The incoming ground & DC- cable is attached to the bottom of the ground block along with
ground leads to the negative bus on the fuse block and the enclosure’s ground lug.
The incoming DC+ cable is attached to the bottom of the DC+ bus on the fuse block. Cables to
the individual Hub antennas (light gray) terminate on the right side of the fuse block. The
electrolytic capacitor (2200 uF) across the power supply busses reduces transients when
individual Hub power connectors are inserted or removed with power ON. It is normally not
needed, but if it is used, be sure to observe the polarity.
Space is provided at the top of the box for additional lightning protectors, which have not proven
to be necessary at our test site in San Jose, CA. Lightning protectors are installed on a ground
bus in the base station equipment room to protect the indoor equipment.
Upper power strip with barriers for sensing cable
Ground bus
Individual fuses
Electrolytic capacitor
Figure 5-8: Close-up of OJB.
OJB Components
The OJB pictured here is assembled from the following components:
Device Vendor & Part Number Source
Enclosure Hoffman A-1412CH Electric Supply Trade www.hoffmanonline.com
Inner Panel Hoffman A14P12 Electric Supply Trade
June 2003 Page 5-7