Yale Real Living™ Push Button Lever Installation and Programming Instructions NOTE TO INSTALLER FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO THE PRODUCT AND VOID THE FACTORY WARRANTY For Technical Assistance call Yale at 1-800-810-WIRE (9473) This document is available on our website in printed Spanish and French. Go to www.yalecommercial.com. Click "Product Information & Documentation" and then "Installation Instructions".
TABLE OF CONTENTS Warnings..........................................................................................................................2 Return Lock to Factory Default.................................................................................3 Introduction......................................................................................................................3 Installation Components and Tools....................................................................................
To reset the lock to factory default, see the following: Reset Lock to Factory Default Reset Button The following procedure returns the lock to its factory defaults by deleting all user codes (including the Master PIN code*) and returning all programming features to their original default settings (see below). 1. Remove the batteries and then remove the inside escutcheon to access the reset button. 2. The reset button (see image at right) is located above the PCB cable connector. 3.
Industry Canada: Canadian ID: 6982A-YRHCPZW0 (Z-Wave); 6982A-YRHCPZB0 (Zigbee) Model(s): YRT210-ZW, YRT210-ZB This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
INSTALLATION COMPONENTS AND TOOLS Included in the box. . .
INSTALL LOCK Install Latch The lock is packed representative of how it will install on the door. Before installing the lock on the door: A. Remove the latch (Fig. 1) and strike plate from the packaging. NOTE: Latch ships with backset in 2-3/8" position (Fig. 1). Backset is the measurement from door edge to center of 2-1/8" diameter hole (see template supplied with lock). If required, pull to extend to 2-3/4" backset position (Detail 1A).
Install Outside Escutcheon NOTE: The "tops" of both the square drive tube and the hub (in the shank) are marked to indicate their orientation for proper installation (Figures A & B). Outside Escutcheon (with gasket) Outside of Door Do not remove clip from Outside Escutcheon shank until correct handing has been determined and Outside Lever Handle is to be installed. (See page 9) 1.
3. Install outside escutcheon. A. Position the outside escutcheon by routing the cable through 2-1/8" diameter hole (Fig. 3A), under the latch. Outside of Door Square Drive Tube is marked (WHITE) to indicate "top" NOTE: The "tops" of both the square drive tube and the tailpiece it contains are marked to indicate their proper orientation (Fig. 3A & 3B). B. Ensure tailpiece is oriented in the horizontal position (Fig.
6. Attach cable assembly to the inside escutcheon printed circuit board (PCB) by lining up notches on top of cable connector to slots on PCB connector (Fig. 6A & 6B). Press connector in firmly using thumbs until completely seated (properly seated position indicated by arrows on PCB as in Fig. 6A and 6B). Route cable as indicated do not cover holes Figure 6B Figure 6A CAUTION: Use care when assembling to ensure that the cable lies against the back recessed area of the inside escutcheon (Fig. 6A).
Determine Lever Handing Before proceeding with the next step, determine that the handing of the lever is correct. Both outside and inside lever handles should always point toward the door hinges. 8. Attach outside lever handle to the outside escutcheon: A. Once correct handing is determined, remove the clip from the shank (Fig. 8A) that has held the hub in its correct position. Do not rotate cam from its original position. B.
D. Insert key in cylinder (outside lever handle); rotate key 90° clockwise (Fig. 8E). E. Insert allen wrench (included) in set screw on side of shank (toward edge of door); turn clockwise to allow placement of lever handle over shank; do not overtighten. F. Push lever handle/key/cylinder in until hole on handle aligns with set screw. Hinge side of Door F 90° D Figure 8E E G. Insert allen wrench and tighten set screw by turning counter-clockwise (Fig. 8F). H.
9. Attach inside lever handle: A. Rotate thumbturn counter-clockwise to horizontal position (Fig. 9A). Figure 9A B. Insert allen wrench (included) in set screw on side of shank (toward edge of door); turn clockwise to allow placement of inside lever handle over shank. C. Turn set screw counter-clockwise to tighten. Figure 9B Figure 9C IMPORTANT: Before installing the batteries, test the mechanical operation of lock by rotating the outside and inside lever handles.
PROGRAMMING Programming Features-Menus-Keys-Definitions.............................................. 12-13 Operation........................................................................................................... 14-15 PROGRAMMING FEATURES - MENUS - KEYS - DEFINITIONS Outside Inside Hex Screw Battery Cover Network Module Slot Status Indicator Numbers Alkaline Batteries 4 AA Type Cylinder Menu and Icons Used in This Guide ~ Click the indicated number.
Definitions Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user PIN code access. When attempting to enter a code while the unit is in Lockout, the Status Indicator flashes RED and BLUE; the keypad flashes as well. Low Battery: When battery power is low, the Status Indicator flashes RED. If battery power is completely lost, use the key override. Master PIN Code: The Master code is used for programming and for feature settings.
OPERATION Register Master Code Before Programming* key to enter Master Code Registration. 1. Press the 2. Enter a 4-8 digit Master PIN code followed by the 11 Press the key to enter Master Code Registration. key. 2 Enter a 4-8 digit Master PIN code followed by the key. PIN code structure Maximum number of user codes is 250 with Network Module; without Network Module, maximum is 25 user codes. User Pin Code Registration User Codes can only be programmed through the Master Code*. key. 1.
Feature Programming Through Menu Mode Using Master PIN code* 1. Enter the 4-8 digit Master PIN code followed by the key. 2. Enter digit corresponding to the function to be performed followed by the key. Note: If the lock is connected to a network controller, it is recommended that it is programmed through the centralized user interface (PC or hand-held device) to ensure communication between the lock and the controller unit. *The Master PIN code must be registered prior to programming of the lock.
Open Door with PIN Code 1 2 3 Enter PIN code. Complete the code entry key. by pressing the Unlock.
MISCELLANEOUS Hardware Troubleshooting.......................................................................................17 Programming Troubleshooting................................................................................18 Installing the Network Module . ..............................................................................19 Change Lever Handing .................................................................................... 20-21 Replace/Install Cylinder . ......................
Programming Troubleshooting Symptom Suggested Action Lock does not respond – door is open and accessible. • • • • Press each keypad button to see if they respond when pressed. Check batteries are installed and oriented correctly (polarity) in the battery case. Check batteries are in good condition; replace batteries* if discharged. Check to see if cable is fully connected and not pinched. Lock does not respond – door is locked and inaccessible. • Batteries may be completely discharged.
Installing the Network Module IMPORTANT: The batteries must be removed prior to removing and/or inserting the network module: • Remove batteries • Remove and/or insert network module • Reinstall batteries Use Feature Programming step 7 (page 15) for enrollment of the Network Module.
How to Change Handing of Lever (Reverse Levers) 1. Remove the outside lever handle: A. Insert key in cylinder (outside lever handle); rotate key 90° clockwise. B. Insert allen wrench (included) in set screw on side of lever (toward edge of door); turn clockwise to loosen lever handle. C. Pull to remove lever handle/key/cylinder.
2. Remove the inside lever handle: A. Insert allen wrench (included) in set screw on side of lever (towards edge of door); turn clockwise to loosen handle. B. Pull to remove lever handle. B A 3. Change the lever handing: A. Remove and switch handles (inside to outside, outside to inside). B. Remove cylinder from outside lever handle. C. Insert cylinder in "new" outside lever (Fig. 3A). D. Push handle in allowing holes for set screw to align. E.
How to Replace or Install Cylinder 1. Remove cylinder: A. Repeat previous steps for removing the outside lever handle. B. Remove cylinder. 2. Install new cylinder: A. Insert cylinder in "new" outside lever. B. Push handle in allowing holes for set screw to align. C. Insert set screw and tighten by turning set screw counter-clockwise. D. Verify that new cylinder fits and rotates freely. E. Test operation of the new cylinder/key.
PIN CODE MANAGEMENT SAMPLE SHEETS PIN Code Management (No Network Module - Up to 25 Users) Location: User Type Door Number: User Name User # User User Name User # PIN Code PIN Code Master User 13 User 01 User 14 User 02 User 15 User 03 User 16 User 04 User 17 User 05 User 18 User 06 User 19 User 07 User 20 User 08 User 21 User 09 User 22 User 10 User 23 User 11 User 24 User 12 User 25 24 P/N AYRT-210-INST-FUL Rev A An ASSA ABLOY Group brand
PIN Code Management (With Network Module - Up to 250 Users) - Duplicate Sheet to record entries User Type User Name User # PIN Code User Master User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ Us
ONLINE LITERATURE AND TEMPLATES For the latest information on Yale products visit our website at www.yalelocks.com. Click on the “Literature” button to find the most up-to-date catalogs, parts manuals, templates, specifications and installation instructions. Yale Locks & Hardware 100 Yale Avenue, Lenoir City, TN 37771 • Product Support Tel 800.810.WIRE (9473) • www.yalelocks.com Yale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company.