DCU 2010 INSTALLLATION MANUAL Version 1.
ElmoTech Ltd Version 1.0 Prepared by: Elmo-Tech Ltd. Corporate Headquarters 2 Ha-Barzel St. P.O. Box 13236 Ramat Ha-Chayal 61132 Tel Aviv Israel Tel: 03 – 6478871 Fax: 03 – 6478872 Visit us at: www.elmotech.com © 2002, Elmo Tech Ltd. All rights reserved.
Version 1.
ElmoTech Ltd Version 1.0 TABLE OF CONTENTS Section Page THE MONITOR CENTER/ PROBATION AGENCY ..................7 EQUIPMENT .......................................................................................8 THE OFFENDER’S PREMISES......................................................9 MONITORING SYSTEM LOCATION ......................................................9 INSTALLING THE DCU UNIT ............................................................10 Downloading the Curfew Schedule ...............
Version 1.0 ElmoTech Ltd TRANSMITTER CLEANING INSTRUCTIONS ........................31 CLEANING THE TRANSMITTER:........................................................31 TRANSMITTER STRAP REPLACEMENT ................................33 REASONS FOR STRAP REPLACEMENT ...............................................33 EQUIPMENT NEEDED FOR STRAP REPLACEMENT .............................34 REPLACING THE TRANSMITTER STRAPS...........................................34 FCC NOTICES ..................................
ElmoTech Ltd Version 1.0 LIST OF FIGURES Figure Page FIGURE 1 IDEAL DCU LOCATION ..........................................................9 FIGURE 2 DIAGRAMMATIC VIEW OF A DCU........................................11 FIGURE 3 CALIBRATING THE TRANSMITTER ........................................15 FIGURE 4 ATTACHING THE TRANSMITTER ...........................................17 FIGURE 5 PROTRUDING SIDE OF TRANSMITTER DIRECTED UPWARDS ...17 FIGURE 6 MALE\FEMALE CLIPS ATTACHED .............................
Version 1.
ElmoTech Ltd Version 1.0 THE MONITOR CENTER/ PROBATION AGENCY At the Monitor Center/Probation Agency: 1. Enter the Offender’s data in the monitoring application. This can be done well in advance, even before the actual equipment is allocated and installed. 2. Enter the following equipment data in the monitoring application. • DCU Serial No. - Check that the number entered matches the number on the DCU unit. • Transmitter Serial No.
Version 1.0 ElmoTech Ltd Equipment Check that you have all the required equipment: • DCU unit and power adapter • Transmitter • Electronic key • Locking device • Strap holder • Strap clips (male and female) • Screwdriver (to open a clip if necessary). It is recommended to use a 5 mm flat head screwdriver. It is always advisable to bring an extra set of strap clips to cater for the event in which the first set may be accidentally damaged during the installation.
ElmoTech Ltd Version 1.0 THE OFFENDER’S PREMISES Monitoring System Location In order to install the Monitoring System, you will need to find the best location for the DCU unit. The ideal place for the DCU unit is in the center of the house, 3 feet off the ground and at least 1 foot away from the wall.
Version 1.0 ElmoTech Ltd The DCU unit should be in an open area away from other electrical appliances (e.g. personal computers, laptops) or any metal objects. Installing the DCU Unit In order to install the DCU unit: 10 1. Plug the appropriate end of the power adapter cord into the 12VDC socket at the back of the DCU unit. 2. Plug the power adapter into a wall power socket.
ElmoTech Ltd Version 1.0 Figure 2 Diagrammatic View of a DCU If, at the end of the start-up self test, audible beeping sounds are heard and all three LED’s flash for 10 seconds, it indicates one of the following possible failures: i Case open micro-switch malfunction. i Tilt sensor malfunction. i Range threshold values lost (maximum reception range is used in this case).
Version 1.0 ElmoTech Ltd Downloading the Curfew Schedule Downloading Curfew Schedule data requires that the CMS (Central Monitoring System) telephones the Offender’s premises and transmits a series of signals to the DCU unit to allow it to monitor the Offender. After the DCU unit has been installed, perform the following: 12 1. Verify that the DCU units right LED is not flashing (i.e. the line is not busy). 2.
ElmoTech Ltd 4. Version 1.0 The Monitor Center personnel call back (optional) to confirm a successful download or to inform that the download failed and has to be performed again.
Version 1.0 ElmoTech Ltd Installing the Transmitter The officer should bring the following equipment for a Transmitter installation: • Transmitter • Male and female strap Clips • Electronic key • Strap holder • Locking tool • Flat-head screwdriver Calibrating the Transmitter Before any installation, the Transmitter has to be turned-on and calibrated. After the DCU unit is connected and in monitoring mode, do the following: 14 1.
ElmoTech Ltd Version 1.0 Figure 3 Calibrating the Transmitter 4. Press the Electronic Key down over one pair of metal pins (it does not matter which) with the two touch points on the Electronic Key matching the pair of metal pins on the Transmitter strap. Hold the Electronic key in this position while you do the next step. 5. Press the red button on the Electronic Key down for one second; the red light turns steadily on for two (2) seconds. 6.
Version 1.0 7. ElmoTech Ltd Place the Transmitter on its side on a non-metal table and wait 30 to 60 seconds, until audible beeping sounds are heard from the DCU unit. These beeps indicate that the Transmitter has successfully completed its Calibration process and is ready to be mounted on the offender. If a number of Transmitters calibrated at the same time, it is important to wait for the final beeps to be sure that the calibration went OK.
ElmoTech Ltd Version 1.0 Female clip Silver line Figure 4 Attaching the Transmitter 3. Wrap the Transmitter around the offender’s ankle at its narrowest point. Ensure that the protruding side of the Transmitter is directed upwards.
Version 1.0 ElmoTech Ltd It is important that the Transmitter fits tight around the offender’s ankle, but isn’t squeezing. Since it is permissible to wear a sock underneath the Transmitter, try to mount the Transmitter over the sock before it is fastened. 4. Cover the female Clip with the male Clip ensuring that the four pins on the male Clip fit correctly into the female Clip (the markings on the side of each clip have to match). Male & Female clips attached Figure 6 Male\Female Clips Attached 5.
ElmoTech Ltd Version 1.0 The Offender may wear a thin sock underneath and a thick sock over the Transmitter. DCU Range Setting DCU Range Setting is designed in order to create a limited free movement area. This ensures that Offender stays as close as possible to his\her premises and the immediate surrounding area. Four range settings are available: Short, Medium, Long and Maximum. To change the DCU range, a central computer command is required.
Version 1.0 ElmoTech Ltd sequence accompanied by 3 audible beeping sounds. This means that range test has started. The DCU unit will be in the range test mode for approximately 15 minutes, unless the Monitor Center/Agency terminates it manually. You can now escort the Offender around his/her premises in order to check that the range is sufficient, and to check for dead spots. 3. Escort the offender to the following locations in his/her premises: • Locations that are the most distant from the DCU unit.
ElmoTech Ltd 5. Version 1.0 Wait for up to two minutes in each checked location. During these two minutes four transmissions should be received from the PID. If four transmissions are received before two minutes have elapsed, you can move with the Offender to the next location to be checked. If less than four transmissions are received, phone the Monitor Center/ Agency and ask to change the range setting to a longer range.
Version 1.
ElmoTech Ltd Version 1.0 DAILY OPERATING INSTRUCTIONS In general, the installed DCU is transparent to the user of the telephone. All incoming calls trigger a pre—defined number of rings (system default is set at 6 rings) through out the house before the DCU picks up the call. Incoming Calls The central computer may, from time to time, initiate a call to the DCU. Therefore, the Offender may receive two types of phone calls; regular calls from other people, and occasional calls from the central computer.
Version 1.0 ElmoTech Ltd Note that it is imperative that the Offender gives up the line when the DCU needs to call. Failure to do so will be detected and could result in a violation situation. Outgoing Calls The DCU calls the Monitor Center, either to report a violation or to report its current status. Performing an outgoing call If the Offender tries to perform an outgoing call and hears a sharp modem sound, the Offender must hang up the phone immediately.
ElmoTech Ltd Version 1.0 General Rules for the Offender The following points describe the general rules for the Offender and also which appliances are prohibited in his\her premises.
Version 1.
ElmoTech Ltd Version 1.0 REMOVING THE MONITORING SYSTEM Sometimes it is required to remove the monitoring system before the defined confinement period is completed. Before disconnecting and removing the DCU unit, an end of service procedure should be performed. Initiating an End of Service Phone the Monitor Center/Agency personnel and ask them initiate the DCU end of service command.
Version 1.0 ElmoTech Ltd Removing the Transmitter It is recommended that only an Officer remove the Transmitter. To remove the Transmitter perform the following steps: 1. Check to see if the Clip has been tampered with. Be aware of the following signs: iCracks on the clips iBroken pins. iSign of adhesive or glue. 2. Use a screwdriver to break the disposable Clips. Screwdriver Grooves Be careful not to damage or cut the strap. 3. 28 Collect all the fragments of the Clip.
ElmoTech Ltd Version 1.0 Disconnecting the Transmitter In order to disconnect (turn off) the Transmitter, perform the following: 1. Hold the transmitter in your hand with the 4 metal pins (2 pairs, along the strap) pointing forward. 2. Hold the Electronic Key in your other hand, with the black button pointing toward the open or free end of the strap. 3.
Version 1.0 5. ElmoTech Ltd If the transmitter successfully receives the shut down command, the red light, on the Electronic Key, will flash for two (2) seconds. If the transmitter failed to receive the shut down command, the red light will turn off after the initial two (2) seconds on. If the Electronic Key battery is low the red light will immediately flash for two (2) seconds, once the red button is pressed. (No command is sent to the Transmitter).
ElmoTech Ltd Version 1.0 TRANSMITTER CLEANING INSTRUCTIONS The Transmitter is made of a single mold, especially designed to protect the integrity of the electronic circuits during daily use and while it is being cleaned. A soft brush and an Alcohol based solution; soapy water or Lysol can be used to clean the Transmitter. For additional safety and user comfort it is recommended that after cleaning with any of the above, you wash and wipe the Transmitter with clear water before it is re-used.
Version 1.
ElmoTech Ltd Version 1.0 TRANSMITTER STRAP REPLACEMENT After some time and depending on the wear and tear of the Transmitter, the Transmitter straps need to be replaced. Reasons for Strap Replacement The following points indicate possible reasons for replacing a Transmitter strap: • Visible damage to one or both straps • Unexplainable strap tamper alarms • Transmitter will not calibrate When testing the straps before changing them, make sure the clip is properly locked.
Version 1.0 ElmoTech Ltd Equipment Needed for Strap Replacement The following list indicates equipment the Officer will need to complete a strap replacement: • 1 Transmitter “body” • 1 pair of replacement straps (long/medium non-pins side and long/medium pins side) • Screw driver • Extra screws • Extra strap clasps (male and • Electronic Key Replacing the Transmitter Straps Following are detailed instructions for replacing the Transmitter straps: 34 1.
ElmoTech Ltd Version 1.0 5. Put the strap clasp back in place (the wider side pointing in-wards). 6. Close the screw with the screwdriver. It has to be closed firmly, but not too tight since this can damage the strap (maximum allowed torque is 1 Newton x Meter). 7. Test the new strap by performing a calibration (see the section, Calibrating the Transmitter). If, after the calibration, the Transmitter does not reset, repeat steps 1-3 and make sure that the strap is positioned correctly over the pins.
Version 1.0 ElmoTech Ltd FCC NOTICES DCU FCC Notices The DCU Model 500 has been tested and found to comply with the limits of a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device generates, uses, and can radiate radio frequency energy and, if installed and used in accordance with the instruction, may cause harmful interference to radio communications.
ElmoTech Ltd DCU & Transmitter Field Installation Manual Version 1.
Version 1.0 ElmoTech Ltd DCU Customer Information The DCU complies with the FCC part 68 Rules. On the side panel (bottom) of this equipment is a label that contains, among other information, the FCC Registration Number and Ringer Equivalence Number (REN is 1.0 B). An FCC compliant telephone cord is and connector (8949j62/2*6”102) is provided with this equipment.
ElmoTech Ltd Version 1.0 Transmitter FCC Notices The TXMTR Model 500 complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. This device has been tested and found to comply with the limits of the Class B digital device, pursuant to Part 15 of the FCC rules.