Installation The AS-8000CL Wireless Imager is easy to install and use. Please see the following figure showing the steps to perform the installation. * Note: Turn off the host computer before installation. 1. 2. 3. 4. 5. 6. 7. Connect the interface (I/F) cable to the cradle. Connect the power cord to the cradle. Route the I/F cable and power cord through the notch. Connect the I/F cable to the host computer communication port. Connect the AC adapter to the wall outlet.
How To Scan 1. The imager must be pointed at slight angle to the barcode so that the light reflected off the barcode can be seen by the imager. Do not hold the imager perpendicular to the barcode. 2. The scan line must cross the entire barcode. The imager can not read the barcode data without seeing the entire barcode.
Troubleshooting If the imager can not operate properly, the following checks should be performed: 1. The cradle uses an external power supply and the external power supply has failed, the imager will not operate. Change the power supply with a known good power supply and reset the imager. 2. Verify the interface cable is securely connected to the host computer. Consult your technical support personnel or refer to your host system manual to verify the proper connection for the imager.
3. Verify the interface cable is securely connected to the cradle. 4. Check that the barcodes are of sufficient quality to be recognized by the imager. Wrinkled, smudged, or torn labels will cause the imager to not read at all. Scan a known good label to check the imager’s read operation.
5. Ensure that the cradle’s interface type is compatible with the host computer by consulting your host system manual.
Wireless Connection Linking the imager with the cradle Follow these instructions to link the two devices: 1. Connect power to the cradle. The radio LED (marked with a light symbol) will blink amber and the cradle will beep. 2. To ensure the cradle is unlinked from any other imager, check if the cradle send inquiry beep or not (see Inquiry Beep Control in page 18). 3. Read the link label on the bottom of the cradle with the imager. The imager will sound a good read beep and the LED will flash amber. 4.
Unlinking There are three ways to unlink an imager from a cradle: *$%-$$ZZ%%* Force imager to disconnect and sleep 1. Scan the “Force imager to disconnect and sleep” barcode – Reading the unlink barcode above while the imager is in range of the cradle will break the link between the two devices and allow another imager to link to the cradle. It will also have the imager in Deep Sleep Mode.
Battery Charging The imager contains a 1000mAh Lithium-Ion rechargeable battery. A full charged battery will provide up to 15,000 scans over a 12 hours period. Actual charge life on the imager will depend on the configuration of how the imager is configured via the programmable feature in this manual; in particular, Deep Sleep Mode settings can impact battery life. When the imager is placed in the cradle, the battery will automatically charge.
How to Change the Battery In case the contained battery inside the imager needs to be replaced, please follow the procedures below: 1. Loosen the screw at the bottom of the imager. 2. Take off the battery container out of the imager. 3. Disconnect the battery cable connector from the handle board. 4. Remove the used battery from the battery container. 5. Use a new battery pack and replace the used one.
6. Place the new battery into the battery container. 7. Connect the battery cable connector to the handle board. 8. Put the battery container back to the imager handle. 9. Fasten the screw to the imager. Note: DO NOT touch the PCBA inside the imager when replacing the battery. Improper operation may damage the imager.
Wireless Features The AS-8000CL Wireless model includes an imager and a cradle. When the imager and cradle are linked together, the imager will read and decode barcodes and transmit them via a Wireless radio to the cradle. The cradle will then transmit the barcode data to the host computer over the host cable. The host interfaces available from the cradle are RS-232, Keyboard wedge, and USB as a normal corded imager.
Auto Update When this feature is enabled, an imager and its linked cradle can automatically ensure they stay in sync with regard to firmware and/or configuration. This is accomplished by the linked imager and cradle comparing firmware version number and configuration file check sum. If either is different, the cradle will automatically update the imager with its firmware/configuration.
z Enable firmware auto update only – Allows only firmware updating. *$%-1BA02%%* z Disable auto update – No automatic updates will be performed.
Deep Sleep Mode The WIRELESS imager can be placed into Deep Sleep Mode after this programmed duration (since the units’ last scanning activity). Press its trigger to wake the imager form this mode. z Disable Deep Sleep Mode (Default) *$%-7AJ00%%* z Duration 10 minutes - Force imager into deep sleep mode if there is no barcode read in 10 minutes. *$%-7AJ01%%* z Duration 30 minutes - Force imager into deep sleep mode if there is no barcode read in 30 minutes.
Handcuff Mode (Leash Alarm) When enabled, the Leash Alarm will force the imager to sound an alarm for a preprogrammed length of time to notify if an imager is leaving the immediate vicinity of the cradle. This is especially useful in instances where the imager might inadvertently have been placed in a bag or cart.
Wireless Connectivity The AS-8000CL can be linked to any Bluetooth (BT) enabled device which can accept such a connection with other devices. To implement this feature, user should set the imager to “Cradle/Dongle connection auto detection” first. And then set the PIN code to 0000 assigned to the target Bluetooth device. In this case, the PIN code of the Bluetooth enabled device should be set to 0000 to be identical with your imager.
Wireless Connectivity (continued) User is also allowed to set any four- to six-character PIN code assigned to the target Bluetooth device using the setting procedures below: STATE CODE Cradle/Dongle connection auto detection *$%-1AB01%%* Program *$%+PRO* Begin PIN setting *#PIN* */0* */1* */2* */3* PIN no.
Inquiry Beep Control When the cradle is not linked to an imager, the Radio LED will blink amber and the cradle will beep. This beep can be disabled or reconfigured to sound for different durations by using the following programming barcodes.
z Inquiry beep every 50 seconds *$%-5AJ05%%* z Inquiry beep every 60 seconds *$%-5AJ06%%* z Inquiry beep every 70 seconds *$%-5AJ07%%* 19
Cradle Beep Loudness Control The beep loudness of cradle can be defined with the following levels.
z Level 6 *$%-5AK06%%* z Level 7 *$%-5AK07%%* 21
Additional Features Here list three additional features of AS-8000CL wireless imager for the convenience of use to users. z Download firmware from the cradle *$%-+CP%%* z Download configuration parameters from the cradle *$%-+CC%%* z Force cradle to reset the configuration – This feature will also force imager to reset the configuration to factory default. *$%-+IC%%* Note: To meet the regulation of air transportation, the wireless imager should disconnect with the cradle during shipment.
Default setting For each barcode shown as below: Code Type UPC-A UPC-E EAN-13 EAN-8 Code-39 Interleaved 2 of 5 Industrial 2 of 5 Matrix 2 of 5 Codabar Code-128 Code-93 Code-11 MSI/Plessey UK/Plessey Telepen Standard 2 of 5 China Post Italian Pharmacode.
Specification AS-8000CL Specification Model:AS-8000CL Operational Light Source 630 nm Visible Red LED Optical System 2048 pixel CCD (Charge-coupled device) Depth of Scan Field Up to 260mm (CODE 39, PSC=90%, 20mils) Scanning Width Scan Speed Resolution 50mm wide @ 0mm 30~450 scans/sec 0.
Weight Case material Less than 165g (with a battery) ABS (over molded at contact points) Cushion material Double injection Cradle interface RS232, Keyboard wedge, USB Electrical Input Voltage (Cradle) 5 VDC ± 10% VDC Power - Operating 5 VDC (Cradle) Power – Standby 5 VDC (Cradle) Current – Operating 120 mA (Cradle) Current – Standby 120 mA (Cradle) Charge Current 660 mA (Cradle) Input Voltage 3.4V ~ 4.2V (Imager) Power - Operating 3.2V ~ 4.0V (Imager) Power – Standby 3.4V ~ 4.
Shock (Imager) 1.5m drop onto concrete Shock (Cradle) 0.
Indications of AS-8000CL Imager: Status Link established Loss link (handcuff mode enable Loss link (handcuff mode disable) Hardware fail Program download LED Program checksum fail Data transmitting Green LED Blink once Red LED Orange LED Beeper A special beep Blink Sound like grasshopper Blink twice A special beep Flash Flash Flash High freq. Beep for 300msec ON Data trans. ON for Fail 300msec Data trans. ON for OK 200msec Low battery (<3.
Cradle: Status Green LED Red LED Inquiry Connecting Link ON established Hardware fail Data receiving RF from the status scanner LED Barcode data proof or transmitted Data send to the host Fail Program Flash download Program checksum Fail Idle Charging Blink Battery Battery full ON LED Battery/charger Fail 28 Orange Beeper LED Beeps Blink once a second Blink Flash ON for 0.
Programming the AS-8000CL To program the 8000CL, you must scan a series of programming barcode in the correct order. Fold out the back cover of this manual. You will see a table of alphanumeric barcodes, which are used to program the various options presented. To program each option, you must: 1. Scan the Program barcode on the parameter setting part. 2. Enter the option mode by scanning the Option Bar Code (also on the Parameter setting part). 3.
Program Barcode Program Option Bar Code Option Alphanumeric Entry Keyboard Wedge 00* Interface RS-232 01 selection Wand emulation 02 USB 03 Keyboard/RS-232 04 Auto detection Reserved 05 Exit Option Barcode Back Fold Out Exit Barcode Finish barcode 30
Interface Selection This cradle comes in one model and supports interfaces such as keyboard wedge, RS232 serial wedge, and USB interface. In most of the cases, simply selecting an appropriate cable with a device code will work for a specific interface. Interface selection: You can change factory interface default for other type interface. By plugging different cables, setting right interface, then the cradle will be changed to another interface. However, you must make sure which cable you need.
Keyboard wedge As a keyboard interface, the cradle supports most of the popular PCs and IBM terminals. The installation of the wedge is a fairly simple process without any changes of software or hardware. Keyboard Type: Select keyboard type connector of your host computer. Cradle must be selected to the appropriate host interface cable converter.
Keyboard wedge Keyboard Layout: The selecting of keyboard layout supports many country languages other than USA keyboard layout. First you need to confirm country language that you desire. In DOS, using command “keyb” to select the desirable keyboard layout or in WINDOWS entry “Control” then pops “Keyboard” to select country at “language” item. For details, please refer to your DOS or WINDOWS user’s manual.
Keyboard layout Keyboard speed USA 00* Belgium 01 Danish 02 France 03 Germany 04 Italian 05 Portuguese 06 Spanish 07 Swedish 08 Switzerland 09 UK 10 Latin American 11 Japanese 12 0-8 00-08 0 : high clock rate 03 * 8 : low clock rate Disable 00 Enable 01* Alphabetic key 00* Numeric keypad 01 Function key Alpha/Numeric key (Num lock state only) Alt+Keypad 34 02 Exit
Keyboard wedge Caps Lock: By selecting Caps lock”ON” or Caps lock”OFF”, imager can get Caps Lock status. Power-on simulation: All of the PCs check the keyboard status during power-on selftest. It is recommended to Enable function if you are working without keyboard installation. It simulates keyboard timing and pass keyboard present status to the PC during power-on. Inter-character delay: This delay is inserted after each data characters transmitted.
Program Option Bar Code Option Alphanumeric Entry Caps lock”ON” 00 Caps lock”OFF” 01* Disable 00* Enable 01 00-99 (msec) 00-99 Caps lock Power-on simulation 02* Inter-character delay 00-99 (10 msec) 00-99 10* Block transmission delay Exit 36
RS-232 CTS: Clear To Send (Hardware Signal) RTS: Request To Send (Hardware Signal) Xon: Transmit On (ASCII Code 1116) Xoff: Transmit Off (ASCII Code13 16) Flow control: None-The communication only uses TxD and RxD signals without regard for any hardware or software handshaking protocol. RTS/CTS-If the cradle wants to send the barcode data to host computer, it will issue the RTS signal first, wait for the CTS signal from the host computer, and then perform the normal data communication.
Program Option Bar Code Option Alphanumeric Entry Flow control None 00* RTS/CTS 01 Xon/Xoff 02 ACK/NAK 03 RTS/CTS bracket 04 mode 00-99 (msec) 00-99 00* Inter-character delay 00-99 (10 msec) 00-99 00* Block transmission delay 00-99 (100 msec) 00-99 20* Response delay Exit 38
Program Option Bar Code Option Alphanumeric Entry Baud rate Parity 300 BPS 00 600 BPS 01 1200 BPS 02 2400 BPS 03 4800 BPS 04 9600 BPS 05* 19200 BPS 06 38400 BPS 07 None 00* Odd 01 Even 02 8 bits 00* 7 bits 01 One bit 00* Two bits 01 Data bit Stop bit Exit 39
Pin Assignments 1 2 3 4 5 6 7 8 9 10 10-pin AS Series 10-pin RJ-45 Connector Pin RS-232 1 I/F Keyboard I/F 2 NA NC 3 TXD NC 4 NC CLK / PC 5 GND DATA / PC 6 CTS DATA / KB 7 RXD NC 8 RTS CLK / KB 9 GND GND 10 NC GND 40
Keyboard Wedge PS/2 Connector (To Host Side): Pin Mini-DIN 6P Male Mini-DIN 6P Female 1 DATA / PC DATA / KB 2 NC NC 3 GND GND 4 VCC (+5V) NA 5 CLK / PC CLK / KB 6 NC NC 4 6 3 5 Mini-DIN 6P Female Connector 2 1 Mini-DIN 6P Male Connector 6 4 5 3 2 1 RS-232 DB-9F Connector (To Host Side): Pin Definition 1 NC 2 TXD 3 RXD 4 NC 5 GND 6 NC 7 CTS 8 RTS 9 NC 41 5 4 3 2 1 9 8 7 6
Scan Scanning mode: Good-read off-The trigger button must be pressed to activate scanning. The light source of imager stops scanning when there is a successful reading or no code is decoded after the Stand-by duration elapsed. Momentary-The trigger button acts as a switch. Press button to activate scanning and release button to stop scanning. Alternate-The trigger button acts as a toggle switch. Press button to activate or stop scanning.
Program Option Bar Code Option Alphanumeric Entry Scanning mode Good-read off 00 Momentary 01* Alternate 02 Timeout off 03 Continue 04 Test only 05 01-99 (second) 00-99 06* Stand-by duration 01-99 (10 msec) 01-99 50* Double read timeout Double confirm 00-09 00-09 (00: no double 00* confirm) Exit 43
Scan Global min./max. code length: These are to define the min/ max readable code length of all symbologies. Code length less than min. code length or more than max. code length will not be read. In popular, you can set the same value for both min. and max. reading length to force the fixed length barcode decoded. The values of setting have no effect on certain symbologies with fixed length. You can specify the settings for individual barcode by the min/max code length setting of each barcode.
Program Option Bar Code Option Alphanumeric Entry 00-99 00-99 04* Global min. code length 00-99 00-99 99* Global max.
Indication Power on alert: After power-on the cradle it will generate an alert signal to indicate a successful self-test. LED indication: After each successful reading, the LED above the imager will light up to indicate a good barcode reading. Beeper indication: After each successful reading, the imager will beep buzzer to indicate a good barcode reading, and its Beep loudness, Beep tone freq. and Beep tone duration are adjustable. Beep loudness/Beep tone freq.
Program Option Bar Code Option Alphanumeric Entry Disable 00 Enable 01* Disable 00 Enable 01* Disable 00 Enable 01* 00-07 00-07 (00 - off) 07* 00-99 (100Hz) 00-99 Power on alert LED indication Beeper indication Beep loudness 26* Beep tone freq.
UPCA Format Leading Data Digits Check Zero (11 Digits) Digit Read: Enable or disable the read function. Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: The leading or ending digits of barcode data characters can be truncated when these values are set to non-zero. It will beep instead of reading anything when the truncate value is more than the barcode data digits or the value of Truncate Leading is overlapped with that of the Ending.
Program Option Bar Code Option Alphanumeric Entry Disable 00 Enable 01* Disable 00 Enable 01* 0-15 00-15 Read Check-sum transmission 00* Truncate leading 0-15 00-15 00* Truncate ending 00-ffH ASCII 00-ffH code < A >* Code ID setting Exit 49
UPCA Insertion group number selection: The imager offers max. two insertion groups for one symbology. By setting one or two digits to indicate which insertion group you want to insert. You may refer to Character insertion. The function is to insert specific characters as a group into transmitted data of selected symbologies. Enable the group insertion by selecting the group number. Example: Group 2 → set 02 or 20. Group 1 and 4 → set 14 or 41.
Program Option Bar Code Option Alphanumeric Entry 00-44 00-44 00* Insert group number selection Supplement digits None 00* 2 digits 01 5 digits 02 2,5 digits 03 UCC/EAN 128 04 2, UCC/EAN 128 05 5, UCC/EAN 128 06 All 07 None 00 Truncate leading 01* Truncation/ zero Expansion Expand to EAN13 02 The Exit 51
UPCE Read: Format Leading Data Digits (6 Check Zero Digits) Digits Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA.
0-15 00-15 00* Truncate ending 00-ffH ASCII 00-ffH code < E >* Code ID setting Exit 53
UPCE Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. Supplement digits: Format Leading Data Digits Check Zero (6 Digits) Digit Supplement Digits 2 or 5 or UCC/EAN 128 Expansion: The expansion function is used only for UPCE and EAN-8 code reading. It extends to 13-digits with “0” digits when the feature is enabled. Example: Barcode “0123654” Output: “0012360000057” UPCE-1: Enable imager to read UPCE with leading digit 1.
Supplement digits Truncation/Expansion None 00* 2 digits 01 5 digits 02 2,5 digits 03 UCC/EAN 128 04 2, UCC/EAN 128 05 5, UCC/EAN 128 06 All 07 None 00* Truncate leading 01 zero Expand to EAN13 02 Expand to UPCA 03 Disable 00* Enable 01 Disable 00* Enable 01 Expansion *OAM* UPCE-1 Exit 55
EAN-13 Read: Format Data Digits (12 Digits) Check Digits Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Truncate leading zero: Refer to Truncation / Expansion of UPCA.
0-15 00-15 00* Truncate ending Exit 57
EAN-13 Code ID setting: Refer to page 51 Insertion group number selection of UPCA. Insertion group number selection: Refer to Insertion group selection of UPCA. Supplement digits: Format Data Digits Check (12 Digits) Digits Supplement Digits 2 or 5 or UCC / EAN 128 ISBN/ISSN: The ISBN (International Standard Book Number) and ISSN (International Standard Serial Number) are two kinds of barcode for book and magazines.
Supplement digits None 00* 2 digits 01 5 digits 02 2,5 digits 03 UCC/EAN 128 04 2, UCC/EAN 128 05 5, UCC/EAN 128 06 All 07 Disable 00* Enable 01 00-ffH ASCII 00-ffH code < I >* ISBN/ISSN conversion * M A G * ISBN ID setting Exit 59
EAN-8 Read: Format Data Digits Check (7 Digits) Digits Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA.
0-15 00-15 00* Truncate ending 00-ffH ASCII 00-ffH, 00-ffH code < FF >* 00-44 00-44 Code ID setting 00* Insert group number selection Exit 61
EAN-8 Supplement digits: Format Data Digits Check (7 Digits) Digits Supplement Digits 2 or 5 or UCC/EAN 128 Truncation / Expansion: Refer to Truncate Leading zero of UPCE. Expansion: Refer to Expansion of UPCE.
Disable 00* Enable 01 Expansion Exit 63
Code 39 Read: Format Start Data Digits Checksum End “★” ( Variable) (Optional) “★” Check-sum verification: The checksum of Code-39 is optional and made as the sum module 43 of the numerical value of the data digits. Check-sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Each symbology has own Max./Min. Code Length. They can be set to qualify data entry. If their Max./Min. Code Length is zero, the Global Min./Max. Code Length is in effect.
Disable 00* Enable 01 Disable 00* Enable 01 00-64 00-64 Check-sum verification Check-sum transmission 00* Max. code length 00-64 00-64 00* Min.
Code 39 Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. Format: The Full ASCII Code-39 is an enhanced set of Code-39 that is the data with total of 128 characters to represent Full ASCII code. It is combined one of the digits +, %, $ and/ with one of the alpha digits (A to Z). Append: This function allows several symbols to be concatenates and be treat as one single data entry. The imager will not transmit the embedded appending code (space for Code-39).
Standard 00* Full ASCII 01 Disable 00* Enable 01 Disable 00* Enable 01 Format Append Start/end transmission Exit 67
Interleaved 2 of 5 Read: Format Data Digits Checksum (Variable) (Optional) Check-sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check-sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA.
Disable 00* Enable 01 00-64 00-64 Check-sum transmission 00* Max. code leading 00-64 00-64 00* Min.
Industrial 2 of 5 Read: Format Data Digits Checksum (Variable) (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. Program Option Bar Code Option Alphanumeric Entry Disable 00* Enable 01 00-64 00-64 Read 00* Max. code length 00-64 00-64 00* Min.
0-15 00-15 00* Truncate leading 0-15 00-15 00* Truncate ending 00-ffH ASCII 00-ffH code < i >* 00-44 00-44 Code ID setting 00* Insert group number selection Exit 71
Matrix 2 of 5 Eur Read: Format Data Digits Checksum (Variable) (Optional) Checksum Verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA.
Disable 00* Enable 01 00-64 00-64 Checksum Transmission 00* Max. code length 00-64 00-64 00* Min.
Codabar Read: Format Start Data Digits (Variable) Checksum (Optional) End Checksum Verification: The checksum is made as the sum module 16 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA.
Disable 00* Enable 01 00-64 00-64 Checksum Transmission 00* Max. code length 00-64 00-64 00* Min.
Codabar Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. Start/End type: The Codabar has four pairs of Start/End pattern; you may select one pair to match your application. Start/End Transmission: Refer to Start/End Transmission of Code 39.
Code-128 Read: Format Data Digits Checksum (Variable) (Optional) Checksum Verification: The checksum is made as the sum module 103 of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted.
Code-128 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. Format: The Code-128 can be translated to UCC/EAN-128 format if it starts with FNC1 character. The first FNC1 will be translated to “]C1”,and next to be a field separator code as (1D16).
Truncate leading 0-15 00-15 00* Truncate ending 00-ffH ASCII 00-ffH code < # >* 00-44 00-44 Code ID setting 00* Insert group number selection Standard 00* UCC/EAN-128 01 Disable 00* Enable 01 Format Append Exit 79
Code-128 ISBT enable: This feature is commonly used in a blood bank for identification. ISBT concatenation timeout: This feature is to setup the timeout duration of ISBT concatenation. Field separator code: This feature is only used for UCC/EAN-128 format. This Field separator code means you can reassign second or after a FNC1 for your usage. The default of ASCII code is (1D16). UCC/ EAN 128 ID setting: To setting the code ID for UCC/EAN-128 output format.
Code-93 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The checksum is made as the sum module 47 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted.
Code-93 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. Program Option Bar Code Option Alphanumeric Entry 00-64 00-64 00* Max. code length 00-64 00-64 00* Min.
00-ffH ASCII 00-ffH code < & >* 00-44 00-44 Code ID setting 00* Insert group number selection Exit 83
Code-11 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The checksum is presented as the sum module 11 of all data digits. Checksum Transmission: By setting Enable, checksum1 and checksum2 will be transmitted upon your selected checksum verification method. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA.
Disable 00* Enable 01 00-64 00-64 Checksum Transmission 00* Max. code length 00-64 00-64 00* Min.
MSI/plessey Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The MSI/Plessey has one or two optional checksum digits. The checksum is presented 3 kinds of method Mod10, Mod10/10 and Mod 11/10. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum1 and checksum2 will be transmitted upon your selected checksum verification method. Max./Min.
Disable 00* Enable 01 00-64 00-64 Checksum Transmission 00* Max. code length 00-64 00-64 00* Min.
UK/plessey Read: Format Data Digits Checksum1+2 (Variable) (Optional) Checksum Verification: The UK/Plessey has one or two optional checksum digits. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA.
Disable 00* Enable 01 00-64 00-64 Checksum Transmission 00* Max. code length 00-64 00-64 00* Min.
Telepen Read: IATA (International Air Transport Association). Checksum Verification: The checksum is presented as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA.
00-64 00-64 00* Max. code length 00-64 00-64 00* Min.
Standard 2 of 5 Read: Format Data Digits Checksum1 (Variable) (Optional) Check-sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check-sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA.
*JAC* Disable 00* Enable 01 00-64 00-64 Check-sum transmission 00* Max. code length 00-64 00-64 00* Min.
China Post Read: Format Data Digits Checksum1 (Variable) (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. Program Option Bar Code Option Alphanumeric Entry Disable 00* Enable 01 00-64 00-64 Read 11* Max. code length 00-64 00-64 11* Min.
0-15 00-15 00* Truncate leading 0-15 00-15 00* Truncate ending 00-ffH ASCII 00-ffH code < t >* 00-44 01-44 Code ID setting 00* Insert group number selection Exit 95
Italian Pharmacode (Code 32) Read: Format Data Digits Checksum1 (Variable) (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. Leading “A”: If this function is enabled, each prefix of data shall be A.
00-64 00-64 09* Min.
Code-16K Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA.
00-44 00-ffH 00-44 00* Insert group number selection Exit 99
PDF-417 Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA.
Program Option Bar Code Option Alphanumeric Entry Disable 00 Enable 01* 0-15 00-15 Read 00* Truncate leading 0-15 00-15 00* Truncate ending 00-ffH ASCII 00-ffH code < P >* 00-44 00-44 Code ID setting 00* Insert group number selection *QAJ* Disable 00* Enable 01 Escape sequence transmit 101 Exit
EAN UCC Composite For the coupon extended code application. Coupon extended code is a supplementary barcode that is printed to the right of the UPC/EAN in UCC/EAN-128 symbology.
*YAK* Disable 00* Enable 01 UCC / EAN128 emulation Exit 103
RSS-14 Read: Format Data Digits Checksum1 (Variable) (Optional) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. UCC/EAN 128 emulation: Refer to Transmission, Code ID transmission must be set as AIM ID enable. Then ]C1 will be identified as prefix of barcode data transmission.
0-15 00-15 00* Truncate leading 0-15 00-15 00* Truncate ending 00-ffH ASCII 00-ffH code < R4 >* 00-44 00-44 Code ID setting 00* Insert group number selection Disable 00* Enable 01 UCC/EAN128 emulation Exit 105
RSS-Limited Read: Format Data Digits Checksum1 (Variable) (Optional) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. UCC/EAN 128 emulation: Refer to UCC/EAN 128 emulation of RSS-14.
00-ffH ASCII 00-ffH code < RL >* 00-44 00-44 Code ID setting 00* Insert group number selection Disable 00* Enable 01 UCC/EAN128 emulation Exit 107
RSS-Expanded Read: Format Data Digits Checksum1 (Variable) (Optional) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA. UCC/EAN 128 emulation: Refer to UCC/EAN 128 emulation of RSS-14.
0-15 00-15 00* Truncate ending 00-ffH ASCII 00-ffH code < RX >* 00-44 00-44 Code ID setting 00* Insert group number selection Disable 00* Enable 01 UCC/EAN128 emulation Exit 109
Micro-PDF Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51 Insertion group number selection of UPCA.
00-44 00-44 00* *XAI* Insert group number selection None 00 *XAJ* GLI protocol 01 Escape sequence ECI protocol 02* transmit Exit 111
String setting / Transmission (Prefix / Suffix) Prefix / Suffix characters setting: Characters defined as prefix or suffix characters will be transmitted immediately with the scanned data for all symbologies. Up to 22 ASCII characters can be defined as Prefix or Suffix. Format of barcode data transmission: Prefix Name Preamble ID Code Barcode Length Data ID Postamble Insert groups .
Program Option Bar Code Option Alphanumeric Entry None 00* 1-22 characters 00-ffH ASCII code Prefix characters setting None 0D* 1-22 characters 00-ffH ASCII Suffix characters code setting Exit 113
String setting / Transmission (Preamble/Postamble) Preamble/ Postamble characters: Preamble or Postamble characters will be appended to the data automatically for all symbologies. However, the transmission will not activate unless Preamble / Postamble transmission is enabled. Preamble transmission: By setting Enable, Preamble will be appended before the data transmitted. Postamble transmission: By setting Enable, Postamble will be appended after the data is transmitted.
Program Option Bar Code Option Alphanumeric Entry 1-22 characters “PREAMBLE”* 00-ffH ASCII code Preamble characters setting Disable 00* Enable 01 1-22 characters “POSTAMBLE”* Preamble transmission 00-ffH ASCII Postamble code characters setting Disable 00* Enable 01 Postamble transmission Exit 115
String setting / Transmission (Insert Group Characters) Insert G1/G2/G3/G4 character setting: The imager supports inserting two groups with each group 22 characters into transmitted data of selected symbologies. The two groups can be inserted into scanned data of the selected symbologies or positioned at leading / ending of data. There are total four groups for utilization. Insert data group position: To define the position of a group to insert into bar code data.
5) Repeat the same procedure in Insert G2 characters setting. 6) Scan Exit barcode. 1) Insert data group 1-4 position. Please refer to the specific barcode that you want to use. 2) Insert data group 1-4 position: The imager offers 4 positions to insert among the symbol. The position default value is “00” to indicate no character insertion. Beside, make sure insertion positions are not greater than the symbols; otherwise the insertion data is not effective.
1-22 characters “GROUP4”* 00-ffH ASCII code Insert G4 characters setting 00-64 00-64 (00: no insertion) 00* 00-64 00-64 (00: no insertion) 00* 00-64 00-64 (00: no insertion) 00* 00-64 00-64 (00: no insertion) 00* Insert data group 1 position Insert data group 2 position Insert data group 3 position Insert data group 4 position Exit 118
String setting / Transmission (Others) Code ID position: Upon your usage, the transmitting position of Code ID can be selected to place Before Code Data or After Code Data when it is transmitted. Code ID transmission: If your application is needed to transmit Code ID, you must set this to Proprietary ID or AIM ID. Code length transmission: A number of data digits can be transmitted before the code data when Enable is selected.
Before code data 00* After code data 01 Disable 00* Proprietary ID 01 AIM ID 02 Disable 00* Enable 01 Disable 00* Enable 01 Disable 00* Upper case 01 Lower case 02 Code ID position Code ID transmission Code length transmission Code name transmission Case conversion (For barcode data only) Exit 120
Test Chart (Bar code samples marked with symbol “*” are enabled initially.
PDF-417 * STANDRAD-25 PARA CODE-16K 87549 EAN-8 PARA * INDUSTRIAL-25 PARA UPCE PARA * 122
INTERLEAVED-25 PARA * MATRIX 25 PARA MSI/PLESSEY PARA UPCA PARA * UK/PLESSEY PARA RSS Micro-PDF * 123
ASCII Code Table Note: L 0 H 0 For keyboard wedge only.
Parameter Setting List Program * C B ! * Barcode standard parameter setting list If you wish to display the current barcode reading configuration of your AS-8000CL imager over the host terminal/computer, scan the Barcode standard parameter setting list bar code. System parameter setting list If you wish to display the current system configuration of your AS-8510 imager over the host terminal/computer, scan the System parameter setting list bar code.
Query present cradle firmware version Program Firmware version list If you wish to display the cradle and imager firmware versions, scan the “Firmware version list” barcode. Exit Reset cradle to factory default settings *$%-+IC%%* WARNING: Default value initialization If you wish to return the AS-8000CL imager to all the factory default settings, scan the above barcode will perform the feature. However, the cradle will be set to factory default settings at the same time.
0 A 1 B 2 C 3 D 4 E 5 F 6 7 8 Finish 9 127
NOTICE: This device complies with Part 15 of the FCC Rules. Operation shall be subject to the following two conditions: (1) This device may not cause harmful interface, and (2) This device must accept any interface received, including interface that may cause undesirable operation. This equipment has been tested and complied with the limits for a Class a digital device, pursuant to Part 15 of the FCC Rules.
Using the ArgoxScan 8000CL The ArgoxScan can automatically scan barcode at a distance. Simply aim and pull the trigger. Code scanning is performed along the center of the light bar emitted from the reading window. This bar must cover the entire code (see “How to Scan” in page 2). Successful scanning shall be obtained by tilting the scanner with respect to the barcode to avoid direct reflections that impair the reading performance.
警告使用者: 這是甲類的資訊產品,在居住的環境中使用時,可能會造成射頻 干擾,在這種情況下,使用者會被要求採取某些適當的對策。 低功率電波幅性電機管理辦法 第十二條 經型式認證合格之低功率射頻電機,非經許可,公司、商號或使 用者均不得擅自變更頻率、加大功率或變更原設計之特性及功能。 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發 現有干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。 前項合法通信,指依電信規定作業之無線電信。低功率射頻電機須忍受合法通 信或工業、科學及醫療用電波輻射性電機設備之干擾。
警告: 電池若未妥善處理, 可能會導致爆炸。 請勿拆卸電池, 或用火銷毀電池。 請將電池放置於兒童拿不 到的地方。 請使用專用充電器充電, 並請依照當地政府或法 律規定妥善處理廢棄電池。 CAUTION: EXPLOSION HAZARD Do not disassemble, short circuit, heat the battery or dispose of in fire. Store battery pack in a proper place. Do not expose to temperature above 60℃/140℉. Use specified charger only. Please dispose of the used batteries following the rules or laws issued by the local government.
CONTENTS Chapter 1 Introduction Installation…………………………………………… 1 How To Scan………………………………………… 2 Troubleshooting……………………………………… 3 Wireless Connection………………………………… 6 Battery Charging…………………………………… 8 Wireless Features…………………………………… 11 Auto Update……………………………………… 12 Deep Sleep Mode……………………………… 14 Handcuff Mode (Leash Alarm)………………… 15 Wireless Connectivity…………………………… 16 Inquiry Beep control…………………………… 18 Cradle Beep Loudness Control………………… 20 Additional Features……………………………… 22 Default Sett
EAN-8 ………………………………………………… 60 Code 39 ……………………………………………… 64 Interleaved 2 of 5 …………………………………… 68 Industrial 2 of 5 ……………………………………… 70 Matrix 2 of 5 Eur …………………………………… 72 Codabar ……………………………………………… 74 Code-128 …………………………………………… 77 Code-93 ……………………………………………… 81 Code-11.……………………………………………… 84 MSI/Plessey.………………………………………… 86 UK/Plessey.………………………………………… 88 Telepen.……………………………………………… 90 Standard 2 of 5 ……………………………………… 92 China Post …………………………………………… 94 Italian pharmacode (Code 32)..