Certification Exhibit FCC ID: U4A-SCYICLS0 IC: 6982A-SCYICLS0 FCC Rule Part: 15.225 IC Radio Standards Specification: RSS-210 ACS Report Number: 11-0125.W06.11.A Manufacturer: Assa Abloy, Inc. Models: TCWI1-M812/M813, TCIP1-M812/M813 Manual 5015 B.U.
Access 800 TM Installation Instructions For ML20800 TCWI1/TCIP1 Series Mortise Lockset FM 335 (Rev. 0 /2011) Please read these instructions carefully to prevent missing important steps. Please Note: Improper installation may result in damage to the lock and void the factory warranty. Important: The accuracy of the door preparation is critical for proper functioning and security of this lock. Misalignment can cause premature wear and a lessening of security.
ML20800 TCWI1/ TCIP1 Series Mortise Lock Table of Contents 1) 2) 3) 4) 5) 6) 7) 8) Warning………………………………………………………………. 1 General Description…………………………………………………. 2 Specifications/ Features…………………………….……………… 2 Product Illustration……………..……………………………………. 3 Installation Instructions……………………………………………… 4-10 Wiring Diagrams…………………………………………………….. 11-17 Mechanical Operation Check ……………………………………… 18 Electrical Operation Check………………………………………….
ML20800 TCWI1/TCIP1 Series Mortise Lock 2) General Description The Corbin Russwin Access 800 Series mortise locks are available in WiFi (WI1) and PoE (IP1) configurations. When coupled with third party software the WI1 and IP1 offer a complete integrated access control system. The Access 800 may be used for both indoor and outdoor applications (weather gaskets supplied).
3) ML20800 Series Product Illustration 3
4) Installation Instructions 1 Verify Hand and Bevel of door. Illustrations shown are as viewed from the outside or secure side of opening. Left Hand Hinges Left. Open Inward. "LH" Left Hand Reverse Bevel Hinges Left. Open Outward "LHR" Right Hand Hinges Right. Open Inward. "RH" Right Hand Reverse Bevel Hinges Right. Open Outward "RHR" 2 Prep door according to supplied Corbin Russwin Inc. door marker. Outside of Door Hole for ribbon cable 7/8" 1/8" Dia.
Installation Instructions 3 Lock Assembly Instructions Align bevel accordingly. Engage 7/64 Allen wrench on to cap screw required for step 2 page 6. Feed connector and wires through 1 (25) dia. wire access hole. Insert lockbody into mortised cutout in door and hold loosely in place with (2) #12x1" lockbody screws.
Installation Instructions 4 Installation of Outside Escutcheon 1. For exterior applications, an optional M99 Weatherseal Gasketing Kit can be ordered when a device is ordered. this kit includes gaskets and a conduit. When ordering the kit separately, order part number 794F929. The gaskets may be used as a seal between the escutcheon and the door surfaces. 2A. For fire rated doors feed ribbon cable connector and ground wire from outside escutcheon through the fire stop plate. 2B.
Installation Instructions 5 Installation of Inside Escutcheon NOTE: Connectors go on only one way. Do not offset connector and be sure they are completely seated. 1. Remove black battery cover from the eschutcheon with High Security T20 Trox bit provided. 2. Connect Ground wire to Ground terminal, Keypad ribbon cable connector to controller, lockbody harness to motor connector, DPS conector on lockbody harness to remote power and DPS harness, and connect remote power if applicable. 3.
Installation Instructions 5 Installation of Inside Escutcheon (continued) CAUTION: Do not allow lockbody harness wires to enter cylinder hole in lockbody. Wire damage and/or malfunction of the lock may occur. 1. Turn inside lever to the horizontal position and rotate the turnpiece to the vertical position. Slide onto spindle halfway.
Installation Instructions 6 Installation of Armored Front Plate 1.Install armored front plate using two #8-32 x 1/4"screws provided.
Installation Instructions 7 Battery Installation 1. Remove battery keeper by lifting top tab and pulling away from the unit. 2. Install (6) AA Batteries into controller compartment being careful to align +/- polarity properly. 3. Install Battery Keeper by first inserting bottom tabs in bottom slots of controller. Lift the top tab over batteries and snap into position. 4. Attach battery cover to inside controller escutcheon making sure to line up tabs with retaining slots in battery cover.
5) Operational Check 8 Lock Operational Check For devices with cylinders: 1. Insert key into cylinder and rotate. (There should be no friction against lock case, wire harness or any other obstructions) 2. The key will retract the latch, key should rotate freely. If the deadbolt is thrown, the key will first retract the deadbolt and then the latch. Inside lever retracts latch and deadbolt, if provided. 3. 8VH 3UR[LPLW\ & DUG RU 3LQ FRGH VHW XS ZLWK /RFN & RQILJXUDWLRQ 7RRO 7KLV VKRXOG XQORFN RXWV
6) ML20800 Hard Wiring Instructions 6.1) Important 1. Caution: disconnect all input power before beginning installation to prevent electrical shock and equipment damage. 2. Installer must be a trained, experienced service person. 3. All wiring must comply with applicable local electrical codes, ordinances and regulations. 6.2) Installation Notes 1.
6) ML20800 Hard Wiring Instructions 6.