ARIZE Smart Thermostat AST110 User Manual R
Installation Guide AST110 Smart Wi-Fi Thermostat First things first.
You may also need these tools: Phillips screwdriver Pencil Level Home Wi-FiPassword Compatibility Section For conventional ( gas / oil / propane / electric ) heat-pump and dual fuel systems.
Incompatible wiring and voltage Please check your old thermostat’s wall plate have any below indicators? • Does not work with electric baseboard heat ( 110VAC~240VAC ) • Does not work with millivolt systems • Does not support S terminals for indoors and outdoors sensors.
Download the App Search Arize Resident in the App Store or Google Play Store,then download
Installation This AST110 thermostat is designed to work on most 24V-AC ow voltage heating and cooling systems such as gas and oil furnaces, heat pumps, and single or dual-stage systems. Step 1 Switch off power ON or This protects you and avoids blowing a fuse in your equipment. To make sure the power is off, change the temperature with your current thermostat and wait at least five minutes to be sure that your system doesn’t turn on.
Step 2 Check that your system is off Confirm your system is off by turning on your heat ( during winter ) or your AC ( during summer ). Wait a few minutes—you should not feel air coming from your vents. NOTE : If you have a digital thermostat with a blank display, skip this step.
Step 4 Take a picture of the wires Take a picture of your existing wall plate’s wiring and save it for reference. Make sure you can read the wire terminal labels. Step 5 Label the wires Use the wire label provided with your new thermostat to label each wire on your old wall plate. NOTE : If you have an Rc or Rh wire, put the R label onit.
Step 6 Disconnect the wires and remove the old wall plate Disconnect the wires from the old thermostat one by one, you may need a screwdriver to release wires from terminals. NOTE : Wrap the wires around a pen or pencil so they don’t fall back into the hole in the wall. Step 7 Mount the New Wall Plate Use the enclosed screws and anchors to mount the new wall plate. In most cases, you can utilize the same mounting position of your old thermostat.
Look at the thermostat wiring photo you took. The following are wiring diagrams for common systems, please confirm you have a C connected to your old thermostat.
Single Stage Heat / Two Stage Heat- Furnace / Boiler with C wire RC RH G W/E Y C Y2 O/B/W2 Thermostat 1st Stage Heat 2nd Stage Heat Combined Single Stage Heat and Single Cool Stage with C wire ( Remove Pre-installed Jumper ) Cool Furnace and Air Conditioner RC RH G W/E Y C Y2 O/B/W2 Thermostat
Single Stage / Two Stage Heat Pump with Emergency Heat and Auxiliary Heat with C wire RC RH G W/E Y C Y2 O/B/W2 Thermostat Em e r g.
Dual Fuel System-Combined Single Stage Heat Pump and Single Stage Furnace with C wire RC RH G W/E Y C Y2 O/B/W2 Thermostat
If you do not have a C-wire connected to your old thermostat, please check below wiring diagram. Do you have a spare wire? Yes. 1. 2. 3. 4. 5. Check for spare wire behind your wall plate or old thermostat, if you have a spare wire, connect it to the C terminal on the new wall plate. Remove cover from furnace or heating system, open the heating and cooling system’s cover to find the control board. You should see the same terminal labels that are on your thermostat.
Conventional system without the C wire (also commonly called a 4-wiresystem ) 1. 2. 3. Remove cover from furnace or heating system, open the heating and cooling system’s cover to find the control board. You should see the same terminal labels that are on your thermostat, move the G wire to the C terminal, then use the included jumper wire to connect G with Y. At the thermostat, connect C with the G wire; With this configuration the thermostat will have no fan control.
Heat only 3-Wire system G W/E R Y C O/B Heating wiring terminal Move G wire to C terminal RC RH G W/E Y C O/B Thermostat Move G wire to C terminal
Cool only 3-Wire system G R Y W/E C O/B A/C wiring terminal Move G wire to C terminal RC RH G W/E Y C O/B Thermostat Move G wire to C terminal
Step 8 Connect the wires to the new wall plate Refer to the above wiring diagram, insert all wires vertically from the open socket into the proper terminal. Ensure each wire is inserted into the matching terminal (refer to the photo taken previously if needed). Pull wires gently to ensure wires are securely fastened. RC RH G W/E Y C Y2 O /B /W 2 When all wire connections have been ompleted, place any excess wire back inside the wall.
Step 10 Power on and Enjoy Turn on the switch that controls your heating and cooling system, th thermostat will power on and prompt you to start the setup. If you are having trouble, please refer to our help guide.
User Manual AST110 Smart Wi-Fi Thermostat Initial Setup Step 1 Device Initial Setup For a quick and easy way to begin using your new smart thermostat, the device will automatically direct you to the Initialization Setup process once it’s turned on for the first time. 1 Heat Type Select your home’s heating type from the options available: Heat Pump, Gas/Oil, Electric, Dual Fuel, or No Heating, select your Heat Type according to the heating appliance located in your home.
Below is a list of helpful tips that may guide you to selecting the correct option for your home. If you have a furnace or boiler: 1. Select Gas/ Oil. 2. Touch OK button to continue. 3. Then select Appliance or Thermostat depending on your personal preferences for fan control. If you have a heat pump: 1. Select Heat Pump and touch OK to next step. 2.
If you have a Dual fuel system: 1. Select Dual Fuel and touch OK to next step, 2. Then follow the on-screen instructions to configure the fossil fuel heating appliance settings, 3.Click Next at the button of the screen to continue to configure the heat pump heating appliance settings.
2 Wi-Fi Setup A reliable Wi-Fi connection is required in order to access smart features such as remote access, weather forecast and more. Please follow on-screen instructions to complete the Wi-Fi setup.
Step 2 Add Device to your Account You can ask the property manager to assign the thermostat to your account
User Manual AST110 Smart Wi-Fi Thermostat Main Screen Indoor temperature Heating Setpoint Cooling Setpoint Indoor Humidity Current Mode Menu Entry Current Fan Mode
Advanced Setting: To access the Equipment Setup, click on a setting and use the scroll wheel to modify the default value by following steps: Menu- Setting- Advanced setting. Terminal Deadband Default 1℉ Max 2℉ Min 0.5℉ Description A temperature range between the current temperature and the heating setpoint, where heating or cooling is not engaged. Fan Delay 60s 120s 30s The time fan continues after mode turn off. Min Run time 180s 300s 60s The min. time system on after engaging.
FCC STATEMENT 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.