AA35G & AA60G Owner’s Manual Commercial Mixer Amplifier AA35G & AA60G Commercial Mixer Amplifier 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 –1– Specifications are subject to change without notice. AtlasIED.
AA35G & AA60G Owner’s Manual Commercial Mixer Amplifier Table of Contents Important Safety Instructions .................................................................................................................. 3 Introduction ............................................................................................................................................ 5 Key Features .......................................................................................................................
AA35G & AA60G Owner’s Manual Commercial Mixer Amplifier Important Safety Instructions The lightning flash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage “ within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
AA35G & AA60G Owner’s Manual Commercial Mixer Amplifier WARNING - When The Device Is In Use • • • • • • • • • • • • • WARNING: For the terminals marked with symbol of may be of sufficient magnitude to constitute a risk of electric shock. The external wiring connected to the terminals requires installation by an instructed person or the used of ready-made leads or cords.
AA35G & AA60G Owner’s Manual Commercial Mixer Amplifier Introduction Congratulations and thank you for purchasing the AtlasIED AA35G/AA60G mixer amplifier. Small, compact, and engineered for reliability, the AtlasIED AA35G/AA60G will provide years of service and flexibility in background music and paging applications.
AA35G & AA60G Owner’s Manual Commercial Mixer Amplifier Front Panel 1 2 6 3 4 7 5 8 1. Input Signal Presence/Clip Indicators Green LED, one above each channel’s volume control, illuminates when input signal exceeds –40 dBu, and flashes brightly at threshold of audible distortion. 2. Master Level Control The Master Level control will raise or lower all the input channels together.
AA35G & AA60G Owner’s Manual Commercial Mixer Amplifier Rear Panel 3 1 5 2 4 6 7 8 9 1. AC Power Inlet Detachable IEC accepts US or Euro style power cords. 2. Amplifier Outputs For loudspeaker connections, connect as follows or proceed to the setup section for typical wiring schemes.
AA35G & AA60G Owner’s Manual Commercial Mixer Amplifier 5. Line Output Connector 3-Pin Balanced Euroblock connector. Line level output is Pre Master Level control. Use this output to connect signal to a secondary amplifier. 6. Zone 2 Level Control Potentiometer adjusts level for both Zone 2 outputs. 7. Zone 2 Output Terminals 4-terminal Euroblock connector (2 terminals for 1W output to 81 loudspeaker, 2 terminals for 6001 output to PBX MOH, music-on-hold, port or an additional amplifier). 8.
AA35G & AA60G Owner’s Manual Commercial Mixer Amplifier Choose Input Wire and Connectors AtlasIED recommends using balanced line (two-conductor plus shield), 22-24 gauge cables and connectors. Unbalanced line may also be used but may result in noise over long cable runs. The AA35G and AA60G have two types of input connectors: Euroblock and RCA. • Mic / Line Connector (CH1): 5-pin Euroblock, balanced, pins 3, 4 and 5 (Figure 2.3).
AA35G & AA60G Owner’s Manual Commercial Mixer Amplifier Choose Output Wire and Connectors Amplifier Output Connections: Slip the cable lugs under the output screw terminals and tighten (Figure 2.5). Slide the supplied non-touch cover over the output connections from top to bottom to cover them. AtlasIED recommends using high-quality, two-conductor, heavy gauge speaker wire and connectors. Crimp-on spade lugs may be used for the output connectors.
AA35G & AA60G Owner’s Manual Commercial Mixer Amplifier Wire the System Typical input and output wiring is shown in Figure 2.8. INPUTS: For Input 1, connect a microphone or balanced line-level signal to the Input 1 balanced input. Set the Mic/Line switch (DIP switch #1) accordingly. For the other inputs, connect unbalanced line-level signals to the RCA input connectors. OUTPUTS: Maintain proper polarity (+/–) on amplifier output connectors.
AA35G & AA60G Owner’s Manual Commercial Mixer Amplifier Operation Powering Up 1. Turn Off any equipment connected to the Preamp Output connector. 2. Plug the amplifier’s power cord into a 3-wire grounded AC outlet. 3. Turn down the input volume controls. 4. Turn down the master volume control. 5. Turn on the Power switch. The Power indicator should glow. 6. Turn the input volume controls in use about 3/4 up. 7. Turn up the master volume control(s) until the desired loudness or power level is achieved. 8.
AA35G & AA60G Owner’s Manual Commercial Mixer Amplifier Troubleshooting CONDITION: No power to the mixer amplifier. POSSIBLE REASON: • The mixer amplifier’s power switch is Off. • The mixer amplifier is not plugged into the AC power receptacle. • The mixer amplifier’s high-voltage power supply circuit breaker has tripped. Verify that the AC mains voltage is correct. CONDITION: Distorted sound. POSSIBLE REASON: • Input signal level is too high. Turn down the input level controls.
AA35G & AA60G Owner’s Manual Commercial Mixer Amplifier Specifications AA35G AA60G Power into 81 or 70V/100V Output (1kHz with 0.5% THD) 35W 60W Frequency Response (at 1 Watt from 81 Tap) 50Hz - 20kHz ±1 dB Electrical Specifications Technical Data Signal to Noise Ratio (Ref. to Rated Power, Master Volume at Minimum) Mic: > 58 dB Line: > 60 dB Telephone: > 60 dB Inputs 2 or 3 (and 4 in AA60G): > 78 dB THD + N < 0.5% at Rated Power at 1kHz < 0.
AA35G & AA60G Owner’s Manual Commercial Mixer Amplifier Notes: 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 – 15 – Specifications are subject to change without notice. AtlasIED.
AA35G & AA60G Owner’s Manual Commercial Mixer Amplifier Limited Warranty All products manufactured by AtlasIED are warranted to the original dealer/installer, industrial or commercial purchaser to be free from defects in material and workmanship and to be in compliance with our published specifications, if any.