iP1 SmartSystem – Personalized Instruction Manual WARNING EN • Read this manual carefully before loading or using the iP1 pistol. • The iP1 pistol will not operate if it is not within 10” of the iW1 wristwatch with the matching key and the PIN code entered. This manual is only intended: • For use with an iP1 pistol that has been referenced to an iW1 wristwatch; or • to guide through the process of upgrading the iP1 SmartSystem – Basic to the iP1 SmartSystem – Personalized (see Chapter 27) Armatix U.
iP1 SmartSystem – Personalized 2
iP1 SmartSystem – Personalized 3
iP1 SmartSystem – Personalized Safety precautions Read this manual and the warnings contained in it before loading or using the iP1 pistol. This manual explains the function and the handling of the iP1 SmartSystem — Personalized and warns of the potential dangers, including death and serious personal injury, that can result from use of the iP1 pistol.
iP1 SmartSystem – Personalized General safety precautions • Failure to follow the safety information and safety instructions in this manual could result in death, serious personal injury and/or property damage. • The iP1 pistol is intended for target shooting only and will not function if it is not within 10” of the referenced iW1 wristwatch and the PIN code entered, or it or the referenced iW1 wristwatch do not have sufficient battery power, or communication between them is blocked.
iP1 SmartSystem – Personalized • Always make sure the iP1 pistol is unloaded and that the slide is locked open in the rearward position with the magazine taken out before handing it to another person. • Never alter or modify the iP1 pistol because this could cause it to malfunction and create a dangerous condition. • If the iP1 pistol is dropped or forcefully struck, it could be damaged and may not function properly. Have it inspected by Armatix U.S.A., Inc. before continuing to use it.
iP1 SmartSystem – Personalized Most ammunition contains lead in the projectile and/or primer. Firing the iP1 pistol in a poorly ventilated area can lead to the exposure to lead. Always wash your hands after handling ammunition, firing the iP1 pistol, and/or performing preventive maintenance on the iP1 pistol to minimize your exposure to lead. Do not dry fire the iP1 pistol (pull the trigger and allow the hammer to fall on an empty chamber) because this will result in premature wear.
iP1 SmartSystem – Personalized Before it left the factory, the iP1 pistol was tested, carefully inspected, and packaged. Armatix U.S.A., Inc. cannot control what happens to the pistol after it leaves the factory, therefore, carefully examine the iP1 pistol when you acquire it to ensure that it is unloaded and undamaged. If you do not understand any of the warnings and instructions in this manual or have any problems operating the iP1 pistol, contact Armatix U.S.A., Inc.
iP1 SmartSystem – Personalized Table of Contents 1 Introduction 12 2 Main Features of the iP1 Pistol 13 2.1 The iP1 14 2.1.1 Frame with LED and interchangeable backstraps 14 2.1.2 Slide with loaded chamber indicator (LCI) 14 2.1.3 Trigger with trigger switch 15 2.1.4 Slide release lever 16 2.1.5 Magazine release lever 16 2.1.
iP1 SmartSystem – Personalized 6 Activating the iP1 pistol 29 7 Deactivating the iP1 pistol 31 8 Synchronizing the time between the iP1 pistol & the iW1 wristwatch 32 9 Changing / resetting the 5 digit PIN code using the 12 digit SuperPIN 34 10 Resetting the iP1 pistol using the 10 digit pistol PIN code 36 11 Referencing the iP1 pistol to the iW1 wristwatch 38 12 Checking the batteries without using the iW1 wristwatch 40 13 Automatic battery charge indicator 41 14 Loading 42 15 Firing
iP1 SmartSystem – Personalized 22 Changing the backstrap / replacing the batteries in the iP1 pistol 64 23 Adjusting and changing the sights 66 24 Assembly 67 25 Function test 69 26 Storing the iP1 pistol 70 27 Upgrading the iP1 SmartSystem - Basic to the iP1 SmartSystem - Personalized 71 28 Updating the firmware 72 29 Changing the iW1 wristwatch batteries 73 Part list 74 Exploded drawing 75 Technical data 76 Limited one year operational warranty 77 FCC notice 79 Youth Handgun Safe
iP1 SmartSystem – Personalized 1 Introduction Dear Customer, Thank you for choosing the Armatix iP1 SmartSystem – Personalized, which consists of the iP1 .22LR pistol and the iW1 wristwatch and represents a revolutionary innovation. The iP1 pistol is referenced to the iW1 wristwatch and can only be fired by the authorized user, who has the referenced iW1 wristwatch and the required PIN code.
iP1 SmartSystem – Personalized 2 Main features of the iP1 Pistol The iP1 pistol is a semi-automatic, single-action/double-action .22LR pistol with a ten round detachable magazine that has been developed in accordance with the latest ergonomic principles and criteria.
iP1 SmartSystem – Personalized 1.1 The iP1 1.1.1 Frame with LED and interchangeable backstraps The frame features interchangeable backstraps in three different sizes to properly fit the hands of different users. The iP1 pistol comes with the small backstrap installed. Medium and large backstraps are available as options and can easily be changed by the user.
iP1 SmartSystem – Personalized 1.1.3 Trigger with Trigger Switch The trigger includes a mechanical locking switch with prevents it from being pulled to the rear. When the trigger switch is in the left position (when viewed in the firing direction, with the muzzle pointed away from the user), the trigger is locked. When it is in the right position, the trigger is released and can be pulled. Pistol safe. Trigger switch pressed to the left in firing direction. Pistol safe.
iP1 SmartSystem – Personalized 1.1.4 Slide Release Lever When the last round in the magazine is fired, the slide release lever will hold the slide locked in the rearward position to signal that the magazine is empty. When the slide is pulled back with an empty magazine in place, it will also be held in the rearward position by the slide release lever. In addition, when there is no magazine inserted, the slide release lever can be manually pushed up to lock the slide in the fully rearward position. 1.1.
iP1 SmartSystem – Personalized 2 Functioning of the iP1 SmartSystem – Personalized The following describes how the iP1 pistol functions when the magazine is inserted, a round is in the chamber, the trigger switch is in the right (released) position, and the synced iW1 wristwatch with the PIN code entered and the pistol feature activated is worn on the wrist of your shooting hand: • When the backstrap is squeezed towards the front of the iP1 pistol, the backstrap switch is activated and communication betwee
iP1 SmartSystem – Personalized 3 Components of the iP1 SmartSystem – Personalized Scope of supply • iP1 pistol with magazine • iW1 wristwatch (already referenced to the iP1 pistol) • Lockable storage/transportation case • Printed instruction manual • PIN-card • 1/10” diameter punch • 2 AAA batteries for the iP1 pistol • 1 CR2032 battery (already installed in the iW1 wristwatch) • Warranty card • Target: showing the grouping of the shots from the iP1 pistol 18
iP1 SmartSystem – Personalized 4 Operation of the iW1 wristwatch The iW1 wristwatch is used to control the iP1 pistol and should be worn on the wrist of your firing hand as it must be within 10” of the iP1 pistol to communicate with it. Using a PIN code, it can be used to activate the iP1 pistol, set the amount of time within which the iP1 pistol will remain active, and deactivate the iP1 pistol before the set time expires.
iP1 SmartSystem – Personalized Symbol 20 Meaning Pistol menu The small pistol symbol appears in the top right-hand corner when the pistol menu is called up. Settings related directly to the pistol can be carried out here. Remaining time The symbol appears during setting of the remaining time. In the lower half of the display it indicates the remaining time displayed alongside for which the iW1 wristwatch is activated. Alarm clock The symbol appears during setting of the alarm time.
iP1 SmartSystem – Personalized 4.1.1 Scrolling through the individual function menus of the iW1 wristwatch The basic functions of the iW1 wristwatch can be scrolled through using the bottom right and top right buttons. Pressing the bottom right button will change the menu from the standard display (time & date) to the pistol menu, the alarm clock, the stopwatch and back to the standard display. Each pressing the top right button will change the menu in the opposite order.
iP1 SmartSystem – Personalized The basic functions of the wrist watch can be scrolled through with the buttons BR and TR in the recurring sequence illustrated below: Menu sequence when scrolling through with button BR or TR.
iP1 SmartSystem – Personalized 4.1.2 Background lighting The background lighting of the iW1 wristwatch display is activated by pressing the bottom left button for 3 seconds. The background lighting will shut off automatically after a short time. 4.2 Standard display The standard display shows time and date.
iP1 SmartSystem – Personalized When the pistol function of the iW1 wristwatch is activated, the following information is displayed: Activation status of the iW1 wristwatch and status of the pistol battery (bars in the grip). Remaining time until automatic deactivation of the pistol function of the iW1 wristwatch. 4.2.1 Setting the time and date Beginning with the standard display, set the time and date by completing the following steps: 1.
iP1 SmartSystem – Personalized 7. Press the top left button or the bottom left button to alter between 24 hour and 12 hour (a.m. / p.m.) format. Press the top right button to confirm the time format and return to the standard display. If the 24 hour time format is selected, the date will be displayed as date, month, year. If the 12 hour time format is selected, the date will be displayed as month, date, year. 3 sec. + OK – Call up setting: Hold TR pressed for 3 seconds.
iP1 SmartSystem – Personalized 5.2.2 Alarm clock The iW1 wristwatch has an alarm clock that will sound for 20 seconds at the set time. To set the alarm, complete the following steps: 1. Beginning with the standard display, press the bottom right button twice to bring up the alarm clock menu. The last time for which the alarm clock was set will be displayed. 2. Press the top right button for three seconds to set the alarm. 3.
iP1 SmartSystem – Personalized + OK – Alarm clock on / off: Set (TL, BL) and confirm (TR). Standard display appears. 5.2.3 Stopwatch The iW1 wristwatch has a stopwatch that can measure up to 99 hours and 59 minutes. The maximum accuracy of the stop watch is 1 second, and once 59 minutes and 59 seconds is exceeded, it will only continue to measure hours and minutes. To use the stopwatch, complete the following steps: 1.
iP1 SmartSystem – Personalized 3x Call up "Stopwatch" menu: Press BR 3x. Start timing: Button MR. Stop timing: Button MR Reset: Hold MR pressed for 3 seconds. 1x Back to standard display: Press BR 1x. A maximum of 99 hours and 59 minutes can be displayed. After that the stopwatch starts again at 00 hours and 00 minutes. 5.2.
iP1 SmartSystem – Personalized 6 Activating the iP1 - Personalized pistol To activate the iP1 pistol using the iW1 wristwatch, complete the following steps: 1. Beginning with the standard display, press the bottom right button to bring up the pistol menu. 2. Press the top right button for 3 seconds to bring up the pistol submenu. Note: The pistol submenu can also be accessed directly from the standard display by pressing the bottom right button for three seconds. 3.
iP1 SmartSystem – Personalized When the activation time expires you will be alerted by a sound from the iW1 wristwatch and the iP1 pistol will no longer be activated. To reactivate the iP1 pistol, you must complete steps 1 through 4 again. 5.
iP1 SmartSystem – Personalized 7 Deactivating the iP1 - Personalized pistol To deactivate the iP1 pistol using the iW1 wristwatch before the activation time expires, complete the following steps: 1. Beginning with the standard display, press the bottom right button to bring up the pistol menu. 2. Press the top right button for 3 seconds to deactivate the pistol. Note: The iP1 pistol can also be deactivated directly from the standard display by pressing the bottom right button for three seconds. 3.
iP1 SmartSystem – Personalized 8 Synchronizing the time between the iP1 pistol & the iW1 wristwatch The iP1 pistol will only be activated by the iW1 wristwatch when their system times are synchronized.
iP1 SmartSystem – Personalized Starting situation is the message “no sync” on the display. Display: "no sync" pistol symbol, + and – flash. 33 Empty magazine inserted. During backstrap is actuated, Press TL once. iP1 Pistol and iW1 wristwatch are synchronised. Standard display appears.
iP1 SmartSystem – Personalized 9 Changing / resetting the 5 digit PIN code using the 12 digit SuperPIN If the PIN code entry was deactivated because an incorrect PIN code was entered three times in a row when attempting to activate the iP1 pistol, or you want to change the PIN code, you can define a new PIN code using the iW1 wristwatch and the 12 digit SuperPIN by completing the following steps: 1.
iP1 SmartSystem – Personalized misstake in entering a digit, it can be corrected by pressing the middle right button. When the fifth digit is entered, the PIN code is automatically accepted. If both PIN code entries match, the standard display will appear. 6. If the PIN code entries do not match, repeat steps 4 and 5. 1 3 sec. 3 sec. Hold TL, TR, BL and BR depressed for 3 seconds. 1 2 3 4 Enter new PIN code. 35 MR: Cancel. Press any other button to input the SuperPIN. 1 2 3 4 Repeat new PIN code.
iP1 SmartSystem – Personalized 10 Resetting the iP1 pistol using the 10 digit pistol PIN code Make sure that the iP1 pistol is unloaded (magazine removed and chamber empty) before resetting it using the 10 digit pistol PIN code. Do not reset the iP1 pistol with the iW1 wristwatch in public places to avoid that someone can record the radio signal and can get access to your pistol PIN code when it is transferred from the iW1 wristwatch to the iP1 pistol.
iP1 SmartSystem – Personalized 7. If the display reads “dONE,” the iP1 pistol has been reset. If the display reads “no” an incorrect PIN code was entered and steps one through six must be repeated. 8. Press any of the buttons on the iW1 wristwatch to bring up the standard display. Once the iP1 pistol has been reset, it cannot be fired until it has been referenced with a iW1 wristwatch again. 3 sec. 1x Call up pistol menu: Press BR 1x. After last digit: pistol symbol flashes, receiver ready.
iP1 SmartSystem – Personalized 11 Referencing the iP1 pistol to the iW1 wristwatch Make sure that the iP1 pistol is unloaded (magazine removed and chamber empty) before referencing it to the iW1 wristwatch. Before referencing the iP1 pistol to the iW1 wristwatch, you need to enter the PIN code in the iW1 wristwatch pursuant to the instructions on activating the pistol. If purchased as a iP1 SmartSystem — Personalized, the iP1 pistol was already referenced to the iW1 wristwatch when it was manufactured.
iP1 SmartSystem – Personalized 3 sec. Activate pistol function! 1x Call up pistol menu: Press BR 1x. Hold the pistol in your hand (backstrap actuated, empty magazine inserted). 39 Wristwatch ID and code are transmitted to the pistol and stored. 3 sec. Function "Reference pistol": Hold TR and BR depressed for 3 seconds. Wristwatch is ready to transmit. Referencing successful Press any button to return to the standard display. Standard display with activated pistol function appears.
iP1 SmartSystem – Personalized 12 Checking the batteries without using the iW1 wristwatch Unless the iP1 pistol is in storage, check the battery charge level at least once a month and replace batteries if necessary. To check the battery charge level without using the iW1 wristwatch, remove the magazine and grip the frame, and briefly squeeze the backstrap towards the front of the iP1 pistol and release it.
iP1 SmartSystem – Personalized 13 Automatic battery charge indicator Five seconds after the backstrap of the iP1 is released, the iP1 performs an electronic function check, including checking the battery power. If the batteries are very low, and must be changed immediately to ensure reliable functioning of the iP1 pistol, it will be shown through the LED indicator, about four seconds after the backstrap is squeezed the next time, as follows: • If the LED is lit up in green or blue, it will flash red twice.
iP1 SmartSystem – Personalized 14 Loading Use of improper ammunition could cause death or serious personal injury, and/or property damage. Only use high quality commercially manufactured .22 LR ammunition that meets SAAMI or CIP standards. Identify the particular type of ammunition that Armatix recommends for use in the iP1 pistol. To load the magazine, press each cartridge into the magazine from the front, with the cartridge bottom first, against the force of the magazine spring. A maximum of ten .
iP1 SmartSystem – Personalized If the slide is locked in the rearward position, either press the slide stop lever down to release the slide and return it to the fully forward position, or grasp the rear of the slide at the indented area with your other hand and pull the slide fully back and then release it, allowing it to return to the fully forward position.
iP1 SmartSystem – Personalized 15 Firing • • Always make sure that the cover is locked before firing the iP1 pistol. If it is not correctly installed, the pistol will still fire, but the slide will not be locked which could lead to serious personal injury and/or damage to the iP1 pistol. • The iP1 pistol will not operate if it is not within 10” of the referenced iW1 wristwatch and the PIN code entered.
iP1 SmartSystem – Personalized • Never pull the trigger if the slide does not fully close to prevent a possible out of battery firing. If this happens, unload the iP1 pistol as described in Chapter 19, examine the round that was in the chamber, and check the chamber to ensure that there are no obstructions or debris in it. • Always wear safety glasses when firing the iP1 pistol to protect your eyes. • Always wear ear protection when firing the iP1 pistol to protect your hearing.
iP1 SmartSystem – Personalized • Never place your fingers in the ejection port because they could be injured by the movement of the slide. • Never fire the iP1 pistol near an animal unless it is trained to accept that noise. An animal’s startled reaction could injure it, or cause it to injure you or someone else.
iP1 SmartSystem – Personalized 16 Reloading when firing When reloaded in the following manner, the iP1 pistol will be cocked and ready to fire by pulling the trigger. If you do not intend to immediately continue firing the iP1 pistol, do not reload it in this manner. When the last cartridge is fired, the slide will be locked in the rearward position by the slide stop lever. In order to insert a new magazine and resume firing, complete the following steps: 1.
iP1 SmartSystem – Personalized 17 Clearing malfunctions (jams) In case of a failure to fire, continue to hold the iP1 pistol pointed towards the target for at least 30 seconds. If a hangfire (slow ignition) has occurred, the cartridge should fire within approximately 30 seconds. If the cartridge has not fired, remove the magazine, eject the cartridge from the chamber and examine its primer. If the firing pin indentation is light or non-existent, stop using the iP1 pistol and have it examined by Armatix U.
iP1 SmartSystem – Personalized All auto-loading pistols may occasionally experience a malfunction (jam) related to the feeding of ammunition. Most malfunctions are caused by improper ammunition, improper lubrication, or a damaged magazine. To minimize the chance of malfunctions (jams), regularly clean the iP1 pistol pursuant to the instructions in Chapter 21 of this manual.
iP1 SmartSystem – Personalized 18 Trouble shooting This chapter describes other possible malfunctions that may occur and corresponding remedial measures that the user can perform based on the cause of the malfunction. If the malfunction cannot be remedied with the measures described here, please contact Armatix U.S.A., Inc. 18.1 Mechanical malfunctions Malfunction Cartridge does not fire. Cause Communication error between the iW1 wristwatch and the iP1 pistol. Faulty ammunition.
iP1 SmartSystem – Personalized Malfunction Cause Fired cartridge case Cartridge case deformed or chamjams in the chamber. ber dirty. Cartridge is not chambered. Chamber dirty. Remedial measure Remove the magazine. Push the cartridge case out through the barrel using a wooden dowel. Clean the iP1 pistol. Use other / recommended ammunition. Use other / recommended ammunitio. Unload and clean the iP1 pistol. Recoil spring damaged. Replace recoil spring. Magazine not inserted correctly.
iP1 SmartSystem – Personalized Malfunction Bullet strikes to the side of the target. Cause Faulty ammunition. Front sight not properly adjusted. Bullet strikes above or below the target. Faulty ammunition. Remedial measure Use other / recommended ammunition. Adjust front sight. Front sight damaged. Use other / recommended ammunition. Replace front sight. Cause No or empty batteries in the iP1 pistol. Backstrap switch damaged. Remedial measure Install fully charged batteries in the iP1 pistol.
iP1 SmartSystem – Personalized Malfunction LED display flashes red and the pistol symbol flashes on the iW1 wristwatch. Cause iP1 pistol is not referenced with the iW1 wristwatch. Remedial measure Reference the iP1 pistol to the iW1 wristwatch. LED display lights up blue No magazine inserted. Insert magazine. Magazine not inserted correctly. Push in the magazine completely (must engage noticeably). LED display lights up iP1 pistol batteries have insufficient weakly. charge.
iP1 SmartSystem – Personalized 19 Unloading procedure and safety check • Do not uncock the iP1 pistol with a cartridge in the chamber. If you lose your grip on the hammer while lowering it, the iP1 pistol may unintentionally discharge, possibly leading to death or serious personal injury to you or others. • Although the iP1 pistol has a loaded chamber indicator (LCI) you should never solely rely on it or your memory to determine whether the iP1 pistol is loaded or unloaded.
iP1 SmartSystem – Personalized 5. Once the slide is locked to the rear, both visually and physically (with your finger) inspect both the chamber and the magazine well of the iP1 pistol to be sure that no ammunition remains in either place. 6. Release the slide to return it to the forward (closed) position by either pressing the slide stop lever down or grasping the rear of the slide at the indented area with your other hand and pulling the slide fully back and then releasing it. 7.
iP1 SmartSystem – Personalized 20 Disassembly • Unload all magazines and remove all live ammunition from the area before disassembling the iP1 pistol to reduce the chance of a negligent discharge. • Although the iP1 pistol has a loaded chamber indicator (LCI) you should never solely rely on it or your memory to determine whether the iP1 pistol is loaded or unloaded.
iP1 SmartSystem – Personalized 3. While holding the grip with your firing hand, with your finger off the trigger and outside of the trigger guard, grasp the rear of the slide at the indented area with your other hand and pull the slide fully back to eject any cartridge that may be in the chamber. 4. Lock the slide in the rearward (open) position by pushing up on the slide lock and slowly releasing the slide from the fully rearward position until it locks in the open position. 5.
iP1 SmartSystem – Personalized After pulling off the cover, the slide can now be removed as illustrated: 2. 1. Pull the slide completely to the rear and lift out. Remove the slide to the front over the barrel. The pistol is dismantled. Never further disassemble the iP1 pistol. Any further disassembly by untrained persons could cause the iP1 pistol to malfunction and will void the warranty.
iP1 SmartSystem – Personalized 21 Cleaning • Always be sure that the barrel of the iP1 pistol is clear of obstructions before firing it. Remove any obstructions before firing the iP1 pistol so that it will function safely and correctly. Any obstruction in the barrel could prevent the pistol from firing properly and result in death or serious personal injury and/or damage to the iP1 pistol. • Although the iP1 pistol has a magazine disconnect, it is electronically controlled and could fail.
iP1 SmartSystem – Personalized Only use commercially available gun solvent and gun oil or a cleaner-lubricant-preservative. Use of improper cleaning fluids could damage the iP1 pistol. Regular cleaning and care of the iP1 pistol is important to prolong its serve life by reducing wear and helping to ensure its functional safety.
iP1 SmartSystem – Personalized 4. Before firing the iP1 pistol, run a clean patch through the barrel, from the chamber end, using the cleaning rod. Repeat this procedure until the patch comes out of the barrel with no gun oil or cleaner-lubricant-preservative on it. If you will be storing the iP1 pistol, do not perform step 4 until you are ready to use it. 5.
iP1 SmartSystem – Personalized 6. Wipe the exposed areas of the slide that you have cleaned in step 5 with a clean patch and examine it. If it is not clean, repeat steps five and six until the patch remains clean. 21.3 Frame Check the frame for cleanliness. If necessary, clean the frame as follows: 1. Wipe exposed parts of the frame with a clean patch that has been slightly dampened with gun cleaning solvent or a cleaner-lubricant-preservative. 2.
iP1 SmartSystem – Personalized Your iP1 pistol is designed to operate properly with only a small amount of lubrication. Do not over-lubricate the iP1 pistol because too much lubricant can collect unburned powder and other debris and prevent the iP1 pistol from functioning properly.
iP1 SmartSystem – Personalized 22 Changing the backstrap / replacing the batteries in the iP1 pistol Make sure that the iP1 pistol is unloaded (magazine removed and chamber empty) before changing the backstrap or replacing the batteries. • The batteries included with the iP1 pistol are not rechargeable. Never try to recharge non-rechargeable batteries. They may explode or catch fire. • Never try to disassemble batteries. Battery fluids can cause serious injuries.
iP1 SmartSystem – Personalized 5. Use the 1/10” punch to push the pin into the hole at the bottom of the frame, near the magazine well, until it is flush with both ends. 1. 2. First carry out safety check then release and remove the magazine. Insert the batteries as illustrated. 65 Press out the pin using a punch (1/10 " diameter). Pull the backstrap down and to the rear. Fit the desired backstrap and assemble the pistol.
iP1 SmartSystem – Personalized 23 Adjusting and changing the sights Make sure that the iP1 pistol is unloaded (magazine removed and chamber empty) before adjusting or changing the sights. The front sight is held in place by the front sight mounting. The point of impact can be changed horizontally by adjusting the front sight. Front sights are available in four different heights to change the point of impact vertically.
iP1 SmartSystem – Personalized 24 Assembly Always wear safety glasses when reassembling the iP1 pistol to protect your eyes from springs. To assemble the iP1 pistol, follow the instructions below. 1. Push the recoil spring onto the barrel. 2.
iP1 SmartSystem – Personalized Push the recoil spring onto the barrel. CLICK Push on the cover until it engages. 68 Push the slide over the spring and pull back over the barrel. Pull the slide back as far as it will go and place onto the guide. CLICK Push in the magazine completely. The pistol is assembled. Push the slide forward in the guide.
iP1 SmartSystem – Personalized 25 Function test Make sure that the iP1 pistol is unloaded (both chamber and magazine empty) before performing a function test. After assembling the iP1 pistol or remedying a malfunction, you should perform a function test to ensure that it is operating correctly by completing the following steps: 1. Insert an empty magazine into the magazine well and make sure that it noticeably locks into place. 2.
iP1 SmartSystem – Personalized 26 Storing the iP1 pistol • Always make sure the iP1 pistol is unloaded (both chamber and magazine empty) and the hammer is in the forward (uncocked) position before storing it. • Always store and transport the iP1 pistol unloaded and locked in a suitable container, such as the included pistol case, out of the reach and sight of children or other unauthorized persons.
iP1 SmartSystem – Personalized 27 Upgrading the iP1 SmartSystem - Basic to the iP1 SmartSystem Personalized Make sure that the iP1 pistol is unloaded (both chamber and magazine empty) and the hammer is in the forward (uncocked) position before performing the upgrade procedure. An iP1 SmartSystem – Basic can be upgraded to the iP1 SmartSystem – Personalized and synced with an iW1 wristwatch.
iP1 SmartSystem – Personalized 28 Updating the firmware The firmware for the iW1 wristwatch and the iP1 pistol can be updated using the optional USB tool. To allow the iW1 wristwatch to communicate with the USB tool, beginning with the standard display press the top left and bottom left buttons for 3 seconds until the display reads “HF rEAdy.” To exit the USB communication mode and return to the standard display, press any key.
iP1 SmartSystem – Personalized 29 Changing the iW1 wristwatch batteries • The battery included with the iW1 wristwatch is not rechargeable. Never try to recharge non-rechargeable batteries. They may explode or catch fire. • Never try to disassemble batteries. Battery fluids can cause serious injuries. • Never expose batteries to high temperatures because they may explode. The iW1 wristwatch operates using a single CR2032 battery. To change it, proceed as follows: 1.
iP1 SmartSystem – Personalized Part list The iP1 SmartSystem – Personalized from Armatix U.S.A., Inc. is a high-tech product that is manufactured with the highest precision. Accordingly, most parts have to be replaced by returning the pistol to Armatix U.S.A., Inc. Only those parts marked with an * are available for purchase and can be replaced by the user. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Frame Slide Recoil spring * Cover * Magazine assembly * Backstrap: * a. small (included) b. medium (optional) c.
iP1 SmartSystem – Personalized Exploded drawing 9* 8* 2 3* 4* 1 6c* 6b* 10* 7* 5* 75 6a*
iP1 SmartSystem – Personalized Technical Data Technical Data Overall length Backstrap S 170 mm 6.69 in Overall width Backstrap M 173 mm 6.81 in Backstrap L 175 mm 6.89 in 30 mm 1.18 in Trigger length 77 mm 3.03 in Weight 78 mm 3.07 in without magazine 518g / 18.27 oz. with empty magazine 576g / 20.32 oz. Barrel length 92 mm 3.
iP1 SmartSystem – Personalized Limited one year operational warranty Subject to the terms, conditions and limitations outlined below, Armatix U.S.A., Inc. guarantees the iP1 SmartSystem — Personalized against defects in materials and workmanship that adversely affect its operation for a period of one (1) year from the date of its original purchase by the initial consumer.
iP1 SmartSystem – Personalized The sole and exclusive remedy pursuant to this warranty is the repair or replacement of the iP1 SmartSystem — Personalized, at the sole discretion of Armatix U.S.A., Inc. The implied warranties of merchantability and fitness for a particular purpose are expressly disclaimed. All disclaimers and limitations of liability shall still apply even if the limited remedy of repair and replacement fails of its essential purpose. In states where permitted, Armatix U.S.A., Inc.
iP1 SmartSystem – Personalized FCC Notice This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
iP1 SmartSystem – Personalized Youth Handgun Safety Act Notice (1) The misuse of handguns is a leading contributor to juvenile violence and fatalities. (2) Safely storing and securing firearms away from children will help prevent the unlawful possession of handguns by juveniles, stop accidents, and save lives.
iP1 SmartSystem – Personalized (3) This subsection does not apply to– (A) a temporary transfer of a handgun or ammunition to a juvenile or to the possession or use of a handgun or ammunition by a juvenile if the handgun and ammunition are possessed and used by the juvenile– (i) in the course of employment, in the course of ranching or farming related to activities at the residence of the juvenile (or on property used for ranching or farming at which the juvenile, with the permission of the property owner o
iP1 SmartSystem – Personalized (C) a transfer by inheritance of title (but not possession) of a handgun or ammunition to a juvenile; or (D) the possession of a handgun or ammunition by a juvenile taken in defense of the juvenile or other persons against an intruder into the residence of the juvenile or a residence in which the juvenile is an invited guest.
iP1 SmartSystem – Personalized (ii) A juvenile is described in this clause if– (I) the offense of which the juvenile is charged is possession of a handgun or ammunition in violation of section 922(x)(2); and (II) the juvenile has not been convicted in any court of an offense (including an offense under section 922(x) or a similar State law, but not including any other offense consisting of conduct that if engaged in by an adult would not constitute an offense) or adjudicated as a juvenile delinquent for con
iP1 SmartSystem – Personalized State required safety warnings The following warnings are required by certain jurisdictions: California WARNING “Children are attracted to and can operate firearms that can cause severe injuries or death. Prevent child access by always keeping guns locked away and unloaded when not in use. If you keep a loaded firearm where a child obtains and improperly uses it, you may be fined or sent to prison.
iP1 SmartSystem – Personalized Maine “ENDANGERING THE WELFARE OF A CHILD IS A CRIME. IF YOU LEAVE A FIREARM AND AMMUNITION WITHIN EASY ACCESS OF A CHILD, YOU MAY BE SUBJECT TO FINE, IMPRISONMENT OR BOTH. KEEP FIREARMS AND AMMUNITION LOCKED UP. USE TRIGGER LOCKS.” Maryland WARNING: “Children can operate firearms which may cause death or serious injury.
iP1 SmartSystem – Personalized ARMS STORAGE. FOR INCREASED SAFETY, FIREARMS SHOULD BE STORED UNLOADED AND LOCKED IN A LOCATION THAT IS BOTH SEPARATE FROM THEIR AMMUNITION AND INACCESSIBLE TO CHILDREN AND OTHER UNAUTHORIZED PERSONS.” North Carolina: “IT IS UNLAWFUL TO STORE OR LEAVE A FIREARM THAT CAN BE DISCHARGED IN A MANNER THAT A REASONABLE PERSON SHOULD KNOW IS ACCESSIBLE TO A MINOR.
iP1 SmartSystem – Personalized Manufactured by: Armatix GmbH Feringastraße 4 85774 Unterföhring Germany Tel.: +49 89 / 4 27 29 79 – 0 Email: info@armatix.de Webpage: www.armatix.de Imported and distributed in the United States by: Armatix U.S.A., Inc. 23121 Coltrane Avenue Newhall, CA 91321 Tel.: 855-477-1972 Email: customerservice@armatix.us Webpage: www.armatix.us Despite the greatest care taken in the compilation of this instruction manual, data can change even at short notice. Therefore Armatix U.S.
Armatix U.S.A., Inc. 23121 Coltrane Ave Newhall, CA. 91321 USA Tel.: 1-855-477-1972 E-Mail: customerservice@armatix.us Webpage: www.armatix.us © Armatix U.S.A ., Inc.