IN100 with Aperio™ Technology Mortise Lock Installation Instructions A8190B 07/16 Copyright 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
Table of Contents Warning ....................................................................................3 General Description..................................................................4 Specifications...........................................................................4 System Overview......................................................................4 Parts Breakdown......................................................................5 Lock Installation..............................
IN100 Mortise Lock 2 General Description ® The SARGENT IN100 mortise lock with Aperio™ Technology makes it easy and cost-effective to bring access control to more doors. It uses local wireless communication between the lock and an Aperio hub to connect to an access control system, eliminating the greatest cost and inconvenience of traditional access control – the wiring at the door.
IN100 Mortise Lock 5 Parts Breakdown 1* 2 1 3 1 DESCRIPTION COLOR/TRIM QTY IN-100-EM01[locktype]*-IP-B ® HID iCLASS , HID iCLASS SE (SIO-enabled), HID iCLASS Seos™, HID MIFARE SE, HID DESfire® EV1 SE, HID Prox® Black 1 IN-100-EM01[locktype]*-IP-W HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE® SE, HID DESfire® EV1 SE, HID Prox® White 1 IN-100-EM01[locktype]*-IP-MB-[xxx]* HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE® SE, HID DESfire® EV1
IN100 Mortise Lock Parts Breakdown (Continued) 5 1 2 4 9 5 5 5 6 7 10 10 11 3 5 5 07/31/16 Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
IN100 Mortise Lock 6 Lock Installation 1 Prepare Door A. Verify Hand and Bevel of Door Stand on outside of locked door when determining door hand. Fig. 1A LH LHRB RH RHRB Left Hand Hinges Left Open Inward Left Hand Reverse Bevel Hinges Left Open Outward Right Hand Hinges Right Open Inward Right Hand Reverse Bevel Hinges Right Open Outward B. Door Preparation Prior to installation, all holes must be free of burrs, debris and sharp edges.
IN100 Mortise Lock 2 How to Change Hand of Lock body A. Reverse Lock Hand 1. Position lock body so the red surface of the locking piece is visible. 2. Insert blade type screwdriver into locking piece slot to rotate locking piece. 3. Push locking piece toward the back of the lock body and rotate the locking piece 180°. Note: Red indicates locked (outside) side. Deadlatch B. Reverse Latch Hand 1. Rotate the latchbolt 180°. 2. Flip deadlatch by hand to match bevel of latchbolt. Locking piece Fig.
IN100 Mortise Lock 4 Install Door Position Switch (DPS) 1. Insert DPS into the raceway on the latch edge of the door. 2. Push wires through raceway toward lock prep. 3. Push DPS firmly into place by hand. Note: DO NOT TAP SWITCH WITH ANY TOOL. Door Position Switch (DPS) 4. Install magnet into door frame. Push firmly into place by hand. See A7983. 5. To connect DPS to lock controller per diagram, refer to the wiring in Step #10. 5 Install Lock body 1.
IN100 Mortise Lock 6 Outside Cylinder Installation 1. Slide the spring and the rosette onto the cylinder. 2. Rotate the cylinder into cylinder hole with fingers. 3. Insert key 75% of the way and utilize the key to rotate the cylinder into the rest of the cylinder hole. Note: Do not attempt to tighten all the way. 4. Verify that orientation of cylinder has the SARGENT logo as shown in Fig. 6A. IMPORTANT: Position cylinder so that the SARGENT logo is positioned correctly. 5.
IN100 Mortise Lock 7 Assemble Outside Trim 1. With outside lever horizontal (and handle pointing toward door hinge), insert the mounting posts through outside of door and lock body. Make certain the lever spindle is properly engaged inside the lock body (Fig 7A). 2. On the inside of the door, insert spindle into square hole of mortise lock, with spindle slot directed away from the mortise lock body, and aligned with the set screw hole in the Inside adapter (Fig 7B). 3.
IN100 Mortise Lock 8 Install Inside Rose and Inside Lever Assembly 1. Place inside rose flush against door surface and rotate first counter-clockwise to seat the threads, then clockwise to securely tighten. 2. Slide lever onto spindle until fully seated. Be sure handle is horizontal and facing the hinge side of the door. Push lever onto spindle so minimum gap is visible. 3. Tighten the set screw securely with a T20 Torx® driver. 4. Finish securely tightening (2) #12-24 lock body screws. 5.
IN100 Mortise Lock 9 Install Thumb Turn 1. Insert thumb turn into preparation hole and engage slot in lock body. 2. Orient mounting plate so screw hole is vertical (aligned with preparation holes). 3. Secure plate with Phillips screw provided. 4. Test thumb turn for function by retracting and projecting the deadbolt (7976 and 7977 functions only). Inside of Door Thumb Turn Phillips screw Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
IN100 Mortise Lock 11 Outside Reader Installation 1. Orient the reader so the LED lens is at the top. 2. Feed the cable/connector through the door (from outside to inside). 3. Install the reader to the outside of door by aligning the mounting posts with the door preparation holes. Hold the reader flush against door while ensuring proper alignment. Outside of Door 07/31/16 Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
IN100 Mortise Lock 11 Outside Reader Installation (Continued) 4. Feed the reader harness and DPS connectors through the inside mounting assembly (and gasket if required*). See Figure 11B. IMPORTANT: Do not run wires through bottom flange hole in plate (Fig. 11B, C) - it will damage wires and the controller connector. Route wires around flange, do not route wires through the flange hole (Fig. 11C). 5. Tuck excess cable into wire hole on inside of door. 6.
IN100 Mortise Lock 11 Outside Reader Installation (Continued) Installation of Connectors CAUTION - Do not touch or allow debris to enter connector contacts. DPS (4-pin) 9-24VDC Power* A Secure the following connectors to their respective terminals (Fig. 11D): A. Secure the 4-pin DPS connector. B. Secure the 10-pin lock body assembly connector. Ground Lug *NOTE: Optional 2-pin external 9-24VDC power connector.
IN100 Mortise Lock 12 Installation of Inside Component Assembly 1. Insert top tabs of controller into slots on mounting plate (Fig. 12). 2. Ensure proper alignment of board-to-board connectors while pivoting bottom of controller toward door until tab on bottom snaps securely into place on mounting plate. CAUTION: To avoid possible damage to board-to-board connectors, care should be taken when securing controller to mounting plate.
IN100 Mortise Lock 13 Battery Installation 1. Place (6) “AA” alkaline batteries in the compartment, being careful to align polarity properly (Fig. 13). 2. After batteries are installed, there is a slight delay; then red and green flash, audible “beep” and lock motor will cycle. *See Section 8 - LED Indications for more information AA Batteries (6) Fig. 13 Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
IN100 Mortise Lock Operational Check For 7976- and 7978-function mortise locks with cylinders: 1. Insert key into cylinder and rotate. There should be no friction against lock case, wire harness or any other obstructions. 2. Check that the key retracts the latch: the key should rotate freely. 3. Throw the deadbolt (if present): Check that the key retracts both the deadbolt and the latch. 4. Try the inside lever: Ensure it retracts latch and deadbolt (if provided). 5.
IN100 Mortise Lock 8 LED Indications The communication hub has a single LED. It supports an optical scheme with red, green and yellow. The indication scheme is described by the figures below: Communication Hub LED indications Figure 1. Communication hub normal operation LED indication 2 sec.
IN100 Mortise Lock Lock LED indications The lock has three LEDs. They support an optical scheme of red, yellow and green.
IN100 Mortise Lock Lock Self-Test LED indication After replacing batteries, a Power on Self Test (POST) is performed. The result is indicated using a series of red and green LED flashes as described by the figures below. LED indication after power up/replacement of the battery 8.3.
SARGENT Manufacturing 100 Sargent Drive New Haven, CT 06511 USA 800-810-WIRE (9473) • www.sargentlock.com Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices, electro-mechanical products and access control systems for new construction, renovation, and replacement applications. The company’s customer base includes commercial construction, institutional, and industrial markets. Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company.