TD 92579EN Installation and Operation Manual IP-DECT Base Station and IP-DECT Gateway (software version 7.2.X) 10 April 2015 / Ver.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Contents 1 Introduction............................................................................................................. 1 1.1 Abbreviations and Glossary ................................................................................ 2 2 IP Security ................................................................................................................ 3 2.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 3.13.2 Individual Registration ............................................................................ 23 3.13.3 Easy Registration .................................................................................... 25 4 Operation............................................................................................................... 27 4.1.1 Name the IPBS and IPBL ......................
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 4.5.17 Set Master Id ......................................................................................... 63 4.5.18 Enable PARI Function ............................................................................. 63 4.5.19 Set Region Code .................................................................................... 63 4.5.20 Configure Gatekeeper .......................................
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 4.10.1 Radios ................................................................................................... 84 4.10.2 RFPs ....................................................................................................... 86 4.10.3 Sync Ring ............................................................................................... 89 4.10.4 Sync Ports ...............................
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 4.28.1 Idle Reset ............................................................................................. 120 4.28.2 Immediate Reset .................................................................................. 120 4.28.3 TFTP Mode .......................................................................................... 120 4.28.4 Boot ...................................................
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 1 TD 92579EN Introduction This document describes commissioning and administration of the following equipment: • IPBS 1 • IPBL 2 The document is intended as a guide for the System administrators: For information on the IP-DECT system, see the System Description documentation for IPDECT. For information about supported PBXs contact your supplier. 1.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 1.1 TD 92579EN Abbreviations and Glossary Base Station Common name for IPBS, DECT Base Station (BS3x0) and TDM-DECT Base Station. DECT Digital Enhanced Cordless Telecommunications: global standard for cordless telecommunication. DECT Base Station Another name for BS3x0 TDM-DECT Base Station Another name for DB1.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 2 TD 92579EN IP Security 2.1 IP Security Terminology 2.1.1 TLS (former SSL) Note: Secure Socket Layer (SSL) has been renamed Transport Layer Security (TLS). TLS 1.0 is based on SSL 3.0/3.1. This document hereafter uses the term TLS. TLS is a security mechanism based on cryptography (see 2.1.3 Cryptography) and is used for encrypting communications between users and TLS-based Websites.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Cryptography tasks can be divided into the two general categories Encryption and Authentication. Encryption Encryption is the scrambling of information so that the original message cannot be determined by unauthorized recipients by applying an encryption algoritm to the message plaintext producing ciphertext (appearently random bits).
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 2.2 TD 92579EN Introduction to IP Security in IP-DECT A secure system requires more planning than an unsecured system. 2.2.1 Secure Web Access (https) For IP-DECT devices • https access should be enabled • http access should preferably be disabled For more information see 4.8.3 Configure the HTTP settings on page 78 . 2.2.2 TLS Certificates Security in Web-based applications rely on cryptography.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN enterprise CA, enabling them to sign (approve) their own certificate requests. This would make the customer a private CA. - B) Certificates signed by a trusted public third party entity/organization. There are only about a dozen issuers who have the authority to sign certificates for servers worldwide. An example is VeriSign.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 2.3 TD 92579EN IP-DECT Administrative Functions 2.3.1 Configuration - HTTP The HTTP tab is used to configure the type of web access that should be allowed for the device, includes a field for configuring https access. For more information see 4.8.3 Configure the HTTP settings on page 78. 2.3.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 3 TD 92579EN Configuration This section describes how to configure the IPBS and IPBL using the web interface. The recommended order to configure the equipment in the IP-DECT system is as follows: 1 Configure the Mobility Master, see 3.4 Configure the Mobility Master on page 16. 2 Configure the Standby Mobility Master, see 3.5 Configure the Standby Mobility Master on page 16.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Note: If the GUI cannot be accessed with Internet Explorer 8 or newer, check that the TLS 1.0 option is activated in the web browser under menu Tools > Internet Option > Advanced > Use TLS 1.0. 3.2.1 Determine the IP Address The factory setting of the DHCP mode for the LAN1 port is "automatic", at first power up it will act as a DHCP client.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Note: In order to determine the IP address it is necessary that the computer is connected to the same LAN (broadcast domain) as the IPBS/IPBL. Determine the IP address following the steps below: Note: If the IPBS/IPBL has been used before, it must be restored to factory default settings by performing a long hardware reset, see 4.29 Reset Using the Reset Button on page 120.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 3 Enter user name and password in the dialog box. Default user name is: admin. Default password is: changeme. 4 Enter a user name in the User Name text field. 5 Enter a password in the Password text field. Repeat the password in the second text field. 6 Click "OK". 10 April 2015 / Ver.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 3.3 TD 92579EN GUI Web Access 3.3.1 Login Page When accessing IPBS/IPBL through a web browser the initial page is the login page. This page has two hyperlinks: System Administration and User Administration. NOTE: Logging out of the IPBS/IPBL application is done by closing the web browser, to be completely logged out. 3.3.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN User administrators can only administer users. They can view but not create or manage other user administrator accounts. Login as User Administrator To login as a user administrator: 1 Follow 3.2 Access the GUI on page 8 and access the device using a web browser. 2 Click the link labelled User Administration. A login window is opened. 3 Enter user name and password for a user administrator.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 3 Enter user name and password for a system administrator. 4 Click "OK" to login. TD 92579EN Following tasks can be done: •Managing the default system administrator account, see The Default System Administrator Account on page 14. •Managing additional system administrator accounts, see Additional Administrator Accounts on page 14.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 3 TD 92579EN On an existing account row in the Users section: • • • • 4 Enter a new user name Enter a new password Enter the password again Select Administrator (for System Administrator) or Auditor in the drop-down list (See 3.3.2 Access Levels on page 12 for a description of access levels.) Click "OK". The account row is updated.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 5 Select/Edit any of the following settings: • • • • 6 TD 92579EN Long Name Name (NOTE: This field is used for login) Password Confirm Password Click "OK". Delete a User Administrator 1 Login as System Administrator (see 3.3.5 System Administrators on page 13). 2 Select "Users". 3 Click "show". 4 In the User Administrators section, click the hyperlink to be deleted below the Long Name heading.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 3.6 TD 92579EN 3 Set a static IP address and set DHCP to off, see 4.2.2 Set a Static IP Address on page 44. 4 Set the mode to Standby Mobility Master, see 4.5.24 Select Mobility Master Mode on page 68. 5 Enter the Primary Mobility Master IP address, see 4.5.24 Select Mobility Master Mode on page 68. 6 Enter a login name and enter a password, this must be the same as in the Primary Mobility Master.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 3.7 TD 92579EN 21 Connect to a Mobility Master, see 4.5.28 Connect Master to a Mobility Master on page 69. 22 Assign PARI, see 4.5.32 PARI on page 70. 23 Enter SARI, see 4.5.33 SARI on page 71. 24 Enter IMS3/Unite CM IP address, see 4.7.1 Configure Messaging on page 74. 25 Enter the Time Server address, see 4.1.4 Configure the NTP Settings on page 37.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 3.9 TD 92579EN 1 Determine the address and access the GUI, see 3.2 Access the GUI on page 8. 2 Change the default password, see 3.2.2 Change the Default Password on page 10. 3 Note: This step is not needed if the Master is configured as Mirror. In that case, jump to the next step. Configure LDAP user name and password, select the Write Access check box, see 4.4.1 Configure LDAP Server on page 48.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 8 Select supplementary services, see 4.5.15 Configure Supplementary Services on page 60. 9 Set Master Id, see 4.5.17 Set Master Id on page 63. 10 Enter gatekeeper address, see 4.5.20 Configure Gatekeeper on page 63. 11 Connect to a Mobility Master, see 4.5.28 Connect Master to a Mobility Master on page 69. 12 Enter IMS3/Unite CM IP address, see 4.7.1 Configure Messaging on page 74.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 3 Reset in order to make the configuration changes take effect, see 4.28 Reset on page 119. 4 Repeat step 1 to 3 for all Radios. 3.12 Configure Deployment This section describes how to configure an IPBS for deployment used for coverage test of air sync and speech. NOTE: For coverage test of air sync, two IPBSs must be configured, one as Sync Master and one as Sync Slave.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN The IPEI is automatically associated to the user, see 3.13.1 Anonymous Registration on page 22. • Individual Registration can be used if a few new handsets shall be added to the IPDECT System. The IPEI is entered manually, see 3.13.2 Individual Registration on page 23. • Easy Registration can be used if many users shall be added to the IP-DECT System.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Assign Handsets to Users 1 Select DECT > System. 2 In the Subscriptions drop-down list, select "With System AC" to enable anonymous registration. Click "OK". 3 Perform an "over air subscription" using the system Authentication Code. For information on how this is done, see the reference guide of the handset. The handset IPDI number appears in the Anonymous list.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Auth Name (SIP) Auth name is the Authentication name used in SIP authentication. If it is not set the number will be used as authentication name. If SIP authentication is used or not is decided by the configuration in the IP-PBX. 60 Password Optional, is used for registration towards the gatekeeper.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 3.13.3 Easy Registration Easy Registration is done in two steps. First, the users are registered in the IP-DECT System through an import of a csv file. Second, the handset is assigned automatically to the user from the handset. Add users in the IP-DECT System If many users should be added it is possible to import a csv file with the IPEI / IPDI. Field name Description Max.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Limitations • Maximum 1000 rows in the csv file. • The maximum csv file size is 128 Kb. If the file is to large, divide the file into several files. • Only the new user data is imported. The old user data is not deleted. • Existing user data cannot be updated. • If the separator is wrong an error message will be displayed.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 4 TD 92579EN Operation This section describes the settings in the Configuration and Administration menu, each subsection represents a sub menu to the Configuration and Administration menu. Some changes require a reset in order to take effect. It is possible to do several changes before resetting the IPBS/IPBL. The GUI for the IPBS and IPBL are similar. Screen shots from the IPBS are used as default. 4.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 4.1.3 TD 92579EN Centralized Management of Administrator and Auditor Accounts Using Kerberos In software version 3.X.X, each IPBS/IPBL had their own set of administrator/auditor accounts.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) Role 7 TD 92579EN • Administrator: Write access to all device parameter settings. • Auditor: Read access to device parameter settings. • Join Realm: Add devices to the realm. Is used only to add or remove devices in the realm. This role cannot be used to login to the GUI. Click "OK".
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 2 Click on the blue text link "Join realm" in the Delegated Authentication section. 3 In the Join Kerberos realm window, enter the following in the text fields: Realm: Enter the realm name of the Kerberos server. Host name: The MAC address of the device. Default value is used.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN (recommended). Enable AES and RC4: Select the Enable AES and RC4 check box. Overwrite existing: Select the Overwrite existing check box (optional). 5 Go to the Authentication Servers section. 6 In the Realm/Domain text field, enter the realm name specified in the Kerberos server. 7 In the Address text field, enter the IP address of the Kerberos server. In the Kerberos server enter 127.0.0.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN • Make sure that the device has been configured as a client in the system, see Set up the client on page 29. • Make sure that the AES and RC4 encryption types are enabled. Select General > Admin and select the Enable AES and RC4 check box. AD server configuration for Windows 2008 R2 servers: The trust relationship must be configured in the AD server. 3 Connect to the Windows 2008 R2 server.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 14 Click "Next". 15 Click "Finish" 16 Click the Trusts tab. Select the realm that you have established a cross realm trust with and click "Properties...". 10 April 2015 / Ver.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 17 Select the The other domain supports Kerberos AES Encryption check box. 18 Click "OK". On IPBS1, IPBS2 and IPBL (the Kerberos server): 19 Select General > Kerberos. 20 In the Trusted realms section and the Name text field, enter the name of the realm of the AD server (see step 9). Must be capital letters. 21 In the Password text field, enter the password entered in step 13.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 23 TD 92579EN Note: This step is only applicable if "Use domain group" is selected in the Authorization drop-down list, see above. In the Admin Group RID text field, specify the Relative Identifier (RID) of a Windows group with administrator rights. In the Auditor Group RID text field, specify the Relative Identifier (RID) of a Windows group with auditor rights.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 26 In the Authentication Servers section and the Realm/Domain text field, enter the realm name of the AD server (see step 9). Must be capital letters. Note: This has not to be done if a DNS server has been configured to be used in the IP-DECT system. In this case the clients will look up the needed information automatically. 27 In the Address text field, enter the IP address of the AD server.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Delete a user or trusted realm To delete a user account from the Kerberos server do the following: 1 Select General > Kerberos. 2 In the Users section select the Delete check box for the user to be deleted. 3 Click "OK". To delete a trusted realm relationship from the Kerberos server do the following: 1 Select General > Kerberos.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Figure 4. Configure NTP settings 1 Select General > NTP. 2 Enter the IP address to the primary NTP server in the Time Server text field. 3 Enter a time interval in the Interval (min) text field. 4 Select time zone in Time zone drop-down list. If the desired time zone is not in the list, select “Other” and edit the String text field following the instructions in the next step.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Trust List A trust list is set up when the device must know which third parties (for example IP-PBX) it shall trust in. The list contains the certificates to be accepted by the device for TLS secured connections (for example HTTPS, SIPS). The following table describes the different functions.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) Upload TD 92579EN Use the Upload function to upload a certificate file to the device. 1 Click the Browse button 2 Select a certificate file 3 Click the Upload button to upload the file to the device. Rejected Certificates This list contains the certificate chains that were rejected before, while trying to establish a secure TLS connection.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) Upload TD 92579EN Use the Upload function to upload a certificate file to the device. 1 Click the Browse button 2 Select a certificate file 3 Click the Upload button to upload the file to the device. NOTE: The Upload function requires a previously issued CSR to exist. Default Device Certificate This section corresponds to option 1 in 2. Certificate Handling Options with Device Certificates on page 5.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Key Select either the desired key strength (1024-bit, 2048bit, 4096-bit) or select to reuse the old key pair (this is not recommended). Signature Select which signature that shall be used for the certificate. Following signatures can be selected: SHA1, SHA256, SHA384, SHA512. The last three ones are SHA2 variants. Validity Enter the default validity in years. This is a mandatory field.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 5 TD 92579EN Click “OK”. The windows closes. A key pair and a CSR file will be created. This may take up to one hour depending on the key strength selected. During this time the device will be fully operational with the exception of https not working and the certificate tab pane not being visible. When the CSR file has been generated it is visible in the Signing Request section of the Certificates page.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) • • • • • TD 92579EN Set link type Configure VLAN Enable RSTP (only for IPBL) View LAN statistics Deactivate LAN port (only for IPBL) Note: The IPBL has two LAN ports. LAN1 port must be used in the IP-DECT system (LAN2 port is for administration only). This is not applicable when RSTP is used, see 4.2.7 Enable RSTP (only for IPBL) on page 45.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 6 TD 92579EN Enter "IP Address", "Network Mask", "Default Gateway" and "DNS Server" addresses provided by the network administrator in the text fields. You can also enter an alternative DNS Server in the Alt. DNS Server text field and select the Check ARP check box to detect and prevent ARP poisoning attacks. 7 Click “OK”. 8 Reset in order to make the changes take effect, see 4.28 Reset on page 119.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN traffic may change whenever the network topology changes, i.e. when a link between bridges goes down or up or a bridge is added. On each such change the IP stack is moved to the selected port without disruption of data traffic. Before RSTP can be enabled the following preconditions must be met: • • • • • • • • • The bridges in the network should support RSTP.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 4.3 TD 92579EN IP 4.3.1 Configure IP Settings The following settings can be done in the IP settings sub menu: ToS priority, RTP Data and VoIP Signaling: Determines the priority from the ToS field in the IP header. This function can be used if the router can use ToS priority control. Hexadecimal, octal or decimal values can be used; 0x10, 020 and 16 are all equivalent.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 4.4.1 TD 92579EN Configure LDAP Server The IP-DECT system needs an LDAP server in some configurations. If the VoIP gateway is set up as an LDAP server, the Master should be set up as an LDAP replicator, see 4.4.3 Configure LDAP Replicator on page 48. Setup the IPBS/IPBL as an LDAP server Note: The selected user name and password must be the same in both the Master and the Standby Master.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN • User data is replicated from the PBX to the Master. The replicator is configured on the Master (Full Directory Replication) Configure Full Directory Replication 1 Select LDAP > Replicator. 2 Select "Full Replication" in the Type drop-down list. 3 Select the Enable check box. 4 Enter the IP address to the LDAP server in the Server text field.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 6 TD 92579EN Enter an LDAP filter to retrieve only the relevant LDAP objects from the AD. A default (objectclass=user) filter is offered, but it is recommended to assign all IPDECT users to a group within the AD. For example, the following filter can be entered to retrieve only IP-DECT users.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN IP-DECT designator IP-DECT attribute name AD attribute name Description Long Name cn cn Mandatory, the name of the user, need to be unique throughout the system. Display Name Idle Display dn displayName, givenName, sn Display Name: First name or surname Idle Display: Optional, will be shown in the handset display when the handset is idle.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN If there are several in maps for one attribute, all maps are handled in the order of appearance. To change the order of appearance click the "Move Up" or "Move Down" icons on the left side of the In Maps window. Out Maps Out Maps define how the local temporary variables configured for In Maps are assigned to the internal IP-DECT attributes.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Configure AD Server The IP-DECT system supports only simple binding authentication. However, the default registry setting for Microsoft Active Directory 2003 does not allow simple binds, so it may be necessary to change Windows Registry settings to use AD replication. 1 In Windows, select "Run..." in the Start menu. 2 Enter "regedit" and click "OK" to start the Windows Registry Editor.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 4.4.4 TD 92579EN Check LDAP Replicator Status 1 Select LDAP > Replicator-Status. The following information is displayed: • Server - The IP address and port of the LDAP server. • Active Directory Replication - Current state of replication. Four states are possible: Stopped, Starting, Up, Down • Remote - State of replication in the source directory.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) • • • • • • 4.5.1 TD 92579EN Enable/Disable Radio Enter IP address to the PARI Master and the Standby PARI Master Multiple Radio Configuration Assign PARI Enter SARI Configure Air Synchronization Change System Name and Password Note: This is only applicable for a Master, never on a Slave. The system name and password must be the same for all IPBS/IPBLs throughout the system.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 1 TD 92579EN Select DECT > System. Note: To access the System tab, the Master mode has to be activated, see 4.5.16 Select Mode on page 62. 2 Enter an authentication code in the Authentication Code text field. 3 Click "OK". 4.5.4 Select Tones 1 Select DECT > System. NOTE: To access the System tab, the Master mode has to be activated, see 4.5.16 Select Mode on page 62.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 1 TD 92579EN Select DECT > System. NOTE: To access the System tab, the Master mode has to be activated, see 4.5.16 Select Mode on page 62. 2 Select/clear the Enabled Carriers check boxes. Note: For Brazil, the following carriers shall be selected only: 0, 1, 2 and 3. 3 4.5.8 Click "OK". Local R-Key Handling With this option enabled keypad information is handled locally.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN handset D’s display depending on if the feature "Display Original Called" is enabled or not. • Display Original Called is enabled: The extension number or name of handset B will be shown in handset D. • Display Original Called is not enabled: The extension number or name of handset C will be shown in handset D. Note: In both cases the extension number or name of handset A will be shown as well.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 6 TD 92579EN To view a list of DECT handsets where early encryption is in use: Select Users > Users and then click "Show". Those DECT handsets where early encryption is in use is indicated with a dot in the column EE (Early Encryption). 4.5.13 Configure Coder Select the preferred coder, and enter the desired frame length. If exclusive is selected for the coder the IPBS/IPBL is forced to use that coder.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN • IPBL: 50 RTP • IPBL: 40 SRTP 4.5.15 Configure Supplementary Services The supplementary services determine how to handle a call if for example busy or not answered by the user. 1 Select DECT > Suppl. Serv. NOTE: To access the Suppl. Serv. tab, the Master mode has to be activated, see 4.5.16 Select Mode on page 62.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Feature Description Call Service URI Is used to initiate some of the features in the CCM. The local feature code is translated to a CCM default "Services URI". Default feature code is: *5$(1). For information about feature codes for Call Service URI, see Configuration Notes, Cisco CallManager in Ascom IP-DECT System, TD 92424GB.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Feature Description External Idle Display Depending on type of IP-PBX, absence and call forwarding texts will be displayed on the handset when idle. Note: If call forwarding is handled by the IP-PBX, the following options must be disabled: Call Forwarding Unconditional Call Forwarding Busy Call Forwarding No Reply 3 Click "OK". 4 Reset in order to make the changes take effect, see 4.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 4 If you have selected the "Mirror" mode enter the IP address to the other Mirror Master in the Mirror Master IP address text field. For the Master that initially shall be the active Mirror: Click on the text link "Activate mirror". Any user and handset data in the inactive Mirror will be replaced with the user and handset data stored in the active Mirror.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 4 TD 92579EN Enter the address to the alternative gatekeeper in the Alt-Gatekeeper IP address text field. NOTE: As an alternative to the Gatekeeper IP Address, the Gatekeeper ID can be used.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN you need to restart all the devices where you made changes (i.e. probably the whole system). 11 To enable "Enbloc Dialing", select the Enbloc Dialing check box. With this option enabled the keystrokes on the handsets are buffered in the IPBS/ IPBL for a short period of time before sent to the IP-PBX (use this when the IP-PBX does not support overlap sending).
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN To enable this option, select the "Accept inbound calls not routed via home proxy" check box. Register with number If this option is enabled, number will be used for registrations towards the IP-PBX instead of name. Name will be used for authentication. To enable this option, select the "Register with number" check box.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 2 Enter the registration name and number to the PBX in the Registration Name / Number text fields. 3 Select the "Deactivate Master if no connection" check box to make the Master deactivate itself if the anonymous registration to the PBX fails. As a result the local host Radio will fail to register to the Master, and handsets, depending on their type, can move to another Radio that is operable.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 4.5.24 Select Mobility Master Mode In a system with two or more Masters (Multiple Master system), a Mobility Master must be configured. For more information on Multiple Master Systems, see the System Planning documentation for IP-DECT. 1 Select DECT > Mobility Master. 2 Select in the Mode drop-down list: • "Active", if this IPBS/IPBL is the Mobility Master.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 2 In the Crypto Master section: Enter the name for the Crypto Master in the Name text field. 3 Enter the password for the Crypto Master in the Password text field. 4 Enter the address to the Crypto Master in the IP Address text field. 5 Click "OK". 6 Repeat the above steps to connect additional Mobility Masters to the Crypto Master.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 7 TD 92579EN Reset in order to make the changes take effect, see 4.28 Reset on page 119. 4.5.31 Multiple Radio Configuration The PARI Master can configure the same Radio settings for all Radios in the system. All settings configured in the Radio Config page replace the local Radio settings.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Note: The RFPI, which the PARI is a part of, can be used for localization of a handset making a personal alarm. To ensure that RFPIs are system unique, use different System ID’s for each PARI Master. 4.5.33 SARI The SARI is the broadcast identity, which uniquely identifies an IP-DECT system. The SARI is added in the PARI Master. It is possible to add more than one SARI (guest SARIs).
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN internal synchronization in respective region will still work but there can be no handover between the regions. Note: For the synchronization to work, it is not allowed to configure reference sync in a ring. Configure Sync Slave IPBS All IPBSs in sync slave mode sends its list of sync candidates to the PARI Master.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 4.6 TD 92579EN 5 Select type of resynchronization action to perform at reference sync failure, a manual or an automatic (scheduled) one. 6 Click "OK". VoIP This section only applies if the SIP protocol is used in the system. 4.6.1 Add instance id to the user registration with the IP-PBX This might simplify administration with some IP-PBXs. 1 Select VoIP > SIP.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 4.7 TD 92579EN UNITE 4.7.1 Configure Messaging Note: The Unite CM support for the below functions is depending on the Unite CM software version. If an IMS3/Unite CM is to be used in the IP-DECT system, enter the IP address following the steps below. 1 Select UNITE > SMS. NOTE: To access the SMS tab, the Master mode has to be activated, see 4.5.16 Select Mode on page 62.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 2 TD 92579EN Select the Encryption check box. NOTES: a) When selecting or clearing the Encryption check box, it may take up to a couple of minutes until the IMS3/Unite CM is fully operational. b) The IMS3/Unite CM support for encryption is depending on the IMS3/Unite CM software version. 3 4.7.2 Click "OK".
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 2 TD 92579EN Do one of the following: • To stop the Master to search for a Device Manager, select the Disable check box. • To set the Master to search for a Device Manager in a specific domain on the network, enter the domain id in the Domain ID text field. The domain id must be the same as the one entered in the Device Manager. 3 Click "OK".
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 4 TD 92579EN Click "OK". The Current Update Serials section shows the values of the variables set after the last execution of the associated command. 4.8.2 Configure Logging There are three ways to collect logs, see the table below. TCP The syslog entries are transmitted using a TCP connection.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Example: Enter the value “/cdr/ cdrwrite.asp” in the “URL-Path” field if a page is on the web server with the name “/cdr/cdrwrite.asp” with a form that expects the log message in the “msg” parameter. In this example, the IPBS/IPBL will make a GET /cdr/ cdrwrite.asp?event=syslog&msg=logmsg request to the server.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 1 TD 92579EN Select Services > HTTP • Select the Force HTTPS check box to allow only HTTPS sessions and all HTTP requests are redirected as HTTPS requests. • Select the Disable HTTP basic authentication check box to require all administrative and programmatic clients to support HTTP digest authentication. • Select the Password protect all HTTP pages check box to password protect all HTTP pages.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Figure 7. Configure SNMP Settings 1 Select Services > SNMP 2 Enter a name in the Community field if you are not using the standard community name (public). The community text string acts like a password to regulate access to the agent on the Base Station. 3 Enter a device name in the Device Name field. This field is optional and serves only informational purposes.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Central Phonebook by Replication from other Master on page 81. Note: If the phonebook functionality in the IPBS/IPBL is enabled, then the SMS feature in the IMS3/Unite CM is disabled. If an IMS3/Unite CM is connected, the central phonebook should be located in the IMS3/Unite CM instead of the IPBS/IPBL.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN To check the replicator status, select LDAP > Replicator-Status. See also 4.4.4 Check LDAP Replicator Status on page 54. Export the Central Phonebook to a csv file The complete phonebook can be exported to a csv file for example for editing or backup reasons. 1 Select Services > Phonebook. 2 Click “Export”. 3 Click “Download file” in the window that appears.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 14 TD 92579EN Click "OK". To activate presence Presence can be activated from a DECT handset or from an operator desk. To activate from a DECT handset the user is entering key pad data for activation of presence, for example *23*3*1500#, where "3" is the reason code and "1500" is the back time.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Add a User to Another IP-DECT System To allow handsets to identify the system to which the subscription shall be directed (e.g. the same physical area may be covered by different systems), it may be necessary to enter an initial PARK into a handset. To view the PARK and the PARK 3rd pty code: 1 Select Users > Users. PARK: Must be used for Ascom handsets.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 1 TD 92579EN Select Device Overview > Radios. Name The unique identification name. The name syntax is ipbs-xx-xx-xx (IPBS1), ipbs2-xx-xx-xx (IPBS2) or ipbl-xx-xx-xx (IPBL), where xx-xx-xx should be replaced with the last 6 hexadecimal digits of the MAC address. RFPI Radio Fixed Part Identity. IP Address The IP address, click on the IP address to access the configuration GUI of that IPBS/IPBL.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 3 In the Add Radio window enter a name for the device. You can also add a Standby Master IP Address and a Sync Region. 4 Click "OK". 5 The Radio restarts and it establishes a connection to the PARI Master only. Delete Radios In the Static Registrations section, initialized Radios no longer registered to the PARI Master are shown.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Boot RFP boot version. Connected Time The elapsed time since the RFP connected to the IPBL. Cable Delay The delay caused by the cable. Tx Error The number of required retransmissions. The counters "Tx Error" and "Rx Error" are indicators of how many packets that did not receive an acknowledge and had to be retransmitted.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Note: The log can only be downloaded once. It is removed from the RFP after download. Logs are stored in the volatile memory and will be lost if the RFP loses power for whatever reason. Figure 8. Figure 9. 10 April 2015 / Ver.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Figure 10. Halted Logs At certain major events, such as an unexpected restart, the logging will be halted so that the major event can be investigated. When the logging has been halted, the blue RFP link on the RFP overview (Device Overview > RFPs) will turn red (see Figure 11). The logging will be restarted after the log has been downloaded.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN A wire map of the synchronization ring is available in the GUI. The identities (IPBL-xx-xx-xx) of the IPBLs and the position in the ring is displayed. If the ring is broken it is possible to locate where. Click the IP address to access another IPBL. 1 Select DECT Sync > Sync Ring. 4.10.4 Sync Ports This section only applies to the IPBL. Displays the current status of the synchronization ports.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN There are five reasons for when the sync lost counter is incremented: • The IPBS has not been able to find a synchronization source within 9 minutes. • The PSCN value is changed. • The value for frame number is changed. • The value for multi frame number is changed. • The number of enabled carriers is changed.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Figure 12. The sync trees for region 0, 1 and 2 where region 0 is fully expanded. Region Details 1 Select DECT Sync > Air Sync Overview. 2 Click on the region ID text at top above the sync tree. 3 If this has not already been done: In the Region Details window, enter a name for the region.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN IPBS Details 1 Select DECT Sync > Air Sync Overview. 2 Click on the "Details" text link above the sync tree. The sync tree will now display name and sync lost counter for the IPBSs in the region. The sync lost counter is a counter that is incremented when the IPBS stops to handle radio traffic for a while and after that restarts the synchronization procedure. 4.11.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Calls In The total number of incoming calls to the Master. Calls In Delivered The number of connected incoming calls in the Master. Calls Out The number of outgoing calls from the Master. Handover The number of handovers in the Master. Handover Cancelled The number of cancelled handovers in the Master. Occurs when the handset decides to stay on the original Base Station.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 4.13.1 General 1 Select Gateway > General. 2 Select/Enter following settings. 3 Field name Description Gatekeeper ID The Gatekeeper Identifier. This is used with VOIP interfaces (GWn) configured as "Gatekeeper/Registrar" as Gatekeeper Identifier (H.323) or Registrar Name (SIP), see 4.13.4 Gatekeeper Interfaces on page 99.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 3 TD 92579EN Select/Enter following settings: Field name Description Name Enter a name for the SIP interface Disable Select the Disable check box to disable the Interface ID Enter the registration ID followed by the SIP provider domain name preceded by an @ (for example 8111111e0@sipgate.de). Proxy The IP address of the SIP provider to where the SIP messages (REGISTER,INVITE,etc.) are to be sent.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Silence Compression Select this check box to enable silence compression. Exclusive Select this check box to accept only preset coders. Local Network Coder Select the preferred coder in the drop-down list for a local network address. Enable T.38 Select this check box to enable T.38 Fax-over-IP protocol. Enable SRTP Select this check box to enable encrypted media streams.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Identity Header when Sending INVITE Interoperability option for outgoing calls. This controls the way CGPN is transmitted to the SIP provider. Possible values are: - CGPN is user part of URI - The Identity header contains an URI with the calling party number as user part (left from @). - Fixed AOR - The Identity header contains the fixed registration URI (AOR).
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 4 TD 92579EN CGPN out If you want to edit the calling number of outgoing calls. CDPN in If you want to edit the called number of incoming calls. CDPN out If you want to edit the called number of outgoing calls. On each mapping line, a Call Number Type can be selected from the Call Number Type drop-down list (found on the righthand side of the lines). NOTE: This step is optional.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN • Third-party VoIP Gateway, as a gateway to telephone switches or, for example, into the SS7 network • Further gatekeepers for call control • VoIP PC programs Each Gatekeeper interface defines access to a group of devices, which are all treated similarly. This allows, for example, all VoIP devices at one location to be configured via a single Gatekeeper interface.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Mode Select one of the values below in the Mode drop-down list. Possible values are: - Gateway without Registration - connects to the VoIP interface (gateway) to the configured gatekeeper without a registration. - Register as Endpoint - registers as VoIP terminal with the configured gatekeeper. - Register as Gateway - registers as VoIP gateway with the configured gatekeeper.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) Supress Subaddress 4 TD 92579EN Suppresses the transmission of “Subaddresses” on the interface. Click “OK”. Call Number Mappings Call number (CGPN/CDPN) mappings are described in Call Number (CGPN/CDPN) Mappings on page 98. 4.13.5 Routes – Configuration Call routing determines which calls are able to be accepted by the gateway and where they are to be switched. 1 Select Gateway > Routes.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) Number out Name out 117 Number in TD 92579EN 3 Select the check boxes of the VoIP interfaces in the left area, to mark them as valid sources for this route. Select interfaces which have been configured. 4 In the drop-down list in the right area, select the destination to which the calls are to be connected. Select interfaces which have been configured.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Leave all the remaining fields blank, in the normal case. Final Route Enable if the routing shall stop here Final Map Enable if the mapping shall stop here. No Reroute on wrong No Enable if you don’t want to reroute when call fails due to wrong number. Verify CGPN Map will match only if there is a matching CGPN map too.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 2 TD 92579EN For the interface, that you want to add a CGPN map, click the “->” sign under the CGPN map heading. A new window opens. Figure 13. Number In – Number Out 3 Under “Number in” define the number type and –prefix that you wish to have replaced. The number type is denoted using the abbreviation from the Call Number Formats Table (see Call Number Formats Table on page 99).
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) Interfaces sif:cgpn:cgnm >dif:cdpn:cdnm/ ccn TD 92579EN Sif: Interface for incoming call. Cgpn: calling number, before routing. Cgnm: calling name before routing. Dif: Interface for the outgoing call. Cdpn: called number after routing. Cdnm: called name after routing. ccn: Name of the call counter used for this route (call counter name).
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 3 Click "Save" in the dialogue window and browse to the place where the configuration should be saved. 4 Click "Save". 4.15 Software Upgrade The RFP version information is not displayed in the IPBS2 GUI. RFP software is more integrated now and this information becomes obsolete. In IPBS1 the RFP software has a separate flash memory, but this is not the case for IPBS2.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN When upgrading from software version 2.X.X to later: Update configuration of Master, see 4.15.5 Configuration After Updating the Firmware From Software Version 2.X.X to Later. When upgrading from software version 3.X.X to later: Update configuration of Master, see 4.15.6 Configuration After Updating the Firmware From Software Version 3.X.X to Later. 4.15.3 Software Upgrade from 2.X.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Master/Standby Master Configuration For both Master and Standby Master, do as follows: 1 If the Radio is activated, select DECT > Radio and enter the name and password for the Pari Master in the Name and Password text fields. 2 For Standby Master only: Enter the address to the Master in the Primary Master IP Address text field.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 3 TD 92579EN Write down each accounts configuration data such as the user name, password (when known) and role. Step 2: On the Kerberos server, do as follows: 1 Select General > Kerberos Server. 2 Go to the Users section and enter the configuration data for each account that was written down in step 1 above. 3 Click "OK".
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Note: If there is a need to activate LLDP for the Base Station again, use the following HTTP command: !config rem LLDP0 /disable 4.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 1 Select Update > Config. 2 Click "Browse..." and browse to the saved configuration. 3 Click "Upload". 4 Reset in order to make the changes take effect, see 4.28 Reset on page 119. Considerations when updating of configuration Configuration files are only fully compatible if the backup and restore are done on products that have CPUs with the same endianess.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Manager in or the user manual for the Device Manager in Unite Connectivity Manager. • Manual update, see below. To update manually: 1 Select Update > Boot. 2 Click "Browse..." and browse to the boot file. 3 Click "Upload". 4 Reset in order to make the changes take effect, see 4.28 Reset on page 119. 4.22.4 Update the RFPs This section only applies to the IPBL.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 4 Select "Immediate" or "Scheduled" update. 5 Select "In sequence" check box to update the selected RFPs one by one. 6 Select "When idle" check box to start the update when the RFP is idle. 7 Mark the applicable RFPs to be updated. 8 Click "Start" to upgrade the selected RFPs. The RFP restarts after the upload is finished. 4.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 4.25 Replacing Master Hardware in a System with a Crypto Master Active If a faulty Master is replaced with a new one, then the faulty Master must be deleted in the Mobility Master. The reason for deleting the replaced Master is that the Crypto Master is operable only if all Masters, part of the Crypto Master hierarchy, are connected. 4.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 4.27.2 Tracing The information gathered from the trace functionality is mainly used for troubleshooting in case of failure in the system. The trace information is intended for the support departments. It is possible to trace traffic information on the LAN for troubleshooting purposes. 1 Select Diagnostics > Tracing.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 4.27.4 Events Under Diagnostics > Events is history of alarms and errors displayed including active alarms. Click "Clear" in the top-right corner to clear the list of alarms and errors. For a description of the attributes, see the table below. Attribute Description Time The date and time when the alarm, error is issued or cleared. Type The status of the fault.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN CPU-R Shows utilization of CPU resources allocated by different tasks. If the CPU resources are fully utilized it will prevent connection of more calls. One solution in that case can be to install an additional Base Station in the same coverage area. MEM Shows utilization of the RAM memory. If the utilization is continuously and significantly increasing then it can be due to memory leakage.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 2 Enter an IP address in the IP Address text field. 3 Press "Enter" on the keyboard. TD 92579EN 4.27.8 Traceroute The traceroute function displays how packets travel from the IPBS/IPBL to a certain IP address. The result is an ordered list of IP addresses with the measured round trip time. 1 Select Diagnostics > Traceroute. 2 Enter an IP address in the IP Address text field.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN • Idle reset - waits until there are no active calls in the IPBS/IPBL. • Immediate reset - clears all calls and resets the IPBS/IPBL. 4.28.1 Idle Reset 1 Select Reset > Idle Reset. 2 Click "OK". 3 The IPBS/IPBL will reset when there are no active calls. 4.28.2 Immediate Reset 1 Select Reset > Reset. 2 Click "OK". 3 The IPBS/IPBL will terminate all active calls and reset. 4.28.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) Long press ~ 10 sec. TD 92579EN Factory reset - all configuration parameters will be set to default values. For IPBS2: When 10 sec. has gone, the LED on IPBS2 will start to flash in blue, indicating the start of the factory reset process. Hence the reset button can then be released. When the LED (LED 1 for IPBS1) is steady amber/ yellow, the factory reset process is complete.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 5 TD 92579EN Commissioning This section describes the visual inspection and tests that must be executed after completing the installation and initialization of the IP-DECT system. The purpose of the visual inspection and tests is to verify that all installation activities have resulted in a correctly functioning system.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 1 Put all handset together in order of extension number on a table. 2 Go off-hook with each handset and check that the dial tone is heard. 3 Call with a handset (handset A) all other handsets sequentially and check that the handset with the corresponding number on its display rings when called. 4 Call handset A and check if it rings. 10 April 2015 / Ver.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 6 TD 92579EN Troubleshooting 6.1 Load Firmware Using the Gwload Tool If the firmware is corrupt, for example if firmware download is interrupted the IPBS/IPBL could become unreachable by the web GUI. It will not be possible to load new firmware or to start correctly.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Connection to Radio lost (Master) 0x00030204 IPBS/IPBL X Primary/redundant trunk is down (Master) 0x00030205 IPBS/IPBL X Master active (Master) This event is generated when the Mirror becomes active. 0x00030206 IPBS/IPBL X Master inactive (Master) This event is generated when the Mirror becomes inactive.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 0x00060003 Signaling TCP failed (H323) The signaling transport connection could not be established. This usually means, the destination (IP) is not reachable. Check network connectivity. IPBS/IPBL X Signaling timeout (H323) A signaling timer expired. The reason for this could be a network problem or an interop problem.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Unknown certificate (TLS) 0x000c012e IPBS/IPBL X Unknown certificate (TLS) 0x000c022e IPBS/IPBL X Illegal parameter (TLS) 0x000c012f IPBS/IPBL X Illegal parameter (TLS) 0x000c022f IPBS/IPBL X Unknown CA (TLS) A TLS connection could not be established because the CA of the remote certificate is not trusted. Check the rejected certificates for details.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 0x000c0407 IPBS/IPBL 0x000c1000 Certificate validation is disabled until system time is set (X509) System time is not set but the current date is needed to validate if cryptographic certificates are valid. Therefore encrypted TLS connections will fail. Configure a NTP server or set the system time manually.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) No route to destination, loop (ipproc) TD 92579EN 0x0011005f IPBS/IPBL Memory Low (box) 0x00120001 This alarm indicates that there is less then 200000 bytes of memory available for allocation IPBS/IPBL Radio busy for speech (Dect) IPBS X 0x00140065 Default encryption key timeout (Dect) Too long delay in the LAN/WAN network for early encryption to work.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Document History For details in the latest version, see change bars in the document. Version Date Description A 5 February 2009-02-02 First released version. B 15 April 2009 2009-04-15 Updated 4.7 UNITE on page 74 and added information about device management and service discovery. C 5 May 2010 2010-03-05 Updated 4.5.15 Configure Supplementary Services on page 60. Updated 4.5.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Version Date Description J 31 May 2013 Updated Assign Handsets to Users on page 23 3.13.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Version Date Description K 10 January 2014 Updated the section 4.5.32 PARI on page 70 to reflect that 2047 IPBSs can now be used per Pari Master in an installation by setting the system ID to 293-296. Updated the fault code descriptions table in section 6.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) Version Date TD 92579EN Description Have added the section 4.7.1 Configure Messaging on page 74 to reflect that a new check box (Broadcast) has been added in Unite > SMS. (Issue IPDECT-953) Have added section 4.5.19 Set Region Code on page 63 which describes how to set region codes which is used for the new feature Call Localization.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Version Date Description PL1 20 January 2014 Have updated the table in section 4.10.2 RFPs on page 86 with more information about Tx and Rx error. (Issue IPDECT-785) Have updated the table in section 4.12.1 Display All Ongoing Calls in the System on page 93 with more information about the statistics field "Handover Cancelled". Have updated the fault code descriptions table in section 6.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Version Date Description M 15 October 2014 Have updated the section 4.2 LAN on page 43 and added Appendix H: Configure DHCP Options on page 163 about DHCP options. (Issue IPDECT-1473) Have updated the section 4.5.20 Configure Gatekeeper on page 63 about how to set the Treat rejected calls as option. (Issue IPDECT-1452) Have updated the section 1.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Appendix A: How to Configure and Use the Update Server A.1 Summary Automatic update is based on configuration and firmware information stored on a standard web server and retrieved by the devices on a regular basis. There are 2 modules in the device which work in tandem.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN However, for new devices (that is, devices which have been reset to factory settings and never had a successful download of a command file), the command file is retrieved every minute (for up to 30 minutes). This is done so that a fresh device can quickly retrieve a site depending standard configuration when it is installed.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN suppressed by the /allow parameter. This allows new devices to retrieve a site specific standard configuration quickly. A.1.4 Setting the UP0 Parameters To perform a firmware update, use the following command: mod cmd UP0 prot The command above downloads the new firmware from and flash it to the device, then is executed.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN mod cmd UP0 scfg This will cause the device to upload its current config to url This will be done using an HTTP PUT command. url must be writable thus.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Specifies which RFPs to update using a hex-encoded bit-mask. Each bit represents an RFP port starting with port 1 at the LSB (0x0001) up to port 16 (0x8000). 0x2753 specifies RFP "1,2,5,7,9,10,11,14" to be updated. mod cmd RFP_UPDATE0 schedule DD.MM.YYYY-HH:MM Specifies when the update shall start. If no date is provided, the update will be immediate when the start command is issued.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 1. Install server role and role services on the Web server 2. Add a virtual directory on the Web server 3. Enable WebDAV and set authoring rules for WebDAV 4. Enable Digest Authentication 5. Enable Directory Browsing 6. Add an AD user and give the user write access to the directory 7. Add a command file to the directory referred by the virtual directory 8.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 3. Enable WebDAV and set authoring rules for WebDAV 14 In "Internet Information Services (IIS) Manager": Left-click on "Default Web Site". 15 Left-double click on "WebDAV Authoring Rules" 16 Left-click on "Enable WebDAV" (link). 17 Left-click on "Add Authoring Rule..." (menu item)". The "Add Authoring Rule" window is shown.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 8. In the IP-DECT device (IPBS/IPBL), enter the URL to the command file 35 See 4.8.1 Configure Automatic Firmware Update on page 76 on how to configure the IPBS/IPBLs for automatic update. 9. In the IP-DECT device (IPBS/IPBL), enter the URL to the directory where the command file is located 36 Select Services > HTTP Client.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Appendix B: Local R-Key Handling Local R-key handling assume that the check box for local R-key handling is selected, see 4.5.8 Local R-Key Handling on page 57. The following R-key functions are available during a call. Key Description R Put the ongoing call on hold and get a new line. (Dial the number to the second call.) R0 Reject the incoming call.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Appendix C: Database Maintenance This section describes how IP-DECT user configuration can be moved from one system to another. By moving users, one IP-DECT system can be split into many systems or several IPDECT systems can be merged to one single system.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Appendix D: Load Balancing Load balancing can be used in an IP-DECT system when the number of handsets exceeds what an IP-PBX is able to register. When load balancing the traffic is distributed over several IP-PBXs which can be done in two ways using: • fixed connections for users on each Master towards multiple IP-PBXs.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Note: The Alt. Proxy 2 text field cannot be used if the Proxy and the Alt. Proxy 1 text fields contain domain names. In the Alt. Proxy 3 text field: Enter the IP address or host name and optionally port of proxy (e.g. proxy4.ascom-rd.com:5060) to the alternative SIP proxy (registrar). Note: The Alt. Proxy 3 text field cannot be used if the Proxy and the Alt.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) D.2.2 TD 92579EN Local Site Redundancy If redundancy is wanted in a remote site, that is you want to be able to make emergency phone call if the WAN connection to the central site goes down, a local site proxy server, e.g. SRST (Cisco), can be used in the remote site, see figure 19 on page 151.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN • Weight: A relative weight for records with the same priority. • Port: the TCP or UDP port on which the service is to be found. • Target: the hostname of the machine providing the service. An example of an SRV record might look like this: _sip._udp.ascom-rd.com. 86400 IN SRV 0 5 5060 sipserver.ascom-rd.com. This points to a server named sipserver.ascom-rd.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 6 D.2.5 TD 92579EN Repeat step 1 to 5 for all exisiting Masters. Load Balancing Using Dynamic Connection: DNS Server Settings The example below shows the settings in Microsoft Windows Server where the DNS server is installed. 1 From a Microsoft Windows Server with the DNS server installed, open the DNS management tool.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 4 TD 92579EN In the "New Resource Record" window, see Figure 21, do as follows: Enter "_sip" in the Service field. Enter _udp in the Protocol field. Assign a priority and weight. For information on how to set priority and weight, see D.2.3 About SRV Records on page 151. Enter "5060" as the port number. Enter the host name of your SIP server (IP-PBX).
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 7 TD 92579EN In the "New Host" window, see Figure 22, do as follows: Enter in the Name field the host name of your SIP server (IP-PBX). Verify that the fully qualified domain name (FQDN) is the correct one. Enter the IP address of your SIP server. Click "Add Host". Figure 22. New host settings 8 Repeat step 1 to 7 for all exisiting IP-PBXs. 10 April 2015 / Ver.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Appendix E: Update Script for Configuration of Kerberos Clients The update script is as follows: mod cmd UP1 check resetn serial002 config add NTP0 /addr 192.168.42.136 config write config activate vars create CMD0/KCMD p
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Appendix F: Install Certificate in the Web Browser To access the GUI for an IPBS/IPBL using secure web access (https), the certificate for the IPBS/IPBL can be installed in the web browser to avoid getting certificate error messages. To install the certificate, perform the following two steps: Step 1. Create a certificate. See F.1 Create a Certificate. Step 2.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 1 TD 92579EN Access the GUI for an IPBS/IPBL. A security warning window will appear when using secure web access (https) to access the GUI. Figure 23. Security warning window. 2 In the security warning window, click on the text link "Continue to this website (not recommended)." The login window for the device will appear.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Figure 24. Sceen shot of the login window, with the "Security Status bar highlighted. Figure 25. The Security Report window. 10 April 2015 / Ver.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) 4 TD 92579EN In the Security Report window, click on the blue text link "View certificates". The Certificate window will appear. Figure 26. The Certificate window. 5 In the Certificate window, click on the button "Install Certificate...". The Certificate Import wizard is started. 6 Click on "Next".
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN 8 Click on "Finish" to complete the Certificate Import wizard. The Security Warning window will appear. 9 Click on "Yes" to install the certificate". 10 April 2015 / Ver.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Appendix G: Used IP Ports Port TCP/UDP Protocol 68 UDP DHCP 80 TCP HTTP 88 UDP KERBEROS 123 UDP NTP 161 UDP SNMP 389 TCP LDAP 636 TCP LDAPS 443 TCP HTTPS 464 UDP KERBEROS 1716-1717 TCP H.323 Master 1718-1719 UDP H.225 Master, Mobility Master, Radio 1718-1719 TCP H.323 Radio 1722-1723 TCP H.323 Master 1724-1727 TCP H.323 Radio 1728-? TCP H.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN Appendix H: Configure DHCP Options IPBS/IPBL include a DHCP client which allows the IP interface to be configured from a DHCP server. In addition to that, IPBS/IPBL also allow configuring a number of settings via special DHCP vendor options. H.1 System Requirements To use vendor specific DHCP options, a DHCP server that supports such options is required.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN POSIX TZ String No 202 Defines both the time zone and the daylight saving time information. This option is in fact identical to the standard DHCP option number 88 (TZ). However, various DHCP servers do not support this option, so it is provided as a redundant vendor specific option. If your DHCP server supports option 88, the vendor specific option is not needed.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) H.4 TD 92579EN Enbloc dialling Byte (8bit) No 209 The number of seconds dialled digits are kept in IP-DECT before they are sent en-bloc to the gatekeeper Enter the number of seconds into the 8bit edit field.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN supplied by the DHCP server are ignored. This is especially useful if in a given setup, some devices are to be configured differently but the majority is still configured by DHCP. This can be achieved using the following config file options: H.
Installation and Operation Manual IP-DECT Base Station & IP-DECT Gateway (software version 7.2.X) TD 92579EN If the server acknowledges the old lease, the client will check for changes in the DHCP options and re-configure itself accordingly. Changed options will be saved in the config file. If the server rejects the lease using a NAK, the client will forget about the lease and continue to operate like it does for the first boot.