Certification Exhibit FCC ID: U4A-SCYICLS2 IC: 6982A-SCYICLS2 FCC Rule Part: 15.225 IC Radio Standards Specification: RSS-210 ACS Report Number: 11-0071.W06.11.A Manufacturer: Assa Abloy, Inc. Model: TCPIP-M819/M820,TCPWI-M819/M820 Manual 5015 B.U.
700 TCPWI1/TCPIP1 ™ Installation Instructions ML20700 TCPWI1 & TCPIP1Series Mortise Lockset FM324 04/11 Attention Installer Please read these instructions carefully to prevent missing important steps. Please Note: Improper installations may result in damage to the lock and void the factory warranty. Important: The accuracy of the door preparation is critical for proper functioning and security of this lock. PR EL IM IN AR Y Misalignment can cause premature wear and a lessening of security.
ML20700 PWI/PIP Series Mortise Lock Table of Contents 1) Warning Y 1) Warning.................................................................................2 2) General Description..............................................................3 3) Specifications / Features.....................................................3 4) Product Illustration..............................................................4 5) Installation Instructions.......................................................
ML20700 PWI/PIP Series Mortise Lock 2) General Description Designed specifically for the campus market, the Corbin Russwin Access 700 series mortise Locks are available in WiFi (PWI) and PoE (PIP) configurations. Coupled with third party software the PWI and PIP offers a complete, integrated access control system. The Access 700 may be used for both indoor and outdoor applications (weather-protective gasket supplied). HID and iCLASS are registered trademarks of HID Global Corporation.
ML20700 PWI/PIP Series Mortise Lock 4) Product IllustrationPoE Lock with Magnetic Card Swipe, 125 kHz Prox and Keypad 14 13 11 9 12 11 10 8 AR IN 3 5 PR EL IM 1 2 4 5 6 Y 5 7 ITEM No. Inside Outside PART No.
ML20700 PWI/PIP Series Mortise Lock 4) Product IllustrationMagnetic Card Swipe With 13.56 MHz iCLASS and Keypad (M820) 4 9 8 Y 7 AR 6 4 5 4 IN 3 IM 2 PR EL 1 4 4 10 ITEM No. PART No.
ML20700 PWI/PIP Series Mortise Lock 5) Installation Instructions 1. Verify Hand and Bevel of door: Right Hand Hinges Right. Open Inward. “RH” Right Hand Reverse Bevel Hinges Right. Open Outward “RHRB” IN Prep door according to door template T31167 : visit www.corbinrusswin.com. Through Bolt Holes Backplate Mount Holes PR Remote Power and POE Raceway EL IM 2. Left Hand Reverse Bevel Hinges Left. Open Outward “LHRB” AR Left Hand Hinges Left. Open Inward.
ML20700 PWI/PIP Series Mortise Lock 5) Installation Instructions (Continued) 3. Handing of Lock Body: If necessary re-hand latch and move RED locking screw to side of lockbody to side of lock body to be locked: a. Push in latch while gently pushing on catch plate with screwdriver (Fig. 3a). b. Release latch and remove from lock body. c. Turn over latch and re-install in lock body; Be sure anti-friction latch tail hooks into front (Fig. 3c). d. Hold screwdriver behind tail socket while pushing in latch.
ML20700 PWI/PIP Series Mortise Lock 5) Installation Instructions (Continued) 4. Install Lock Body into Door: a. Feed wires through hole on INSIDE of door while installing lock body (Fig. 4a). b. Pull wires through hole while inserting lockbody (Fig. 4b). DO NOT push wires back into cylinder hole. IMPORTANT: Door must remain open during installation. Use door stop. Inside Face of Door EL IM IN AR Y c. Install, but do not tighten two #12 x 1” combination screws through lock body (Fig. 4b). PR Fig.
ML20700 PWI/PIP Series Mortise Lock 5) Installation Instructions (Continued) 5. Install Standard Lever Trim Instructions: Step 1b Step 1a Outsode Face of Door Inside Face of Door IM IN AR Y Outsdide Adapter Plate Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
ML20700 PWI/PIP Series Mortise Lock 5) Installation Instructions (Continued) 5. Install Standard Lever Trim Instructions (continued): Step 4A Step 4B Use Correct Spindle Orientation Inside Face of Door STANDARD Good MUSÉO Bad IN AR Y Lever PR EL IM Step 5 - Align adjustment bolt with threaded hole in lever Adjustment bolt needs to be threaded in farther. Adjustment bolt needs to be unthreaded. Adjustment bolt fully aligned.
ML20700 PWI/PIP Series Mortise Lock 5) Installation Instructions (Continued) 6. Install Lever Trim: Step 1 IN AR Y Unthread hub 1/2 turn then push spindle into lever EL PR Step 2 IM Thread hub into lever using spindle until snug Inside Face of Door Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
ML20700 PWI/PIP Series Mortise Lock 5) Installation Instructions (Continued) 6. Install Trim (continued): Step 3 Outside Face of Door AR Y Set screw in hub faces away from door edge IM IN Inside Face of Door PR EL Step 4 14b. Install Trim: Use the Correct Spindle Orientation STANDARD Bad MUSÉO Good L e v e rLever Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved.
ML20700 PWI/PIP Series Mortise Lock 5) Installation Instructions (Continued) 7. Install Cylinder and Scalp: Step 1 Key and cylinder must be rotated. IN AR Y Incorrect Step 2 PR EL IM 7/64" Allen Wrench Step 3 Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
ML20700 PWI/PIP Series Mortise Lock 5) Installation Instructions (Continued) 8. Install Turn Piece: Step 2 EL PR Step 3 IM IN AR Y Step 1 Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
ML20700 PWI/PIP Series Mortise Lock 9. Install (optional) Weatherseal Gasket: For non-fire rated door applications, an optional gasket may be used as a weatherseal between the escutcheon and the outside door surface. Peel off the adhesive backing on the gasket and install the gasket along the edge of the outside escutcheon assembly (Fig. 9a). Weatherseal Gasket 10. Y Outside Escutcheon Install Inside Mounting Plate: IN Fig.
ML20700 PWI/PIP Series Mortise Lock 5) Installation Instructions (Continued) 12. Install Electronics Module: a. Insert the single tab on the electronics module into the single tab at the bottom of the mounting plate. AR Y b. Tilt the module upward and secure the top two tabs into the mounting plate (Fig. 12a). 13. IM IN Fig. 12a Attach PWI Connectors (For PIP skip to Step 15): EL Secure the following connectors to the circuit board as shown (Fig. 13a and 13b Detail). a.
ML20700 PWI/PIP Series Mortise Lock 5) Installation Instructions (Continued) 14. PWI Battery/ Battery Pack Installation (For PIP skip to Step 15): a. Place (6) “AA” batteries into the compartment being careful to align polarity (- & +) according to case markings (Fig. 13a). AR Y b. Insert battery pack and click into place, making sure polarity terminals on the battery pack are oriented upward (Fig. 13b). Fig. 14b 15. IM IN Fig.
ML20700 PWI/PIP Series Mortise Lock 5) Installation Instructions (Continued) 16. Install Inside Escutcheon: Install escutcheon using two #8-32 T20 Security Torx Screws. PR EL IM IN AR Y Be careful not to pinch wires under escutcheon. Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. 18 Fig.
ML20700 PWI/PIP Series Mortise Lock Important Note: Wiring Installation Y If you are installing PIP (PoE) please go to Page 19 PIP Installation Wiring PR EL IM IN AR If you are installing PWI please go to Page 21 Operational Check Continue With Installation... Copyright © 2011 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
ML20700 PWI/PIP Series Mortise Lock 6) PIP (PoE) Installation Wiring 17. PIP (PoE) Installation Wiring: Frame harness assembly AA. PoE (From McKinney) Door harness* CC. PoE (From McKinney) data hinge (Patent Pending) BB. PoE (From McKinney) 700 PIP (PoE Lock) DD. Access * Order of installation may vary. Refer to appropriate sections for instructions.
ML20700 PWI/PIP Series Mortise Lock 6) PIP (PoE) Installation Wiring (Continued) Frame Harness Installation A Components and wire harness supplied by McKinney: Suggested installation.
ML20700 PWI/PIP Series Mortise Lock 6) PIP (PoE) Installation Wiring (Continued) C Hinge Installation Order of installation may vary. Refer to appropriate sections for instructions. Hinge-side harness connectors: • 4-pin male Molex connector • 6-pin male Molex connector with ground wire Lock-side harness connectors: • Ring terminal • (2) 4-pin connectors: • 4-pin Molex connector • 4-pin connector Y Notes: Connectors go on only one way. They cannot be plugged to incorrect position.
700 TCPWI1/TPIP ™ 7) Operational Check IMPORTANT: Be sure to test functions prior to closing door. In all cases, perform the following checks: 1. Ensure that inside lever retracts latch (and deadbolt for deadbolt functions). • For units with cylinders, the following checks apply: a. There should be no friction against lock case, wire harness, or any other obstructions. If friction or binding occurs, readjust cylinder and wiring harness to eliminate issues. AR b.