Aquila Solutions Inc. MG401 Module Product Specification MG401 Module October 31, 2018 AQUILA is a trademark of Aquila Solutions, registered in the United States and other countries. Other product and brand names may be trademarks or registered trademarks of their respective owners. This technical data may be subject to U.S. and international export, re-export, or transfer (“export”) laws. Diversion contrary to U.S. and international law is strictly prohibited. Aquila Solutions Inc No.
1 Product Overview The MG401 module is an industrial-grade LTE module, which provides multiple bands support and covers most of LTE bands in North America. This module can be adapted to various types of terminal devices, providing LTE network connection and data communication, such as industrial routers, industrial handsets, tablet computers, laptops, etc. The MG401 module achieves download rates up to 150Mbps and uplink rates to 50Mbps (FDD). The MG401 module passed FCC, GCF, PTCRB, IC certifications.
2 General Features Parameter Main Chipset Value GCT GDM7243ST Dual ARM1136JFS processer 400MHz Memory 1Gb Nand Flash + 1Gb LPDDR2 Band support Band 8/12/17/13/14/25/2/26/5/41/66/4/42/43/48 Antenna 3 UFL ports LTE: Main and auxiliary antenna GNSS antenna Tx / Rx 1Tx / 2Rx MIMO DL: 4x2 MIMO or 2x2 MIMO UL: 1x2 MU-MIMO Modulation Uplink: QPSK / 16QAM / 64QAM Downlink: QPSK / 16QAM / 64QAM Power output +23dBm(Power Class 3) Throughput FDD DL: 150Mbps UL: 50Mbps Interface USB2.
3 Pin Definitions Pin Description Pin Description LTE_WAKE# GPIO1 GPIO2 USIM2_RESET GND VREF_1V8 USIM2_PWR GND Pin No. 1 3 5 7 9 11 13 15 VCC_Main GND NC USIM1_PWR USIM1_DATA USIM1_CLK USIM1_RESET NC Pin No.
Pin Pin Name Description No. I/O Voltage Domain Power VCC_Main VREF_1V8 2, 24,39, VCC source PI 3.3V 11 1.8V output PO 1.8V 4, 9, 15, Return current path 41, 52 18, 21, 26, 27, GND 29, 34, 35, 37, 40, 43, 50 Universal Serial Bus ( USB) USB_D+ USB_D- 38 36 USB serial data interface compliant I/O to the USB 2.0 specification I/O Auxiliary Signals PERST# 22 Functional reset to the card 1 Open Drain active Low signal. I 1.
specification ( VCC ) UIM reset signal. USIM1_RESET 14 Compliant to the ISO/IEC 7816-3 1.8V/3V O specification ( RST). UIM clock signal. USIM1_CLK 12 Compliant to the ISO/IEC 7816-3 1.8V/3V O specification ( CLK). UIM data signal. USIM1_DATA 10 Compliant to the ISO/IEC 7816-3 1.8V/3V I/O specification ( I/O). 13 USIM2_PWR Power source for the UIM. Compliant to the ISO/IEC 7816-3 1.8V/3V O specification ( VCC ) UIM reset signal. USIM2_RESET 7 Compliant to the ISO/IEC 7816-3 1.
4 DC Electrical MG401 recommends the application condition as following table. Parameter Description High-level input VIH Minimum Maximum Value Value Unit 1.17 VDD_IO V -0.3 0.63 V 1.6 VDD_IO V voltage Low-level input VIL voltage high-level output VOH voltage low-level output VOL 0 0.4 V voltage Pin Name Pin No.
7 Agency Certifications MG401 has been tested and certified with PTCRB/GCF/FCC/IC. Test Specification LTE FDD/TDD 3GPP TS 34.121 (RF/RRM-R8/R9) 3GPP TS 36.521-1 RF-R8 3GPP TS 36.521-1 RF-R9 3GPP TS 36.521-3 RRM-R8 3GPP TS 36.521-3 RRM-R9 3GPP TS 36.523-1 Protocol-R8 3GPP TS 36.523-1 Protocol-R9 3GPP TS 36.523-1 Protocol-(i-RAT) ETSI EN 102 230 (UICC) 3GPP TS 31.121 USIM (R8) 3GPP TS 31.124 USAT (R8) 3GPP TS 26.132 (Acoustic) - Rel-12 3GPP TS 36.124 (LTE RSE eFDD) - PTCRB 3GPP TS 34.229-1 (IMS) 3GPP TS 37.
Aquila Confidential
9 Module Dimensions Important Notice to OEM integrators 1. This module is limited to OEM installation ONLY. 2. This module is limited to installation in mobile or fixed applications, according to Part 2.1091(b). 3. The separate approval is required for all other operating configurations, including portable configurations with respect to Part 2.1093 and different antenna configurations 4. For FCC Part 15.
requirements if needed. End Product Labeling When the module is installed in the host device, the FCC label must be visible through a window on the final device or it must be visible when an access panel, door or cover is easily re-moved. If not, a second label must be placed on the outside of the final device that contains the following text: “Contains FCC ID: 2ASRY-MG401” The FCC ID can be used only when all FCC compliance requirements are met.
to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help.