Certification Exhibit FCC ID: U4A-SCYICLS3 IC: 6982A-SCYICLS3 FCC Rule Part: 15.225, 15.249 IC Radio Standards Specification: RSS-210 ACS Project Number: 11-0394 Manufacturer: Assa Abloy Model: C2-IA/IK Manual 5015 B.U.
C2 Incepta™ Series C2 with Aperio™ Technology Mortise Lock Installation Instructions A8122A Pre-Launch Draft 11/11 Copyright 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
Table of Contents Warning . ..................................................................................2 General Description..................................................................3 Specifications...........................................................................3 System Overview......................................................................3 Parts Breakdown......................................................................4 Lock Installation..............................
Profile Series C2 Mortise Lock 2 General Description The SARGENT® Incepta Series C2 lock with Aperio™ Technology makes it easy and cost-effective to bring access control to doors. It uses local wireless communication between the lock and an Aperio hub to connect to an access control system, eliminating the greatest cost and inconvenience of traditional access control – the wiring at the door. The Incepta Series C2 utilizes HID® iCLASS® 13.
Profile Series C2 Mortise Lock Parts Breakdown 5 13.56 MHz iCLASS 9 8 7 3 4 3 6 6 5 2 1 10 19 11/11/11 Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 20 18 17 21 22 22 20 Tools Required: 16 16 14 15 4 1-800-810-WIRE • www.sargentlock.
Profile Series C2 Mortise Lock Parts Breakdown 13.56 MHz iCLASS (Continued) QTY.
Profile Series C2 Mortise Lock 6 Lock Installation 1 Prepare Door A. Verify Hand and Bevel of Door Stand on outside of locked door when determining door hand. LH LHRB RH RHRB Left Hand Hinges Left Open Inward Left Hand Reverse Bevel Hinges Left Open Outward Right Hand Hinges Right Open Inward Right Hand Reverse Bevel Hinges Right Open Outward Fig. 1A B. Door Preparation Prior to installation, all holes must be free of burrs, debris and sharp edges.
Profile Series C2 Mortise Lock 2 How to Change Hand of Lock body A. Reverse Lock Hand 1. Position lock body so the red surface of the locking piece is visible. 2. Insert blade type screwdriver into locking piece slot to rotate locking piece. 3. Push locking piece toward the back of the lock body and rotate the locking piece 180° until RED surface is on opposite side. Note: Red indicates locked (outside) side. B. Reverse Latch Hand 1. Rotate the latchbolt 180°. Red locking piece 2.
Profile Series C2 Mortise Lock 4 Assemble Trim 1. With outside lever horizontal, insert the mounting post through outside of door and lock body. Make certain the lever spindle is properly engaged inside the lock body (Fig 4A). 2. On the inside of the door, insert spindle into square hole of mortise lock (Fig 4B). 3. Slide inside adapter and plate assembly over spindle and secure with (2) 8-32 X 5/8” Phillips oval head and lock washer machine screws.
Profile Series C2 Mortise Lock 6 Outside Cylinder Installation 1. Slide the spring and the rosette onto the cylinder. 2. Rotate the cylinder into cylinder hole with fingers. 3. Insert key 75% of the way and utilize the key to rotate the cylinder into the rest of the cylinder hole. Note: Do not attempt to tighten all the way. 4. Verify the orientation of the cylinder has the Sargent logo as depicted in Fig. 6A. 5. Hand tighten the cylinder clamp set screw to prevent unscrewing of the cylinder (Fig 6C). 5.
Profile Series C2 Mortise Lock 8 Attach Front Plate Attach front plate with (2) flat head screws. Outside of Door (2) flat head screws 11/11/11 Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Fig. 8 9 DPS (Door Position Switch) Installation 1.
Profile Series C2 Mortise Lock 10 Inside Mounting Plate Installation Mounting Plate 1. Assemble (1) washer to each through bolt (2 sets provided) 2. Insert through bolts and washers into upper and lower mounting plate holes. 3. Assemble fire shield to mounting plate by aligning the mounting plate posts with holes.. 2x Through bolts Fig. 10A Fire shield Inside of Door 2x Through bolts open slot Fig.
Profile Series C2 Mortise Lock 12 Gasket Installation (Optional P/N 52-1332) Fire-rated doors require a gasket on the outside of the door (Fig. 11A). 1. Place the gasket on the on the reader posts. 2. Continue to step 13. Fig. 12 13 Outside Reader Installation 11/11/11 Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 1.
Profile Series C2 Mortise Lock Inside of Door 14 Configuring RX Switch Handing Wire harness 1. Each lever handle has a sensor installed but only the inside lever is utilized for RX sensing. 2. To properly configure the RX functionality, connect the terminals as indicated below: RH or RHRB door handing (blue to blue) LH or LHRB door handing (yellow to blue) 3. Note: Factory default is blue to blue IMPORTANT: grasp each connector firmly before separating. Do not pull wires apart.
Profile Series C2 Mortise Lock Inside of Door 16 Secure Battery Housing 1. Position the DPS and harness below the tabs of the mounting plate. 2. Align the tabs of the battery housing with the tabs of the mounting plate. Push down. 3. Lightly press the lock harness to assemble. 4. Snap battery compartment into position. 11/11/11 Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Profile Series C2 Mortise Lock 18 Inside Cover Installation 1. Assemble cover by hooking top edge on inside mounting plate. 2. Carefully press bottom of cover toward door without pinching any wires. 3. Secure the cover utilizing a 1/8” security Allen wrench. Inside of Door Inside Cover 1/8” Security Allen Screw Fig. 18 Maintenance 1-800-810-WIRE • www.sargentlock.com • A8122A Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Profile Series C2 Mortise Lock 8 Operational Check For 7976- and 7978-function mortise locks with cylinders: 1. Insert key into cylinder and rotate. There should be no friction against lock case, wire harness or any other obstructions. (Refer to Section -6 Wiring if harness friction exists). 2. Check that the key retracts the latch: The key should rotate freely. 3. Throw the deadbolt: Check that the key retracts both the deadbolt and the latch. 4.
Profile Series C2 Mortise Lock Lock LED Indications 1 Lock Normal Operation LED indication The lock has three LED lights that support an optical scheme with red, yellow and green. The indication scheme is described by the figures below: Card read (configurable) One yellow flash (.25 second) Access granted, EAC offline or online One green flash (1 second) Access denied, EAC online One red flash (1 second) Access denied, EAC offline Three red flashes (.
3 Lock Self Test LED Indication After replacing the battery, a Power On Self Test (POST) is performed. The result is indicated using a series of red and green LED flashes as is described by the figure below: One red, one green flash (1 second each) One red flash followed by 16 red or green flashes (.5 s each) Fig. Lock POST LED indication The first flash is always red.