User’s Manua Data Collector PI-XXXX, AP-XXXX,SP-XXXX,PE-XX (X=0-9 , A-Z , a-z , dash , or blank)
Regulatory Compliance FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
CAUTION: Any changes or modifications not expressly approved by the grantee of this device could void the user's authority to operate the equipment. RF exposure warning The equipment complies with FCC RF exposure limits set forth for an uncontrolled environment. The equipment must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with Part 15 of the FCC Rules.
RF Exposure Information (SAR) This device meets the government’s requirements for exposure to radio waves. This device is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission of the U.S. Government. The exposure standard employs a unit of measurement known as the Specific Absorption Rate, or SAR. The SAR limit set by the FCC is 1.6 W/kg.
CAUTION: EXPLOSION HAZARD Do not disassemble, short circuit, heat the battery or dispose of in fire. Store battery pack in a proper place. Do not expose to temperature above 60℃/140℉. Use specified charger only. Please dispose of the used batteries following the rules or laws issued by the local government.
Release Note Version Date Note V1.
Content 1 Introduction .......................................................................... 1 1.1 Unpacking ................................................................. 2 1.2 Understand your terminal ........................................ 4 1.2.1 Terminal ........................................................ 4 1.2.2 Holder(Option).............................................. 5 1.3 Indicators .................................................................. 6 1.3.1 LED .....................
3.1.4 Information ................................................. 32 3.2 System Menu .......................................................... 33 3.2.1 Remote Link ................................................ 33 3.2.2 Disk info ...................................................... 33 3.2.3 Timer setting ............................................... 34 3.2.4 Environment ............................................... 35 3.2.5 Test .............................................................. 36 3.
1 Introduction PI series is a lightweight, portable data terminal (PDT) for data capture and collection. This manual will help you to get to know PI series and utilize it well. Features ■ Scratch-resistant keypad Coated with PC (polycarbonate), the letters and numbers on the keys won’t wear off between uses. ■ Battery cover open detection When the switch of the battery cover is up, the system automatically saves your files and shut down.
1.1 Unpacking Make sure all of the following items are included in your package.
Plug and Power Supply (Option) When you receive your terminal, open the package immediately and inspect for shipping damage. If you discover any damage, contact the shipping company and file a claim. Argox is not responsible for any damage incurred during shipping. Save all package materials for the shipping company to inspect. Note If any item is missing, please contact your local dealer.
1.2 Understand your terminal 1.2.1 Terminal Left Front Right Back 1 2 4 3 Top 5 Bottom 6 8 7 1 LED Three LEDs. 2 LCD Display A mono LCD. 3 Keypad A 25-key keypad. 4 Battery Cover The battery cover. 5 Battery Cover Switch Open and close the battery cover. 6 Reading Window The bar code reading beam is emitted through this window.
8 Connector A port to connect computer 1.2.2 Holder(Option) The holder is used to hold your terminal in its standing position. In the bottom of holder, make sure cable wire is installed as below.
1.3 Indicators PI series has three LEDs and a buzzer to indicate its current status. 1.3.1 LED Your terminal has three LEDs on the upper-left corner. They have different behavior. The table below gives information about the status they indicate.
Charger LED LED Scan LED BT & Wi-Fi LED Red Behavior Solid green Status User defined Note Use SDK. Solid red User defined. Use SDK. Solid orange User defined. Use SDK. Flashing Transmitting data or Use SDK. green user defined. Flashing red User defined. Use SDK. Flashing orange User defined. Use SDK. Off No data transmission or user defined. Use SDK. Solid blue Your terminal is connected through Bluetooth or Wi-Fi.
LED Behavior Status Note by hardware. Off Your terminal is not connected to any power source. Controlled by hardware. 1.3.2 Buzzer You can define the status the vibration indicates using the SDK. Sound 1 Short Beep Status A key is pressed. A good scan. An error occurred. 2 Short Beep The battery is low. 4 Short Beep Battery is too low to turn off terminal. 1.3.3 Vibration You can define the status the vibration indicates using the SDK. Vibration Vibrate Status A good scan.
1.4 Keypad Scan key Cursor keys Control keys Numeric keys User-defined keys Power key Scan key Scan a bar code. Cursor keys Up Move the highlight bar up. Fn+Up Open Message Menu. Down Move the highlight bar down. Fn+Down Adjust the backlight brightness. The brightness repeats the sequence 0123. Left Move the highlight bar to the top. Fn+Left Reduce the volume.
Cursor keys Fn+Right Increase the volume. Control keys ESC The Escape key. 1. Go up one level in a menu. 2. Give up changing a setting. 3. Exit a program. Fn The Function key. Use with other keys. Ex: “Fn+Down Arrow” is to adjust the backlight brightness. The function of F0 - F9 (Fn+0 - 9) can be defined using an SDK. ENT The Enter key. 1. Enter a menu. 2. Select an option. BS The Backspace key. 1. Delete a character to the left of the cursor.
Numeric keys 3 1. Enter the number three. 2. Enter the letters D, E, F. 4 1. Enter the number four. 2. Enter the letters G, H, I. 5 1. Enter the number five. 2. Enter the letters J, K, L. 6 1. Enter the number six. 2. Enter the letters M, N, O. 7 1. Enter the number seven. 2. Enter the letters P, Q, R, S. 8 1. Enter the number eight. 2. Enter the letters T, U, V. 9 1. Enter the number nine. 2. Enter the letters W, X, Y, Z. 0 1. Enter the number zero. 2.
User-defined keys P1 User-defined key. P2 User-defined key. P3 User-defined key. Power key Turn on or turn off your terminal. Power combination key You can use the key combinations to enter different menus or modes. Press and hold the combination of keys, until your terminal responds. 3 + 9 + Power System Menu. 1 + 3 + 0 + Power Supervisor Menu. 1 + 3 + Power Force mode. P1 + P2 + P3 + Power BIOS reset. SCAN + Power Warm reset. SCAN + Power (5 sec) Cold reset.
■ System Menu Enter System Menu. ■ Supervisor Menu ■ Force mode Enter Supervisor Menu. It updates all firmware files and restores all system parameters to factory settings. This mode needs to be used with an SDK or computer software. You can use this mode when you encounter the problem that can’t be resolved in any other way. ■ BIOS reset it is the same as BIOS default (see Supervisor Menu). It resets all your terminal settings, including the password of Supervisor Menu.
1.5 Power source There are three ways to supply power to PI series: 1. Two AA batteries. Recommended alkaline rechargeable type. 2. Use the USB cable with computer. 3. Use the power supply with the USB or RS-232 cable. Cable Type USB Charge your batteries Yes Supply power without batteries Yes Need to use with a power supply No RS-232 No No Yes Warn Do not collect data while plug the connector. It could cause damage to RS-232 and USB port function.
1.5.1 Inserting or replacing battery When you see the battery icon shows low. You need to change new battery or charge It immediately. If there is no power, the back up battery can hold the data about 15 minutes. Therefore, always upload your important data after work or keep two AA batteries in case. Caution Do not mix old batteries and new batteries or standard (carbon-zinc) with alkaline batteries. Remove batteries if product is not to be used with for a long time.
2. Inserting two batteries as indicated inside battery compartment. + - + 3. Close the battery cover as follow.
4. Make sure cover is closed and slide two latch back.
1.5.2 Charge the battery If you’re using rechargeable batteries to supply power to your terminal, you can charge them by (1) connecting the USB cable to your terminal and computer. (2) Using a battery charger to charge batteries in advance. (3) Connecting the USB cable to your terminal and use a power supply. When your batteries are fully charged, the Charger LED turns to solid red.
Note The triangle mark should be face up when you want to plug connecter in to PI series.
2 Get started This chapter provides information about how to work with your terminal and make connection to computer. 2.1 Set up your terminal 1. Choose one to power on your terminal Open the battery cover and Install two AA batteries. Connect your terminal to your computer using USB or RS-232 cable with adapter. 2. Press the Power key to turn on your terminal.
2.2 User interface Menu Options Status bar Input method Power source Time Wireless Item Menu Description Current menu title Options Items in the menu. Status bar It displays the information about your terminal. Input method The way you enter data. You can enter numbers, lowercase or uppercase characters. Time The current time.
Item Wireless communication Description When you open Bluetooth or Wi-Fi function, it displays an icon without waves. If connection is successful, the icon will show waves. Power source If your terminal is connected to a direct power supply (USB or RS-232), it displays a plug icon; if it is running on batteries, it displays a battery icon.
2.3 Connection PI series have four interfaces to connect: USB, RS232, Bluetooth and WI-FI. Each one can choose two ways as below. Remote link: It is a unique protocol from Argox development. Visit Argox website below to download application. http://www.argox.com/content2011.php?sno=0000033 Linking port: Transmit raw data 1 Byte a time. Developer can set four interfaces to their own connection. Important Remote link has to use Argox application, such as PhoenixVoler or Everlink from Argox.
2.3.1 Remote link connection This section will show how to link PI series to PC with “Remote link” and enter “Message menu” to send message when the connection successful. Use Remote link to connect PC with USB Step 1. After link USB cable between PI series and PC, press “Power” key to open PI series. Step 2. Move curse to “Remote Link” and press “ENT” key. Step 3. Enter “Remote I/F Select” and Choose “USB”.
Step 4. Choose “Connect”. Step 5. In PhoenixVoler or Everlink, Click Comm setup will show the model number. Successfully connected to PC.
Message Menu Everlink, ControlCenter and PI series can send message to PI series. Press “Fn”+”^” key to enter Message Menu. Read priority Msg.: It shows the priority message you receive. Read Msg.: It shows the message you sent. Send Msg.: To Everlink: “Send to” is 9000 To ControlCenter: “Send to” is 9001 To otherPI series device: “Send to” default depends on SN last four number. To change ID, refer to “Equipment ID” in System menu. Important Sending message rely on Everlink.
2.4 Attach the hand strap Sometimes you may need to do something and can’t hold your terminal on your hand. Or, you might accidentally drop your terminal between uses. Attach the hand strap is a useful way to resolve these issues. You can wrap the strap around your hand to secure it to your hand, or hang it on your hand to have both hands free to do other things. To attach the hand strap, do this: 1. Pinch the small loop and thread it into the two square holes under the battery cover.
2. Thread the big loop into the small loop, and pull the big loop to tie a knot. Important Use hand strap when you collect barcode in case drop accident. PI series might shut down to protect data after drop.
3 Controls and settings PI series offers three different layer menus. User Menu is for general users, System Menu is for supervisors or managers, and Supervisor Menu is for system administrators or engineers. Besides, press Fn+^ can enter Message Menu This chapter provides information about these menus. 3.1 User Menu User Menu includes three frequently used settings. You can use them to run your program, connect your terminal to a computer or other device, or display your terminal’s information.
3.1.1 Run Program It shows the program you download from your computer. To run a program, just select it and press ENT. If there’s no program, it will tell you “No program file.” For more information about how to connect to a computer and download programs from it, see PhoenixVoler or Everlink User guide. 3.1.2 Remote Link It is for you to connect your terminal with Everlink or PhoenixVoler to computer. ■ Connect It connects your terminal to computer after you select an interface.
■ Remote I/F Select It provides interfaces, including COM port, USB, Bluetooth and WI-FI. To connect your terminal, do this: 1. Select Remote Link > Remote I/F Select > COM port/USB/Bluetooth/WI-FI. 2. Go up one level in the menu and select Connect. Note If you want to connect via Bluetooth or WI-FI, you need to enter Supervisor Menu and set up Bluetooth connection or WI-FI connection first. After completing the setting, you can connect your terminal from User Menu Connect. 3.1.
Note Make sure you turn on the decode function(barcode default). 3.1.4 Information It displays your terminal’s information. IPL BOOT Kernal Scanner SN DefLang The IPL version. The boot version. The kernel version. The scanner’s firmware version. The serial number. The display language.
3.2 System Menu Under System Menu, you can change system settings to meet your need and run some tests to see if your terminal is working properly. Press key 3 + 9 + Power to enter system menu. 3.2.1 Remote Link See the description in Remote Link in User Menu. 3.2.
It provides the disk information, including the free, used and total disk space. By default, your terminal has two disks: C and D. C RAM For data memory D Flash For system and user’s application 3.2.3 Timer setting ■ Set date & time You can set date and time here. ■ Set time format You can set the time format here. It provides the 12-hour or 24-hour clock and only display in Status Bar.
3.2.4 Environment It provides settings for you to adjust different workplace or match your preference. ■ LCD contrast It determines the contrast ratio. The bigger the number, the lower the contrast (the darker the screen).1~10 ■ Backlight timer It determines how long the backlight stays on after you press a key.1~65535. Set 0 will always on. ■ Auto off timer It turns off your terminal after a certain amount of time elapsed. The unit of time is the second.
■ Key click You can turn on or turn off the sound of keypad. ■ Vibration It determines how long your terminal vibrates. The unit is 0.1 second, range is 1~255. Set 0 will turn it off. 3.2.5 Test It provides various tests for you to check your terminal system. ■ Memory test It checks if the memory can be written and read properly. Note that this test removes all data stored in the memory, so remember to save your files in advance. ■ Buzzer test It checks if the buzzer can make sound properly.
high to low and from low to high. If the sound is played smoothly, it means the buzzer works properly, otherwise the buzzer may have some issues. ■ LCD & LED test It checks if the LCD display has bad pixels. ■ Keypad test It checks if the keypad works properly when you press it. ■ Linking port test It checks if the port works properly. You need to set a port to run this test. For more information about the port setting, see the description in Setting in Supervisor Menu.
3.2.6 System info See the description in Information in User Menu.
3.3 Supervisor Menu (1+3+0+PWR)Supervisor Menu provides advanced settings for you to configure. To protect the settings from being changed easily, you need to enter a password to access the menu. By default, the password is five zeros (00000).
3.3.1 Remote Link It is for you to connect your terminal with Everlink or PhoenixVoler to computer. ■ Connect It connects your terminal to computer after you select an interface. ■ Remote I/F Select It provides interfaces, including COM port, Bluetooth and WI-FI. ■ Remote I/F Set It has three options: ∙ COM port You can select a baud here.
∙ Bluetooth It has three options: 1. Bluetooth setting: (1) Device name: Your terminal’s name. By default, the name is the serial number. (2) PIN code: The passkey for a Bluetooth connection. By default, the code is four zeros (0000). (3) Security mode: It has two options. a. Security: Your terminal will ask other devices to enter a PIN code when they try to connect to your terminal. b. Encryption: It encrypts the connection to prevent data theft.
entering its Bluetooth MAC address. 2. Bluetooth test: You can use this option to test the Bluetooth connection after your terminal connects to a device. 3. Bluetooth info: It displays Bluetooth information, including the local address, device name and link address. ∙ WI-FI It has three options 1. Setting (1) WI-FI SSID: a. Set by search: Search WI-FI signal in the neighborhood. b. Set by keyin: Type New SSID to connect the WI-FI you prefer. (2) Network: It is the same as computer network.
(5) Power Saving: If Disable, WI-FI module will always awake to transmit data. Otherwise, WI-FI will automatically turn off. 2. TCP Test: Test WI-FI connection, the process need to wait about 3~15 seconds. PI series will show the connect success of fail on the screen. 3. Information: It displays WI-FI information. (1) Remote port: show the page is under remote port. (2) MAC: Show MAC address after you connect. (3) DHCP: The status is Enable or Disable. (4) rIP: Current remote IP Address.
It formats a disk in your terminal. The system will ask you to confirm if you want to format, because it will remove all data stored in the disk. ■ Format C Format the C disk. ■ Format D Format the D disk. 3.3.3 Setting It offers a variety of settings that you can change to meet your need. ■ Equipment ID Your terminal’s ID. The default ID is four zeros (0000). You can replace it with a new ID. The ID needs to be a 4-digit number. ■ BIOS Password It is the password of Supervisor Menu.
■ Environment It provides settings for you to adjust to adapt to different workplaces or match your preference. For the first five options, see the description in Environment in System Menu. ∙ Power on It determines the screen displayed in User Menu after you turn on your terminal. 1. Resume: The system displays the last screen you visited in User Menu every time you turn on your terminal. 2. Reset: The system displays the default screen in User Menu every time you turn on your terminal.
1. Transmission: It has two modes: Proprietary ID or AIM ID. You can choose either of them. Proprietary ID is defined by Argox. AIM ID is defined by the AIM organization. 2. Position: You can insert the code ID before or after the bar code data. ∙ Invert Image When you turn on this feature, you can scan both regular and inverted bar codes. ∙ Preamble bar code. ∙ Postamble code.
8. UPC-E 9. Industrial 25 10. Interleaved 25 11. Standard 25 12. MSI-Plessey 13. UK-Plessey 14. RSS 14 15. RSS Limited 16. RSS Expanded 17. CODABAR 18. Telepen 19. Matrix 2 of 5 20. China Post 21. Pharmacode ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ■ Language You can change the language for the system to display items in the user interface. It has two options: English, TC (Traditional Chinese) and SC(Simple Chinese). ■ Linking port You can decide which port you want to use and configure its settings.
interface. ∙ Port IF select It has four ports. Select one of them and choose its interface. You can choose COM, USB, Bluetooth and WI-FI. If you don’t want to use interface, choose None. ∙ Port IF setup It provides the settings of COM, Bluetooth and WI-FI. For more information about the settings, see Remote Link in Supervisor Menu. ∙ Port info It displays the port information. Press Up Arrow and Down Arrow to check different ports. 重要 Linking port is for development usage and transmit raw data.
3.3.4 Information It displays your terminal’s information. IPL The IPL version. BOOT The boot version. Kernal The kernel version. Scanner The scanner’s firmware version. SN The serial number. HW Ver. The PCBA (Printed Circuit Board Assembly) version. HW Int. The hardware version. DefLang The display language.
4 Applications Argox provides multiple applications for communication and developments as below: Communication PhoenixVoler Everlink Control center Upload and Download firmware or application easily. Recommend developer. Manage multiple PI series with files transmission, message sending and history data function. Remote-end of manage program can link multiple Everlink and provide Cloud operation.
5 Troubleshooting 5.1 Hardware issues Speaker is not working or volume is too low. ■ Make sure the speaker hole is not blocked. ■ Test is in the system menu, use Test to check speaker. Keypad does not response. ■ Test is in the system menu, use Test to check keypad. ■ The system might be crush. Use Scan + Power key to warm reset or cold reset (hold 5 seconds). My terminal keeps turning itself off or can not open. ■ If you’re using batteries, check them and see if they need to be charged.
5.2 Communication issues Receive or transmit problem on USB ■ Check USB connector is plugged correctly. ■ Check Remote Link set is USB and select the right PI series name on computer. ■ Restart PI series and unplug the USB and try again. Receive or transmit problem on RS-232 ■ Check RS-232 connector is plugged correctly. ■ Check Remote Link set is COM port and select the same port on computer. ■ Restart PI series and unplug the RS-232 and try again.
5.3 Barcode scanning issues Barcode can not be read ■ Change the angle between the bar code and the terminal. ■ Change the distance between the bar code and the terminal. ■ Clean the scanning window slightly of the terminal(make sure without scratch). ■ Enabled the bar code symbology in supervisor menu > 3.Setting > 5.Scanner > 7.Barcode config.
6 Specifications General Characteristics OS Argox Proprietary CPU ARM926EJ-S RAM 16 / 32 MB DRAM ROM 20 / 60 MB Flash Display White gray mono STN LCD 160*160 Indicator LED Blue, Green and Red; Beeper; Vibration Motor Keypad 25 Alpha-Numeric keys (Including 10 function keys, 3 programmable hot keys) Accessory Holder (Standard), Power Supply Dimensions 145.0mm (L) x 55.0mm (W) x 26.
Scanner PI-10x0 PI-11x0 PI-12x0 (coming soon) Scanner system CCD Laser 2D Area imager Resolution 5 mil at PCS 4 mil 5 mil (optional 90% 3 mil) Depth of field 350mm (Code 39, 13 mil, PCS 90%) 254 mm (13 mil) 390 mm (13 mil) Scanning rate 200 scan/sec 100 scan/sec Decode 1D barcode: Code-11、Code-39、Code-93、 capability Code-128、EAN-8、EAN-13、UPC-A、UPC-E、 Industrial 25、Interleaved 25、Standard 25、 MSI-Plessey、UK-Plessey、RSS 14、RSS Limited、RSS Expanded、CODABAR、Telepen、 Matrix 2 of 5、China Pos
Communication PI-1x00 WPAN PI-1x10 PI-1x30 Bluetooth Class2, BT2.1+EDR Bluetooth Class2, BT2.1+EDR Wi-Fi 802.11b/g/n WLAN I/O Interface Expansion Storage USB 2.0 / RS-232 USB 2.0 / RS-232 USB 2.
Physical and Environment -10℃ ~ 60℃ / 14F ~ 140F Operating Temperature Storage Temperature -20℃ ~ 70℃ / -4F ~ 158F Humidity 1) Operating: Non-condensed 10 ~ 90% 2) Storage: Non-condensed 5 ~ 95% Impact Resistance 1) Terminal 1.5M/5ft, Holder 0.
Appendix A Skywalker Reader Default (*) Command1 Command2 LED indication Indication Option/Limitation Disable Enable * Buzzer indication Disable Enable * Preamble Disable * transmission Enable Postamble Disable * transmission Enable Code ID position Before code data * After code data Code ID transmission Disable * Proprietary ID Transmission AIM ID Code length Disable * transmission Enable Code name Disable * transmission Enable Disable * Case conversion Upper case Lower case 58
0~9 Scan Double confirm 0* 0 ~ 99 Global min. code 4* length 0 ~ 99 Global max. code 63 * length Disable * Inverted image scan Enable 0* String setting Prefix characters 0x00 ~ 0xff ASCII setting code 12 characters. 0* Suffix characters 0x00 ~ 0xff ASCII setting code 12 characters. 0* Preamble characters 0x00 ~ 0xff ASCII settings code 12 characters. 0* Postamble characters 0x00 ~ 0xff ASCII settings code 12 characters.
Disable * Code 11 Read Enable Disable/Disable Check-sum transmit Disable/One digit * /verify Disable/Two digits Enable/One digit Enable/Two digits 0 ~ 64 Max. code length 0* 0 ~ 64 Min. code length 0* 0 ~ 15 Truncate leading 0* 0 ~ 15 Truncate ending 0* Code ID setting 0x00 ~ 0xff ASCII code(1 or 2 bytes) Code 39 Read Disable Enable * Check-sum transmit /verify Disable/Disable * Disable/Enable Enable /Enable Max.
0* Min. code length 0 ~ 64 1* Truncate leading 0 ~ 20 0* Truncate ending 0 ~ 15 0* <*> Code ID setting 0x00 ~ 0xff ASCII code(1 or 2 bytes) Standard * Format Full ASCII Disable * Start/stop Enable transmission Disable * Code 93 Read Enable Disable/Disable Check-sum transmit Disable/Enable * /verify Enable /Enable 0 ~ 64 Max. code length 0* 0 ~ 64 Min.
Truncate leading 0* 0 ~ 15 Truncate ending 0* <&> Code ID setting 0x00 ~ 0xff ASCII code(1 or 2 bytes) Disable Code 128 Read Enable * Disable/Disable Check-sum transmit Disable/Enable * /verify Enable /Enable 0 ~ 64 Max. code length 0* 0 ~ 64 Min. code length 1* 0 ~ 15 Truncate leading 0* 0 ~ 15 Truncate ending 0* <#> Code ID setting 0x00 ~ 0xff ASCII code(1 or 2 bytes) Standard * Format UCC.
UCC/EAN 128 ID 0x00 ~ 0xff ASCII setting code(1 bytes) 0x1D * Concatenation code 0x00 ~ 0xff ASCII code(1 bytes) Codabar Disable * Read Enable Disable/Disable * Check-sum transmit Disable/Enable /verify Enable /Enable 0 ~ 64 Max. code length 0* 0 ~ 64 Min.
Disable * Start/stop Enable transmission Disable EAN 8 Read Enable * Disable Check-sum Enable * transmission 0 ~ 15 Truncate leading 0* 0 ~ 15 Truncate ending 0* Code ID setting 0x00 ~ 0xff ASCII code(1 or 2 bytes) None * Supplement digits 2 digits 5 digits 2, 5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All None * Truncation/expansion Truncate leading zero 64
Expand to EAN 13 Disable * Expansion Enable Disable EAN 13 Read Enable * Disable Check-sum Enable * transmission 0 ~ 15 Truncate leading 0* 0 ~ 15 Truncate ending 0* Code ID setting 0x00 ~ 0xff ASCII code(1 or 2 bytes) None * Supplement digits 2 digits 5 digits 2, 5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All Disable * ISBN/ISSN conversion 65 Enable
Disable * Industrial 2 of Read Enable 5 0 ~ 64 Max. code length 0* 0 ~ 64 Min. code length 0* 0 ~ 15 Truncate leading 0* 0 ~ 15 Truncate ending 0* Code ID setting 0x00 ~ 0xff ASCII code(1 or 2 bytes) Read Disable Interleaved 2 Enable * of 5 Disable/Disable * Check-sum transmit Disable/Enable /verify Enable /Enable 0 ~ 64 Max. code length 0* 0 ~ 64 Min.
Truncate ending 0* Code ID setting 0x00 ~ 0xff ASCII code(1 or 2 bytes) Disable * Standard 2 of Read Enable 5 Disable/Disable * Check-sum transmit Disable/Enable /verify Enable /Enable 0 ~ 64 Max. code length 0* 0 ~ 64 Min.
N/Mod 10,10 N/mod 11,10 Y/ Mod10 Y/ Mod 10,10 Y/ Mod 11/10 0 ~ 64 Max. code length 0* 0 ~ 64 Min. code length 0* 0 ~ 15 Truncate leading 0* 0 ~ 15 Truncate ending 0* <@> Code ID setting 0x00 ~ 0xff ASCII code(1 or 2 bytes) Disable * UK Plessey Read Enable Disable/Disable Check-sum transmit Disable/Enable * /verify Enable /Enable 0 ~ 64 Max.
Min. code length 0* 0 ~ 15 Truncate leading 0* 0 ~ 15 Truncate ending 0* <@> Code ID setting 0x00 ~ 0xff ASCII code(1 or 2 bytes) Disable * Telepen Read Enable Disable/Disable * Check-sum transmit Disable/Enable /verify Enable /Enable 0 ~ 64 Max. code length 0* 0 ~ 64 Min.
Format Full ASCII Disable UPCA Read Enable * Disable Check-sum Enable * transmission 0 ~ 15 Truncate leading 0* 0 ~ 15 Truncate ending 0* Code ID setting 0x00 ~ 0xff ASCII code(1 or 2 bytes) None * Supplement digits 2 digits 5 digtis 2, 5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All None Truncate/expansion Truncate leading zero * Expand to EAN 13 Disable 70
UPCE Read Enable * Disable Check-sum Enable * transmission 0 ~ 15 Truncate ending 0* Code ID setting 0x00 ~ 0xff ASCII code(1 or 2 bytes) None * Supplement digits 2 digits 5 digits 2, 5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All None * Truncate/expansion Truncate leading zero Expand to EAN 13 Expand to UPCA Disable * Expansion Enable Disable * UPCE-1 71 Enable
Disable * Matrix 25 Read Enable Disable/Disable * Check-sum transmit Disable/Enable /verify Enable /Enable 0 ~ 64 Max. code length 0* 0 ~ 64 Min. code length 0* 0 ~ 15 Truncate leading 0* 0 ~ 15 Truncate ending 0* Code ID setting 0x00 ~ 0xff ASCII code(1 or 2 bytes) Disable * China post Read Enable 0 ~ 64 Max. code length 11 * 0 ~ 64 Min.
Truncate ending 0* Code ID setting 0x00 ~ 0xff ASCII code(1 or 2 bytes) Disable * RSS 14 Read Enable 0 ~ 15 Truncate leading 0* 0 ~ 15 Truncate ending 0* Code ID setting 0x00 ~ 0xff ASCII code(1 or 2 bytes) Disable * UCC/EAN 128 Enable emulation Disable * RSS Limited Read Enable 0 ~ 15 Truncate leading 0* 0 ~ 15 Truncate ending 0* Code ID setting 0x00 ~ 0xff ASCII code(1 or 2 bytes) Disable * 73
UCC/EAN 128 Enable emulation Disable * RSS Read Enable Expanded 0 ~ 99 Max. code length 99 * 0 ~ 99 Min. code length 1* 0 ~ 15 Truncate leading 0* 0 ~ 15 Truncate ending 0* Code ID setting 0x00 ~ 0xff ASCII code(1 or 2 bytes) Disable * UCC/EAN 128 Enable emulation Disable * Italian Read Enable Pharmacode 39 0 ~ 64 Max. code length 12 * 0 ~ 64 Min.
0 ~ 15 Truncate ending 0*
Code ID setting 0x00 ~ 0xff ASCII code(1 or 2 bytes) Disable * Leading “A” 75 Enable