2 LIMIT SWITCH INPUTS. 11. MOTOR 2 TERMINALS. 12. TERMINALS FOR 24V DC SUPPLY OUTPUT (TO ACCESSORIES). 13.
CONTROLLERS MODE SELECTION SWITCHES This section describes the operating modes which can be selected by the user using the control board's mode selection switches [23] Fig 11. SYNCHRONISED OVERLAPPING GATE LEAFES. 1. When dual swing gates are used it is common for a back stop to be mounted on one of the gate leaves so that the gate leaves are aligned when closed.
CONTROLLERS MODE SELECTION SWITCHES If the P.E. input is configured to stop the gate during opening or closing, then the gate can auto-close from a midway position. This feature is implemented so that once a vehicle has entered the gateway and broken the P.E. beam, the gate will stop. When the P.E. beam is cleared the gate will auto-close from the stopped position. This results in the gate not having to fully open and thus reducing the time unwarranted access through the gate is possible.
CODING OF RECEIVER/ TRANSMITTER DELETING TRANSMITTER CODES SETTING TRANSMITTERS CODES TO RECEIVER The Remote Transmitters can be programmed into the gates receiver to do two functions. Firstly the full Open/Stop/Close, and secondly the partly open gate for PEDestrian only access. The memory in the receiver can store up to 111 different remote control transmitters. • Make sure to connect the battery to the Transmitters. STORING THE TRANSMITTERS CODE FOR O/S/C 1.
WIRING TERMINALS & CONNECTORS CONTROL AND SAFETY INPUT TERMINALS. Figure 14 shows how to wire the control and safety input terminals to switches, such as a Photo Electric Beam. Note that the P.E., OPN and STP inputs require a normally closed contact, which is provided by the shunts (see Fig 11 and Fig 14). The appropriate shunt must be removed when the P E, OPN or STP inputs are used. The CLS, OSC and PED inputs require a normally open contact.
I N S TA L L AT I O N O F B AT T E RY B A C K - U P A battery backup system is provided so that the gate can be controlled (for a limited time) in the event of mains power failure. When the backup system is utilised, the control board detects the presence of mains voltage from the domestic power grid. When the mains power fails the control board switches to the backup supply provided by a 24V DC battery. When mains power is reinstated the control boards switches back to mains supply.
FA U LT S A N D R E M E D I E S Gate does not open and/or close Check that Control Box is plugged into mains power. Check that motor is engaged for automatic operation. Check all wiring from motor and microswitches to the control board are sound. Gate re-opens when closing or stops when opening Check obstruction overload sensitivity adjustment (See Page 12, step 7) Check for obstructions. Disengage the drive unit to manual (see page 7) and check the gate is in good working order (see page 6 step 1.1 & 1.
S PA R E PA RT S L I S T
* * WA R R A N T Y A N D E X C L U S I O N O F L I A B I L I T Y * * Subject to all of the matter set out below, Automatic Technology Australia Pty Ltd (“ATA”) WARRANTS for twelve months from the date of purchase (specified in the receipt sales docket) that the Elite Swing Gate Opener contained in the accompanying (the “Product”) is free of any defects in material and workmanship rendering it unmerchantable.