Universal Standard Service, Inc. Report No. ASL23051710 Test Report Applicant : ASUS COMPUTER GmbH Address : HARKORT STR.
Universal Standard Service, Inc. Report No. ASL23051710 TEST REPORT EN 62368-1 Audio/video, information and communication technology equipment Part 1: Safety requirements Report Number. .............................. : ASL23051710 Project Number............................... : ASL23051710 Date of issue ................................... : 2023-10-10 Tested by......................................... : Melendez Yang Approved by ...................................
Universal Standard Service, Inc. Report No. ASL23051710 Other Aspects: Test results given in this report only relate to the specimen(s) tested, calibrated or measured. This report shall not be reproduced other than in full without the written consent of USS. Statement of conformity: The judgment rules of test results based on the judgment requirements of test standard(s), and measurement uncertainties do not be considered.
Universal Standard Service, Inc. Report No. ASL23051710 Summary of testing: The product is intended to be: - Installed on a desktop or other flat surface horizontally; or - Mounted on the wall vertically or horizontally as movable equipment. Maximum normal load: The EUT reads and writes in SSD continuously. Run CPU program until performance to 100%. Each USB port is loaded with 0.9A. Two USB ports (USB2_56) are loaded with 0.5A.
Universal Standard Service, Inc. Report No.
Universal Standard Service, Inc. Report No. ASL23051710 TEST ITEM PARTICULARS: Classification of use by ................................................ : Ordinary person Instructed person Skilled person Children likely to be present Supply Connection ....................................................... : AC Mains DC Mains External Circuit - not Mains connected ES1 ES2 ES3 Supply % Tolerance ....................................................
Universal Standard Service, Inc. Report No. ASL23051710 Mass of equipment (kg) ............................................: Max. 1.84 kg POSSIBLE TEST CASE VERDICTS: - test case does not apply to the test object................. : N/A - test object does meet the requirement ...................... : P (Pass) - test object does not meet the requirement ................ : F (Fail) TESTING: Date of receipt of test item ............................................
Universal Standard Service, Inc. Report No.
Universal Standard Service, Inc. Report No. ASL23051710 ENERGY SOURCE IDENTIFICATION AND CLASSIFICATION TABLE: (Note 1: Identify the following six (6) energy source forms based on the origin of the energy.) (Note 2: The identified classification e.g., ES2, TS1, should be with respect to its ability to cause pain or injury on the body or its ability to ignite a combustible material. Any energy source can be declared Class 3 as a worse case classification e.g. PS3, ES3.
Universal Standard Service, Inc. Report No. ASL23051710 ENERGY SOURCE IDENTIFICATION AND CLASSIFICATION TABLE: Internal Parts/components can be touched TS1 Internal components can not be touched TS3 Radiation (Clause 10) (Note: List the types of radiation present in the product and the corresponding energy source classification.
Universal Standard Service, Inc. Report No. ASL23051710 OVERVIEW OF EMPLOYED SAFEGUARDS Clause Possible Hazard 5.1 Electrically-caused injury Body Part (e.g. Ordinary) Energy Source (ES3: Primary Filter circuit) N/A -- 6.1 Electrically-caused fire Material part (e.g.
Universal Standard Service, Inc. Report No. ASL23051710 (e.g., Ordinary) (Output from audio port) N/A -- Supplementary Information: (1) See attached energy source diagram for additional details.
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test Result - Remark 4 GENERAL REQUIREMENTS P 4.1.1 Acceptance of materials, components and subassemblies P 4.1.2 Use of components P 4.1.3 Equipment design and construction P 4.1.15 Markings and instructions .................................. : 4.4.4 Safeguard robustness 4.4.4.2 Steady force tests .............................................. : 4.4.4.3 Drop tests .................................
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test Result - Remark Verdict 5 ELECTRICALLY-CAUSED INJURY 5.2.1 Electrical energy source classifications .............. : 5.2.2 ES1, ES2 and ES3 limits 5.2.2.2 Steady-state voltage and current ........................ : N/A 5.2.2.3 Capacitance limits................................................ : N/A 5.2.2.4 Single pulse limits ................................................ : N/A 5.2.2.
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test Result - Remark 5.4.1.10.3 Ball pressure ....................................................... : N/A 5.4.2 Clearances N/A 5.4.2.2 Determining clearance using peak working voltage N/A 5.4.2.3 Determining clearance using required withstand voltage ................................................................. : N/A a) a.c. mains transient voltage............................. : ⎯ b) d.c.
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test Result - Remark Verdict 5.4.6 Insulation of internal wire as part of supplementary safeguard........................................................... : N/A 5.4.7 Tests for semiconductor components and for cemented joints N/A 5.4.8 Humidity conditioning N/A Relative humidity (%) ........................................ : ⎯ Temperature (°C) ...............................................
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test Result - Remark 5.5.5 Relays N/A 5.5.6 Resistors N/A 5.5.7 SPD’s N/A 5.5.7.1 Use of an SPD connected to reliable earthing N/A 5.5.7.2 Use of an SPD between mains and protective earth N/A 5.5.8 Insulation between the mains and external circuit consisting of a coaxial cable.............................. : N/A 5.6 Protective conductor N/A 5.6.2 Requirement for protective conductors N/A 5.6.2.
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test Result - Remark Verdict ⎯ Multiple connections to mains (one connection at a time/simultaneous connections) ..........................: 5.7.4 Earthed conductive accessible parts ...................: N/A 5.7.5 Protective conductor current N/A Supply Voltage (V) ..............................................: ⎯ Measured current (mA) .......................................: ⎯ Instructional Safeguard .....
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test for unknown materials ....................................... : Result - Remark 6.3.1 (b) Combustible materials outside fire enclosure Decorative parts and parts outside of the fire enclosure are made of HB min. or Flammability level is ignored, when small parts (4g max. or 1750mm^3 max.) 6.4 Safeguards against fire under single fault conditions 6.4.1 Safeguard Method 6.4.
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test Result - Remark 6.4.8.3.1 Fire enclosure and fire barrier openings P 6.4.8.3.2 Fire barrier dimensions P 6.4.8.3.3 Top Openings in Fire Enclosure: dimensions (mm) Openings do not exceed 5 mm in ................................................................................. : any dimension or 1 mm in width. When antenna connector not installed: Antenna hole is covered by rubber with V-1 minimum material.
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test Result - Remark 8 MECHANICALLY-CAUSED INJURY P 8.1 General P 8.2 Mechanical energy source classifications P 8.3 Safeguards against mechanical energy sources P 8.4 Safeguards against parts with sharp edges and corners N/A 8.4.1 Safeguards N/A 8.5 Safeguards against moving parts N/A 8.5.1 MS2 or MS3 part required to be accessible for the function of the equipment N/A 8.5.
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test Result - Remark Verdict 8.6.5 Horizontal force test (Applied Force) ..................... : N/A Position of feet or movable parts............................ : ⎯ 8.7 Equipment mounted to wall or ceiling P 8.7.1 Mounting Means (Length of screws (mm) and mounting surface) .................................................. : See Enclosure 2-02 to 2-03 for Mounting Bracket dimension in details. P 8.7.
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test Result - Remark 8.10.6 Thermoplastic temperature stability (C) ............... : N/A 8.11 Mounting means for rack mounted equipment N/A 8.11.1 General N/A 8.11.2 Product Classification N/A 8.11.3 Mechanical strength test, variable N .................... : N/A 8.11.4 Mechanical strength test 250N, including end stops N/A 8.12 Telescoping or rod antennas.................................
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test 10.4.1.c) Equipment visible, IR, UV does not exceed RS1 .............................................................................. : N/A 10.4.1.d) Normal, abnormal, single-fault conditions ......... : N/A 10.4.1.e) Enclosure material employed as safeguard is opaque ................................................................. : N/A 10.4.1.f) UV attenuation ........................................
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test input Result - Remark ⎯ Input voltage with 94 dB(A) LAeq acoustic pressure output ................................................... : 10.6.5.2 Corded listening devices with digital input N/A ⎯ Maximum dB(A) .................................................. : 10.6.5.3 Verdict Cordless listening device N/A Maximum dB(A) ..................................................
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test Result - Remark Verdict B.4.4.2 Short circuit of creepage distances for functional insulation B.4.4.3 Short circuit of functional insulation on coated printed boards N/A B.4.5 Short circuit and interruption of electrodes in tubes and semiconductors N/A B.4.6 Short circuit or disconnect of passive components N/A B.4.7 Continuous operation of components N/A B.4.
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test Result - Remark Instructions – Language .....................................: English. Other languages will be provided when submitted for national approval. Verdict ⎯ F.2 Letter symbols and graphical symbols P F.2.1 Letter symbols according to IEC60027-1 P F.2.2 Graphic symbols IEC, ISO or manufacturer specific P F.3 Equipment markings P F.3.1 Equipment marking locations P F.3.
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test Result - Remark F.3.6.2.1 Class II equipment with or without functional earth N/A F.3.6.2.2 Class II equipment with functional earth terminal marking N/A F.3.7 Equipment IP rating marking .............................. : F.3.8 External power supply output marking F.3.9 Durability, legibility and permanence of marking F.3.10 Test for permanence of markings F.
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test Result - Remark Verdict G.2.3 Relay controlling connectors supply power N/A G.2.4 Mains relay, modified as stated in G.2 N/A G.3 Protection Devices G.3.1 Thermal cut-offs N/A G.3.1.1a) &b) Thermal cut-outs separately approved according to IEC 60730 with conditions indicated in a) & b) N/A G.3.1.1c) Thermal cut-outs tested as part of the equipment as indicated in c) N/A G.3.1.
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test Result - Remark Temperature (C) ................................................ : Verdict ⎯ G.5.2.3 Wound Components supplied by mains N/A G.5.3 Transformers N/A G.5.3.1 Requirements applied (IEC61204-7, IEC61558-1/2, and/or IEC62368-1) ......................................... : N/A Position ................................................................ : ⎯ Method of protection .................
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test Result - Remark G.5.4.7 Motors with capacitors N/A G.5.4.8 Three-phase motors N/A G.5.4.9 Series motors N/A Operating voltage ............................................... : Verdict ⎯ G.6 Wire Insulation N/A G.6.1 General N/A G.6.2 Solvent-based enamel wiring insulation N/A G.7 Mains supply cords N/A G.7.1 General requirements N/A Type .................................................
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test Result - Remark Verdict G.8.3.2 Varistor overload test ..........................................: N/A G.8.3.3 Temporary overvoltage .......................................: N/A G.9 Integrated Circuit (IC) Current Limiters G.9.1 a) Manufacturer defines limit at max. 5A. G.9.1 b) Limiters do not have manual operator or reset G.9.1 c) Supply source does not exceed 250 VA ............
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test G.13.4 Insulation between conductors on the same inner surface N/A Compliance with cemented joint requirements (Specify construction) .......................................... : ⎯ G.13.5 Result - Remark Verdict Insulation between conductors on different surfaces N/A Distance through insulation ................................. : N/A Number of insulation layers (pcs) ....................... : ⎯ G.13.
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test Result - Remark D2) Capacitance ........................................................ : ⎯ D3) Resistance .......................................................... : ⎯ H CRITERIA FOR TELEPHONE RINGING SIGNALS N/A H.1 General N/A H.2 Method A N/A H.3 Method B N/A H.3.1 Ringing signal N/A H.3.1.1 Frequency (Hz) ...................................................: ⎯ H.3.1.2 Voltage (V) ..
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test Result - Remark K.7.2 Overload test, Current (A) .................................. : N/A K.7.3 Endurance test N/A K.7.4 Electric strength test .......................................... : N/A L DISCONNECT DEVICES N/A L.1 General requirements N/A L.2 Permanently connected equipment N/A L.3 Parts that remain energized N/A L.4 Single phase equipment N/A L.5 Three-phase equipment N/A L.
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test Result - Remark Verdict M.4.2.2a) Charging voltage, current and temperature ....... : ⎯ M.4.2.2 b) Single faults in charging circuitry........................ : ⎯ M.4.3 Fire Enclosure N/A M.4.4 Endurance of equipment containing a secondary lithium battery N/A M.4.4.2 Preparation N/A M.4.4.3 Drop and charge/discharge function tests N/A Drop N/A Charge N/A Discharge N/A M.4.4.
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test Result - Remark M.9.1 Protection from electrolyte spillage N/A M.9.2 Tray for preventing electrolyte spillage N/A M.10 Instructions to prevent reasonably foreseeable misuse (Determination of compliance: inspection, data review; or abnormal testing) ....................... : N ELECTROCHEMICAL POTENTIALS Complied by inspection and data review. P N/A ⎯ Metal(s) used......................................
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test Result - Remark Verdict P.4.2 b) Abrasion testing ................................................. : N/A P.4.2 c) Mechanical strength testing ................................. : N/A Q CIRCUITS INTENDED FOR INTERCONNECTION WITH BUILDING WIRING P Q.1 Limited power sources P Q.1.1 a) Inherently limited output P Q.1.
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test S.2 Flammability test for fire enclosure and fire barrier integrity N/A Samples, material ............................................... : ⎯ Wall thickness (mm) ............................................ : ⎯ Conditioning (C) ................................................. : ⎯ S.
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1 Clause Requirement + Test Result - Remark Verdict T.8 Stress relief test.................................................. : N/A T.9 Impact Test (glass) N/A T.9.1 General requirements N/A T.9.2 Impact test and compliance N/A Impact energy (J)................................................... : ⎯ Height (m) .............................................................. : ⎯ T.10 Glass fragmentation test ..................
Universal Standard Service, Inc. Report No. ASL23051710 4.1.2 TABLE: List of critical components Object / part No. Manufacturer/ trademark Type / model Power Adapter (Optional) Delta Electronics, Inc. Power Adapter (Optional) (Alternate) P Standard Mark(s) of conformity1 Input: AC 100VDPS-90AB-3 XX, (X=0-9, A-Z 240V~, 2A-1A, 5060Hz; or blank) Output: DC 12Vdc/7.
Universal Standard Service, Inc. Report No. ASL23051710 (Optional) Technology Company, Inc. OS21007, 2.5A or 3A OCP0S3128Q** **********, OCP0S3256Q** **********, OCP0S3512Q** **********, OCP0S31024Q* *********** (*= 0-9, A-Z, a-z, - or blank) 1:2018 Solid State Drives (Optional) (Alternate) Interchangeable Interchangeable DC 5V; 1A or 2A or IEC 609502.5A or 3A max.
Universal Standard Service, Inc. Report No. ASL23051710 CO LTD (KTS) current 10mA - RTC Battery (Alternate) DOUBLE BEST CO LTD (DBV) BR2032 3Vdc, Maximum abnormal charging current 10mA UL 1642 UL (MH46388) - RTC Battery (Alternate) Interchangeable BR2032 3Vdc, maximum abnormal charging current 5mA min., against charging current by multiple components Diode SD1 and Resistor SR14 (1Kohm.) UL 1642 UL - PTC Polyswitch Polytronics (GF4) for HDMI port, Technology (GF1) for Display Corp.
Universal Standard Service, Inc. Report No. ASL23051710 All PCBs Interchangeable Interchangeable V-0 min., 130oC min. UL 796 UL Wall mount brackets Interchangeable (two provided) (Optional) Interchangeable Aluminium -- -- Decoration parts Interchangeable Interchangeable Min. HB, located outside of enclosure. UL 94 UL Decoration parts (Alternate) Interchangeable Interchangeable Flammability level -is ignored, when small parts (4g max. or 1750mm^3 max.) located outside of enclosure.
Universal Standard Service, Inc. Report No. ASL23051710 4.8.4, 4.8.5 TABLE: Lithium coin/button cell batteries mechanical tests N/A (The following mechanical tests are conducted in the sequence noted.) 4.8.4.2 ⎯ TABLE: Stress Relief test Part 4.8.4.3 Material Oven Temperature (°C) ⎯ TABLE: Battery replacement test — Battery part no. .............................................................
Universal Standard Service, Inc. Report No. ASL23051710 4.8.5 TABLE: Lithium coin/button cell batteries mechanical test result Test position Surface tested N/A Force (N) Duration force applied (s) Supplementary information: 5.2 Table: Classification of electrical energy sources N/A 5.2.2.2 – Steady State Voltage and Current conditions No. Location (e.g.
Universal Standard Service, Inc. Report No. ASL23051710 5.2.2.5 - Repetitive Pulses No. Location (e.g. circuit designation) Supply Voltage Parameters Test conditions Off time (ms) Upk (V) Ipk (mA) ES Class Normal Abnormal Single fault – SC/OC Test Conditions: Normal – Abnormal Supplementary information: SC=Short Circuit, OC=Short Circuit 5.4.1.4, 6.3.2, 9.0, B.2.
Universal Standard Service, Inc. Report No. ASL23051710 Ambient 24.8 60.0 24.8 25.0 -- PCB near CPU 65.0 100.2 65.0 65.2 105/104 RTC battery body 54.5 89.7 54.5 54.7 100/80 Memory module body (Plastic) -- -- 64.3 64.5 --/87 2.5” SSD body (Metal) -- -- 52.0 52.2 --/70 M.2 SSD body (Plastic) -- -- 65.0 65.2 --/87 nano SIM card cover (Metal) -- -- 73.6 73.8 -- Wireless card body (Metal) -- -- 65.9 66.1 --/70 LTE module body (Metal) -- -- 70.4 70.
Universal Standard Service, Inc. Report No. ASL23051710 e (TS2) Ambient 24.7 60.0 24.7 25.0 -- PCB near CPU 57.3 92.6 57.3 57.6 105/104 RTC battery body 48.4 83.7 48.4 48.7 100/80 Memory module body (Plastic) -- -- 55.3 55.6 --/87 2.5” SSD body (Metal) -- -- 43.9 44.2 --/70 M.2 SSD body (Plastic) -- -- 57.6 57.9 --/87 nano SIM card cover (Metal) -- -- 65.9 66.2 --/70 Wireless card body (Metal) -- -- 58.9 59.2 --/70 LTE module body (Metal) -- -- 63.9 64.
Universal Standard Service, Inc. Report No. ASL23051710 2.5” SSD body (Metal) -- -- 48.5 -- --/70 M.2 SSD body (Plastic) -- -- 63.7 -- --/87 nano SIM card cover (Metal) -- -- 71.5 -- -- Wireless card body (Metal) -- -- 64.9 -- --/70 LTE module body (Metal) -- -- 67.8 -- --/70 Enclosure outside near CPU (Metal) -- -- 47.6 -- --/70 Enclosure outside near 2.5” SSD (Metal) -- -- 38.
Universal Standard Service, Inc. Report No. ASL23051710 Test condition 2: Maximum normal load 36Vdc (Horizontal), Duration: 2hrs.20mins. Test condition 3: Maximum normal load 36Vdc (Wall mounted, Power button side faced downward), Duration: 1hr.55mins. Test condition 4: Maximum normal load 36Vdc (Wall mounted, Power button side faced to left), Duration: 1hr.32mins. Test condition 5: Maximum normal load 36Vdc (Wall mounted, Power button side faced to right), Duration: 1hr.38mins.
Universal Standard Service, Inc. Report No. ASL23051710 5.4.1.10.3 TABLE: Ball pressure test of thermoplastics N/A Allowed impression diameter (mm) .................................. : 2 mm Object/Part No./Material Manufacturer/trademark ⎯ Test temperature (C) Impression diameter (mm) Supplementary information: 5.4.2.2, 5.4.2.4 and 5.4.3 TABLE: Minimum Clearances/Creepage distance Clearance (cl) and creepage distance (cr) at/of/between: Up (V) U r.m.s.
Universal Standard Service, Inc. Report No. ASL23051710 5.4.4.2, 5.4.4.5 c) 5.4.4.9 TABLE: Distance through insulation measurements Distance through insulation di at/of: Peak voltage (V) Frequency (kHz) N/A Material Required DTI (mm) DTI (mm) Supplementary information: 5.4.9 TABLE: Electric strength tests N/A Voltage shape (AC, DC) Test voltage applied between: Breakdown Yes / No Test voltage (V) Functional: Basic/supplementary: Reinforced: Routine Tests: Supplementary information: 5.5.2.
Universal Standard Service, Inc. Report No. ASL23051710 5.6.6.2 TABLE: Resistance of protective conductors and terminations Accessible part Test current (A) Duration (min) N/A Voltage drop (V) Resistance (Ω) Supplementary information: 5.7.2.2, 5.7.4 TABLE: Earthed accessible conductive part N/A — Supply voltage ............................................................. : Test conditions specified in 6.1 of IEC 60990 or Fault Condition No in IEC 60990 clause 6.2.2.1 through 6.2.2.
Universal Standard Service, Inc. Report No.
Universal Standard Service, Inc. Report No. ASL23051710 classification. A Resistive PIS: (a) dissipates more than 15 W, measured after 30 s of normal operation, or (b) under single fault conditions has either a power exceeding 100 W measured immediately after the introduction of the fault if electronic circuits, regulators or PTC devices are used, or has an available power exceeding 15 W measured 30 s after introduction of the fault.
Universal Standard Service, Inc. Report No. ASL23051710 continuous data transmission. B.3 TABLE: Abnormal operating condition tests P Ambient temperature (C) .............................................................: See below or 25C ⎯ Power source for EUT: Manufacturer, model/type, output rating ..: See appended table 4.1.2 ⎯ Component No. Abnormal Condition Supply voltage, (V) Test time Fuse Fuse T-couple (ms) no. current, (A) Temp.
Universal Standard Service, Inc. Report No. ASL23051710 ASRE. USB (USB2_56), pin1,2 to GND Overload 36Vdc See table 5.4.1.4 -- -- See table 5.4.1.4 USB (USB2_56), pin1,2 to GND Short 36Vdc 30mins. -- -- -- DP (HDMI1_DP1), pin20 to GND Overload 36Vdc See table 5.4.1.4 -- -- See table 5.4.1.4 DP (HDMI1_DP1), pin20 to GND Short 36Vdc 30mins. -- -- -- COM (COM1), pin9 to GND (Jumper on COM1_SEL1, pin(1-2)) Overload 36Vdc See table 5.4.1.4 -- -- See table 5.4.1.
Universal Standard Service, Inc. Report No. ASL23051710 pin9 to GND (Jumper on COM1_SEL1, pin(1-2)) Output shutdown. No hazard. No damage. ASRE. COM (COM2), pin9 to GND (Jumper on COM2_SEL1, pin(1-2)) Overload 36Vdc See table 5.4.1.4 -- -- See table 5.4.1.4 COM (COM2), pin9 to GND (Jumper on COM2_SEL1, pin(1-2)) Short 36Vdc 30mins. -- -- -- See NT. NC. CT. table Normal 5.4.1.4 operation. No hazard. No damage. Open circuit voltage=12.0 4Vdc, Maximum available current=1500 mA. ASRE. -- NT.
Universal Standard Service, Inc. Report No. ASL23051710 components); @=Tests were repeated 2 more times (Totally 3 times) and get the same result; I/P=Input; O/P=Output, NSF=No Ignition; TC=Touch Current measured; ASRE=All Safeguards remain effective Annex M TABLE: Batteries P The tests of Annex M are applicable only when appropriate battery data is not available -- Is it possible to install the battery in a reverse polarity position? .........................
Universal Standard Service, Inc. Report No. ASL23051710 See below Battery identification Charging at Tlowest (C) Observation Charging at Thighest (C) Observation Supplementary Information: Annex Q.1 TABLE: Circuits intended for interconnection with building wiring (LPS) P Note: Measured UOC (V) with all load circuits disconnected: See below Output Circuit Components Uoc (V) Isc (A) S (VA) Meas. Limit Meas.
Universal Standard Service, Inc. Report No. ASL23051710 RJ-45 (LAN1) pin1-4,7-10 to GND, normal condition 0Vdc 0 8 0 100 RJ-45 (LAN2) pin1-4,7-10 to GND, normal condition 0Vdc 0 8 0 100 COM (COM1) (AF1) pin9 to GND, normal condition (Jumper on COM1_SEL1, pin(1-2)) 12.04Vdc 2.9 8 30.102 100 COM (COM1) pin1-8 to GND, normal condition (Jumper on COM1_SEL1, pin(1-2)) 0Vdc 0 8 0 100 COM (COM1) (AF1) pin9 to GND, normal condition (Jumper on COM1_SEL1, pin(3-4)) 5.06Vdc 2.9 8 10.
Universal Standard Service, Inc. Report No.
Universal Standard Service, Inc. Report No. ASL23051710 Supplementary information: (1) During and after the test, an accessible fire enclosure safeguard was not damaged or defeated. (2) No cracking, class 3 energy sources did not become accessible and all safeguards remain effective. Applied the steady force of 250 N over a circular plane surface 30 mm in diameter. T.6, T.
Universal Standard Service, Inc. Report No. ASL23051710 EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES (Audio/video, information and communication technology equipment Part 1: Safety requirements) EN 62368-1, GROUP DIFFERENCES Clause CONTENTS 1 Requirement + Test Result - Remark Verdict CENELEC COMMON MODIFICATIONS (EN) P Clauses, subclauses, notes, tables, figures and annexes which are additional to those in IEC 62368-1:2014 are prefixed “Z”.
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1, GROUP DIFFERENCES Clause Requirement + Test Result - Remark b) for components in series with the mains input to the equipment such as the supply cord, appliance coupler, r.f.i.
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1, GROUP DIFFERENCES Clause Requirement + Test Result - Remark Verdict 10.6.1 Add the following paragraph to the end of the subclause: EN 71-1:2011, 4.20 and the related tests methods and measurement distances apply. N/A 10.Z1 Add the following new subclause after 10.6.5. 10.
Universal Standard Service, Inc. Report No.
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1, GROUP DIFFERENCES Clause Requirement + Test Result - Remark completely filling the casing, so that clearances and creepage distances do not exist, if the component passes the electric strength test in accordance with the compliance clause below and in addition • passes the tests and inspection criteria of 5.4.8 with an electric strength test of 1,5 kV multiplied by 1,6 (the electric strength test of 5.4.
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1, GROUP DIFFERENCES Clause Requirement + Test Result - Remark 5.6.4.2.1 Ireland and United Kingdom After the indent for pluggable equipment type A, the following is added: – the protective current rating is taken to be 13 A, this being the largest rating of fuse used in the mains plug. N/A 5.6.5.
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1, GROUP DIFFERENCES Clause Requirement + Test Result - Remark Verdict of 1,5 kV r.m.s., 50 Hz or 60 Hz, for 1 min. Translation to Norwegian (the Swedish text will also be accepted in Norway): “Apparater som er koplet til beskyttelsesjord via nettplugg og/eller via annet jordtilkoplet utstyr – og er tilkoplet et koaksialbasert kabel-TV nett, kan forårsake brannfare.
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1, GROUP DIFFERENCES Clause Requirement + Test Result - Remark Verdict exceeding 13 A or if a poly-phase equipment is provided with a supply cord with a plug, this plug shall be in accordance with the standard sheets DK 6-1a in DS 60884-2-D1 or EN 60309-2. Mains socket outlets intended for providing power to Class II apparatus with a rated current of 2,5 A shall be in accordance DS 60884-2-D1:2011 standard sheet DKA 1-4a.
Universal Standard Service, Inc. Report No. ASL23051710 EN 62368-1, GROUP DIFFERENCES Clause Requirement + Test Result - Remark Verdict G.7.2 Ireland and United Kingdom To the first paragraph the following is added: A power supply cord with a conductor of 1,25 mm2 is allowed for equipment which is rated over 10 A and up to and including 13 A. N/A ZC ANNEX ZC, NATIONAL DEVIATIONS (EN) N/A 10.5.
Universal Standard Service, Inc. Report No.
Universal Standard Service, Inc. Report No.
Universal Standard Service, Inc. Report No.
Universal Standard Service, Inc. Report No.
Universal Standard Service, Inc. Report No.
Universal Standard Service, Inc. Report No.
Universal Standard Service, Inc. Report No.
Universal Standard Service, Inc. Report No.
Universal Standard Service, Inc. Report No.
Universal Standard Service, Inc. Report No.
Universal Standard Service, Inc. Report No.
Universal Standard Service, Inc. Report No.
Universal Standard Service, Inc. Report No.
Universal Standard Service, Inc. Report No.
Universal Standard Service, Inc. Report No.
Universal Standard Service, Inc. Report No.
Universal Standard Service, Inc. Report No.
Universal Standard Service, Inc. Report No.
Universal Standard Service, Inc. Report No.
Universal Standard Service, Inc. Report No.
Universal Standard Service, Inc. Report No.
Universal Standard Service, Inc. Report No.