Certification Exhibit FCC ID: U4A-SCYPROX3 IC: 6982A-SCYPROX3 FCC Rule Part: 15.209 IC Radio Standards Specification: RSS-210 ACS Report Number: 10-0443.W06.11.A Manufacturer: Assa Abloy Model: S1-PA/PK, S2-PA/PK, TCIP1-M802/M803, TCWI1-M802/M803 Manual(s) 5015 B.U.
v.S1 Profile PoE Mortise Lock Installation Instructions A7764B 01/11 Copyright 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
01/29/11 Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Table of Contents 1 Warning . ..................................................................................2 2 General Description..................................................................3 3 Hardware Specifications....................................................
Profile Series v.S1 PoE Mortise Lock 2 General Description The SARGENT Profile Series v.S1 Mortise Lock is available with either an HID® 125 kHz prox or 13.56 MHz iCLASS® technology reader. It utilizes existing infrastructure and IEEE 802.3af PoE (Power over Ethernet) technology as a proven alternative to traditional access control installations.The v.S1 is a self-contained microprocessor-controlled access control product with non-volatile memory.
Profile Series v.S1 PoE Mortise Lock 6 Installation Wiring A PoE frame harness assembly (From McKinney) D DPS: Door Position Switch (cylindrical and exits only) B PoE data hinge (Patent Pending) (From McKinney) E C PoE door harness* (From McKinney) Profile Series v.S1 Online P1 PoE lock * Order of installation may vary. Refer to appropriate sections for instructions.
Profile Series v.S1 PoE Mortise Lock A Frame Harness Installation Cut end / ceiling-side PoE harness: Supplied by CI Suggested installation of components and wire harness supplied by McKinney: B-Splice Crimp Connector TIA-568-B Standard Wiring 1 2 3 4 5 6 7 8 Pair Number 1 White/Blue 2 White/Orange RJ45-M Ceiling B White/Brown White/Blue 5 Blue 4 White/Orange 1 Orange 2 White/Green 3 Green 6 White/Brown 7 Brown 8 Do not confuse pair numbers with pin numbers.
Profile Series v.S1 PoE Mortise Lock C Door Harness Installation Ground Ring Terminal Order of installation may vary. Refer to appropriate sections for instructions. 1. Prop door open. 2. Tape the two lock-side 4-pin connectors to the ring terminal. 3. Using the ring terminal, carefully fish the assembly through the door channel to the lock. 4. Remove tape from ring terminal and door harness connectors.
Profile Series v.
01/29/11 Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Profile Series v.S1 PoE Mortise Lock 6 8 Parts Breakdown 125 kHz Prox and 13.56 MHz iCLASS 9 8 9 7 4 6 9 5 3 2 10 9 16 12 11 9 7 13 1 1-800-810-WIRE • www.sargentlock.
Profile Series v.S1 PoE Mortise Lock Parts Breakdown 125 kHz Prox and 13.56 MHz iCLASS, continued ITEM PART NO. DESCRIPTION QTY.
Profile Series v.S1 PoE Mortise Lock 8 Lock Installation Step #1 – Door Preparation A. Verify Hand and Bevel of Door Stand on outside of locked door when determining door hand. LH LHRB RH RHRB Left Hand Hinges Left Open Inward Left Hand Reverse Bevel Hinges Left Open Outward Right Hand Hinges Right Open Inward Right Hand Reverse Bevel Hinges Right Open Outward Fig. 1A B. Door Preparation Prior to installation, all holes must be free of burrs, debris and sharp edges.
Profile Series v.S1 PoE Mortise Lock Step #2 – How to Change Hand of Lockbody A. Reverse Lock Hand Red surface of locking piece must face the outside/locked side of door. To rotate locking piece (Fig. 2A): 1. Position lock body with red surface of locking piece visible. 2. Insert blade type screwdriver into locking piece slot to rotate locking piece toward back of lock body. 3. Rotate the locking piece 180° until RED surface is on opposite side. Note: Red indicates locked side (outside).
Profile Series v.S1 PoE Mortise Lock Ground Wire Step #3 – Install Lockbody 1. Feed the wires first through the mortise pocket and out the inside prep, followed by the lockbody (Fig. 3A). (2) 4-Pin Connectors From Hinge Note: Connectors and wires must be fed through non-cylinder side. 2. The wires from the lockbody exit the inside door prep through the mortise cutout. 3. Loosely secure the lockbody in the door with two #12 x 1-1/4” wood screws or #12-24 x 1/2” machine screws.
Profile Series v.S1 PoE Mortise Lock Step #5 – Install Gasket (for Exterior Doors) Gasket 82-0500 1. Carefully remove the backing from the gasket. 2. Apply gasket to escutcheon: Gasket • Starting in one place, press the adhesive side of the gasket firmly against the escutcheon. • Work around the escutcheon, pressing the sticky side of the gasket firmly against the escutcheon edge. Keypad Ribbon Cable • The gasket should be aligned so that all edges of the escutcheon are covered. Fig. 5A 3.
Profile Series v.S1 PoE Mortise Lock Step #7 – Escutcheon Wire Connections Images are shown without gasket. If gasket is necessary, refer to Step #5. Ground Ring Terminal Before the controller is attached to the door: 4-Pin Connectors From Hinge 1. Attach the reader assembly ribbon cable into the back of the controller assembly (side that faces towards the door when mounted (Fig. 7C Detail). 1 3 2. Attach the antenna to the circuit board in the plastic housing under the controller assembly.
Profile Series v.S1 PoE Mortise Lock Step #9 – Ciruit Board Wiring Before installing escutcheon, route raceway cables and ground attach to front of circuit board. Turn the controller assembly over: Ground Ring Terminal 1. Route the raceway connectors over the top of the controller assembly and plug into the front of the circuit board (side that faces out when mounted (J7, J4; Fig. 9A). 2.
Profile Series v.S1 PoE Mortise Lock Step #11 – Install Inside Lever 1. Slide lever handle onto spindle until fully seated (Fig. 11A). 2. Tighten the set screw securely with 1/8” hex wrench. Spindle Step #12 – Install and Secure Cylinder Set Screw 1. Slide cylinder through the spring and rosette/collar and screw into lockbody, rotating the cylinder clockwise (Fig. 12A). Cylinder should be flush with rosette/collar. Fig. 11A Note: SARGENT logo must be horizontal and on the top of the cylinder (Fig.
Profile Series v.S1 PoE Mortise Lock Step #13 – Attach Front Plate Attach front plate with (2) flat head screws. Outside of Door Front Plate (2) Flat Head Screws Lock body Screws Fig. 13A Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Operational Check 1A.
SARGENT Manufacturing 100 Sargent Drive New Haven, CT 06511 USA 800-810-WIRE (9473) • www.sargentlock.com Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices, electro-mechanical products and access control systems for new construction, renovation, and replacement applications. The company’s customer base includes commercial construction, institutional, and industrial markets. Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company.