Version Information Version Release Date Notes 1 04/18 Initial release 2 11/18 Firmware version 1.0.
Welcome to Atlona! Thank you for purchasing this Atlona product. We hope you enjoy it and will take an extra few moments to register your new purchase. Registration only takes a few minutes and protects this product against theft or loss. In addition, you will receive notifications of product updates and firmware. Atlona product registration is voluntary and failure to register will not affect the product warranty. To register your product, go to http://www.atlona.
Atlona, Inc. (“Atlona”) Limited Product Warranty Coverage Atlona warrants its products will substantially perform to their published specifications and will be free from defects in materials and workmanship under normal use, conditions and service.
Atlona, Inc. (“Atlona”) Limited Product Warranty • Damage, deterioration or malfunction resulting from the installation or removal of this product from any installation, any unauthorized tampering with this product, any repairs attempted by anyone unauthorized by Atlona to make such repairs, or any other cause which does not relate directly to a defect in materials and/or workmanship of this product.
Important Safety Information The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. Das Symbol des Blitzzeichens innerhalb eines gleichseitigen Dreiecks soll den Benutzer davor warnen, dass innerhalb des Gehäuses gefährlich hohe Spannung an berührbaren Teilen anliegt.
Important Safety Information CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCT THE RISK OF ELECTRIC SHOCK DO NOT OPEN ENCLOSURE OR EXPOSE TO RAIN OR MOISTURE. NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance instructions in the literature accompanying the product.
Table of Contents Introduction 9 Features 9 Package Contents 9 Panel Description 10 Installation Audio Connectors AUDIO IN 4 / 8 Ω OUT 24 / 70 / 100V RS-232 Connection Instructions Connection Diagrams IP Configuration Using the Rear Panel Using Commands Using the Web GUI 11 11 11 11 11 12 13 14 15 15 16 17 Basic Operation LED Indicators Locking the Front Panel Power Modes Powering On or Off Auto Power On mode Auto Power Down mode Factory Reset 19 19 20 21 21 22 22 23 The Web GUI Introduction to
Introduction The Atlona Gain™ 60 (AT-GAIN-60) is a compact power amplifier designed for low or high-impedance applications. A mode selector switch allows the Gain 60 to deliver two channels of 30 watts each into 4 or 8 ohms, or a single channel of 60 watts at 24, 70, or 100 volts. This Class-D amplifier is energy efficient and ENERGY STAR qualified, and is also convection-cooled without the need for fans.
Panel Description 1 2 4 6 7 Front 8 9 11 13 15 16 Rear L TX RX R -14 CLASS 2 WIRING 24 / 70 / 100V OUT -4 L -9 R -2 -19 -20 -22 dB TX RX L R 3 -14 1 5 CLASS 2 WIRING 24 / 70 / 100V OUT -4 L -9 -2 AUDIO IN 2 INPUT GAIN 10 12 CLASS 2 WIRING 14 DC28V 3.4A 17 R PWR CLASS 2 WIRING This LED indicator solid AUDIOglows IN 2 DC28V unit 3.4A INPUT GAINgreen when the is powered. When set to standby mode, this LED indicator glows solid amber.
Installation Audio Connectors The AT-GAIN-60 provides two audio ports: one input and one output. The AUDIO IN 1 port can be used to connect an audio digital signal processor (DSP) or other audio source device. Balanced or unbalanced wiring is supported. The AUDIO IN 2 port is used to connect an analog audio source using RCA-type cables. 1. Use wire strippers to remove a portion of the cable jacket. 2. Remove at least 3/16” (5 mm) from the insulation of each wire. 3.
Installation RS-232 The AT-GAIN-60 provides RS-232 control between an automation system and an RS-232 device. This step is optional. 1. Use wire strippers to remove a portion of the cable jacket. 2. Remove at least 3/16” (5 mm) from the insulation of the RX, TX, and GND wires. 3. Insert the TX, RX, and GND wires into correct terminal on the included captive screw block.
Installation Connection Instructions 1. Connect an analog audio source to the AUDIO IN ports. Once connected, press the INPUT button on the front panel, to switch between the RCA and the 5-pin captive screw port. • RCA cables (unbalanced) Connect shielded RCA-type cables from the audio source to the AUDIO IN 2 left/right RCA jacks. • Balanced/Unbalanced Connect the included 5-pin captive screw to the AUDIO IN 1 port. Use the desired wiring configuration, on the previous page. 2.
Installation Connection Diagrams Program / Stereo Speakers Application Program Speakers ric ne MS GeER SYSTE SPEAK Laptop ric ne MS GeER SYSTE Tablet (BYOD) SPEAK Vi o de di Au Au di o o di Au o LAY DISP 2 1 DC AT-VGW-250 19V NET ETHER T INPU -C USB OUT DP I3 HDM I4 HDM D BYO HDMI W-250 MDP OUT Et he rn e t AT-VG he Et AT-GAIN-60 Vid eo W 510 ne W- D-S -UH t AT Et h er ne t AT-UHD-SW-510W Et h er ne t/ Po E LAN AT-VTP-800-WH UHD/HD Display Distrib
Installation IP Configuration The AT-GAIN-60 is shipped with DHCP enabled. Once connected to a network, the DHCP server (if available), will automatically assign an IP address to the unit. Execute the arp -a command at the Windows command line or use an IP scanner to locate the AT-GAIN-60 on the network. If the AT-GAIN-60 is unable to detect a DHCP server, within 15 seconds, then the unit will be assigned the following IP configuration: • • • IP address Subnet mask Gateway 192.168.1.254 255.255.0.
Installation Using Commands Use the IPStatic and IPDHCP commands to switch between DHCP and static IP mode using Telnet or RS-232. Refer to the Application Programmers Interface documentation for more information. All commands and their arguments are case-sensitive. • Setting static IP mode 1. Connect to the AT-GAIN-60 using Telnet. 2. At the command line, execute the IPDHCP command using the off argument, as shown. IPDHCP off 3. Execute the IPStatic command.
Installation Using the Web GUI The Network page (page 28) in the web GUI allows the option for the AT-GAIN-60 to use either DHCP or static IP mode. In order to access the web GUI, the IP address of the AT-GAIN-60 must be known. 1. Open the desired web browser and enter the IP address of the AT-GAIN-60. 2. Log in, using the required credentials. The factory-default username and password are listed below: Username: admin Password: Atlona 3. Click the Network tab, located on the side menu bar.
Installation 5. The following message box will be displayed: 6. Click OK to accept the changes or click Cancel to abort changes and return to the Network page.
Basic Operation LED Indicators The LED indicators on the front panel, provide information on the current state of the AT-GAIN-60. Refer to the table below for more information. LED Indicator State PWR Solid green TX RX L R Description Unit is powered. Solid amber -14 CLASS 2 WIRING 24 / 70 / 100V OUT -4 L -9 -2 -19 R Unit is in low power consumption mode. -20 -22 Flashing green Off 1 2 MUTE Audio Output Indicators dB AUDIO IN 2 2 WIRING UnitCLASS is in blink mode. DC28V 3.
Basic Operation Locking the Front Panel The buttons on the front panel can be locked or unlocked. Locking the front-panel buttons prevents accidental pressing of the buttons, which may occur when the unit is mounted in a rack environment. Locking and unlocking of the front-panel buttons is managed through the web GUI or by executing the Lock and Unlock API commands. Refer to the API documentation for more information. 1. Login to the web GUI.
Basic Operation Power Modes The following section discusses the power mode features which have been integrated into the AT-GAIN-60. Power modes are located under the Control tab within the web GUI. 1. Open the desired web browser and enter the IP address of the AT-GAIN-60. 2. Log in, using the required credentials. The factory-default username and password are listed below: Username: admin Password: Atlona 3. Click the Control tab, located on the side menu bar.
Basic Operation Auto Power On mode When enabled, Auto Power On mode will automatically power-on the AT-GAIN-60 when an input signal is detected on either the AUDIO IN 1 or AUDIO IN 2 port. When the AT-GAIN-60 is powered-on from a low-power state, the PWR, INPUT, and VOL LED indicators will be illuminated. By default this feature is enabled. 1. Click the ON option, if not already selected, to enable Auto Power On mode. 2. Click OFF to disable this feature.
Basic Operation Factory Reset If necessary, the AT-GAIN-60 can be reset to factory-default settings. Note that the AT-GAIN-60 will be placed in DHCP mode, as part of the reset procedure. The AT-GAIN-60 can also be reset through the web GUI. Refer to the Control page (page 30) for more information. 1. Press and hold the RESET button on the back panel, using the end of a paper clip or other pointed object, for approximately 10 seconds.
The Web GUI Introduction to the Web GUI The AT-GAIN-60 includes a built-in web GUI. Atlona recommends that the web GUI be used to set up the AT-GAIN-60, as it provides intuitive management of all features. The AT-GAIN-60 is shipped with DHCP enabled. Once connected to a network, the DHCP server will automatically assign an IP address to the unit. Use an IP scanner to determine the IP address of the AT-GAIN-60. If a static IP address is desired, refer to IP Configuration (page 15).
The Web GUI 7. The Status page will be displayed. 8. To logout of the web GUI at any time, click Logout on the side menu bar. Once logged out, the AT-GAIN-60 will display the login screen. Menu Bar The window on the left side of the screen is the menu bar. The menu system is divided into three sections: Home, Settings, and Configuration. When the mouse is moved over each menu item, it will be highlighted in black. Click the menu item to go that page.
The Web GUI Status page Download Log Click this button to download a log of command events to the computer’s hard disk. Model The SKU of this product. Firmware The current firmware version installed. MAC Address The MAC address of the AT-GAIN-60. Serial Number The serial number of the AT-GAIN-60. Operating Time The time in which the unit has been in the “on” state since it was last rebooted. Save Click this button to save the system settings to a local file. System settings files are saved in .
The Web GUI Firmware page Current Firmware The current firmware version installed. Status (progress bar) Displays the status of loading new firmware during a firmware update procedure. Browse Click this button to select the firmware file. Click the Load button to begin the update procedure. Refer to Updating the Firmware (page 34) for more information. Load Click this button to upload the selected firmware file to the AT-GAIN-60.
The Web GUI Network page After pressing the Save button, a reboot message will appear at the top of the web GUI. The AT-GAIN-60 must be rebooted when any of the network settings have changed. DHCP Click the ON button to enable DHCP. Click the OFF button to enable static IP mode. In static IP mode, the IP Address, Subnet, and Gateway fields can be modified. IP Address Enter the IP address of the AT-GAIN-60 in this field. This field can only be changed when DHCP is set to OFF.
The Web GUI Telnet Login Mode Click the ON button to prompt for username and password credentials. Username and password credentials are the same as the web GUI login credentials. Click the OFF button to create an open Telnet session that does not require login credentials. The default setting is OFF. Save / Cancel Click the Save button after any changes have been made. Click the Cancel button to abort changes.
The Web GUI Control page Power Click the ON button to power-on the AT-GAIN-60. Click the OFF button to power-off the unit. Auto Power On Settings this feature to ON will automatically power-on the AT-GAIN-60 when an incoming audio signal is detected. The default setting is ON. Refer to Auto Power On mode (page 22) for more information. Auto Power Down Enables or disables auto power down mode. Refer to Auto Power Down mode (page 22) for more information.
The Web GUI RS-232 Sets the RS-232 settings used by the control device. The default settings are 115200, 8, None, 1. Setting Description Baud rate Sets the baud rate. The following options are available: 110, 300, 600, 1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200. Data bit Sets the number of data bits used to represent each character of data. The following options are available: 5, 6, 7, or 8.
The Web GUI Users page Current Username The administrator username. This field cannot be changed. Password Enter the password for the administrator in this field. Special characters (e.g. #, %, @, &, etc.) are not permitted. Change Admin Password • Old password Enter the current password in this field. The default password is Atlona. • New Password Enter the new password in this field. • Confirm Password Verify the new password by entering it in this field.
The Web GUI Audio page Input Selection Click this drop-down list to select the audio input: Balance or Unbalance. Select the Balance option to set the active audio input to the AUDIO IN 1 port. Select the Unbalance option to set the AUDIO IN 2 port the active audio input. Equalization Click and drag the Bass and Treble sliders to the desired settings. The Bass and Treble sliders have a range from -10 to +10. Click and drag the Volume slider to adjust the output volume to the desired level.
Appendix Updating the Firmware The AT-GAIN-60 can only be updated through the web GUI. IMPORTANT: As of this writing, Google Chrome is the only browser that is supported for firmware updates. Other browsers will be supported in future versions of firmware. Required items: • • • • Firmware IP address of the AT-GAIN-60 Computer on the same network as the AT-GAIN-60 Username and password to access the web GUI 1. Verify that an Ethernet cable is connected between the AT-GAIN-60 and the network.
Appendix 4. Click Status in the menu bar on left side of the screen. 5. Click the Save button. 6. The Save As dialog box will be displayed. Select the folder where the file will be saved. Click the Save button to save the file. The file is saved in .bin format and uses the default name of systemsettings.bin. 7. Click Firmware on the left side of the screen. 8. Click the Browse button to select the firmware file. 9. Click the Load button to begin the upgrade process.
Appendix Rack Mount Installation The AT-GAIN-60 can be mounted in different ways, based on the number of units that are being installed. In order to rack-mount the AT-GAIN-60, the AT-RACK-1RU will need to be purchased from atlona.com. The AT-RACK-1RU can be used to either mount three AT-GAIN-60 unit at once or it can be used to mount two ATGAIN units. IMPORTANT: Before mounting the AT-GAIN-60 to the AT-RACK-1RU, remove the rubber feet from the bottom of the unit.
Appendix 3. Mount each of the AT-GAIN-60 units in the rack. Match the mounting holes on the bottom of each AT-GAIN-60 with the holes in the rack tray, marked in the illustration below. TOP Front of rack tray 4. Install the rack tray in the rack shelf and secure the rack tray with two screws on either side. IMPORTANT: To prevent possible damage to the device, rack, and/or screws, do not overtighten or use high-torque devices when securing the devices to the rack.
Appendix Mounting two AT-GAIN-60 units The following provides an alternate method for mounting AT-GAIN-60 units closer together. This option provides extra space in the AT-RACK-1U for cabling, etc. 1. Turn the AT-GAIN-60 so that the bottom of the unit is facing upward. 2. Locate the two sets of holes on either side of the unit. Refer to Rack Mount Installation (page 36) for the location of the mounting holes. 3. Mount each of the AT-GAIN-60 units in the rack.
Appendix Default Settings The following table lists the factory-default settings for the AT-GAIN-60. Feature Settings Network DHCP Static IP address Subnet Gateway Telnet Port HTTP Port IP Timeout Hostname Telnet Login Mode ON 192.168.1.254 255.255.0.0 192.168.1.
Appendix Specifications Connectors, Controls, and Indicators LAN 1 - RJ45 AUDIO IN 1 1 - 5-pin captive screw, balanced: 10 kΩ AUDIO IN 2 2 - RCA-type, female, unbalanced: 20 kΩ 4 / 8 Ω OUT 1 - 4-pin, 5.08 mm lock-down screw connector 24 / 70 / 100V 1 - 5-pin, 3.5mm Power 1 - 3.
Appendix Audio Performance Frequency Response 20 Hz - 20 kHz, ±0.2 / - 2 dB @ 4 Ω load THD + N < 0.1% @ 1 kHz, 3 db below clipping SNR > 95 dBA WTD Damping Factor < 48 @ 8 Ω Amplifier Type Class D Temperature Fahrenheit Celsius Operating 32 °F to 122 °F 0 °C to 50 °C Storage -40 °F to 158 °F -40 °C to 70 °C Humidity (RH) 90% RH, non-condensing Power Standby Mode Powers down after 5 - 25 minutes (adjustable) of no signal; complies with ENERGY STAR power consumption limits of < 0.
Index A Appendix 31 Audio connectors 11 distributed speakers 11 impedance 11 Auto power-down. See Power modes C Configuration IP.
atlona.com • 408.962.0515 • 877.536.3976 © 2018 Atlona Inc. All rights reserved. “Atlona” and the Atlona logo are registered trademarks of Atlona Inc. All other brand names and trademarks or registered trademarks are the property of their respective owners. Pricing, specifications and availability subject to change without notice. Actual products, product images, and online product images may vary from images shown here.