Cylindrical Lockset IN100 WiFi Installation Instructions FM404 07/16 Attention Installer Please read these instructions carefully to prevent missing important steps. Please Note: Improper installations may result in damage to the lock and void the factory warranty. Important: The accuracy of the door preparation is critical for proper functioning and security of this lock. Misalignment can cause premature wear and a lessening of security.
IN100 Cylindrical Lock Table of Contents 1) Warning.................................................................................2 2) General Description..............................................................3 3) Specifications / Features.....................................................3 4) Product Illustration..............................................................4 5) Installation Instructions.......................................................6 6) Operational Check...............
IN100 Cylindrical Lock 2) General Description The Corbin Russwin® IN100 lock with Aperio™ Technology makes it easy and cost-effective to bring access control to more doors. It uses local wireless communication between the lock and an Aperio hub to connect to an access control system, eliminating the greatest cost and inconvenience of traditional access control – the wiring at the door. The IN100 utilizes HID® 125 kHz prox or 13.
IN100 Cylindrical Lock 4) Product Illustration 2 1 3 4 5 Reader Module ITEM PART NUMBER/ORDER STRING 1 DESCRIPTION COLOR/TRIM QTY IN-100-EM01CL33134-IP-B ® HID iCLASS , HID iCLASS SE (SIO-enabled), HID iCLASS Seos™, HID MIFARE SE, HID DESfire® EV1 SE, HID Prox®, NFC-enabled mobile phones Black 1 IN-100-EM01CL33134-IP-W HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE® SE, HID DESfire® EV1 SE, HID Prox®, NFC-enabled mobile phones White 1 IN-100-EM01CL33134-IP-MB-[
IN100 Cylindrical Lock 4) Product Illustration (Continued) Tools Required: • Phillips Screw Driver #2, #3 • Flat Blade Screw Driver (Standard size) • 1/8” Security Allen Wrench (supplied) 4 2 3 1 1* 785F628 CL33134 Cylindrical lock with fixed core cylinder 785F638 CL33134 Cylindrical lock with removable core cylinder 785F488 Inside Spring Cassette - IN100 REX (1-3/4” - 2” Door) 785F498 Inside Spring Cassette - IN100 REX (2-1/4” Door) 3 783F208 Outside Spring Cassette 1 4 820F609 DPS (D
IN100 Cylindrical Lock 5) Installation Instructions 1. Verify Hand and Bevel of door Illustrations shown are as viewed from the outside or secure side of opening. Left Hand Hinges Left. Open Inward. “LH” 2. Left Hand Reverse Bevel Hinges Left. Open Outward “LHRB” Right Hand Hinges Right. Open Inward. “RH” Fig. 1 Right Hand Reverse Bevel Hinges Right. Open Outward “RHRB” Door Preparation Prep door according to supplied door marker (FM356). For door manufacturer templates visit www.corbinrusswin.
IN100 Cylindrical Lock 5) Installation Instructions (Continued) 3. Install Door Position Switch (DPS) a. Insert DPS into the raceway on the latch edge of the door. b. Push wires through raceway toward lock prep. c. Push DPS firmly into place by hand. Note: DO NOT TAP SWITCH WITH ANY TOOL. d. Install magnet into door frame. Push firmly into place by hand. See instruction A7983A. CAUTION: if DPS is not installed or is installed improperly, door status monitoring features will not function. Fig. 3 4.
IN100 Cylindrical Lock 5) Installation Instructions (Continued) 6. Install Lock Body a. Feed lock body and wire through 2-1/8” diameter hole from outside of door (Fig. 6a). Engage latch with lock body. Latch ears must slide into housing as shown (Fig. 6b). b. Connect 4-pin connector from lock body to 4-pin on cassette (Fig. 6c). Outside Face of Door 6 Fig. 6b Fig. 6a c. Temporarily install top throughbolt to hold chassis in door (Fig. 6c). Important: Door must remain open during installation.
IN100 Cylindrical Lock 5) Installation Instructions (Continued) 7. Install Inside Spring Cassette Lock a. Feed harness wires and ground wire up through raceway (Fig. 7a). b. Remove screw from previous step. c. Slide on cassette and secure with (2) screws (Fig. 7b). Remove Screw Fig. 7a Fig. 7b Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
IN100 Cylindrical Lock 5) Installation Instructions (Continued) 8. Installation and Removal of Lever and Standard Cylinder Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
IN100 Cylindrical Lock 5) Installation Instructions (Continued) 9. Install Outside (Reader) Escutcheon and Inside Mounting Plate a. Orient the reader so the LED lens is at the top. b. Feed reader harness through door (from outside to inside). c. Install the reader to the outside of door by aligning the mounting posts with the door preparation holes. Hold the reader flush against door while ensuring proper alignment. Outside Face of Door LED Reader Assembly with Harness Fig.
IN100 Cylindrical Lock 5) Installation Instructions (Continued) d. Feed the reader harness and DPS connectors through the inside mounting assembly (and gasket if required*). See Figure 9b. IMPORTANT: Do not run wires through bottom flange hole in plate (Fig. 9b, c) - it will damage wires and the controller connector. Route wires around flange, do not route wires through the flange hole (Fig. 9c). e. Tuck excess cable into wire hole on inside of door. f.
IN100 Cylindrical Lock 5) Installation Instructions (Continued) 10. Installation of Connectors CAUTION - Do not touch or allow debris to enter connector contacts. DPS (4-pin) 9-24VDC Power* A Secure the following connectors to their respective terminals (Fig. 10D): A. Secure the 4-pin DPS connector. B. Secure the 10-pin lock body assembly connector. *NOTE: Optional 2-pin external 9-24VDC power connector.
IN100 Cylindrical Lock 5) Installation Instructions (Continued) 11. Installation of Inside Component Assembly CAUTION: To avoid possible damage to board-to-board connectors, care should be taken when securing controller to mounting plate. If there is resistance when securing, detach controller to determine cause before re-attaching controller. a. Insert top tabs of controller into slots on mounting plate (Fig. 11). b.
IN100 Cylindrical Lock 5) Installation Instructions (Continued) 12. Battery Installation 1. Place (6) “AA” alkaline batteries in the compartment, being careful to align polarity properly (Fig. 12). 2. After batteries are installed, there is a slight delay; then red and green flash, audible “beep” and lock motor will cycle. Fig. 12 13. Inside Cover Installation Inside Cover a. Assemble cover by hooking top edge on inside mounting plate. b.
IN100 Cylindrical Lock 6) Operational Check When lock is fully installed, perform the following steps: a. Insert key into cylinder and rotate (Fig. 14a). b. There should be no friction against lock case, wire harness or any other obstructions. c. Check that the key retracts the latch. d. The key should rotate freely. e. Try the inside lever; ensure it retracts latch. f. Present a valid credential* (Fig. 14b) to unlock outside lever; turn lever handle to ensure latch retracts. Fig.
IN100 Cylindrical Lock 7) LED Indications The communication hub has a single LED. It supports an optical scheme of red, green and yellow. The indication scheme is described by the figures below: Communication Hub LED indications Figure 1. Communication hub normal operation LED indication 2 sec.
IN100 Cylindrical Lock Lock LED indications The lock has three LEDs. They support an optical scheme of red, yellow and green. The indication scheme is described by the figures below: Figure 4. Lock normal operation LED indication Card + PIN access (configurable) EAC response time Card access (configurable) Enter PIN One yellow flash after card, two flashes before PIN (.125 second) One yellow flash (.25 second) One green flash (1 sec.) Access granted, EAC offline or online One red flash (1 sec.
IN100 Cylindrical Lock Lock Self-Test LED indication After replacing batteries, a Power on Self Test (POST) is performed. The result is indicated using a series of red and green LED flashes as described by the figures below. LED indication after power up/replacement of the battery 8.3.
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.