M-TUNE means entry to the manual tuning mode. It allows fine tuning of PA, or in the case if
automatic tuning cannot set optimal adjustment of the PA. For proper adjustment we need to show
Screen current (at least). Prior start M-tune define one bar graph to the Screen current, or define all
bar graph as in the next picture.
Press M-TUNE. New screen is visible. Slides on the left and right side represent both variable
capacitors.
Adjustment process: Move TUNE left or right until maximum of FWD power reached. Then move
LOAD carefully so that Ig2 Screen current will be not higher than 20mA. Optimum means
maximum FWD power and Screen between 10 20mA for the full power output. Repeat more
times.
After adjustment press SAVE for
writing values to the memory and press
EXIT.
Repeat adjustment process for other
segments / bands.
Now one example from real situation. First we will check driving power from the transceiver. Stay in
STBY mode, press PTT and apply RF power.
Measured driving power is 16 Watts.
Now switch to OPER, press PTT and
apply RF from TCVR. See the following
picture.
Type of supported TCVR and
working
frequency are visible on the
display.
AUTO LED is ON.
Type of supported TCVR and
working
frequency are visible on the
display.
AUTO LED is ON.