Motherboard Z9PA-D8 系列
C7572 第一版 2012 年 8 月發行 版權說明 ©ASUSTeK Computer Inc. All rights reserved.
目錄內容 安全性須知................................................................................................................. viii 電氣方面的安全性...................................................................................... viii 操作方面的安全性...................................................................................... viii 關於這本用戶手冊.....................................................................................................ix 用戶手冊的編排方式..............................................................
目錄內容 2.5.3 指定中斷要求........................................................................... 2-17 2.5.4 PCI Express x16 插槽(x16 link)................................ 2-17 2.5.5 PCI Express x8 插槽(x8 link)..................................... 2-17 2.5.6 PCI Express x8 插槽(x4 link)..................................... 2-17 2.5.6 PIKE 插槽(僅 Z9PA-D8 支持).................................... 2-18 2.5.7 安裝華碩 PIKE RAID 卡...................................................... 2-19 2.5.8 安裝 ASMB6 管理卡................
目錄內容 4.3 主菜單(Main)..................................................................................... 4-10 4.3.1 System Date [Day xx/xx/xxxx]...................................... 4-10 4.3.2 System Time [xx:xx:xx]...................................................... 4-10 4.4 高級菜單(Advanced)...................................................................... 4-11 4.4.1 處理器設置(CPU Configuration)............................... 4-11 4.4.2 處理器電源管理設置 (CPU Power Management Configuration)............
目錄內容 第五章:RAID 磁盤陣列設置 5.1 RAID 功能設置.......................................................................................... 5-3 5.1.1 RAID 功能說明........................................................................... 5-3 5.1.2 安裝硬盤....................................................................................... 5-4 5.1.3 設置 BIOS 中的 RAID 選項................................................... 5-4 5.1.4 RAID 設置程序........................................................................... 5-4 5.
目錄內容 第六章:安裝驅動程序 6.1 安裝 RAID 驅動程序............................................................................... 6-3 6.1.1 創建一張 RAID 驅動程序軟盤.............................................. 6-3 6.1.2 安裝 RAID 控制器驅動程序.................................................. 6-6 6.2 安裝 Intel 芯片組軟件.......................................................................... 6-16 6.3 安裝 Intel® 網卡驅動程序.................................................................... 6-19 6.4 安裝顯卡驅動程序..............................
安全性須知 電氣方面的安全性 • 為避免可能的電擊造成嚴重損害,在搬動電腦主機之前,請先將電腦電 源線暫時從電源插槽中拔掉。 • 當您要加入硬件設備到系統中或者要去除系統中的硬件設備時,請務必 先連接該設備的數據線,然後再連接電源線。可能的話,在安裝硬件設 備之前先拔掉電腦電源的電源線。 • 當您要從主板連接或拔除任何的數據線之前,請確定所有的電源線已事 先拔掉。 • 在使用擴展卡或擴展卡之前,我們建議您可以先尋求專業人士的協助。 這些設備有可能會干擾接地的迴路。 • 請確定電源的電壓設置已調整到本國/本區域所使用的電壓標準值。若您 不確定您所屬區域的供應電壓值為何,那麼請就近詢問當地的電力公司 人員。 • 如果電源已損壞,請不要嘗試自行修復。請將之交給專業技術服務人員 或經銷商來處理。 操作方面的安全性 • 在您安裝主板以及加入硬件設備之前,請務必詳加閱讀本手冊所提供的 相關信息。 • 在使用產品之前,請確定所有的排線、電源線都已正確地連接好。若您 發現有任何重大的瑕疵,請儘速聯絡您的經銷商。 • 為避免發生電氣短路情形,請務必將所有沒用到的螺絲、回型針及其他 零件收好,不要遺留在主板上
關於這本用戶手冊 產品用戶手冊包含了所有當您在安裝華碩 Z9PA-D8 系列主板時所需用到 的信息。 用戶手冊的編排方式 用戶手冊是由下面幾個章節所組成: • 第一章:產品介紹 本章節描述本主板的功能和新技術。 • 第二章:硬件設備信息 本章節描述所有您在安裝系統元件時必須完成的硬件安裝程序。詳 細內容有:處理器與內存安裝、跳線選擇區設置以及主板的各種設備接 口。 • 第三章:開啟電源 本章節說明開啟電腦電源的順序以及電腦開機後所發出各種不同類型 嗶嗶聲的代表意義。 • 第四章:BIOS 程序設置 本章節描述如何使用 BIOS 設置程序中的每一個菜單項目來更改系統 的設置。此外也會詳加介紹 BIOS 各項設置值的使用時機與參數設置。 • 第五章: RAID 磁盤陣列設置 本章節提供本主板的 RAID 設 置信息。 • 第六章:安裝驅動程序 本章節介紹本主板驅動程序的安裝。 • 附錄:相關信息 本附錄中包含您在設置本主板時有可能會用到的信息。 ix
提示符號 為了能夠確保您正確地完成主板設置,請務必注意下面這些會在本手冊 中出現的標示符號所代表的特殊含意。 警告:提醒您在進行某一項工作時注意您本身的安全。 小心:提醒您在進行某一項工作時注意勿傷害到電腦主板元件。 重要: 此符號表示您必須要遵照手冊所描述之方式完成一項或多 項軟硬件的安裝或設置。 注意:提供有助於完成某項工作的訣竅和其他額外的信息。 跳線帽及圖標說明 主板上有一些小小的塑料套,裡面有金屬導線,可以套住選擇區的任二 隻針腳(Pin)使其相連而成一通路(短路),本手冊稱之為跳線帽。 有關主板的跳線帽使用設置,茲利用以下圖標說明。以下圖為例,欲設 置為“Jumper™ Mode”,需在選擇區的第一及第二隻針腳部份蓋上跳線 帽,本手冊圖標即以塗上底色代表蓋上跳線帽的位置,而空白的部份則代表 空接針。以文字表示為:[1-2]。 因此,欲設置為“JumperFree™ Mode”, 以右圖表示即為在“第二及第三隻針腳部份蓋 上跳線帽”,以文字表示即為:[2-3]。 1 2 Jumper Mode 2 3 Jumper Free (Default) 哪裡可以找到更多的產品信息 您可以通過下
30 電子信息產品污染控制標示:圖中之數字為產品之環保使用期 限。僅指電子信息產品中含有的有毒有害物質或元素不致發生 外洩或突變從而對環境造成污染或對人身、財產造成嚴重損害 的期限。 有毒有害物質或元素的名稱及含量說明標示: 有害物質或元素 部件名稱 鉛 (Pb) 汞 (Hg) 鎘 (Cd) 六價鉻 (Cr(VI)) 多溴聯苯 (PBB) 多溴二苯 醚(PBDE) 印刷電路板 及其電子 組件 x o o o o o 外部信號連 接頭及線材 x o o o o o 外殼 x o o o o o 軟驅 x o o o o o 電池 x o o o o o 光驅 x o o o o o 散熱設備 x o o o o o 電源適配器 x o o o o o 硬盤 x o o o o o 中央處理器 與內存 x o o o o o ○: 表 示 該 有 毒 有 害 物 質 在 該 部 件 所 有 均 質 材 料 中 的 含 量 均 在 S J / T 11363-2
Z9PA-D8 系列主板規格列表 型號 Z9PA-D8 處理器 2 x LGA 2011 socket Z9PA-D8C Intel® Xeon® 處理器 E5-2600 產品家族(高達 135W) Intel® QuickPath Interconnect (QPI) 6.4/7.2/8.0 GT/s 核心邏輯 Intel® C602-A 芯片組 主板尺寸 華碩特色 功能 內存 擴展插槽 12 x 10 英寸 風扇速度 控制 v Rack Ready (機架與塔 式雙用途) v Rack Optimized (機架專用) - ASWM Enterprise v 插槽總數 8(每顆 CPU 支持 4 通道,4 根內存條) 電壓 1.5V/1.
Z9PA-D8 系列主板規格列表 型號 Z9PA-D8 Z9PA-D8C SATA 控制器 Intel ® C602-A 芯片 組: 4 x SATA 3 Gb/s 2 x SATA 6 Gb/s Intel® Rapid Storage 技術(僅適用於 Windows) (支持軟件 RAID 0, 1, 10, & 5 設置) LSI® Mega RAID(僅 適用於 W i n d o w s/ Linux) (支持軟件 RAID 0, 1, & 10 設置) Intel ® C602-A 芯片 組: 4 x SATA 3 Gb/s 2 x SATA 6 Gb/s Intel® Rapid Storage 技術(僅適用於 Windows) (支持軟件 RAID 0, 1, 10, & 5 設置) SAS 控制器 選購: 華碩 PIKE 2008 8 端口 SAS 6G RAID 卡 華碩 P I K E 2008/ IMR 8 端口 SAS 6G RAID 卡 華碩 PIKE 2108 8 端口 SAS 6G H/W RAID 卡 華碩 PIKE 2208 8 端
Z9PA-D8 系列主板規格列表 型號 板載 I/O 接口 後側面板 I/O 接口 管理方案 監控 Z9PA-D8 1 電源接口 24-pin SSI 電源接口 + 8-pin SSI 12V 電 源接口(適用于 95W 或更低電壓 CPU) 24-pin SSI 電源接口 + 8-pin SSI 12V 電 源接口 + 8-pin SSI 12V 電源接口(支持 ATX 與 SSI 電源供應器)** 管理接口 板載插槽用於安裝 管理卡 USB 接口 1 x USB 接口(Type A USB 插槽) 2x USB 擴展套件數據線連接排針(最多 支持 4 個設備) 風扇電源插座 8 x 4-pin SMBus 1 機箱開啟警告 排針 1 前面板 LAN 指示燈 2 串口插座 1 外接串口 1 外接 USB 接口 2 x USB3.0 接口(從 Asmedia AS1042) 2 x USB2.
您可以在本章節中發現諸多華碩所賦 予本主板的優異特色,利用簡潔易懂的 說明,讓您能很快的掌握本主板的各項 特性,當然,在本章節我們也會提及所 有能夠應用在本主板的新產品技術。 1 第一章:產品介紹
1 章節提綱 1.1 歡迎加入華碩愛好者的行列!........................................................... 1-3 1.2 產品包裝..................................................................................................... 1-3 1.3 序列號標籤................................................................................................ 1-4 1.4 特殊功能.....................................................................................................
1.1 歡迎加入華碩愛好者的行列! 再次感謝您購買此款華碩 Z9PA-D8 系列主板! 本主板的問世除了再次展現華碩對於主板一貫具備的高質量、高性能以 及高穩定度的嚴格要求,同時也添加了許多新的功能以及大量應用在它身上 的最新技術,使得 Z9PA-D8 系列主板成為華碩優質主板產品線中不可多得 的閃亮之星。 在您拿到本主板包裝盒之後,請馬上檢查下面所列出的各項標準配件是 否齊全。 1.
1.3 序列號標籤 在請求華碩技術支持團隊的技術支持之前,請務必留意一下主板的序列 號,此序列號由 12 位字母組成(xxS2xxxxxxxx),如下圖所示。只有當 您了解產品的正確序列號,華碩技術支持團隊成員才能針對您提出的問題提 供更快速而讓您滿意的解決方案。 Z9PA-D8 xxS2xxxxxxxx Made in China 合格 1.4 特殊功能 1.4.1 產品特性 最新中央處理器 本主板支持最新的 LGA2011 封裝的 Intel Xeon® 處理器 E5-2600 產品 系列,內置內存控制器,可支持 4 通道 DDR3 內存(每顆 CPU 支持 4 根內存條)。Intel Xeon ® E5-2600 產品系列處理器支持 Intel QuickPath Interconnect(QPI),系統總線可高達 8.
支持 DDR3 內存 Z9PA-D8 系列主板支持四通道 DDR3 內存,擁有 1600/1333/1066MHZ 數據傳輸速率,可以符合如 3D 繪圖、多媒體與網絡應用等更高的系統帶寬 需求。4 通道 DDR3 架構使系統內存帶寬加倍,最高可達 52GB/s,可以顯著 提升您系統平台的性能,並降低帶寬的瓶頸。另外,內存電壓由 DDR2 的 1.8 V 降低到了現在 DDR3 的 1.5V。降低電壓減少了電能消耗,並降低了 DDR3 內存產生的熱量,是絕佳的內存解決方案。 PCI Express® 3.0 本主板支持最新 E x p r e s s ® 3.0(P C I e 3.0)設備,系統速度與帶寬是 PCIe 2.0 的兩倍,提升系統性能。PCIe 3.0 同時向下兼容 PCIe 1.0/2.
支持 USB 3.0 規格 華碩提供後面板 USB 3.0 接口 — 總共 2 個 USB 3.0 接口。通過最新的 傳輸標準 USB 3.0,輕鬆地與新一代的元件與接口創建鏈接。USB 3.0 的 數據傳輸率為 USB 2.0 的 10 倍。本主板提供最強的便捷性與最快的連接 速度。 溫度、風扇和電壓監測 CPU 溫度受到監控,以防過熱損壞。系統風扇的每分鐘轉速 (RPM) 也被 實時監測。此外,芯片還會監測電壓以確保重要元件上的電壓穩定。 1.4.
本章節描述了所有您在安裝系統元 件時所必須完成的硬件安裝程序。詳 細內容有:處理器與內存、跳線選擇 區設置以及主板的各種設備接口。 2 第二章:硬件設備 信息
2 章節提綱 2.1 主板安裝前................................................................................................ 2-3 2.2 主板概觀..................................................................................................... 2-4 2.3 中央處理器(CPU).............................................................................. 2-8 2.4 系統內存.................................................................................................. 2-13 2.5 擴展插槽................................................
2.
2.2 主板概觀 在您開始安裝之前,請確定您所購買的電腦主機機箱是否可以容納本主 板,並且機箱內的主板固定孔位是否能與本主板的螺絲孔位吻合。 為了優化主板功能,建議您將主板安裝在一個兼容 ATX 2.2 的機箱內。 為方便在電腦主機機箱安裝或取出主板,請務必先將電源供應器 移開!當您安裝或移除主板時,必須確保電源供應器的插頭已經 被移除,否則可能導致主板上的元件損壞。 2.2.1 主板的擺放方向 當您安裝主板到電腦主機機箱內時,務必確認置入的方向是否正確。帶 有外部接口的方向應是朝向主機機箱的後方面板,而且您也會發現主機機箱 後方面板會有相對應的預留孔位。請參考下圖所示。 2.2.
2.2.
Z9PA-D8C 2-6 第二章:硬件設備信息
2.2.4 主板元件說明 插槽 頁數 1. 中央處理器插槽 2-8 2. DDR3 內存插槽 2-13 內置指示燈 頁數 1. 底板管理控制器指示燈(BMC_LED1) 2-21 2. CPU 錯誤指示燈(ERR_CPU1-2) 2-21 3. 內存警告指示燈(ERR_DIMMA1~H1) 2-22 4. CATT 錯誤指示燈(CATTERR_LED1) 2-22 5. Q-Code 指示燈(LED1) 2-23 1. CMOS 配置數據清除(CLRTC1) 2-26 2. 顯示芯片控制器設置(3-pin VGA_SW1) 2-27 3. LAN 控制器設置(3-pin LAN_SW1/LAN_SW2) 2-27 跳線 頁數 4. LSI MegaRAID 或 Intel RSTe 選擇跳線(3-pin RAID_SEL1) 2-28 5. ME 固件強制恢復設置(3-pin ME_RCVR1) 2-28 6. DDR3 散熱事件設置(3-pin DIMMTRIP1) 2-29 7.
2.3 中央處理器(CPU) 本主板具備一個 LGA2011 處理器插槽,是專為 Intel ® Xeon E5-2600 系列處理器所設計。 • 在您購買本主板之後,請確認在處理器插座上附有一個 PnP 保護蓋,並且插座接點沒有彎曲變形。若是保護蓋已經毀壞 或是沒有保護蓋,或者是插座接點已經彎曲,請立即與您的 經銷商聯絡。 • 在 安 裝 完 主 板 之 後 , 請 將 P n P 保 護 蓋 保 留 下 來 。 只 有 L G A2011 插槽上附有 P n P 保護蓋的主板符合 R e t u r n Merchandise Authorization(RMA)的要求,華碩電腦才能 為您處理產品的維修與保修。 • 本保修不包括處理器插座因遺失、錯誤的安裝或不正確的移 除 PnP 保護蓋所造成的毀壞。 2.3.1 安裝中央處理器 請依照以下步驟安裝中央處理器: 1.
2. 以手指壓下固定扳手並將其稍向 左側推(A),這麼做可使扳手脫 離固定扣並鬆開 CPU 輔助安裝盒 (B)。 A B 固定扳手 CPU 安裝盒上的 PnP 保護 蓋是用以保護插槽上的接 腳之用,因此只有在 CPU 安裝妥當之後,才可將其 移除。 3. 依箭頭方向輕輕抬起固定扳手。 4.
5. 將固定扳手往箭頭方向推(F), 抬起安裝盒上蓋(G)。 F G 6. 小心地將 CPU 放入插槽,確認三 角標志對準插槽右上角。 三角標志 CPU 只能以單一方向正確地安裝到主板上的插槽。切記請勿用力 地將 CPU 以錯誤的方向安裝到插槽上,這麼做將可能導致 CPU 與插槽上的接腳損壞。 7.
8. 推下右側固定扳手(J),確保安裝 盒上蓋的邊緣被扳手固定(K)。 K J 9. 將右側固定扳手插入固定扣下。 10.
11. 在 CPU 裸露在外面的區域上滴入 几滴散熱膏,與散熱片接觸。散熱 器散熱膏必須只有很薄的一層。 有些散熱片已有散熱膏。 如果是,則跳過這一步。 注意:請勿食用散熱膏。如進入眼睛或皮膚,請立即清洗,並尋 求專業醫學幫助。 12.
2.4 系統內存 2.4.1 概觀 本主板每 CPU 配置有四組 DDR3 DIMM(Double Data Rate,雙倍數據 傳輸率)內存插槽。 DDR3 內存條擁有與 DDR2 內存條相同的外觀,但是實際上 DDR3 內存 條的缺口與 DDR2 內存條不同,以防止插入錯誤的內存條。DDR3 內存條 擁有更高的性能與更低的能耗。 下圖所示為 DDR3 內存插槽在主板上的位置。 2.4.
2 顆處理器設置 1 2 4 8 DIMM DIMM DIMM DIMM DIMM_A1 DIMM_B1 DIMM_C1 DIMM_D1 X X X X X X X X 2 顆處理器設置 DIMM_E1 DIMM_F1 DIMM_G1 DIMM_H1 1 2 4 8 2-14 DIMM DIMM DIMM DIMM X X X X X X X 第二章:硬件設備信息
2.4.3 安裝內存條 請依照下面步驟安裝內存條: 內存條缺口 1. 先將內存條插槽一端的白色固定卡 扣扳開。 1 2. 將內存條的金手指對齊內存條插槽 的溝槽,並且在方向上要注意金手 指的缺口要對準插槽的凸起點。 2 內存條插槽凸起點 扳開固定卡扣 3. 最後緩緩將內存條插入插槽中,若 無錯誤,插槽一端的白色卡扣會因 內存條置入而自動扣到內存條兩側 的凹孔中。 3 卡扣會在內存條正確 安裝後自動扣上 始終以垂直方向插入內存條,防止內存條缺口損壞。 • 要安裝兩根或更多內存條,請參閱主板包裝中附贈的用戶手 冊的說明。 • 請參閱用戶手冊來獲得最新的內存合格供應商列表。 2.4.4 取出內存條 請依照以下步驟取出內存條: 1. 壓下內存條插槽一端白色的固定 卡扣以鬆開內存條。 2 1 2.
2.5 擴展插槽 考慮到未來會擴展系統性能的可能性,本主板提供了擴展插槽,在接下 來的子章節中,將會描述主板上這些擴展插槽的相關信息。 安裝/移除任何擴展卡之前,請暫時先將電腦的電源線拔出。如 此可免除因電氣殘留於電腦中而發生的意外狀況。 2.5.1 安裝擴展卡 請依照下列步驟安裝擴展卡: 1. 在安裝擴展卡之前,請先詳讀該擴展卡的使用說明,並且要針對該卡作 必要的硬件設置更改。 2. 鬆開電腦主機的機箱蓋並將之取出(如果您的主板已放置在主機內)。 3. 找到一個您想要插入新擴展卡的空置插槽,並以十字螺絲起子鬆開該插 槽位於主機背板的金屬擋板的螺絲,最後將金屬擋板移出。 4. 將擴展卡上的金手指對齊主板上的擴展槽,然後慢慢地插入槽中,並以 目視的方法確認擴展卡上的金手指已完全沒入擴展槽中。 5. 再用剛才鬆開的螺絲將擴展卡金屬擋板鎖在電腦主機背板以固定整張 卡。 6. 將電腦主機的機箱蓋裝回鎖好。 2.5.2 設置擴展卡 在安裝好擴展卡之後,接著還須通過軟件設置來調整該擴展卡的相關設 置。 1.
2.5.3 指定中斷要求 標準中斷要求使用一覽表 IRQ 0 1 2 3* 4* 5* 6 7* 8 9* 10* 11* 12* 13 14* 15* 優先權 1 2 11 12 13 14 15 3 4 5 6 7 8 9 10 指定功能 系統計時器 鍵盤控制器 可編程中斷 通訊端口 (COM2) 通訊端口 (COM1) -軟驅控制器 -系統 CMOS/實時鐘 ACPI 模式 預留給 PCI 設備使用 預留給 PCI 設備使用 PS/2 兼容鼠標端口 數值數據處理器 第一組 IDE 通道 第二組 IDE 通道 *:這些通常是留給 ISA 或 PCI 接口卡使用。 2.5.4 PCI Express x16 插槽(x16 link) 板載的 PCIE 2 插槽(插槽位置 5)與 PCIE 4 插槽(插槽位置 3)提供 一個 x16 Gen3 link 至 CPU1,在 PCIE1/3 插槽被使用時會自動切換為 x8 Link。此插槽可支持顯卡以及服務器等級的多種高性能附加卡。 2.5.
插槽編號 5(插槽 6) 4(插槽 5) 3(插槽 4) 2(插槽 3) 1(插槽 2) 插槽說明 PCI-E x8(x8 Gen3 Link),支持 MIO-892 聲卡 PCI-E x16(x16 Gen3 Link)(當插槽 6 被使用時自動切換為 x8 Link) PCI-E x8(x8 Gen3 Link) PCI-E x16(x16 Gen3 Link)(當插槽 4 被使用時自動切換為 x8 Link) PCI-E x8(x4 Gen2 Link) 2.5.
2.5.7 安裝華碩 PIKE RAID 卡 請按照以下步驟安裝選購的華碩 PIKE RAID 卡到主板上: 1. 找到主板上的 PIKE RAID 卡插槽位置。 2.
2.5.8 安裝 ASMB6 管理卡 請依照以下步驟安裝選購的 ASMB6 到主板上: 1. 找到主板上的 ASMB6 插槽位置。 2. 將 ASMB6 管理卡向下插入。 2.5.9 安裝聲卡 1. 找到主板上的 M I O 插槽位置。然後將 M I O-892 聲卡的金手指對準 MIO1 卡插槽。 2. 向下插入聲卡。確保聲卡已牢牢固定在 MIO 插槽上。 3.
2.6 內置指示燈 1. 底板管理控制器指示燈(BMC_LED1) BMC 指示燈須配合華碩 ASMB6 管理設備使用,指示它的初始化狀 態。當連接 PSU,且系統關閉時,華碩 ASMB6 管理設備開始系統初始 化大約一分鐘。初始化完成後 BMC 指示燈開始閃爍。 • 當您安裝了華碩 ASMB6 后,此指示燈才生效。 • 當 AC 電源重新接通后,系統需等待約 30 秒才能啟動。 2.
3. 內存警告指示燈(ERR_DIMMA1~H1) 當內存出現錯誤時,對應的內存警告指示燈亮起。 當您安裝了華碩 ASMB6 后,警告指示燈才生效。 4.
5.
Q-Code 表 Action Normal boot PHASE Security Phase PEI(Pre-EFI initialization) phase POST CODE TYPE 01 02 03 Progress Progress Progress 06 04 10 15 19 78~00 A1 A3 A7 A8 A9 AA AB AC AD AE AF 2F B0 B1 AF B4 B2 B3 B5 B6 B7 B8 B9 BA BB BC BF 5A 31 32 34 36 4F Progress Progress Progress Progress Progress Progress MRC Progress MRC Progress MRC Progress MRC Progress MRC Progress MRC Progress MRC Progress MRC Progress MRC Progress MRC Progress MRC Progress Progress MRC Progress MRC Progress MRC Progress MRC
Action PHASE Normal boot DXE(Driver Execution Environment) phase POST CODE 60 61 62 63 68 69 6A 70 71 72 78 79 BDS(Boot 90 Device 91 Selection) phase 92 93 94 95 96 97 98 99 9A 9B 9C 9D b2 b3 b4 b6 b7 A0 A1 A2 A3 A8 A9 AB AD AE Operating 17 system phase 18 19 20 21 22 23 24 25 TYPE DESCRIPTION Progress Progress Progress Progress Progress Progress Progress Progress Progress Progress Progress Progress Progress Progress Progress Progress Progress Progress Progress Progress Progress Progress Progress Pr
2.7 跳線選擇區 1. CMOS 數據清除(CLRTC1) 主板上的 CMOS 存儲器中記載著正確的時間與系統硬件配置等數據, 這些數據並不會因電腦電源的關閉而遺失數據與時間的正確性,因為這個 CMOS 的電源是由主板上的鋰電池所供應。 想要清除這些數據,可以依照下列步驟進行: 1. 關閉系統電源,拔掉電源適配器; 2. 將 CLRTC1 跳線帽由 [1-2](默認值)改為 [2-3] 約 5~10 秒鐘 (此時即清除 CMOS 數據),然后再將跳線帽改回 [1-2]; 3. 插上電源適配器,開啟電源; 4.
2. 顯示芯片控制器設置(3-pin VGA_SW1) 此跳線可讓您開啟或關閉板載的顯示芯片控制器。將跳線設置為 [1-2] 短路為開啟顯示芯片功能。 3.
4. LSI MegaRAID 或 Intel RSTe 選擇跳線(3-pin RAID_SEL1) 此跳線用來選擇 PCH SATA RAID 模式以使用 LSI MegaRAID 軟件 或 Intel® Rapid Storage Technology enterprise 3.0 RAID。若您要使用 LSI MegaRAID 軟件 RAID 應用程序 (默認),請設為 [1–2] 短路;若要 使用 Intel® Rapid Storage Technology Enterprise Option ROM 應用程 序,請設為 [2–3] 短路 5.
6. DDR3 熱量事件設置(3-pin DIMMTRIP1) 此跳線用來開啟/關閉 DDR3 DIMM 熱量感應事件的接針。 7. PMBus 1.
2.8 元件與外圍設備的連接 2.8.1 後側面板接口 1. PS/2 鍵盤/鼠標接口:將 PS/2 鍵盤/鼠標插頭連接到此端口。 2. DM_LAN 1(RJ-45)端口(僅 Z9PA-D8 SKU 支持):此接口可經 網絡集線器連接至局域網(LAN),實現千兆連接,用於 BMC 管理功 能。請參考下頁的表格瞭解 DM_LAN1 與 LAN 端口燈號說明。 3. L A N 2 ( R J - 4 5 ) 端 口 : 此 接 口 可 經 網 絡 集 線 器 連 接 至 局 域 網 (LAN),實現千兆連接。請參考下表中各燈號的說明。 4. USB 2.0 設備接口(1 和 2):這兩組 4-pin 串行總線(USB)接口可 連接到使用 USB 2.0 規格的硬件設備。 5. USB 3.0 設備接口(1 和 2):這兩組串行總線(USB)接口可連接到 使用 USB 3.0 規格的硬件設備。 6. LAN 1 (RJ-45) 端口:此接口可經網絡集線器連接至局域網(LAN), 實現千兆連接。請參考下表中各燈號的說明。 7.
2.8.2 內部連接端口 1. Serial ATA 6.0/3.0Gb/s 設備接口(7-pin SATA6G_1-2 [淺藍];7-pin SATA3G_3-6 [黑色]) 這些接口可支持使用 Serial ATA 6.0/3.0Gb/s 數據線連接 Serial ATA 6.0/3.0Gb/s 硬盤或光驅。 2.
3. 硬盤讀寫動作指示燈連接排針(4-pin HDLED1) 這個排針用來連接至 SAS 或 SATA 附加卡連線。連接到 SAS 或 SATA 附加卡的任何設備的讀寫動作都會導致前面板 LED 指示燈亮起。 4. USB 擴展套件排線插槽(10-1 pin USB34、USB56;A-Type 10) 這些插槽可用來連接 USB 2.0 擴展端口。將 USB 擴展套件連接線連 接到 USB34 與 USB56,然後將擴展套件安裝到機箱背部的一箇空置插 槽位置。這三組 USB 擴展套件排線插槽支持 USB 2.
5.
6.
7. TPM 連接排針(20-1 pin TPM1) 這組連接排針支持 TPM 系統,該系統能夠安全存儲按鍵,電子證書, 密碼與數據。同時,該系統也有助於提高網絡安全,維護數字身份(digital identities),保證平臺完整。 8.
9. EATX 主板電源插座 (24-pin EATXPWR1、8-pin EATX12V1、8-pin EATX12V2) 這個插座為提供給 EATX 電源使用。由電源所提供的連接插頭已經過 特別設計,只能以一個特定方向插入主板上的電源插座。找到正確的插 入方向後,僅需穩穩地將之套進插座中即可。 • 使用 95W 或更低電壓 CPU 時,請不要忘記連接 24+8-pin 電 源插座,否則系統將無法開機。 • 使 用 115 W 或 更 高 電 壓 C P U 時,請 不 要 忘 記 連 接 24+8+8-pin 電源插座,否則系統將無法開機。 • 如果您想要安裝其他的硬件設備,請務必使用較高功率的電 源供應器以提供足夠的設備用電需求。若電源供應器無法提 供設備足夠的用電需求,則系統將會變得不穩定或無法開 啟。 • 請確保您使用的電源可以滿足您系統的最低用電需求。最低 用電需求:1) 500W 2) 全部 +12V 電壓輸出 > 20A.
10.
11. 系統控制面板連接排針(20-1 pin PANEL1) 這一組連接排針包括了數個連接到電腦主機前面板的功能接針。 1. 系統電源指示燈連接排針(3-pin PLED) 這組排針可連接到電腦主機面板上的系統電源指示燈。在您啟動電 腦並且使用電腦的情況下,該指示燈會持續亮著;而當指示燈閃爍 亮著時,即表示電腦正處於睡眠模式中。 2. 信息指示燈連接接針(2-pin MLED) 這組排針可將信息指示燈的數據線連接至前面板信息指示燈。信 息指示燈顯示啟動狀態。啟動過程中信息指示燈會一直閃爍,直 到進入系統。 3. 機箱喇叭連接排針(4-pin SPEAKER) 這組四腳位排針連接到電腦主機機箱中的喇叭。當系統正常開機 便可聽到嗶嗶聲,若開機時發生問題,則會以不同長短的音調來 警告。 4. 硬盤動作指示燈連接接針(2-pin HDDLED) 您可以連接此組 IDE_LED 接針到電腦主機面板上的 IDE 硬盤動作 指示燈號,如此一旦 IDE 硬盤有讀寫動作時,指示燈隨即亮起。 5.
12.輔助系統控制面板連接排針(20-2 pin AUX_PANEL1) 本組接針支持前面板上的多個功能,包括前面板 SMB,Locator LED 指示燈與開關,機箱開啟警告連接排針,以及網絡狀態指示燈。 1. 前面板 SMBus 連接排針(6-1 pin FPSMB) 這組連接排針可以讓您連接 SMBus(系統管理總線)設備。可以 提供給系統中傳輸率較慢的外圍設備及電源管理設備之間的溝通 使用。 2. 網絡狀態指示燈(2-pin LAN1_LED, LAN2_LED) 這兩組 2-pin 排針可通過 Gigabit 網絡指示燈連接線來連接到 LAN 的狀態指示燈。這個燈閃爍時則表示網絡已正常連接動作。 3.
2-40 第二章:硬件設備信息
本章節說明開啟電腦電源的順序, 以及電腦開機後所發出各種不同類型 嗶聲的代表意義。 3 第三章:開啟電源
3 章節提綱 3.1 第一次啟動電腦....................................................................................... 3-3 3.2 關閉電源.....................................................................................................
3.1 第一次啟動電腦 1. 確認所有排線與接腳都接妥,然後蓋上機箱的外蓋。 2. 確定所有的開關都已關閉。 3. 將電源線接上機箱背面的電輸入插座。 4. 情況許可的話,最好將電源線路上加接突波吸收/保護器。 5. 您可以先開啟以下外圍設備的電源: a. 顯示器 b. 外接存儲設備(從連接鏈中的最後一個設備開始) b. 系統電源供應器 6. 送電之後,機箱面板上應該會有電源指示燈亮起才對。如果是使用 ATX 電源供應器的話,必須等到面板按鈕被觸碰後才會啟動電源,電源指示 燈此時才會亮起。如果您的顯示器符合綠色省電標準,或具備電源待機 功能,則需要等系統 LED 指示燈亮起後,顯示器指示燈才會亮起或由橙 色切換為綠色。 如果開機過程一切順利的話,不久就可以在顯示器上看到畫面了,如果 送電之後超過 30 秒而畫面沒有動靜的話,表示電腦的設置尚有問題存 在,請再進一步地的檢查各項動作,如果還是不行,就需要向廠商求助 了! 7.
3.2 關閉電源 3.2.1 使用操作系統關機功能 如果您使用的操作系統為 Windows® 2008 Server: 1. 點擊“開始”,將光標放到“登出”右邊的小三角上,點擊“關機”。 2. 在“關閉事件跟蹤程序”對話框中選擇您要關閉計算機的原因。 3. 請確認您勾選了“計划的”複選框。 4. 如果需要,您可以輸入註釋。 5. 點擊“確定”。 3.2.
在電腦系統中,BIOS 程序調校的優 劣與否和整個系統的運行性能有極大的 關係。針對您自己的配備來作最優化 BIOS 設置是讓您的系統性能再提昇的 要角。接著本章節將逐一說明 BIOS 程 序中的每一項設置。 4 第四章:BIOS 程序設置
4 章節提綱 4.1 管理、更新您的 BIOS 程序................................................................. 4-3 4.2 BIOS 程序設置......................................................................................... 4-7 4.3 主菜單(Main)................................................................................... 4-10 4.4 高級菜單(Advanced).................................................................... 4-11 4.5 服務器管理菜單(Server Mgmt)................................................ 4-35 4.
4.1 管理、更新您的 BIOS 程序 下列軟件讓您可以管理與更新主板上的 BIOS(Basic Input / Output system)設置。 1. ASUS CrashFree BIOS 3 (當 BIOS 文件遺失或損壞時,可啟動 U 盤來 恢復 BIOS 。) 2. ASUS EZ Flash 2 (使用軟盤或 USB 閃存盤更新 BIOS。) 3. BUPDATER (USB 啟動盤在 DOS 模式下更新 BIOS。) 上述軟件請參考相關章節的詳細使用說明。 建議您先將主板原始的 BIOS 程序備份到 U 盤中,以備您往後需 要再度安裝原始的 BIOS 程序。使用 BUPDATER 來拷貝主板原 始的 BIOS 程序。 4.1.
4.1.2 使用華碩 EZ Flash 2 升級 BIOS 程序 華碩 EZ Flash 2 程序讓您能輕鬆地升級 BIOS 程序,可以不必再到操作 系統模式下運行。 從華碩網站上(www.asus.com.cn)下載最新的 BIOS 文件。 請依據以下步驟使用 EZ Flash 2 升級 BIOS: 1. 將含有最新 BIOS 文件的 USB 閃存盤插入 USB 接口。 2. 進入 BIOS 設置程序。來到 Tool 菜單選擇 EZ Flash 並按下 <Enter> 鍵將其開啟。 Exit ASUSTek EZ Flash 2 Utility V01.04 Flash Info MODEL: Z9PA-D8 VER: 3005 DATE: 07/25/2012 fs0:\ Drive Folder Info fs0:\ fs1:\ 12/09/10 10:23p 4194304 Z9PA-D8.
•本功能僅支持採用 FAT 32/16 格式單一扇區的 USB 設備, 如 USB 閃存盤。 •當升級 BIOS 時,請勿關閉或重置系統以避免系統開機失敗。 請確定讀取 B I O S 中的出廠默認值以保證系統的兼容性與穩定 性。按下 并選擇【Yes】加載 BIOS 初始設置。 4.1.3 使用 BUPDATER 升級 BIOS 程序 BUPDATER 程序讓您在 DOS 操作系統中,使用含有已更新的 BIOS 文 件的 USB 啟動盤來升級 BIOS 程序。 以下 BIOS 畫面僅供參考。實際畫面可能會有所不同。 升級 BIOS 文件: 使用 BUPDATER 升級 BIOS 程序 1. 訪問華碩網站 www.asus.com.cn 下載最新主板 BIOS 文件,并將其保存 在 U 盤中。 2. 訪問華碩技術支持網站 support.asus.com,複製 BUPDATER 程序 (BUPDATER.exe) 至您預先創建的 USB 啟動盤。 3. 在 DOS 模式中啟動系統,在提示符處輸入: BUPDATER /i[filename].
4. BUPDATER 先確認文件,然後開始升級 BIOS。 ASUSTek BIOS Update for DOS V1.06 (09/08/04) FLASH TYPE: MXIC 25L1605A Current ROM BOARD: Z9PA-D8 VER: 0203 DATE: 08/24/2012 PATH: Update ROM BOARD: Z9PA-D8 VER: 0206 DATE: 09/30/2012 WARNING! Do not turn off power during flash BIOS Note Writing BIOS: 當更新 BIOS 時請不要關閉或重啟系統,以防止系統啟動失敗! 5. 當 BIOS 更新完畢后該程序會返回 DOS 命令。請從硬盤重新啟動系統。 The BIOS update is finished! Please restart your system.
4.2 BIOS 程序設置 主板擁有一片可編程的固件芯片,您可以依照“4.
4.2.1 BIOS 程序菜單介紹 菜單項目 Main 功能表列 在線操作說明 設置值 Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Event Logs Boot Monitor Security Tool Exit BIOS Information BIOS Vendor Core Version Compliancy BIOS Version Build Date American Megatrends 4.6.5.3 UEFI 2.3; PI 1.
4.2.3 菜單項目 於功能表列選定選項時,被選擇的功能將會反白,如右圖紅線所框選的 地方,即選擇 Main 菜單所出現的項目。 點擊菜單中的其他項目(如:E v e n t L o g s、A d v a n c e d、M o n i t o r、 Boot、Tool 與 Exit)也會出現該項目不同的選項。 4.2.4 子菜單 在菜單畫面中,若功能選項前面有一個小三角形標記,代表此項目下有 子菜單,您可利用方向鍵來選擇,並按下 鍵來進入子菜單。 4.2.5 導航鍵 在菜單屏幕右下角有設置 BIOS 程序的導航鍵。使用導航鍵選擇菜單中的 項目并更改設置。 4.2.6 在線操作說明 在菜單畫面的右上方為目前所選擇的作用選項的功能說明,此說明會依 選項的不同而自動更改。 4.2.
4.3 主菜單(Main) 當您進入 BIOS 設置程序時,首先出現的第一個畫面即為主菜單,內容如 下圖。 Main Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Event Logs Boot Monitor Security Tool Exit BIOS Information BIOS Vendor Core Version Compliancy BIOS Version Build Date American Megatrends 4.6.5.3 UEFI 2.3; PI 1.
4.4 高級菜單(Advanced) 高級菜單可讓您改變中央處理器與其他系統設備的細部設置。 注意!在您設置本高級菜單的設置時,不正確的數值將導致系統 損壞。 Main Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
插槽 1 CPU 信息 查看特定插槽的 CPU 信息。 Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Socket 1 CPU Information Intel(R) Xeon(R) CPU E5-2650 @ 2.00GHz CPU Signature 206d6 Microcode Patch 616 Max CPU Speed 2000 MHz Min CPU Speed 1200 MHz Processor Cores 8 Intel HT Technology Supported Intel VT-X Technology Supported L1 L1 L2 L3 Data Cache Code Cache Cache Cache 32kB x8 32kB x8 256kB x8 20480 kB →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt.
Adjacent Cache Line Prefetch [Enabled] 本項目允許您開啟或關閉相鄰緩存線的預取。設置值有:[D i s a b l e d] [Enabled] DCU Streamer Prefetcher [Enabled] 本項目允許您開啟或關閉下一個 L1 數據線的預取。設置值有: [Disabled] [Enabled] DCU IP Prefetcher [Enabled] 本項目允許您開啟或關閉下一個 L1 數據線的預取,依據連續負載曆史記 錄。設置值有:[Disabled] [Enabled] Intel(R) Virtualization Tech [Enabled] Intel® Virtualization 技術支持一塊硬盤上分別或同時運行多個操作系統, 可讓一個系統虛擬地發揮多個系統的功能。設置值有:[Disabled] [Enabled] Local APIC Mode [Auto] 選擇 APIC 模式。設置值有:[Auto] [x2APIC] [xAPIC] 4.4.
Turbo Mode [Enabled] 設置值有:[Disabled] [Enabled] P-STATE Coordination [HW_ALL] 本項目允許您變更 P-STATE Coordination 類型。設置值有:[HW_ALL] [SW_ALL] [SW_ANY] CPU C3 Report [Disabled] 本項目允許您開啟或關閉 CPU C3(ACPI C2) 報告。設置值有:[Disabled] [Enabled] CPU C6 Report [Enabled] 本項目允許您開啟或關閉 CPU C6(ACPI C3) 報告。設置值有:[Disabled] [Enabled] CPU C7 Report [Disabled] 本項目允許您開啟或關閉 CPU C7(ACPI C3) 報告。設置值有:[Disabled] [Enabled] Package C State limit [C6] 本項目允許您設置封包 C State 限制。設置值有:[C0] [C2] [C6] [C7] [No Limit] Energy Performance [Balanced Perfo
4.4.3 芯片組設置(Chipset Configuration) Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Memory Configuration CPU II0 Bridge Configuration PCH Configuration Intel(R) VT for Directed I/O Configuration QPI Configuration Page QPI Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
Memory Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Compatibility RID [Enabled] Memory Configuration Total Memory Current Memory Mode Currently Memory Speed ECC Mirroring Sparing Memory Mode DDR Speed Channel Interleaving Rank Interleaving Patrol Scrub Demand Scrub Data Scrambling Device Tagging Thermal Throtting Enable High Temp.
Patrol Scrub [Disabled] 本項目用來開啟或關閉 Patrol Scrub。設置值有:[Disabled] [Enabled] Demand Scrub [Enabled] 本項目用來開啟或關閉清洗內存需求。設置值有:[Enabled] [Disabled] Data Scrambling [Enabled] 本項目用來開啟或關閉數據抓取。設置值有:[Enabled] [Disabled] Device Tagging [Disabled] 本項目用來開啟或關閉設備標籤。設置值有:[Enabled] [Disabled] Thermal Throtting [CLTT] 設置值有:[Disabled] [OLTT] [CLTT] Enable High Temp [Disabled] 設置值有:[Disabled] [Enabled] Allow 2x Refresh [Enabled] 設置值有:[Disabled] [Enabled] Altitude [300 M] 設置系統海拔高度。設置值有:[A u t o] [300 M] [900 M] [1500 M] [30
DIMM Information Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced CPU1 DIMM Information Node Node Node Node 0 0 0 0 Ch Ch Ch Ch 0 0 1 1 Dimm Dimm Dimm Dimm A1 A2 B1 B2 Present 1024 MB Indep Not Present Not Present Not Present CPU2 DIMM Information CPU IIO Bridge Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
PCH Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Name Stepping Patsburg 06 (C1 Stepping) SB Chipset Configuration PCH Compatibility RID GbE Controller [Disabled] [Disabled] Deep Sx Onboard SATA RAID Oprom [Disabled] [Enabled] Audio Configuration Azalia HD Audio [Enabled] High Precision Event Timer Configuration High Precision Timer [Enabled] Support for PCH Compatibility Revision ID(CRID) functionality.
Audio Configuration Azalia HD Audio [Enabled] 本項目用來開啟或關閉 Azalia HD Audio。 設置值有:[Disabled] [Enabled] High Precision Event Timer Configuration High Precision Timer [Enabled] 允許您開啟或關閉高精度事件計時器。設置值有:[Disabled] [Enabled] Intel(R) VT for Directed I/O Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Intel(R) VT-d [Disabled] Enables or Disables BIOS ACPI Auto Configuration.
4.4.4 PCH SATA 設置(PCH SATA Configuration) Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced SATA SATA SATA SATA SATA SATA Port1 Port2 Port3 Port4 Port5 Port6 Not Not Not Not Not Not SATA Mode S.M.A.R.T. Status Check Present Present Present Present Present Present (1)IDE Mode. (2)AHCI Mode. (3)RAID Mode.
4.4.5 PCI 子系統設置(PCI Subsystem Settings) Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced PCI Bus Driver Version PCI Common Settings PCI Latency Timer VGA Palette Snoop PERR# Generation SERR# Generation Load RT32 Image V 2.05.02 [32 PCI Bus Clocks] [Disabled] [Disabled] [Disabled] [Enabled] PCI Express Settings PCIE Slot Option Rom Configuration In case of multiple Option ROMs (Legacay and EFI Compatible), specifies what PCI option ROM to lanuch.
PCI Express Settings Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced PCI Express Link Register Settings ASPM Support [Disabled] WARNING: Enabling ASPM may cause some PCI-E device to fail Enables or DisablesPCI Express Device Relaxed Ordering. Link Training Timeout (uS) 400 →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219.
PCIE Slot Option Rom Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Legacy 0pROM Support Launch Storage 0pROM [Enabled] PCIE1 Option Rom PCIE2 Option Rom PCIE3 Option Rom PCIE4 Option Rom PCIE5 Option Rom PIKE Option Rom [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] Enables or disables boot option for legacy mass storage device with option ROM. →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt.
4.4.6 USB 設置(USB Configuration) Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced USB Configuration USB Devices: 1 Keyboard, 2 Hubs Legacy USB Support USB3.0 Support XHCI Hand-off EHCI Hand-off Port 60/64 Emulation [Enabled] [Enabled] [Enabled] [Disabled] [Enabled] USB hardware delays and time-outs: USB transfer time-out [20 sec] Device reset time-out [20 sec] USB Ports Configuration Enabled Legacy USB support.
USB hardware delays and time-outs USB transfer time-out [20 sec] 允許您選擇 USB 轉移暫停值。設置值有:[1 sec] [5 sec] [10 sec] [20 sec] Device reset time-out [20 sec] 允許您選擇 USB 設備重置暫停值。設置值有:[10 sec] [20 sec] [30 sec] [40 sec] USB Ports Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
4.4.7 可信運算(Trusted Computing) Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Configuration TPM SUPPORT [Enabled] Current Status Information No Security Device Found Enables or Disables BIOS support for security device. O.S. will not show Security Device. TCG EFI protocol and INT1A interface will not be available. TPM SUPPORT [Enabled] 允許您開啟或關閉 TPM 支持。設置值有:[Disabled] [Enabled] 4.4.
4.4.9 WHEA 設置(WHEA Configuration) Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced WHEA Support [Enabled] Enable or disable Windows Hardware Error Architecture. WHEA Support [Enabled] 允許您開啟或關閉 Windows Hardware Error Architecture 功能。設置值 有:[Disabled] [Enabled] 4.4.10 APM 設置(APM setting) Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
4.4.11 串口控制臺重定向(Serial Port Console Redirection) Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced COM1 Console Redirection Console Redirection Settings [Disabled] COM2 Console Redirection Console Redirection Settings [Enabled] Serial Port for Out-of-Band Management/ Windows Emergency Management Services (EMS) Console Redirection [Disabled] Console Redirection Settings Consloe Redirection Enable or Disable.
Data Bits [8] 設置值有:[7] [8] Parity [None] 奇偶校驗位會與數據位數一起偵查一些傳輸錯誤。[Mark] 與 [Space] 不能夠偵測錯誤。 [None] [Even] [Odd] [Mark] [Space] 無奇偶位。 奇偶校驗位為 0 並且 1 的數量在數據位數中是偶數個。 奇偶校驗位為 0 并且 1 的數量在數據位數中是奇數個。 奇偶校驗位總是 1。 奇偶校驗位總是 0。 Stop Bits [1] 停止位指的是串聯數據包的終端。設置值有:[1] [2] Flow Control [Hardware RTS/CTS] 流量控制可防止緩衝過度時的數據丟失。設置值有:[N o n e] [Hardware RTS/CTS] VT-UTF8 Combo Key support [Enabled] 開啟或關閉對 A N S I/V T100 終端的組合鍵支持。設置值有: [Disabled] [Enabled] Recorder Mode [Disabled] 開啟此選項只能發送文本。該選項用來捕捉終端數據。設置值有: [Disabled] [Enab
COM2 Console Redirection [Enabled] 開啟或關閉操作臺重定向功能。設置值有:[Disabled] [Enabled] Console Redirection Settings 請參閱在 COM1 下的【Console Redirection Settings】選項的內容。 Serial Port for Out-of-Band Management/Windows Emergency Management Services (EMS) Console Redirection [Disabled] 開啟或關閉操作臺重定向功能。設置值有:[Disabled] [Enabled] 只有當【Console Redirection】項目設為 [Enabled] 時以下項目 才會出現。 Console Redirection Settings Out-of-Band Mgmt Port [COM1] Microsoft Windows Emergency Management Services (EMS) 允許 Windows Server OS 通過串口遠程管理。設置值有:[CO
4.4.12 板載網絡設置(Onboard LAN Configuration) Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
4.4.13 ME 子系統(ME Subsystem) Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Intel ME Subsystem Configuration ME BIOS Interface Version 1.2 ME Version ME FW Status Value : ME FW State : ME FW Operation State: 2.1.5.95 0xf0345 SPS ME FW Active M0 without UMA ME FW Error Code: No Error BIOS Booting Mode: Performance Optimized ME Ext FW Status value: Cores Disabled: ME FW SKU Information: End-of-POST Status: ME Subsystem Help.
Asmedia USB 3.0 Controller [Enabled] 本項目用來開啟胡關閉 Asmedia USB 3.0。設置值有:[Disabled] [Enabled] Asmedia USB 3.0 Battery Charging S [Enabled] 本項目用來開啟或關閉 Asmedia USB 3.0 電池充電功能。設置值有: [Disabled] [Enabled] 4.4.15 運行錯誤記錄(Runtime Error Logging) Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
4.5 服務器管理菜單(Server Mgmt) Server Mgmt 菜單顯示服務器管理狀態,並允許您變更設置。 Server Mgmt 菜單只有在主板上安裝了 ASMB 卡之後才會出 現。 Main Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Server Mgmt Event Logs Boot Monitor Security Tool Exit BMC Firmware: O/S Watchdog Timer O/S Wtd Timer Timeout O/S Wtd Timer Policy 1.
4.5.1 系統時間記錄(System Event Log) Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Server Mgmt Enabling/Disabling Options SEL Components [Disabled] Erasing Settings Erase SEL When SEL is Full [No] [Do Nothing] Note: All values changed here do not take effect until computer is restarted. Change this to enable or disable all features of system Event Logging during boot. →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt.
4.5.2 BMC 網絡設置(BMC network configuration) Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Server Mgmt BMC network configuration DM_LAN1 DM_LAN1 IP Address in BMC: DM_LAN1 Subnet Mask in BMC: DM_LAN1 Gateway Address in BMC : DM_LAN1 MAC Address in BMC: DM_LAN1 Address Source in BMC: Configuration Address source 000.000.000.000 000.000.000.000 000.000.000.000 00.E0.18.02.21.DC DHCP Mode [Previous State] Lan1 Lan1 Lan1 Lan1 Lan1 000.000.000.000 000.000.000.000 000.000.000.000 00.
4.6 事件記錄菜單(Event Logs) 事件記錄菜單(Event Logs)選項允許您更改事件記錄設置以及查看系 統事件記錄。 Main Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Server Mgmt Event Logs Boot Monitor Security Tool Exit Press to change the Smbios Event Log configuration. Change Smbios Event Log Settings View Smbios Event Log View System Event Log →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.
When Log is Full [Do Nothing] 允許您選擇當事件記錄滿時的反應選項。設置值有:[D o N o t h i n g] [Erase Immediately] Smbios Event Log Standard Settings Log System Boot Event [Disabled] 允許您開啟或關閉系統啟動項記錄。設置值有:[Enabled] [Disabled] MECI [1] 允許您調節 MECI 的設置值。使用 <+> 與 <-> 鍵調節值。設置值在 1 至 33 之間。 METW [60] 允許您調節 METW 的設置值。使用 <+> 與 <-> 鍵調節值。設置值在 0 至 99 之間。 Custom Option Log OEM Codes [Enabled] 允許您開啟或關閉 EFI 狀態編碼記錄作為 OEM 編碼。設置值有: [Disabled] [Enabled] Convert OEM Codes [Disabled] 允許您開啟或關閉 EFI 狀態編碼轉變為標準 Smbios 編碼。設置值 有:[Disabled] [Enabled] V
4.7 啟動菜單(Boot) 本菜單可讓您改變系統啟動設備與相關功能。請選擇下列選項並按下 <Enter> 鍵來顯示設置選項。 Main Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
Interrupt 19 Capture [Enabled] 允許 Option ROM 阻止 interrupt 19。設置值有:[Disabled] [Enabled] Boot Device Seeking [Endless PXE] [Endless PXE] 繼 續 尋 找 遠 程 啟 動 畫 面 直 到 找 到 或 用 戶 終 止 ( 按 下 Ctrl+Alt+Del)。 [Normal] 尋找一次遠程啟動畫面後停止。 UEFI Boot [Disabled] 開啟或關閉 UEFI Boot。設置值有:[Disabled] [Enabled] Boot Option Priorities 本項讓您自行選擇啟動盤並排列開機備順序。屏幕上顯示的設備數量依 據系統中安裝的設備而定。 • 要選擇系統開機的啟動備,請在 ASUS 的圖標出現時按下 。 • 要以安全模式進入 Windows 操作系統,在開機自檢完成後, 按下 。 設置網絡設備的啟動順序。 Boot Option #1/#2 [JetFlashTranscend ...
4.7.1 CSM 參數(CSM parameters) 按下 以更改 CSM 參數設置。 Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Boot Launch CSM Boot option filter Launch PXE OpROM policy Launch Storage OpROM policy Launch Video OpROM policy [Always] [UEFI and Legacy] [Legacy only] [Legacy only] [Legacy only] Other PCI device ROM priority [Legacy OpROM] This option controls if CSM will be launched. →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt.
4.8 監控菜單(Monitor) 本菜單可顯示系統溫度或電源狀態并允許您改變風扇設置。 Main Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Event Logs Boot Monitor Security Tool Exit CPU1 Temperature CPU2 Temperature TR1 Temperature TR2 Temperature CPU FAN1 Speed CPU FAN2 Speed FRNT FAN1 Speed FRNT FAN2 Speed FRNT FAN3 Speed FRNT FAN4 Speed REAR FAN1 Speed REAR FAN2 Speed +VTT_CPU VCORE1 +VDDQ_AB_CPU1 +VDDQ_CD_CPU1 +VDDQ_EF_CPU2 +VDDQ_GH_CPU2 +5VSB +5V +12V +3.3V VBAT +3.
4.9 安全性菜單(Security) 此菜單用於更改系統安全性。 Main Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Event Logs Boot Monitor Security Tool Exit Password Description If ONLY the Administrator's password is set, then this only limits access to Setup and is only asked for when entering Setup If ONLY the User's password is set, then this is a power on password and must be entered to boot or enter Setup.
用戶密碼(User Password) 若您已經設置了一個用戶密碼,您必須輸入用戶密碼進入系統。 請依照以下步驟設置用戶密碼: 1. 選擇【User Password】項目並按下 <Enter>。 2. 在“Create New Password”窗口出現時,輸入欲設置的密碼,輸入完 成按下 <Enter>。 3. 在彈出的確認窗口中再一次輸入密碼以確認密碼正確。 請依照以下步驟變更用戶密碼: 1. 選擇【User Password】項目並按下 <Enter>。 2. 在“Enter Current Password”窗口出現時,輸入現在的密碼,輸入完 成按下 <Enter>。 3. 在“Create New Password”窗口出現時,輸入欲設置的新密碼,輸入 完成按下 <Enter>。 4.
4.10 工具菜單(Tool) 本工具菜單可以讓您針對特別功能進行設置。請選擇菜單中的選項並按下 鍵來顯示子菜單。 Main Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Server Mgmt Event Logs Boot Monitor Security Tool Exit ASUS EZ Flash 2 Utility Be used to update BIOS ASUS EZ Flash 2 Utility 本項目可以讓您運行 ASUS EZ Flash。請參考“4.1.2 使用華碩 EZ Flash 2 升級 BIOS 程序”部分的說明。 4.11 退出 BIOS 程序(Exit) 本菜單可讓您保存或刪除您對 BIOS 選項的更改。 Main Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
Save Changes & Reset 完成設置後,在“Exit”菜單中選擇此項目以保存您的設置。選擇了該項 目,或者按下 <F10> 鍵後,系統會彈出一個確認窗口,點擊 [Yes] 即可 保存變更並退出。 Discard Changes & Reset 本項目可放棄您所做的更改並進行重設。當您選擇此項目後,系統會彈 出一個確認窗口,點擊 [Yes] 放棄更改並進行重設。 Restore Defaults 本項目允許您恢復/加載默認值。當您選擇此項目後,系統會彈出一個確 認窗口,點擊 [Yes] 即可加載默認值。 Boot Override 這些項目顯示可用設備。屏幕上顯示的設備數量依據系統中安裝的設備 而定。選擇一個項目,從該設備啟動。 Launch EFI Shell from filesystem device 本項目允許您嘗試登入可用的文件系統設備中的 EFI Shell 應用程序 (shellx64.
4-48 第四章:BIOS 程序設置
在本章節中,我們將介紹服務器內 所支持的磁盤陣列的設置與說明。 5 第五章:RAID 磁盤陣列設置
5 章節提綱 5.1 RAID 功能設置......................................................................................... 5-3 5.2 LSI 軟件 RAID 設置程序...................................................................... 5-5 5.3 Intel® Rapid Storage Technology enterprise SATA Option ROM 工具程序...................................................................................... 5-25 5.4 Intel® Rapid Storage Technology enterprise 工具程序 (Windows)..........................................................................
5.1 RAID 功能設置 本服務器主板支持以下 RAID 設置: 本主板可支持以下 SATA RAID 方案: • LSI MegaRAID 軟件 RAID 設置程序支持 RAID 0、RAID 1 與 RAID 10 (適用於 Linux 與 Windows)。 • Intel Rapid Storage Technology enterprise / SATA Option ROM Utility 技術支持 RAID 0、RAID 1、RAID 10 與 RAID 5 (僅適用於 Windows)。 5.1.
5.1.2 安裝硬盤 本主板支持 Serial ATA 硬盤。為了最佳的性能表現,當您要建立陣列模 式設置時,請盡可能採用具備相同型號與容量的硬盤。 請依照以下安裝方式來建構 SATA RAID 磁盤陣列: 1. 按照說明將 SATA 硬盤安裝至硬盤槽中。 2. 將 SATA 信號線連接到 SATA 硬盤背部的信號線接口。 3. 將 SATA 電源線連接到 SATA 硬盤背部的電源接口。 5.1.3 設置 BIOS 中的 RAID 選項 在開始建立 R AI D 陣列前,您必須先在 B I O S 程序中對連接到由 I nte l ® C602 芯片組支持的 SATA 接口的 SATA 硬盤進行 RAID 設置。請依照下列 步驟進行操作︰ 1. 在開機自檢(POST)過程中進入 BIOS 設置界面。 2. 進入高級菜單(Advanced)後,選擇 SATA Configuration 選項,然後 按 。 3. 將 SATA Mode 項目設置為 [RAID Mode]。 4.
5.2 LSI 軟件 RAID 設置程序 LSI MegaRAID 軟件設置程序可以提供您創建 RAID 0、RAID 1 或 RAID 10 設置,通過主板上內置的南橋芯片所連接的 SATA 硬盤來創建。 請依照以下的步驟來進入 LSI MegaRAID 軟件設置程序: 1. 安裝所有 SATA 硬盤後啟動系統。 2. 在開機自檢過程中,LSI MegaRAID 軟件設置程序會自動偵測到安裝的 SATA 硬盤並顯示已存在的 RAID 磁盤陣列。按下 + 進入應 用程序。 LSI MegaRAID Software RAID BIOS Version A.
菜單 Configure Initialize Objects Rebuild Check Consistency 說明 本選項提供您以簡易快速的方式或設置新的命令來創建 RAID 0,RAID 1 或 RAID 10 設置。這個選項也可以 讓您查看、增加或刪除 RAID 的設置,或是選擇啟動的 硬盤設備。 允許您初始化已創建 RAID 設置的虛擬磁盤。 允許您初始化邏輯磁盤或更改虛擬磁盤的參數。 允許您重建失效的磁盤 提供您檢查已創建 RAID 設置的虛擬磁盤的數據一致 性。 5.2.
2. 在“ARRAYSELECTION MENU”畫面中,顯示目前連接且可用的SATA 硬盤有多少部。選擇您要進行設置 RAID 的硬盤,然後按下空格鍵。當 選擇時,硬盤指示會從 READY 更改成 ONLIN A[X] - [Y],而 X 所代表 的是 Array 數字,且 Y 表示硬盤設備的數字代號。 LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Management Menu Configure Initialize Objects Rebuild Check Consistency Easy Configuration - ARRAY SELECTION MENU PORT # 0 ONLIN A00-00 1 ONLIN A00-01 2 READY 3 READY Port # 2 DISK 74.74GB HDS728080PLA380 05.
5. 再按 <F10> 鍵,出現虛擬硬盤信息,包括“Virtual Drive”菜單。 您可設置虛擬硬盤參數。 LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Virtual VersionDrive(s) A.10.09231523R Configured LD RAID Size #Stripes StripSzMENU Status Easy Configuration - ARRAY SELECTION Management 0 Menu 1 148.
8. 選擇“Virtual Drive”菜單中的 Units 項目,然後按下 。 9. 在菜單中將 virtual drive 大小設置為 units,然後按下 <Enter>。 LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Virtual VersionDrive(s) A.10.09231523R Configured LD RAID Size #Stripes StripSzMENU Status Easy Configuration - ARRAY SELECTION Management 0 Menu 1 148.
12. 完成對選定虛擬磁盤的設置後,從菜單中選擇【A c c e p t】,然後按下 <Enter> 鍵。 LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Virtual VersionDrive(s) A.10.09231523R Configured LD RAID Size #Stripes StripSzMENU Status Easy Configuration - ARRAY SELECTION Management 0 Menu 1 148.
使用 New Configuration 設置 當一個 RAID 設置已經存在了,使用 New Configuration 命令來 清除存在的 RAID 設置數據。若您不要刪除已存在的 RAID 設置, 使用 View/Add Configuration 選項來查看或創建其他的 RAID 設 置。 請依照以下的步驟,使用 New Configuration (增加設置)模式來創建 一個 RAID 設置: 1. 在“Management Menu”中,選擇【Configure】選項,使用方向鍵來 選擇【New Configuration】項目,然後按下 <Enter> 鍵。 LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
5.2.2 增加或查看一個 RAID 設置 您可以使用 View/Add Configuration 功能來增加一個新的 RAID 或者是 查看一個現存的 RAID 設置。 增加一個 RAID 設置 請依照以下的步驟,來增加一個 RAID 設置: 1. 在“Management Menu”中,選擇【Configure】選項,再選擇【View/ Add Configuration】項目,然後按下 <Enter> 鍵。 LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
5.2.3 將虛擬盤初始化 當您完成創建 RAID 設置時,您必須將虛擬磁盤做初始化。您可以通過 Management Menu 中的 Initialize 或 Objects 選項,來進行虛擬磁盤初始化 的動作。 使用 Initialize 命令設置 請依照以下的步驟,來使用 Initialize(初始化)功能: 1. 進入“M a n a g e m e n t M e n u”後,選擇【I n i t i alize】選項,然後按下 <Enter> 鍵。 LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Management Menu Configure Initialize Objects Rebuild Check Consistency Initialize VD(s) Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2.
3. 按下 鍵來初始化硬盤設備。此時出現詢問框,選擇 [Yes],然後 按下 <Enter>。 LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Management Menu Configure Initialize Objects Rebuild Check Consistency Virtual Drives LD 0 RAID 1 Virtual Drive(s) Configured Size #Stripes StripSz 148.580GB 2 64 KB Status ONLINE Initialize? Yes No Virtual Drive 0 Init Will Destroy Data On Selected VD(s) SPACE-(De)Select, F10-Initialize 初始化硬盤設備的動作,將會清除所有硬盤內的數據。 4.
使用 Objects 命令設置 請依照以下的步驟,來使用 Objects 功能: 1. 在“Management Menu”中,選擇【Objects】選項中的【Virtual Drive】,然後按下 <Enter> 鍵。 LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Objects Management Menu Adapter Configure Virtual Drive Initialize Physical Drive Objects Rebuild Check Consistency Change VD Parameters Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2.
3. 從彈出子菜單中選擇【Initialize】選項,然後按下 <Enter> 鍵開始進行 硬盤初始化。 LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Vitual Drive(1) Virtual Drive 0 Objects Management Menu Adapter Configure Virtual Drive Initialize Physical Drive Objects Vitual Drive(0) Rebuild Initialze Check Consistency Check Consistency View/Update Parameters Initilize VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 4.
5.2.4 重新創建失效的硬盤 您可以採用手動的方式重新創建損壞的硬盤設備,通過使用主畫面中的 Rebuild 命令來達成。 請依照以下的步驟來重新創建失效的硬盤: 1. 進入“M a n a g e m e n t M e n u”後,選擇【R e b u i l d】選項,然後按下 <Enter> 鍵。 LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Management Menu Configure Initialize Objects Rebuild Check Consistency Rebuild PD(s) Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2.
3. 當選擇欲重新創建的硬盤之後並按下 鍵,所選擇的硬盤設備則會 顯示 RBLD 的指示。當出現對話框時,請按下 <Y> 來重新創建硬盤 設備。 LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R REBUILD - PHYSICAL DRIVES SELECTION MENU Management Menu PORT # Configure 0 ONLIN A00-00 Initialize Objects 1 RBLD A00-01 Rebuild Check Consistency Rebuilding Of Drive Will Take A Few Minutes.
5.2.5 檢查硬盤數據的一致性 您可以檢查與核對所選擇硬盤設備裡的數據一致性的正確性。這個工具 程序自動檢測與或採自動檢測與正確的數據任何差異,選擇【Objects】> 【Adapter】選項來進行。 Check Consistency(一致性檢查)命令可用在包含 RAID 1 或 RAID 10 設置下的虛擬磁盤。 使用 Check Consistency 命令設置 請依照以下步驟,使用 Check Consistency 命令檢查數據的一致性: 1. 在“Management Menu”中,選擇【Check Consistency】選項,然後 按下 <Enter> 鍵。 LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
3. 當出現提示時,按下空格鍵來從“Consistency Check”的對話框中選擇 [Yes],然後按下 <Enter> 鍵。 LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Management Menu Configure Initialize Objects Rebuild Check Consistency Virtual Drives Virtual Drive 0 LD 0 Virtual Drive(s) Configured RAID Size #Stripes StripSz 10 154494MB 4 64 KB Yes No Status ONLINE Consistency Check? Select VD SPACE-(De)Select, F10-Check Consistency 這時會出現進行中的完成百分比畫面。 LSI Software RAID Configuration Utility Ver C.
使用 Objets 命令 請依照以下的步驟,使用 Objets 命令檢查數據的一致性: 1. 在“Management Menu”中,選擇“Objets”中的【Virtual Drive】選 項。 2. 使用方向鍵來選擇您所要檢查的虛擬磁盤,然後按 <Enter> 鍵。 3. 從子菜單中,選擇【Check Consistency】,然後按下 <Enter> 鍵。 4. 當出現對話框時,按下 [Yes] 來開始進行檢查硬盤。 5.
5.2.6 刪除一個 RAID 設置 您可以依照以下的步驟,來刪除一個 RAID 設置: 1. 在“M a n a g e m e n t M e n u”中,選擇【C o n f i g u r e】>【C l e a r Configuration】,然後按 <Enter> 鍵。 LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
5.2.7 從 RAID 設置中選擇啟動磁盤 在您要設置選擇啟動磁盤前,您必須已經創建好一個新的 RAID 設置。請 參考“5.2.1 創建 RAID 陣列”的說明。 您可以依照以下的步驟,來選擇啟動磁盤: 1. 進入“Management Menu”後選擇【Configure】>【Select Boot Drive】,然後按 <Enter> 鍵。 LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
5.2.8 開啟 WriteCache 您可以開啟 RAID 控制功能的 WriteCache 選項,來增加數據傳輸性能。 當您開啟 WriteCache 功能時,您可能會在當一個電源間歇發生 在硬盤間傳輸或交換過程時,遺失文件。 設置 RAID 1 與 RAID 10 時建議使用 WriteCache 功能。 您可以依照以下的步驟,來啟用 WriteCache 功能: 1. 進入“Management Menu”後,選擇【Objects】>【Adapter】,然後 按下 <Enter> 鍵顯示改寫的特性。 2. 選擇【Disk WC】,然後按下 <Enter> 鍵來開啟選項。 LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
5.3 Intel ® Rapid Storage Technology enterprise SATA Option ROM 工具 程序 Intel® Rapid Storage Technology enterprise SATA Option ROM 工具程 序通過南橋芯片的支持,可讓您使用連接到主板上 Serial ATA 接口上的 Serial ATA 硬盤創建 RAID 0、RAID 1、RAID 10(RAID 1+0) 與 RAID 5 的陣列設置。 使用內置 SATA 端口: 1. 安裝 Serial ATA 硬盤。 2. 開啟系統。在開機自檢(POST)過程中,按下 進入 BIOS。然後 點擊 Advanced Menu > PCH SATA Configuration > SATA Mode,按 下 。 3. 將 SATA Mode 項目設為 RAID Mode,然後保存並重新啟動系統。 4.
請依照以下步驟進入 Intel® Rapid Storage Technology enterprise SATA Option ROM 應用程序: 1. 安裝所有的 Serial ATA 硬盤。 2. 開啟系統。 3. 在開機自檢(POST)過程中,按下 + 進入程序主菜單。 Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.0.0.1104 Copyright(C) 2003-11 Intel Corporation. All Rights Reserved. 1. Create RAID Volume 2. Delete RAID Volume RAID Volumes: None defined. Physical Disks: ID Drive Model 0 ST3300656SS 1 ST3300656SS 2 ST3300656SS 3 ST3300656SS [↑↓]-Select [ MAIN MENU ] 3.
5.3.1 創建 RAID 陣列 請依照以下步驟創建 RAID: 1. 從程序主菜單中,選擇 1. Create RAID Volume,然後按下 。此 時將出現以下畫面。 Intel(R) Rapid Storage Technology - Option ROM - 10.1.0.1008 Copyright(C) 2003-10 Intel Corporation. All Rights Reserved. [ CREATE VOLUME MENU ] Name: RAID Level: Disks: Strip Size: Capacity: Sync: Volume0 RAID0(Stripe) Select Disks 128KB 0.0 GB N/A Create Volume [ HELP ] Enter a unique volume name that has no special characters and is 16 characters or less.
6. 使用向上、向下方向鍵來選擇 RAID 0 磁盤陣列要分割的容量(僅 RAID 0、RAID 10、RAID 5),然後按下 按鍵。分割的數值可 由 4KB 遞增至 128KB。數值為: RAID 0: 128KB RAID 10: 64KB RAID 5: 64KB 若此系統欲作為服務器使用,建議您選擇較低的磁區大小;若此 系統欲作為多媒體電腦用來運行影音的編輯製作,建議您選擇較 高的磁區大小來獲得最佳的性能。 7. 選擇 Capacity 項目,輸入您所要的陣列容量,接著按下 按鍵。 本項目默認值是採用最高可容許的磁盤容量。 8. 在 Create Volume 的提示對話框中再按下 按鍵來建立磁盤陣列, 接著便會出現如下圖的警示窗口畫面。 WARNING: ALL DATA ON SELECTED DISKS WILL BE LOST. Are you sure you want to create this volume? (Y/N): 9.
2. 為您的修復磁區鍵入一個名稱,然後按下 <Enter> 按鍵。 3. 當 RAID Level 項目高亮時,按上/下鍵頭選擇 Recovery,然後按下 。 4. 當 Disk 選項高亮時,請按下 鍵以選擇要包含在修復設置中的硬 盤設備。接著如下圖所示的畫面便會出現。 Port 0 1 2 3 Drive Model ST3160812AS ST3160812AS ST3160812AS ST3160812AS [ SELECT DISKS ] Serial # 9LS0HJA4 9LS0F4HL 3LS0JYL8 9LS0BJ5H Size 149.0GB 149.0GB 149.0GB 149.0GB Status Non-RAID Non-RAID Non-RAID Non-RAID Disk Disk Disk Disk Select 1 Master and 1 Recovery disk to create volume.
5.3.3 刪除 RAID 磁區 在操作此功能時請務必非常小心,所有在硬盤中的數據將被一併 刪除。 請依照以下步驟刪除磁區: 1. 從程序主菜單中,選擇 2. Delete RAID Volume,然後按下 。此 時將出現以下畫面。 Intel(R) Rapid Storage Technology - Option ROM - 10.1.0.1008 Copyright(C) 2003-10 Intel Corporation. All Rights Reserved. Name Volume0 [ DELETE VOLUME MENU ] Level RAID0(Stripe) Drives 2 Capacity 298.0GB Status Normal Bootable Yes [ HELP ] Deleting a volume will reset the disks to non-RAID. WARNING: ALL DISK DATA WILL BE DELETED.
5.3.4 重新設置硬盤為非陣列硬盤 請注意!當您將 RAID 陣列硬盤設置為無 RAID 陣列狀態時,所 有磁盤陣列中的數據與陣列本身的結構數據都將被去除。 請依照以下步驟重新設置非陣列硬盤: 1. 從程序主菜單中,選擇 3. Reset Disks to Non-RAID,然後按下 。 此時將出現以下畫面。 [ RESET RAID DATA ] Resetting RAID disk will remove its RAID structures and revert it to a non-RAID disk. WARNING: Resetting a disk causes all data on the disk to be lost. (This does not apply to Recovery volumes) Port Drive Model Serial # Size Status 0 ST3160812AS 9LS0HJA4 149.0GB Member Disk 1 ST3160812AS 9LS0F4HL 149.
5.3.5 退出 Intel® Rapid Storage Technology 請依照以下步驟退出程序: 1. 從程序主菜單中,選擇 4. Exit 然後按下 。此時將出現以下畫 面。 [ CONFIRM EXIT ] Are you sure you want to exit? (Y/N): 2. 按下 退出,或按下 回到程序主菜單。 5.3.6 重建 RAID 本選項僅適用於 RAID 1 陣列。 使用未設置 RAID 的硬盤重建 RAID 陣列 若任何包含 RAID 1 陣列的 SATA 硬盤失敗,系統在 POST 過程中顯示 RAID volume 的狀態為“Degraded”。您可使用其他沒有設置 RAID 的硬盤 重建 RAID 陣列。 請依照以下步驟使用未設置 RAID 的硬盤重建 RAID 陣列: 1. 提示出現時,按下 + 進入 Intel Rapid Storage Technology 工具 程序。 2.
3. 選擇硬盤後程序自動開始重建。RAID volume 的狀態變為“Rebuild”。 Intel(R) Rapid Storage Technology - Option ROM - 10.1.0.1008 Copyright(C) 2003-10 Intel Corporation. All Rights Reserved. 1. Create RAID Volume 2. Delete RAID Volume [ MAIN MENU ] 5. Exit 3. Reset Disks to Non-RAID 4.
5.3.7 設置 BIOS 設置程序中的啟動陣列 當使用 Intel® Rapid Storage Technology 創建 multi-RAID 時,您可以為 RAID 陣列設置 BIOS 中的啟動優先級。 請依據以下步驟設置啟動陣列: 請設置至少一個啟動陣列。 1. 重啟系統並在 POST 過程中按下 進入 BIOS。 2. 點擊 Boot 菜單,選擇 Boot Device Priority 項目。 3. 使用上/下方向鍵選擇啟動優先級,然後按下 。更多信息請參 考“ 4.7.1 啟動設備順序 ”。 4. 在 Exit 菜單中選擇 Save Changes & Exit,然後按下 。 5.
5.4 Intel ® Rapid Storage Technology enterprise 工具程序 (Windows) Intel® Rapid Storage Technology enterprise 工具程序通過南橋芯片的支 持,可讓您使用連接到主板上 Serial ATA 接口上的 Serial ATA 硬盤創建 RAID 0、RAID 1、RAID 10(RAID 1+0) 與 RAID 5 的陣列設置。 使用 Intel® Rapid Storage Technology enterprise 工具程序前,請先變更 BIOS 設置: 1. 開機自檢時進入 BIOS。 2. 進入【Advanced】>【Chipset Configuration】>【PCH Configuration】 >【Onboard SATA Oprom】,然後按下 。 3. 將【Onboard SATA Oprom】設為 [Enabled]。 4.
5.4.1 創建 RAID 陣列 請依照以下步驟創建 RAID: 1. 從程序主菜單中,選擇 Create Volume,並選擇卷類型。 2. 點擊 Next。 3. 為您的 RAID 磁區鍵入一個名稱,然後選擇陣列磁盤。 4. 選擇 Volume Size 標籤頁,您可以拖曳滑塊調整卷容量。 5.
6.
5.4.2 更改卷類型 創建 RAID 陣列完成後,您可以在 Volume Properties 區域查看相關項目 的設置。 按照以下步驟更改卷類型: 1. 在 Volume 區域點擊您要更改的 SAS / SATA 陣列項目。 2 在 Volume Properties 區域選擇 Type:RAID 1 Change type。 3. 您可以更改名稱,選擇新卷類型,若有必要還可以選擇要包含到新卷中 的磁盤。 4.
5.4.3 刪除卷 刪除卷時請注意。硬盤上的數據將會丟失,請先備份數據。 按照以下步驟刪除卷: 1. 從 程 序 主 菜 單 中 , 在 V o l u m e 區 域 選 擇 您 要 刪 除 的 卷 ( 如 Volume_0000)。 2. 在 Volume Properties 區域選擇 Delete volume,出現以下畫面。 3.
5.4.
在本章節中,我們將介紹主板所支持 的相關驅動程序的安裝與設置說明。 6 第六章:安裝 驅動程序
6 章節提綱 6.1 安裝 RAID 驅動程序.............................................................................. 6-3 6.2 安裝 Intel 芯片組軟件......................................................................... 6-16 6.3 安裝網卡驅動程序................................................................................ 6-19 6.4 安裝顯卡驅動程序................................................................................ 6-22 6.5 安裝 Intel® C600 MEI NULL HECI 驅動程序........................... 6-24 6.
6.1 安裝 RAID 驅動程序 當您在系統中創建好 RAID 陣列模式後,現在您就可以開始安裝操作系統 至獨立的硬盤設備或具開機功能的磁盤陣列。這章節將來介紹在安裝操作系 統的過程中如何安裝 RAID 控制器的驅動。 6.1.1 創建一張 RAID 驅動程序軟盤 本系統不含軟驅。當您創建 RAID 驅動程序軟盤時需要使用 USB 軟驅。 若您使用 LSI 軟件 RAID 設置程序創建 RAID 陣列,您必須手動 調節 SATA 光驅的啟動順序。否則,系統將不會從連接的 SATA 光驅中啟動。 當您在進行 Windows® 或 Red Hat® Enterprise 操作系統安裝時,必須使 用一張 RAID 驅動程序軟盤,來指定所使用的陣列模式。您可以在 DOS 模 式下,創建 RAID 驅動程序軟盤(使用應用程序光盤中的 Makedisk 工具程 序進行製作)。 在 DOS 環境下,創建一張含有 RAID 驅動程序的軟盤: 1. 在光驅中放入本主板的驅動程序及應用程序光盤。 2. 重新開啟電腦,然後進入 BIOS 設置畫面。 3.
LSI 2008 SAS2 驅動程序 LSI 2008 SAS2 Driver Windows XP 32 bit Windows XP 64 bit Windows Server 2003 32 bit Windows Server 2003 64 bit Windows Vista 32 bit Windows Vista 64 bit Windows Server 2008 32 bit Windows Server 2008 64 bit Windows 7 32 bit Windows 7 64 bit Windows Server 2008 R2 64 bit RHEL 4 UP7 32 bit RHEL 4 UP7 64 bit RHEL 4 UP8 32 bit RHEL 4 UP8 64 bit Back Exit 6. 找到 RAID 驅動程序並將一張高密度空白軟盤放入軟驅。 7. 按下 。 8.
在 Windows® 中創建 RAID 驅動程序軟盤: 1. 打開 Windows 操作系統。 2. 將主板應用程序光盤放入光驅。 3. 進入“Make Disk”菜單,選擇想要創建的 RAID 驅動程序軟盤的類型。 4. 將軟盤插入軟驅。 5. 按照屏幕指示完成操作。 寫入保護軟驅免受電腦病毒的侵害。 在 Red Hat® Enterprise Linux 服務器中創建 RAID 驅動程序軟盤: 1. 將一張空白格式化的高密度軟盤插入 USB 軟驅中。 2. 輸入 dd if=XXX.img of=/dev/fd0 在驅動程序與應用程序光盤中, 由以下路徑將文件減壓縮至軟盤: LSI MegaRAID 驅動程序: \Drivers\C600 LSI RAID\Driver\makedisk\Linux 3.
6.1.2 安裝 RAID 控制器驅動程序 在 Windows® Server 2008 操作系統安裝過程中 請依照以下步驟在 Windows ® Server 2008 操作系統安裝過程中安裝 RAID 控制器驅動程序: 1. 用 Windows® 服務器操作系統安裝光盤啟動系統。依據屏幕指示完成安 裝。 2. 在安裝類型中選擇“Custom(Advanced)”。 3.
4. 出現一條信息,提示您插入包含 RAID 控制器驅動程序的安裝媒體。若您 的系統中只有光驅,先退出 Windows 操作系統安裝盤,然後放入主板驅 動程序與應用程序光盤,點擊 Browse 繼續。 5. 找到光盤中的驅動程序,點擊 OK 繼續。 6. 從列表中選擇您需要的 RAID 控制器驅動程序,點擊 Next。 7. 當系統加載完成 RAID 驅動程序後,將驅動程序與應用程序光盤拿出,重 新放入操作系統安裝盤。選擇安裝系統的磁盤,點擊 Next。 8.
Red Hat® Enterprise Linux 5.6 操作系統 在 Red Hat® Enterprise 操作系統安裝時安裝 RAID 控制器驅動程序: 1. 使用 Red Hat® 操作系統安裝光盤啟動系統。 2. 在【Boot:】後輸入 linux dd noprobe=ata1 noprobe=ata2..., 然後按下 鍵。 ata 的數量依據創建 RAID 設置時的硬盤數量決定。例如, 若您要創建包含 6 塊硬盤的 RAID 設置,在命令行中輸入: linux dd noprobe=ata1 noprobe=ata2 noprobe=ata3 noprobe=ata4 noprobe=ata5 noprobe=ata6。 - To install or upgrade in graphical mode, press the key. - To install or upgrade in text mode, type: linux text .
5. 選擇【No】並按下 鍵繼續。 More Driver Disks? Do you wish to load any more driver disks? Yes No 6. 按照屏幕提示完成 RedHat 操作系統安裝。 7. 安裝完成後,請勿點擊重新啟動。按下 + + 切換命令 行界面至圖形用戶界面。 8. 若使用 Legacy 軟驅,輸入以下指令: mkdir /mnt/driver mount /dev/fd0 /mnt/driver cd /mnt/driver sh replace_ahci.
Red Hat® Enterprise Linux OS 6.1 操作系統 在 Red Hat® Enterprise 操作系統安裝時安裝 LSI MegaRAID 控制器驅動 程序: 1. 使用 Red Hat® 操作系統安裝光盤啟動系統。 2. 按下 編輯選項。 3.
4. 當系統詢問您是否有驅動程序軟盤時,請按 鍵選擇【Yes】,然 後按下 鍵繼續。 Main Menu Do you have a driver disk? Yes No 5. 您有多個設備可作為驅動程序磁盤來源,選擇您要使用的磁盤並選擇【 OK】,然後按下 。 Driver Disk Sou8rce You have multiple devices which could serve as source for a driver disk.
6. 將 Red Hat® Enterprise RAID 驅動光盤插入 USB 軟驅,選擇【OK】, 然後按下 。 Insert Driver Disk Insert your driver disk into /dev/sdb and press “OK” to continue. OK Back RAID 卡驅動程序已安裝至系統 7. 當詢問您是否加載其他 R A I D 控制器驅動程序時,選擇【No】並按下 鍵繼續。 More Driver Disks? Do you wish to load any more driver disks? Yes No 8.
安裝 Linux 驅動程序 請使用另一台安裝了 Linux 操作系統的電腦來創建 RAID 驅動程序。創建 RAID 驅動程序時,您需要參閱以下示例來使用 64-bit SUSE Linux 操作系 統為 SUSE11 sp1 創建 64-bit RAID 驅動程序。 1. 將鏡像文件復製到 Linux 操作系統。 如:megasr-15.00.0120.2012-1-slesll-ga-x86_64.img 2. 新建一個文件夾。 如:image 3. 通過以下命令格式安裝鏡像文件至 image 文件夾: mount -o loop [image file name] image 如:mount -o loop megasr-15.00.0120.2012-1-slesllga-x86_64.img image 4. 將 image 目錄下的命名為“01”的內容復製到一個 FAT32 格式的 USB 設備。 5.
安裝 SUSE Linux 11 操作系統 請依照以下的步驟,在 SUSE Linux Enterprise Server 操作系統安裝過程 中安裝 LSI MegaRAID 驅動程序: 1. 使用 SUSE 操作系統安裝光盤啟動系統。 2. 在【Boot Options】(啟動選項)菜單中,用方向鍵選擇【Installation】 (安裝)。 3.
4. 在操作系統安裝過程中使用 USB 盤提供第三方驅動程序。在 [Boot Options](啟動選項)後輸入命令行:brokenmodules=ahci,然後按 下 鍵。 5. 當以下畫面出現時,選擇 USB 軟驅(sda)作為驅動程序升級媒介。選 擇【OK】,然後按下 鍵。 Please choose the Driver Update medium. sda: USB Floppy Other device OK Back 6.
6.2 安裝 Intel 芯片組軟件 本章節將介紹如何為系統中的 Intel® 芯片組安裝即插即用組件。 在 Windows 操作系統下,您需要手動安裝 Intel® 芯片組軟件。 1. 重新開機,使用 Administrator(管理員)權限登錄 Windows 系統。 2. 於光驅中放入主板/系統所附的應用程序與驅動程序光盤,若您的系統 已經啟動了光驅“自動播放”的功能,那麼稍後一會光盤會自動顯示 Drivers 菜單(驅動程序菜單)窗口。 若您的系統未啟動光驅“自動播放”的功能,請瀏覽光盤的文 件內容,在 BIN 文件夾里找到 ASSETUP.EXE 文件,並雙擊 ASSETUP.EXE 運行隨機光盤。 3. 從菜單中點擊“Intel(R) Chipset Device Software”項目。 4.
5. 選擇【Yes】接受許可同意條款,並且繼續安裝進程。 6. 閱讀文檔的信息並且按下【Next】鍵繼續安裝。 7.
8.
6.3 安裝 Intel® 網卡驅動程序 本章節將介紹如何在 Windows® 服務器操作系統中安裝 Intel® 網絡控制 器驅動程序。 請依照以下的步驟安裝網卡控制驅動程序: 1. 重新開機,使用 Administrator(管理員)權限登錄 Windows 系統。 2. 於光驅中放入主板/系統所附的應用程序與驅動程序光盤,若您的系統 已經啟動了光驅“自動播放”的功能,那麼稍後一會光盤會自動顯示 Drivers 菜單(驅動程序菜單)窗口。 • Windows ® 會自動偵測 LAN 控制器並顯示窗口。點擊【取 消】關閉窗口。 • 若您的系統未啟動光驅“自動播放”的功能,請瀏覽光盤的 文件內容,在 BIN 文件夾里找到 ASSETUP.EXE 文件,並雙 擊 ASSETUP.EXE 運行隨機光盤。 3. 點擊【Intel® Network Connections Software】開始安裝。 4.
5. 當 Intel(R) 網絡連接–InstallShield Wizard 窗口出現時,點擊【Next】。 6. 勾選“ I accept the terms in the license agreement”,然後點擊 【Next】繼續。 7.
8. 按照畫面指示完成安裝。 9.
6.4 安裝顯卡驅動程序 本章節將介紹如何安裝 ASPEED 顯示驅動程序。 您需要在 Windows® 操作系統中手動安裝 ASPEED 顯示驅動程序。 1. 重新開機,使用 Administrator(管理員)權限登錄 Windows 系統。 2. 於光驅中放入主板 / 系統所附的應用程序與驅動程序光盤,若您的系 統已經啟動了光驅“自動播放”的功能,那麼稍後一會光盤會自動顯示 Drivers 菜單(驅動程序菜單)窗口。 若您的系統未啟動光驅“自動播放”的功能,請瀏覽光盤的文 件內容,在 BIN 文件夾里找到 ASSETUP.EXE 文件,並雙擊 ASSETUP.EXE 運行隨機光盤。 3. 點擊【ASPEED AST2300 / AST1300 Display Driver】項目。 4.
5. 點擊【Install】開始安裝。 6.
6.5 安裝 C600 MEI NULL HECI 驅動程 序 本章節將介紹如何安裝 C600 MEI NULL HECI 驅動程序。 您需要在 Windows® 操作系統中手動安裝 Intel® C600 MEI NULL HECI 驅動程序。 按照以下步驟安裝: 1. 重新開機,使用 Administrator(管理員)權限登錄 Windows 系統。 2. 於光驅中放入主板 / 系統所附的應用程序與驅動程序光盤,若您的系 統已經啟動了光驅“自動播放”的功能,那麼稍後一會光盤會自動顯示 Drivers 菜單(驅動程序菜單)窗口。 若您的系統未啟動光驅“自動播放”的功能,請瀏覽光盤的文 件內容,在 BIN 文件夾里找到 ASSETUP.EXE 文件,並雙擊 ASSETUP.EXE 運行隨機光盤。 3.
6.6 安裝 Intel® Rapid Storage Technology enterprise 3.1 本章節將介紹如何安裝 Intel ® Rapid Storage Technology enterprise 3.1。 您需要在 W i n d o w s ® 操作系統中手動安裝 I n t e l ® R a p i d S t o r a g e Technology enterprise 3.1 應用程序。 按照以下步驟安裝 Intel® Rapid Storage Technology enterprise 3.1 應用 程序: 1. 重新開機,使用 Administrator(管理員)權限登錄 Windows 系統。 2. 於光驅中放入主板 / 系統所附的應用程序與驅動程序光盤,若您的系 統已經啟動了光驅“自動播放”的功能,那麼稍後一會光盤會自動顯示 Drivers 菜單(驅動程序菜單)窗口。 若您的系統未啟動光驅“自動播放”的功能,請瀏覽光盤的文 件內容,在 BIN 文件夾里找到 ASSETUP.EXE 文件,並雙擊 ASSETUP.EXE 運行隨機光盤。 3.
5. 閱讀警告信息,點擊【Next】繼續。 6. 選擇【Yes】接受許可同意條款,並且繼續安裝進程。 7.
8. 安裝完成後,點擊【Next】完成設置過程。 9.
6.7 安裝 Asmedia ASM104x USB 3.0 主機控制器驅動程序 本章節將介紹如何安裝 Asmedia ASM104x USB 3.0 主機控制器驅動程 序。 按照以下步驟安裝: 1. 重新開機,使用 Administrator(管理員)權限登錄 Windows 系統。 2. 於光驅中放入主板 / 系統所附的應用程序與驅動程序光盤,若您的系 統已經啟動了光驅“自動播放”的功能,那麼稍後一會光盤會自動顯示 Drivers 菜單(驅動程序菜單)窗口。 若您的系統未啟動光驅“自動播放”的功能,請瀏覽光盤的文件 內容,找到 AUTORUN.EXE 文件,並雙擊 AUTORUN.EXE 運行 隨機光盤,然後按照步驟 4 進行安裝。 3. 點擊【Asmedia ASM104x USB 3.
4. 當 Asmedia ASM104x USB 3.0 主機控制器驅動程序安裝嚮導出現後, 點擊【Next】開始安裝。 5.
6.
6.8 安裝 Intel ® WG82574L 千兆網卡驅 動程序 本章節將介紹如何在 W i n d o w s ® 服務器操作系統中安裝 I n t e l ® WG82574L 千兆網絡控制器驅動程序。 按照以下步驟安裝 Intel® WG82574L 千兆網絡控制器驅動程序: 1. 重新開機,使用 Administrator(管理員)權限登錄 Windows 系統。 2. 於光驅中放入主板/系統所附的應用程序與驅動程序光盤,若您的系統 已經啟動了光驅“自動播放”的功能,那麼稍後一會光盤會自動顯示 Drivers 菜單(驅動程序菜單)窗口。 若您的系統未啟動光驅“自動播放”的功能,請瀏覽光盤的文件 內容,找到 AUTORUN.EXE 文件,並雙擊 AUTORUN.EXE 運行 隨機光盤,然後按照步驟 4 進行安裝。 3.
4. 當 Intel(R) PRO Network Connections–InstallShield Wizard 窗口出現時, 點擊【Next】開始安裝。 5.
6. 選擇您要安裝的程序,然後點擊【Next】繼續。 7.
8. 正在安裝程序。 9. 安裝完成后點擊【Finish】完成安裝。 9.
6.9 安裝管理應用與工具程序 在主板所附的應用程序與驅動程序光盤中,包含有驅動程序、管理應用程 序,以及一些工具程序,讓您可以搭配在主板上操作使用。 應用程序與驅動程序光盤中的聯系信息,可能會因為不定時的情 況而有所更動。請參考華碩網頁(www.asus.com.cn)上的信息 來升級至最新的聯系信息。 6.9.1 運行驅動程序與應用程序光盤 將此光盤放入系統的光驅中,然後光驅會自動顯示 Drivers 菜單(驅動程 序)畫面。(若您的系統已經啟動了光驅“自動播放”的功能。) 如果 Drivers 菜單並未自動出現,那麼您也可以應用程序與驅動 程序光盤中的 BIN 文件夾裡面直接點擊 ASSETUP.EXE 主程序 來開啟菜單窗口。 6.9.
6.9.3 工具軟件菜單 應用程序菜單提供了您目前 所需要的工具軟件。請點擊您所 需要的軟件,來進行安裝。 6.9.4 制作磁盤菜單 此菜單中的項目可讓您制作 Intel RAID 驅動磁盤。 6.9.
本章包含安裝主板時可以參考的相 關信息。 A 附錄:相關信息
A 附錄提綱 A.1 Z9PA-D8 架構圖.....................................................................................A-3 A.2 Z9PA-D8C 架構圖.................................................................................
A.
A.