TD 92082GB PRELIMINARY Installation Guide L951LP Locator L951A1 Antenna Unit L951A2 Antenna Unit L951A2/2 Antenna Unit L951PA Power Amplifier L951TP Transient Protection Unit 7 May 2012 / Ver.
Installation Guide LF Location Units TD 92082GB PRELIMINARY Contents 1 Introduction ................................................................................................................... 1 1.1 Regulatory Compliance Statements (EU/EFTA only) ...................................................... 2 1.2 Regulatory Compliance Statements (USA and Canada only) ....................................... 2 2 Board Descriptions .............................................................................
Installation Guide LF Location Units TD 92082GB PRELIMINARY 1 Introduction Figure 1. L951LP Locator, L951A1 Antenna Unit and L951A2 Antenna Unit. The Locator L951LP is a dual output low frequency (LF) inductive location transmitter. It is used in the Ascom Paging System and Ascom IP-DECT System, when location function is required. It generates coded signals to modulate a magnetic field carrier. Alarm Transmitters designed for LF can be used to identify the location from where an alarm is generated.
Installation Guide LF Location Units TD 92082GB PRELIMINARY Tools, etc., required • • • • • • 1.1 Screwdrivers for Phillips and slotted screws Cutting pliers Multimeter a71 Alarm Transceiver, with system test menu enabled Torx bits, (¼” hexagon) TX–25H Torx screw, button head A2 4.
Installation Guide LF Location Units TD 92082GB PRELIMINARY 2 Board Descriptions 2.1 L951LP Locator 1 2 SW04 SW01 SW05 SW02 1 1 8 8 1 2 LED01 SW03 J05 1 P02 J01 6 2 LED03 S04 3 1 Channel 2 S03 3 1 J04 P01 1 S02 3 1 2 LED02 Channel 1 L04 Figure 2. Circuit board L951LP Locator.
Installation Guide LF Location Units TD 92082GB PRELIMINARY Jumpers S02: 1 – 2: When using internal antenna (L04). 2 – 3: When connecting L951PA Power Amplifier or external antenna A1, A2, A2/2, or loops to channel 1. S03: 1 – 2: Channel 2 sends same code as channel 1. 2 – 3: Channel 2 sends code + 1. S04: 1 – 2: When channel 1 only is being used. 2 – 3: When channel 2 is being used. Switches SW01 and SW02: To set the location code. 2.
Installation Guide LF Location Units TD 92082GB PRELIMINARY Connectors J01: Input signal from driver. Jumpers If the tamper protection is to be disabled, a jumper should be placed on pins 1 and 2. If the tamper protection is active, the cover plate must be in place for the Locator to function. S05: Switches SW01: 2.3 Reed relay – for tamper protection L951A2 and L951A2/2 Antenna Units J1 1 2 Figure 4. Circuit board L951A2 and L951A2/2 Antenna Units. Connectors J1: 7 May 2012 / Ver.
Installation Guide LF Location Units TD 92082GB PRELIMINARY 2.4 L951PA Power Amplifier 1 S04 J01 J05 S01 LED01 1 2 2 1 1 1 4 4 1 J06 J03 SW01 Figure 5. Circuit board L951PA Power Amplifier.
Installation Guide LF Location Units TD 92082GB PRELIMINARY 3 Installation The L951LP, L951A1, and L951TP are housed in heavy-duty splash-proof plastic case, L951PA is housed in an aluminium case, and L951A2 and L951A2/2 are for flush mounting. The Power Amplifier (L951PA) and the flush mounted antennas (L951A2 and L951A2/2) have to be mounted indoors. Preferably, all units should be placed indoors, in a dry, room tempered environment. Maximum allowed temperature range is –20°C to +55°C.
Installation Guide LF Location Units TD 92082GB PRELIMINARY 3.1.2 L951A1 Antenna Unit 50 mm Tamper magnet 108 mm Figure 7. Mounting dimensions, L951A1 Antenna Unit. 1 Open the plastic case by removing the four screws on the cover plate. 2 Fasten the back plate of the case on the desired surface with four screws, see figure 7 for mounting dimensions. Mount the case with the cable entry downwards.
Installation Guide LF Location Units TD 92082GB PRELIMINARY 3.1.4 L951A2/2 Antenna Unit Minimum hole diameter for flush mounting 70 30 Depth of circuit board with components Figure 9. Mounting dimensions in mm. The Antenna Unit L951A2/2 is for flush mounting. See figure 9 for mounting dimensions. Fasten the holders to the circuit board. Figure 10. Fastening of holders to L951A2/2 circuit board. Remove the protecting film from the double sided sticky tape and fasten the antenna on the desired surface.
Installation Guide LF Location Units TD 92082GB PRELIMINARY 3.1.5 L951PA Power Amplifier 60 100 138 150 Figure 11. Mounting dimensions for L951PA in mm. 1 Fasten the case on the desired surface with four screws, see figure 11 for mounting dimensions. IMPORTANT: L951PA must be mounted to a vertical wall. No cable entries must be directed downwards. NOTE: When the case of the L951PA are put together, make sure that the reed relay and the tamper protection magnet are placed opposite to each other. 3.1.
Installation Guide LF Location Units TD 92082GB PRELIMINARY 3.2 L951LP Locator 3.2.1 Connecting Supply Voltage 1 2 SW04 SW01 SW05 1 SW02 1 1 2 LED01 8 8 SW03 J05 1 P02 2 LED03 1 Channel 2 1 J04 P01 1 J01 S04 S03 S02 6 3 3 3 1 2 LED02 Channel 1 L04 J01 out Monitor in 16 - 40 V DC 15 - 28 V AC 6 5 4 3 2 1 Figure 13. Connector J01, L951LP Connect supply voltage to pin1 and 2 on J01 as shown in figure 13. 3.2.
Installation Guide LF Location Units TD 92082GB PRELIMINARY See example of the switches in figure 14. Switches 1-4 fourth hex digit (Hex D) Switches 1-4 second hex digit (Hex 3) OFF 1 2 1 ON 1 OFF ON 1 1 4 4 4 5 5 8 8 Switches 5-8 first hex digit (Hex F) 8 SW02 SW01 3 8 Switches 5-8 third hex digit (Hex 5) Figure 14. Example with SW01 and SW02 set to location code F35D.
Installation Guide LF Location Units TD 92082GB PRELIMINARY 3.2.5 Connecting Antenna Units L951LP can feed two Antenna Units. Channel 1 CODE Antenna Unit L951A1, L951A2, or L951A2/2 L951LP Locator Channel 2 CODE or CODE +1 Figure 16. Connection of Antenna Units.
Installation Guide LF Location Units TD 92082GB PRELIMINARY 3.2.6 Connecting Loops L951LP can feed two indoor or outdoor loops. Channel 1 L951LP Locator Outdoor Loops L951TP Channel 2 Figure 18. Connection of Transient Protection Unit and loops. L950TP (Transient Protection) is required when the loops are mounted outdoors. It is mounted between the L951LP Locator Unit and the loop antennas.
Installation Guide LF Location Units TD 92082GB PRELIMINARY 3.2.7 1 Connecting Power Amplifier Connect J04/J05 on L951LP to J01 on L951PA. J01 LED01 J01 1 2 J05 1 2 2 1 1 4 4 1 J06 J03 SW01 1 2 J05 SW04 1 SW01 SW05 1 SW05 SW02 1 2 1 1 2 2 LED01 Channel 2 8 8 SW03 J05 J04 1 1 P02 2 LED03 1 Channel 2 1 2 Channel 1 J04 P01 1 J01 S04 S03 S02 6 3 3 3 1 2 LED02 Channel 1 S04 L04 3 1 S03 3 1 S02 1 3 Figure 20. Overview of Locator and Power Amplifier.
Installation Guide LF Location Units TD 92082GB PRELIMINARY 3.2.8 Adjusting the Range 1 2 SW04 SW01 SW05 SW02 1 1 1 2 LED01 8 8 SW03 - J05 + P02 1 2 1 Channel 2 1 J04 P01 J01 S04 S03 S02 1 6 3 3 3 1 2 Channel 1 L04 Figure 21. P01 and P02 (P02 uppermost), L951LP. The range for channel 1 and channel 2 is set by adjusting potentiometers P01 and P02 respectively. The maximum range for the Locator and Antenna Units are approximately 3 meters. • • 3.
Installation Guide LF Location Units TD 92082GB PRELIMINARY 3.3.2 Connecting Antenna Unit L951PA can feed one Antenna Unit. Loops should not be connected to the Power Amplifier. L951LP Channel 1 CODE or Channel 2 CODE or CODE +1 L951A1, L951A2, or L951A2/2 L951PA Figure 23. Connection of Antenna Unit. The range for the Power Amplifier is adjusted in the Locator Unit, see 3.2.8 Adjusting the Range on page 16. The maximum range for the Power Amplifier is approximately 5 meters.
Installation Guide LF Location Units TD 92082GB PRELIMINARY 3.4 L951TP Transient Protection Unit Connection of L951LP and Loops Outdoors Loop Antennas LINE EQUIP Inside Top Cover L1 L2 L1 L2 b 2 a b 1 a b 2 a b 1 a 2 wires Channel 1 L951LP Channel 2 4 wires 2 wires Channel 1 Channel 2 <_ 1 m <_ 1 m Figure 25. Connection of channel 1 and 2 to L951TP. NOTE: The LINE connector should be connected to the Loop Antenna and the EQUIP connector to the Locator. 7 May 2012 / Ver.
Installation Guide LF Location Units TD 92082GB PRELIMINARY 3.5 Locator Monitoring The monitor output is a galvanically isolated relay contact (< 15 ohm) used for supervision of the locators. The relay contact becomes open circuit (> 1 M ohm) if a fault is detected. It can be a collapse of the magnetic field due to a discontinuity in the antenna loop, or the tamper protection has been triggered.
Installation Guide LF Location Units TD 92082GB PRELIMINARY Depending on the type of Alarm Module and the supply voltage in the monitor loop, the following number of units can be connected to the same input: 3 4 Supply Voltage 12 V DC 24 V DC T941AM32 Max no of units: 2 9 T941AM8 Max no of units: 5 12 Reed relay (SW03 on Locator and SW01 on Power Amplifier) is connected in series with the monitor output. The relay closes if a magnet is placed near to and parallel to it.