FCC ID: U4A-PRXTRMH1 IC ID: 6982A-PRXTRMH1 Report No. M060902_Cert_Rx EMC Technologies Report Number: M060902_Cert_Rx APPENDIX G USER MANUAL EMC Technologies Pty Ltd – 176 Harrick Road, Keilor Park VIC 3042 Australia www.emctech.com.
Installation Instructions For © SARGENT Manufacturing Company 2007 Harmony Series H1 Mortise Lock A7877A 03/07
Table of Contents Page 1 Warning 2 General Description.....................................................1 3 Specifications............................................................1 4 Features ..................................................................1 5 Parts Breakdown .......................................................2-3 6 Installation Instructions ..............................................4-11 7 Operational Check ......................................................
Harmony Series H1 Mortise Lock 2 General Description The SARGENT Harmony Series H1 Mortise Lock is designed to interface with an existing weigand access control system.
Harmony Series H1 Mortise Lock 5 Parts Breakdown 22 2 23 21 20 3 15 24/25/26 31 5 30 8 6 14 27 28 29 34 33 10 1 10 11 12 13 18/19 32 29 16/17 27 28 9 6 7 8 5 4 © SARGENT Manufacturing Company 2007 2 A7877A For installation assistance, contact SARGENT at 800-810-WIRE (9473)
Harmony Series H1 Mortise Lock 5 Parts Breakdown (Continued) ITEM PART No.
Harmony Series H1 Mortise Lock 6 Installation Instructions Verify Hand and Bevel of Door Step #1 – Door Preparation Before Starting Wood door - A7879 template ships with product.
Harmony Series H1 Mortise Lock Step #2 – How to Reverse Lock Hand Note: Red surface of locking piece must face secure side of door. To rotate locking piece: 1. Position lockbody with red surface of locking piece visible 2. Insert blade type screwdriver into locking piece slot to rotate locking piece 3. Push locking piece toward back of lock body and rotate 180° until RED surface shows on opposite side 4. Red indicates locked (outside) side. 5. Wire harness MUST exit thru non-cylinder side.
Harmony Series H1 Mortise Lock Step #3 – Lockbody Installation Wires and connector go into the mortised area and out of the inside cylinder hole Must feed connectors and wires thru non-cylinder side (2)#12-24 x 1/2" long flat head screws for metal doors. Inside of door Step #4 – Inside Mounting Plate Installation (2)#12 x 1=1/4" long flat head wood screws for wood doors. 1. Secure the mounting plate with (4) self tapping screws (#8 x 1/2").
Profile Series H1 Mortise Lock Step #5 – Installation of Outside Escutcheon Reader & Lever Assembly 1. Feed the reader cable connector located on the back of the outside escutcheon from the outside of door through door. 2. Securely tighten the outside escutcheon with (2) through-bolts (#8-32 x 2") Phillips flat head screws with the mounting plate. 3. With outside lever horizontal, insert the mounting post through outside of door and lock body. Make certain the lever spindle is proper engaged in lock. 4.
Profile Series H1 Mortise Lock Step #7 – Installation of Inside Escutcheon Assembly 1. Attach E-Lynx door harness connectors to inside electronic. 2. Feed wires into door pre. 3. Attach inside escutcheon to mounting plate. Note: Be sure not to pinch wires when mounting escutcheon.
Harmony Series H1 Mortise Lock Step #8 – Stallation of the Inside Rose and Inside Lever Assembly 1. Rotate inside rose clockwise. 2. Slide lever handle onto spindle until fully seated. Be sure handle is horizontal and facing to the rear of the door. 3. Tighten the set screw securely with 1/8" hex wrench. Rose Set Screw Inside Lever Spindle Inside of door Step #9 – Installation of Outside Cylinder Fig. 1 Fig. 2 1. Verify orientation of cylinder (Ref. to Fig. 3). 2.
Harmony Series H1 Mortise Lock Step #10 – Application of Front Plate 1. Attach front plate with (2) flat head screws.
Harmony Series H1 Mortise Lock 7 Mechanical Operation Check For 82276 & 82278 Function mortise locks with cylinders: 1. Insert key into cylinder and rotate (There should be no friction against lock case, wire harness or any other obstructions. Refer to Section 6, Step 8 if harness friction exists). 2. The key will retract the latch. Key should rotate freely. 3. If the deadbolt is thrown, the key will retract both the deadbolt and the latch. 4. Inside lever retracts latch and deadbolt (if provided).
Founded in the early 1800’s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices, electro-mechanical products and access control systems for new construction, renovation, and replacement applications. The company’s customer base includes commercial construction, institutional, and industrial markets.