User’s Manual Argox Handheld Bar Code Scanner Model No.
USING AS-8510/8512 RADIO CRADLE The AS-8510/8512 radio cradle paired with one AS-8510/8512 scanner, builds a Cordless Reading System for the collection, decoding and transmission of barcoded data. It can be connected to a Host PC through an RS232, Keyboard wedge or USB cable and is suited for a single-cradle layout. The LEDs signal of the AS-8510/8512 radio cradle status, as described in the following: BATTERY: Green LED blinking: the batter charge is in progress.
Default setting For each barcode shown as below: Code Type UPC-A UPC-E EAN-13 EAN-8 Code-39 Interleaved 2 of 5 Industrial 2 of 5 Matrix 2 of 5 Codabar Code-128 Code-93 Code-11 MSI/Plessey UK/Plessey Telepen Standard 2 of 5 China Post Italian Pharmacode.
ArgoScan 8510/8512 Specification Model 8510 / 8512 Operational Light Source 635 nm Visible Red LED Optical System 2048 pixel CCD (Charge-coupled device) Depth of Scan Field Up to 600mm (CODE 39, PSC=90%, 20mils) Scanning Width 160mm Scan Speed Resolution 400 scans/sec 0.
Case material ABS (over molded at contact pointed) Cushion material Double injection Cradle interface RS232, Keyboard wedge, USB Electrical Input Voltage 5 VDC ± 10% VDC (Cradle) Power - Operating 5 VDC (Cradle) Power – Standby 5 VDC (Cradle) Current – Operating 132 mA (Cradle) Current – Standby 132 mA (Cradle) Charge Current 340 mA (Cradle) Input Voltage 3.4V ~ 4.2V (Scanner) Power - Operating 3.2V ~ 4.0V (Scanner) Power – Standby 3.4V ~ 4.
Ventilation None required Programming Programming method Manual (Reading special barcode) DOS command through RS-232, Windows configuration program Program upgrade Enabled by built-in flash memory Programmable Code type selection, check digit characteristics selection Decoding option Decoding option Transmitted character delay, Header selection, trailer selection, message suffix, good read beep tone and volume, scanner trigger selection Keyboard emulation type (intermessage delay, keyboard type and
Programming the AS-8510 / 8512 To program the 8510 or 8512, you must scan a series of programming barcode in the correct order. Fold out the back cover of this manual. You will see a table of alphanumeric barcodes, which are used to program the various options presented. To program each option, you must: 1. Scan the Program barcode on the parameter setting part. 2. Enter the option mode by scanning the Option Bar Code (also on the Parameter setting part). 3.
Program Barcode Program Option Bar Code Option Alphanumeric Entry Keyboard Wedge 00* Interface RS-232 01 selection Wand emulation 02 USB 03 Keyboard/RS-232 04 Auto detection Reserved 05 Exit Option Barcode Back Fold Out Exit Barcode Finish barcode 7
Interface Selection This decoder built-in scanner comes in one model and supports interfaces such as keyboard wedge, RS232 serial wedge, wand emulation, and the latest USB interface. In most of the cases, simply selecting an appropriate cable with a device code will work for a specific interface. Interface selection: You can change factory interface default for other type interface. By plugging different cables, setting right interface, then the scanner will be changed to another interface.
Keyboard wedge As a keyboard interface, the scanner supports most of the popular PCs and IBM terminals. The installation of the wedge is a fairly simple process without any changes of software or hardware. Keyboard Type: Select keyboard type connector of your host computer. Scanner must be selected to the appropriate host interface cable converter.
Keyboard wedge Keyboard Layout: The selecting of keyboard layout supports many country languages other than USA keyboard layout. First you need to confirm country language that you desire. In DOS, using command “keyb” to select the desirable keyboard layout or in WINDOWS entry “Control” then pops “Keyboard” to select country at “language” item. For details, please refer to your DOS or WINDOWS user’s manual. Keyboard Speed: By selecting, you can change output speed of scanner to match with host computer.
Keyboard layout USA 00* Belgium 01 Danish 02 France 03 Germany 04 Italian 05 Portuguese 06 Spanish 07 Swedish 08 Switzerland 09 UK 10 Latin American 11 Japanese 12 0-8 00-08 0 : high clock rate 01* Keyboard speed 8 : low clock rate 03 * (8310/8312) Disable 00 Enable 01* Alphabetic key 00* Numeric keypad 01 Function key Numeric key (Num lock state only) Alt+Keypad 11 02 Exit
Keyboard wedge Caps Lock: By selecting Caps lock”ON” or Caps lock”OFF” , scanner can get Caps Lock status. Power-on simulation: All of the PCs check the keyboard status during power-on selftest. It is recommended to Enable function if you are working without keyboard installation. It simulates keyboard timing and pass keyboard present status to the PC during power-on. Inter-character delay: This delay is inserted after each data characters transmitted.
Program Option Bar Code Option Alphanumeric Entry Caps lock”ON” 00 Caps lock”OFF” 01* Disable 00* Enable 01 00-99 msec 00-99 Caps lock Power-on simulation 02* Inter-character delay 00-99 10 msec 00-99 10* Block transmission delay Exit 13
RS-232 CTS: Clear To Send (Hardware Signal) RTS: Request To Send (Hardware Signal) Xon: Transmit On (ASCII Code 11 16) Xoff: Transmit Off (ASCII Code13 16) Flow control: None-The communication only uses TxD and RxD signals without regard for any hardware or software handshaking protocol. RTS/CTS-If the scanner wants to send the barcode data to host computer, it will issue the RTS signal first, wait for the CTS signal from the host computer, and then perform the normal data communication.
Program Option Bar Code Option Alphanumeric Entry Flow control None 00* RTS/CTS 01 Xon/Xoff 02 ACK/NAK 03 00-99 (msec) 00-99 00* Inter-character delay 00-99 (10 msec) 00-99 00* Block transmission delay 00-99 (100 msec) 00-99 20* Response delay Exit 15
Program Option Bar Code Option Alphanumeric Entry Baud rate Parity 300 BPS 00 600 BPS 01 1200 BPS 02 2400 BPS 03 4800 BPS 04 9600 BPS 05* 19200 BPS 06 38400 BPS 07 None 00* Odd 01 Even 02 8 bits 00* 7 bits 01 One bit 00* Two bits 01 Data bit Stop bit Exit 16
Scan Scanning mode: Good-read off-The trigger button must be pressed to activate scanning. The light source of scanner stops scanning when there is a successful reading or no code is decoded after the Stand-by duration elapsed. Momentary-The trigger button acts as a switch. Press button to activate scanning and release button to stop scanning. Alternate -The trigger button acts as a toggle switch. Press button to activate or stop scanning.
Notes 1): Please set the min/max length if you have special demand for individual barcode. 2): Include the Check sum digits if you want to set Global min/max code length.
00-63 00-63 04* Global min. code length Scan Inverted image scan: Set Enabled the scanner will scan Exit both black/white barcode with white/black background. CTS trigger: This operation enabled an external device to control scanning. The CTS trigger is controlled by apply an external trigger signal to the CTS input. When active, this signal causes scanning to begin as the scanner’s trigger was depressed. Power saving: Place the scanner in a idle state during idle priced to optimize power usage.
Disable 00* Enable 01 Disable 00* Enable 01 Disable 00* Enable 01 Disable 00* 30 second 01 60 second 02 90 second 03 120 second 04 150 second 05 180 second 06 Continue 07 LED ‘’on’’ 00* LED ‘’off’’ 01 Inverted image scan CTS trigger *7AJ* Power saving (For 8310/8312) Position indication *7AL* Stand mode selection (For 8310/8312) Exit 20
Indication Power on alert: After power-on the scanner it will generate an alert signal to indicate a successful self -test. LED indication: After each successful reading, the LED above the scanner will light up to indicate a good barcode reading. Beeper indication: After each successful reading, the scanner will beep buzzer to indicate a good barcode reading, and its Beep loudness , Beep tone freq. and Beep tone duration are adjustable. Beep loudness/Beep tone freq.
Program Option Bar Code Option Alphanumeric Entry Disable 00 Enable 01* Disable 00 Enable 01* Disable 00 Enable 01* 00-07 00-07 Power on alert LED indication Beeper indication 07* Beep loudness 00-99 (100Hz) 00-99 26 * Beep tone freq.
UPCA Read: Format Leading Data Digits Check Zero (11 Digits) Digit Check -sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: The leading or ending digits of barcode data characters can be truncated when these values are set to non-zero. It will beep instead of reading anything when the trunc ate value is more than the barcode data digits or the value of Truncate Leading is overlapped with that of the Ending. The maximum value of truncate digits is 15.
Disable 00 Enable 01* Disable 00 Enable 01* 0-15 00-15 Check-sum verification Check-sum transmission 00* Truncate leading 0-15 00-15 00* Truncate ending 00-ffH ASCII 00-ffH code < A >* 00-44 00-44 Code ID setting 00 * Insert group selection Exit 24
UPCA Supplement digits: The Supplement digits barcode is the supplemental 2 or 5 characters for WPC code. Format Leading Data Digits Check Zero (11 Digits) Digit Supplement Digits 2 or 5 or UCC / EAN 128 Truncation / Expansion: The leading “0” digits of UPCA data characters can be truncated w hen the function is enabled.
None 00? 2 digits 01 Supplement digits 5 digits 02 (For 8310/8312) 2,5 digits 03 UCC/EAN 128 04 2, UCC/EAN 128 05 5, UCC/EAN 128 06 All 07 Disable 00 Enable 01* None 00 Truncate leading 01* Truncation/ Expansion (For 8110/8210) Truncation/ zero Expansion (For Expand to EAN13 02 8150/8310/8312) The Exit 26
UPCE Read: Format Leading Data Digits (6 Check Zero Digits) Digits Check -sum verification: The checksum of EAN-13 is optional and made as the sum of the numerical value of the data digits. Check -sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA.
Disable 00 Enable 01* 0-15 00-15 Check-sum transmission 00* Truncate leading 0-15 00-15 00* Truncate ending 00-ffH ASCII 00-ffH code < E >* Code ID setting Exit 28
UPCE Insertion group selection: Refer to Insertion group selection of UPCA. Supplement digits: Format Leading Zero Data Digits Check (6 Digits) Digit Supplement Digits 2 or 5 or UCC/EAN 128 Expansion: The expansion function is used only for UPCE and EAN-8 code reading. It extends to 13-digits with “0” digits when the feature is enabled. Example: Barcode “0123654” Output: “0012360000057” UPCE-1: To enable scanner to read UPCE with leading digit 1.
None 00* 2 digits 01 Supplement digits 5 digits 02 (For 8310/8312) 2,5 digits 03 UCC/EAN 128 04 2, UCC/EAN 128 05 5, UCC/EAN 128 06 All 07 Disable 00* Enable 01 None 00* Truncate leading 01 Truncation/Expansion (For 8110/8210) Truncation/Expansion zero (For 8150/8310/8312) Expand to EAN13 02 Expand to UPCA 03 Disable 00* Enable 01 Disable 00* Enable 01 Expansion *OAM* UPCE-1 Exit 30
EAN-13 Read: Format Data Digits (12 Digits) Check Digits Check -sum verification: The checksum of EAN-13 is optional and made as the sum of the numerical value of the data digits. Check -sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA.
0-15 00-15 00* Truncate leading 0-15 00-15 00* Truncate ending Exit 32
EAN-13 Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Supplement digits: Format Data Digits (12 Digits) Check Digits Supplement Digits 2 or 5 or UCC / EAN 128 ISBN/ISSN: The ISBN (International Standard Book Number) and ISSN (International Standard Serial Number) are two kinds of barcode for book and magazines. The ISBN is 10 digits with leading “978” and the ISSN is 8 digits with leading “977” of the “EAN-13” symbology.
None 00* 2 digits 01 Supplement digits 5 digits 02 (For 8110/8150/8210) UCC/EAN 128 03 Auto detection 04 None 00* 2 digits 01 Supplement digits 5 digits 02 (For 8310/8312) 2,5 digits 03 UCC/EAN 128 04 2, UCC/EAN 05 128 06 5, UCC/EAN 07 128 All Disable 00* Enable 01 ISBN/ISSN conversion Exit 34
EAN-8 Read: Format Data Digits (7 Digits) Check Digits Check -sum verification: The checksum of EAN-8 is optional and made as the sum of the numerical value of the data digits. Check -sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
Disable 00 Enable 01* 0-15 00-15 Check-sum transmission 00* Truncate leading 0-15 00-15 00* Truncate ending Code ID setting Two characters 00-ffH, 00-ffH 00-ffH ASCII < FF > * code 00-44 00-44 00 * Insert group selection Exit 36
EAN-8 Supplement digits: Format Supplement Digits 2 or 5 or UCC/EAN 128 Truncation / Expansion: Refer to Truncate Leading zero of UPCE. Expansion: Refer to Expansion of UPCE.
Disable 00* Enable 01 None 00* Truncate leading 01 Truncation / Expansion (For 8110/8210) Truncation / zero Expansion Expand to EAN13 02 Disable 00* Enable 01 (For 8150 /8310/8312) Expansion Exit 38
Code 39 Read: Format Start Data Digits Checksum End “★” ( Variable) (Optional) “★” Check -sum verification: The checksum of Code-39 is optional and made as the sum module 43 of the numerical value of the data digits. Check -sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Each symbology has own Max./Min. Code Length. They can be set to qualify data entry. If their Max./Min. Code Length is zero, the Global Min./Max. Code Length is in effect.
Disable 00 Enable 01* Disable 00* Enable 01 Disable 00* Enable 01 00-64 00-64 Read Check-sum verification Check-sum transmission 00* Min.
Code 39 Insertion group selection: Refer to Insertion group selection of UPCA. Format: The Full ASCII Code-39 is an enhanced set of Code-39 that is the data with total of 128 characters to represent Full ASCII code. It is combined one of the digits +, %, $ and/ with one of the alpha digits (A to Z). Append: This function allows several symbols to be concatenates and be treat as one single data entry. The scanner will not transmit the embedded appending code (space for Code-39).
Standard 00* Full ASCII 01 Disable 00* Enable 01 Disable 00* Enable 01 Format Append Start/end transmission Exit 42
Interleaved 2 of 5 Read: Format Data Digits (Variable) Checksum (Optional) Check -sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check -sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA.
Disable 00* Enable 01 00-64 00-64 Check-sum transmission 00* Max. code leading 00-64 00-64 00* Min.
Industrial 2 of 5 Read: Format Data Digits (Variable) Checksum (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry Disable 00* Enable 01 00-64 00-64 Read 00* Max. code length 00-64 00-64 00* Min.
0-15 00-15 00* Truncate leading 0-15 00-15 00* Truncate ending 00-ffH ASCII 00-ffH code < i >* 00-44 00-44 Code ID setting 00* Insert group selection Exit 46
Matrix 2 of 5 Eur Read: Format Data Digits Checksum (Variable) (Optional) Checksum Verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
Disable 00* Enable 01 00-64 00-64 Checksum Transmission 00* Max. code length 00-64 00-64 00* Min.
Codabar Read: Format Start Data Digits (Variable) Checksum (Optional) End Checksum Verification: The checksum is made as the sum module 16 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA.
Disable 00* Enable 01 00-64 00-64 Checksum Transmission 00* Max. code length 00-64 00-64 00* Min.
Codabar Insertion group selection: Refer to Insertion group selection of UPCA. Start/End type: The Codabar has four pairs of Start/End pattern; you may select one pair to match your application. Start/End Transmission: Refer to Start/End Transmission of Code 39.
Code-128 Read: Format Data Digits Checksum (Variable) (Optional) Checksum Verification: The checksum is made as the sum module 103 of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted.
Code-128 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Format: The Code-128 can be translated to UCC/EAN-128 format if it starts with FNC1 character. The first FNC1 will be translated to “ ]C1” ,and next to be a field separator code as (1D16).
0-15 00-15 00* Truncate leading 0-15 00-15 00* Truncate ending 00-ffH ASCII 00-ffH code < # >* 00-44 00-44 Code ID setting 00* Insert group selection Standard 00* UCC/EAN-128 01 Format Exit 54
Code-128 Append: When the function is enabled, it won't show the data immediately if scanner read the barcode includes FNC2 code. It will show all data until it read the barcode, which doesn't have FNC2 code. UCC/ EAN 128 ID setting: To setting the code ID for UCC/EAN-128 output format. Field separator code: This feature is only used for UCC/EAN-128 format. This Field separator code means you can reassign second or after a FNC1 for your usage. The default of ASCII code is (1D16).
Code-93 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The checksum is made as the sum module 47 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted.
Code-93 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry 00-64 00-64 00* Max. code length 00-64 00-64 00* Min.
00-ffH ASCII 00-ffH code < & >* 00-44 00-44 Code ID setting 00* Insert group selection Exit 58
Code-11 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The checksum is presented as the sum module 11 of all data digits. Checksum Transmission: By setting Enable, checksum1 and checksum2 will be transmitted upon your selected checksum verification method. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA.
Disable 00* Enable 01 00-64 00-64 Checksum Transmission 00* Max. code length 00-64 00-64 00* Min.
MSI/plessey Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The MSI/Plessey has one or two optional checksum digits. The checksum is presented 3 kinds of method Mod10, Mod10/10 and Mod 11/10. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum1 and checksum2 will be transmitted upon your selected checksum verification method. Max./Min. code length: Refer to Max.
Mod 11/10 03 Disable 00* Enable 01 00-64 00-64 Checksum Transmission 00* Max. code length 00-64 00-64 00* Min.
UK/plessey Read: Format Data Digits Checksum1+2 (Variable) (Optional) Checksum Verification: The UK/Plessey has one or two optional checksum digits. The checksum1 and chec ksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA.
Disable 00* Enable 01 00-64 00-64 Checksum Transmission 00* Max. code length 00-64 00-64 00* Min.
Telepen Read: IATA (International Air Transport Association). Checksum Verification: The checksum is presented as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
00-64 00-64 00* Max. code length 00-64 00-64 00* Min.
Standard 2 of 5 Read: Format Data Digits (Variable) Checksum1 (Optional) Check -sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check -sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA.
*JAC* Disable 00* Enable 01 00-64 00-64 Check-sum transmission 00* Max. code length 00-64 00-64 00* Min.
China Post Read: Format Data Digits (Variable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry Disable 00* Enable 01 00-64 00-64 Read 11* Max. code length 00-64 00-64 11* Min.
0-15 00-15 00* Truncate leading 0-15 00-15 00* Truncate ending 00-ffH ASCII 00-ffH code < t >* 00-44 01-44 Code ID setting 00* Insert group selection Exit 70
Italian Pharmacode Read: Format Data Digits (Variable) Checksum1 (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Leading “A”: If this function is enabled, each prefix of data shall be A.
00-64 00-64 09* Min.
Code-16K Only the 8210 / 8312 can decode Code-16K. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
PDF-417 Only the 8512 can decode PDF-417. Truncate leading/ending: Refer to Truncate leading/ending of UPCA.
PDF-417 Only the 8512 can decode PDF-417. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA.
String setting Prefix characters: Up to 22 ASCII characters may be sent before data digits. Prefix Data Digits Suffix Suffix characters: Up to 22 ASCII characters may be sent after data digits.
String setting Preamble/ Postamble characters: They are appended to the data automatically when each barcode is decoded. Example: Add a prefix/suffix or preamble/postamble for all symbologies. In this example, you are sending a $ symbol as a prefix for all symbologies. Steps: 1) Scan Programming and Prefix characters setting barcode. 2) Use the ASCII code table to find the value of $→24. 3) Scan 2 and 4 from the barcode on the fold out back page. 4) Scan Finish from the barcode on the fold out page.
None 00* 1-22 characters 00-ffH ASCII Preamble characters code setting None 00* 1-22 characters 00-ffH ASCII Postamble code characters setting None 00* 1-22 characters 00-ffH ASCII Insert G1 characters code setting None 00* 1-22 characters 00-ffH ASCII Insert G2 characters code setting None 00* 1-22 characters 00-ffH ASCII Insert G3 characters code setting None 00* 1-22 characters 00-ffH ASCII Insert G4 characters code setting 78 Exit
Transmission Preamble transmission: By setting Enable, Preamble will be appended before the data transmitted. Postamble transmission: By setting Enable, Postamble will be appended after the data is transmitted. Insert data group 1-4 position: The scanner offers 4 positions to insert among the symbol. The position default value is “00” to indicate no character insertion. Beside, make sure insertion positions are not greater than the symbols; otherwise the insertion data is not effective.
00-63 00-63 (00: no insertion) 00* 00-63 00-63 (00: no insertion) 00* 00-63 00-63 (00: no insertion) 00* 00-63 00-63 (00: no insertion) 00* Before code data 00* After code data 01 Insert data group 1 position Insert data group 2 position Insert data group 3 position Insert data group 4 position Code ID position Exit 80
Transmission Code ID transmission: If your application is needed to transmit Code ID, you must set this to Proprietary ID or AIM ID. Code length transmission: A number of data digits can be transmitted before the code data when Enable is selected. The total length of the barcode is the number of barcode data except Truncate Leading/Ending Digits. And the length is a number with two digits.
Disable 00* Enable 01 Disable 00* Enable 01 Disable 00* Upper case 01 Lower case 02 Code length transmission Code name transmission Case conversion *For barcode data only Exit Format of barcode data transmission: Prefix Name Preamble Code Barcode Length data ID ID Insert groups 82 Postamble Suffix
Test Chart CODABAR-PARA CODE-11 PARA CODE-128 PARA CODE-39 PARA CODE-93 PARA EAN-13 PARA 83
PDF-417 STANDRAD-25 PARA CODE-16K 87549 EAN-8 PARA INDUSTRIAL-25 PARA UPCE PARA 84
INTERLEAVED-25 PARA MATRIX 25 PARA MSI/PLESSEY PARA UPCA PARA UK/PLESSEY PARA RSS Micro-PDF 85
ASCII Code Table L H Note: 0 0 F or keyboard wedge only.
Parameter Setting List Program Barcode standard parameter setting list If you wish to display the current configuration of your AS-8110/8150/8210/8310, scanner over the host terminal/computer, scan the Barcode standard parameter setting list bar code.
Firmware version list If you wish to display the firmware version, scan the Firmware version list. WARNING: Default value initialization If you wish to return the AS-8110/8150/8210/8310 to all the factory default settings, scan the Default value initialization bar code.
0 A 1 B 2 C 3 D 4 E 5 F 6 7 8 Finish 9 89
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications (including the antennas) made to this device that are not expressly approved by the manufacturer may void the user’ s authority to operate the equipment.
following measures: ---Reorient or relocate the receiving antenna. ---Increase the separation between the equipment and receiver. ---Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ---Consult the dealer or an experienced radio/TV technician for help. RF Exposure Statement For cradle This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
OPERATION MANUAL Interface: Please link the applicable interface cable to the PC and the Cradle POWER: plug in via the Cradle (First link the interface cable to the PC and the Cradle, then switch on the Cradle) Application: Receiving the code by using the subsidiary application pattern terminating machine (38400-N-8-1). Connection: After the Scanner Scan the code on the Test Chart, it will then implement the connection of the Cradle. In the meantime, Scanner: The yellow light glitter means on line.
CHARGE: Put the Scanner on the Cradle to charge. The green light is glitter while in charge. After completed charging the light will stay green. A PARAMETER : Please refer to the way of parameter settlement.
Table 2: Scanner LED status Scanner LED Scanner not LED Off working (Sleep mode) On line The yellow light glittering Data deliver The green light success glittering Data deliver failed Scanner low The red light pressure glittering warning while scanning 94 Beep --One short beep One short and one long beeps
根據交通部低功率管理辦法規定: 第十二條 經型式認證合格之低功率射頻電機,非經許可,公 司、商號或使用者均不得擅自 變更頻率、加大功率或變更原設計之特性及功能。 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾 合法通信;經發現有干擾現象 時,應立即停用,並改善至無干擾時方得繼續使 用。 前項合法通信,指依電信規定作業之無線電信。低 功率射頻電機須忍受合法通信 或工業、科學及醫療用電波輻射性電機設備之干 擾。 95