IN100 with Aperio™ Technology Cylindrical Lock Installation Instructions A8189B 07/16 Copyright 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
Table of Contents Warning ....................................................................................3 General Description..................................................................4 Hardware Specifications..........................................................4 Electronic Specifications..........................................................4 Parts Breakdown......................................................................5 Lock Installation........................................
IN100 Cylindrical Lock General Description 2 The SARGENT® IN100 mortise lock with Aperio™ Technology makes it easy and cost-effective to bring access control to more doors. It uses local wireless communication between the lock and an Aperio hub to connect to an access control system, eliminating the greatest cost and inconvenience of traditional access control – the wiring at the door.
IN100 Cylindrical Lock 5 Parts Breakdown 2 1 1 3 4 1 2 DESCRIPTION COLOR/TRIM QTY IN-100-EM0110G77-IP-B ® HID iCLASS , HID iCLASS SE (SIO-enabled), HID iCLASS Seos™, HID MIFARE SE, HID DESfire® EV1 SE, HID Prox®, NFC-enabled mobile phones Black 1 IN-100-EM0110G77-IP-W HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE® SE, HID DESfire® EV1 SE, HID Prox®, NFC-enabled mobile phones White 1 IN-100-EM0110G77-IP-MB-[xxx]* HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID i
IN100 Cylindrical Lock Parts Breakdown (Continued) 5 11 12 4 8* 7 3 1 6 5 4 9 2 Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. PART NO./ORDER STRING ITEM 07/31/16 10 *Adapter Plate/Spacer (10-0847) is only shipped with orders that specify 1-3/8” doors. 13 1 --- 2 10-0043 3 4 5 DESCRIPTION QTY.
IN100 Cylindrical Lock 6 Lock Installation 1 Prepare Door A. Verify Hand and Bevel of Door Stand on outside of locked door when determining door hand. Fig. 1A LH LHRB RH RHRB Left Hand Hinges Left Open Inward Left Hand Reverse Bevel Hinges Left Open Outward Right Hand Hinges Right Open Inward Right Hand Reverse Bevel Hinges Right Open Outward B. Prepare Door Prior to installation, all holes must be free of burrs, debris and sharp edges.
IN100 Cylindrical Lock Centerline of Latch Front and Strike 2 Install Strike Install strike in the door frame (Fig. 2). (2) #8-32 x 3/4" Latch Screws Fig. 2 3 Install Latchbolt 1. Install latch with beveled bolt facing the strike. 2. Attach with two screws but DO NOT tighten completely at this time. See section 8 - Secure Lock to the Door. Inside of Door IMPORTANT: Latch bevel must match door bevel and deadlocking latch must stop on strike when door is closed.
IN100 Cylindrical Lock 5 Lock Adjustments A. Lock Preset: • Lockbody holes: 12 and 6 o’clock (Fig. 5). The lock is shipped “preset” and does not require adjustment for 1-3/4” thick doors. Outside of Door Fig. 5 NOTE: Adjusting for a thicker door requires removal of the outside lever, scalp and spacer bushing; see the following sections. If preset lock does not require adjustment, proceed to Section 7 - Install Lock. 1-800-810-WIRE • www.sargentlock.
IN100 Cylindrical Lock 6 Through-Bolt and Door Thickness Adjustment (If Required) A. Remove Outside Lever 1. Insert key, rotate 45° clockwise and hold. 2. Depress lever retainer with push pin tool (provided). 3. Pull lever outward. 07/31/16 Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Outside of Door B.
IN100 Cylindrical Lock C. Through-Bolt and Door Thickness Adjustment 1. (If necessary) remove outside lever, scalp and spacer bushing (Fig. 6C). Spacer Bushing Scalp Outside Lever Fig. 6C Refer to markings on through-bolt post (Fig. 6C Detail). 1-3/4” Thick Doors 2” Thick Doors Fig. 6C Detail 3. Re-install spacer bushing to align with back of lever, scalp, and lever (Fig. 6D). Fig. 6D 1-800-810-WIRE • www.sargentlock.
IN100 Cylindrical Lock 7 Install Lock 1. From outside of door feed lockbody harness into the lockbody hole (Fig. 7A). For metal door: Feed harness through inside of door (not shown). 2. Continue to feed harness into raceway (towards top of door), exiting raceway hole on inside of door (Fig. 7B). 3. Slide lockbody into cross-bore hole from outside of door. 4. Lockbody must engage both the latch unit prongs and tail piece (Fig. 7C).
IN100 Cylindrical Lock 8 Secure Lock to the Door 1. Slide inside rose assembly and spacer bushing over lockbody. 2. Position ground lug between (top) #10-32x1-1/4” through-bolt and rose assembly (Fig. 8A). NOTE: Proper placement of ground wire (Fig. 8B) will prevent pinching/damage to the ground wire. Inside of Door 3. Secure rose assembly with (2) #10-32x1-1/4” through-bolts. 4. Secure latch by fully tightening (2) #6 x 3/4” self-tapping screws (refer to previous section 3 - Install Latchbolt).
IN100 Cylindrical Lock 10 Outside Reader Installation 1. Orient the reader so the LED lens is at the top (Fig. 10A). 2. Feed the cable/connector through the door (from outside to inside). 3. Install the reader to the outside of door by aligning the mounting posts with the door preparation holes. Hold the reader flush against door while ensuring proper alignment. NOTE: Cable lengths exaggerated for illustrative purposes.
IN100 Cylindrical Lock 10 Outside Reader Installation (Continued) 4. Feed the reader harness and DPS connectors through the inside mounting assembly (and gasket if required*). See Figure 11B. IMPORTANT: Do not run wires through bottom flange hole in plate (Fig. 11B, C) - it will damage wires and the controller connector. Route wires around flange, do not route wires through the flange hole (Fig. 11C). 5. Tuck excess cable into wire hole on inside of door. 6.
IN100 Cylindrical Lock 10 Outside Reader Installation (Continued) Installation of Connectors CAUTION - Do not touch or allow debris to enter connector contacts. DPS (4-pin) 9-24VDC Power* A Secure the following connectors to their respective terminals (Fig. 11D): A. Secure the 4-pin DPS connector. B. Secure the 10-pin lock body assembly connector. Ground Lug *NOTE: Optional 2-pin external 9-24VDC power connector.
IN100 Cylindrical Lock 11 Installation of Inside Component Assembly (Controller) 1. Insert top tabs of controller into slots on mounting plate (Fig. 12). 2. Ensure proper alignment of board-to-board connectors while pivoting bottom of controller toward door until tab on bottom snaps securely into place on mounting plate. CAUTION: To avoid possible damage to board-to-board connectors, care should be taken when securing controller to mounting plate.
IN100 Cylindrical Lock 13 Battery Installation 1. Place (6) “AA” alkaline batteries in the compartment, being careful to align polarity properly (Fig. 12). 2. After batteries are installed, there is a slight delay; then red and green flash*, audible “beep” and lock motor will cycle. AA Batteries (6) *See Section 8 - LED Indications for more information 07/31/16 Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
IN100 Cylindrical Lock Operational Check 1. Insert key into cylinder and rotate (Fig. 14A). There should be no friction against lock case, wire harness or any other obstructions. 2. Check that the key retracts the latch. Fig. 14A Note: The credential should approach the inscription on the reader as indicated (Fig. 14B) to ensure the credential is read properly. Do not wave credential. Fig. 14B 1-800-810-WIRE • www.sargentlock.
IN100 Cylindrical Lock 8 LED Indications The communication hub has a single LED. It supports an optical scheme of red, green and yellow. The indication scheme is described by the figures below: Communication Hub LED indications Figure 1. Communication hub normal operation LED indication 2 sec. Online Green Aperio® lock offline EAC offline Green + one red flash Green + two red flashes 07/31/16 Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
IN100 Cylindrical Lock Lock LED indications The lock has three LEDs. They support an optical scheme with red, yellow and green.
IN100 Cylindrical Lock Lock Self-Test LED indication After replacing batteries, a Power on Self Test (POST) is performed. The result is indicated using a series of red and green LED flashes as described by the figures below. LED indication after power up/replacement of the battery 8.3.
SARGENT Manufacturing 100 Sargent Drive New Haven, CT 06511 USA 800-810-WIRE (9473) • www.sargentlock.com Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices, electro-mechanical products and access control systems for new construction, renovation, and replacement applications. The company’s customer base includes commercial construction, institutional, and industrial markets. Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company.