Certification Exhibit FCC ID: U4A-SCYICLS1 IC: 6982A-SCYICLS1 FCC Rule Part: 15.247 / 15.225 IC Radio Standards Specification: RSS-210 ACS Project Number: 10-0345 Manufacturer: Assa Abloy Model: N2-IA/IK Manual 5015 B.U.
v.N2 Profile Series v.N2 with Aperio™ Technology Mortise Lock Installation Instructions A8078A 04/11 Copyright 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
Table of Contents 1 2 3 4 5 6 7 8 04/08/11 Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 1 Warning . ..................................................................................2 General Description..................................................................3 Specifications....................................................
Profile Series v.N2 Mortise Lock 2 General Description The SARGENT® Profile Series v.N2 lock with Aperio™ Technology makes it easy and cost-effective to bring access control to additional doors. It uses local wireless communication between the lock and an Aperio hub to connect to an access control system, eliminating the greatest cost and inconvenience of traditional access control – the wiring at the door. The Profile Series v.N2 includes HID® iCLASS® 13.
04/08/11 Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Profile Series v.N2 Mortise Lock 5 Parts Breakdown 13.56 MHz iCLASS 9 8 9 7 4 5 9 5 3 2 10 9 16 12 11 9 7 13 1 4 1-800-810-WIRE • www.sargentlock.
Profile Series v.N2 Mortise Lock Parts Breakdown 13.56 MHz iCLASS (Continued) DESCRIPTION QTY. 1 Outside Lever Reference 8200 Catalog for available levers 1 2 Inside Lever Reference 8200 Catalog for available levers 1 3 82-0495 O/S Escutcheon only with Cylinder 1 82-0493 O/S Escutcheon only without Cylinder 1 82-0492 Inside Escutcheon only without Thumb Turn 1 4 82-0494 Inside Escutcheon only with Thumb Turn 1 5 52-5291 Aperio Electronic Replacement Pack, 13.
Profile Series v.N2 Mortise Lock 6 Lock Installation 1 Prepare Door A. Verify Hand and Bevel of Door Stand on outside of locked door when determining door hand. LH LHRB RH RHRB Left Hand Hinges Left Open Inward Left Hand Reverse Bevel Hinges Left Open Outward Right Hand Hinges Right Open Inward Right Hand Reverse Bevel Hinges Right Open Outward Fig. 1A B. Door Preparation Prior to installation, all holes must be free of burrs, debris and sharp edges.
Profile Series v.N2 Mortise Lock 2 How to Change Hand of Lock body A. Reverse Lock Hand Red surface of locking piece must face the outside/locked side of door. To rotate locking piece (Fig. 2A): 1. Position lock body with red surface of locking piece visible. 2. Insert blade type screwdriver into locking piece slot to rotate locking piece toward back of lock body. 3. Rotate the locking piece 180° until RED surface is on opposite side. Note: Red indicates locked side (outside).
Profile Series v.N2 Mortise Lock 3 Mortise Lock Body DIP Switch Settings NOTE: The DIP switch RX settings located on the rear of the mortise lockbody must be set prior to lock installation. Failure to follow sticker directions will cause inaccurate RX activity to be reported to the access control panel. Set DIP switch for appropriate door application by sliding the DIP switch to the side opposite the red surface of the locking slide. DIP switch Fig.
Profile Series v.N2 Mortise Lock 5 Exterior Door Options A. Fire Stop Plate (P/N 52-0033) Fire-rated doors require a fire stop plate on the outside of the door (Fig. 5A). 1. Drill (2) 1/8” x 1-1/4” deep holes in the door, if not already present. Refer to template for fire-stop prep locations. 2. Attach with flap up and out using (2) #8 x 1/2” self-tapping screws for wood and metal doors. B.
Profile Series v.N2 Mortise Lock 7 Install Outside Escutcheon 1. Attach escutcheons to the door after the wires are connected. Note: The 43 cylinder may be used with or without a gasket. 2A. For fire rated doors: Feed ribbon cable with connector from outside of door through weatherseal gasket and fire stop plate (Fig. 7A). Note: Install ribbon cable with cable exiting down. 2B.
Profile Series v.N2 Mortise Lock 9 Inside Escutcheon Connections Before the controller is attached to the door: 1. Connect the cable from the mortise lock to the bottom of the controller assembly (TB1). 2. Attach the reader assembly ribbon cable into the controller assembly (2). Reader Ribbon Cable 1 Mortise Connector Fig. 9A Inside of Door 10 Install Inside Esutcheon 2. Insert (2) #8-32 x 1-1/4” screws through inside escutcheon and thread into outside escutcheon.
Profile Series v.N2 Mortise Lock 11 Install Inside Lever 1. Slide lever handle onto spindle until fully seated (Fig. 11A). 2. Tighten the set screw securely with 1/8” hex wrench (Fig. 11B). Fig. 11B Fig. 11A Inside of Door 12 Install and Secure Cylinder 1. Slide cylinder through the spring and screw into lockbody, rotating the cylinder clockwise (Fig. 12A). Cylinder should be flush with rosette/collar. Note: The 43 cylinder may be used when installing this product with or without a gasket.
Profile Series v.N2 Mortise Lock 13 Attach Front Plate Attach front plate with (2) flat head screws. Outside of Door Fig. 13A 14 install or Replace Batteries 1. To install or replace batteries, first remove the battery cover (if necessary) using the provided security tool (Fig.14A). 3. Place (6) “AA” alkaline batteries in the compartment, being careful to align polarity properly. Battery Cover Security Tool (01-029) 4.
Profile Series v.N2 Mortise Lock Operational Check 7 For 82276- and 82278-function mortise locks with cylinders: 1. Insert key into cylinder and rotate. There should be no friction against lock case, wire harness or any other obstructions. (Refer to Section -6 Wiring if harness friction exists). 2. Check that the key retracts the latch: The key should rotate freely. 3. Throw the deadbolt: Check that the key retracts both the deadbolt and the latch. 4.
Profile Series v.N2 Mortise Lock Lock LED Indications 1 Lock Normal Operation LED indication The lock has three LEDs that support an optical scheme with red, yellow and green. The indication scheme is described by the figures below: Card read (configurable) One yellow flash (.25 second) Access granted, EAC offline or online One green flash (1 second) Access denied, EAC online One red flash (1 second) Access denied, EAC offline Three red flashes (.
3 Lock Self Test LED Indication After replacing the battery, a Power On Self Test (POST) is performed. The result is indicated using a series of red and green LED flashes as is described by the figure below: One red, one green flash (1 second each) One red flash followed by 16 red or green flashes (.5 s each) Fig. Lock POST LED indication The first flash is always red.