OWNER’S MANUAL & INSTALLATION GUIDE Builders’ Choice Air INSTALLER: This booklet must be given to the product owner. Read all instructions before proceeding. All specifications are ± 3⁄8’’ and are subject to change without notice. Dimensions listed in inches.
TABLE OF CONTENTS PRODUCT WARRANTY REGISTRATION INFORMATION INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS PRE-INSTALLATION REQUIREMENTS Inspection Before Installation Pre-planning Access, Plumbing and Electrical Installation Before You Start INSTALLATION INSTRUCTIONS Structural Preparation Framing Diagrams Deck Cutouts Framing & Installation Procedures Integrally Skirted Air Baths Electrical Conections Final System Test & Clean-Up 3 4-5 6 7 7 8 8 9 10 11 12-13 14 OPERATIO
Builders’ Choice Air Owner's Manual & Installation Guide AQUATIC Product Warranty Registration Information Thank you for choosing an Aquatic bath. You have chosen one of the finest bath products in the industry. Aquatic supports your purchase with strong commitments to quality and customer satisfaction. IMPORTANT! To activate Product Warranty, please register with Aquatic. Your product warranty must be registered and confirmed with Aquatic through the Serial Number on your unit.
Builders’ Choice Air Owner's Manual & Installation Guide INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS WARNING: When using this unit, basic precautions should always be followed. Failure to follow these instructions could result in personal injury, electric shock, or fire. READ AND FOLLOW ALL INSTRUCTIONS: • WARNING: Risk of lethal electric shock.
Builders’ Choice Air Owner's Manual & Installation Guide INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS Before taking your first air bath, be sure you have performed the “system test.” [See FINAL SYSTEM TEST & CLEAN UP on page 14.] Be sure that you are familiar with all the controls and switches and that the unit is operating properly. [See TO OPERATE YOUR AIR BATH on page 15.] 1. The water in a bath tub should never exceed 40º C (104° F).
Builders’ Choice Air Owner's Manual & Installation Guide PRE-INSTALLATION REQUIREMENTS READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION TOOLS REQUIRED FOR INSTALLATION: (NOT INCLUDED) Drill 3/16" Drill Bit Tape Measure Pencil Phillips Screw Bit #10 x 1 ½" self –tapping washer head screw OR 1 ½" Galvanized roofing nail Safety Glasses Hammer Level INSPECTION BEFORE INSTALLATION 1.
Builders’ Choice Air Owner's Manual & Installation Guide PRE-PLANNING ACCESS, PLUMBING & ELECTRICAL INSTALLATION 1. Building materials and wiring should be routed away from the pump body or other heat-producing components. 2. Ensure that the floor is leveled and can support a load of 50 lbs. per square foot. (If floor is not leveled, shims may be needed to level the bath.) 3. Plan installation to permit access for servicing.
Builders’ Choice Air Owner's Manual & Installation Guide INSTALLATION INSTRUCTIONS FRAMING DIAGRAMS 1. Protect interior of tub throughout installation process. ELECTRICAL 2. Framing andINSTALLATION: supports will vary according to the model and type of installation selected. 3. Please refer back to the unit's Technical Data sheet for specific dimensions located at www.aquaticbath.com.
Builders’ Choice Air Owner's Manual & Installation Guide INSTALLATION INSTRUCTIONS DECK CUTOUTS A paper template will be enclosed with all rounded-edged models. Use the directions on the paper template for cutout dimensions. If the paper template has been lost or needs replacement, please contact Customer Service at: 800.945.2726. USING THE CUTOUT TEMPLATE Draw a center line horizontally and vertically on a 1” thick plywood deck.
Builders’ Choice Air Owner's Manual & Installation Guide INSTALLATION INSTRUCTIONS FRAMING & INSTALLATION PROCEDURES WARNING - When using electrical products, basic precautions should always be followed, including the following: DANGER - RISK OF ELECTRIC SHOCK. Connect only to a circuit protected by a Ground-Fault Circuit-Interrupter (GFCI). (For built-in and custom units.) Install to permit access for servicing. 1. Install outlet(s) per electrical requirements.
Builders’ Choice Air Owner's Manual & Installation Guide INSTALLATION INSTRUCTIONS INTEGRALLY SKIRTED AIR BATHS Remove the shipping blocks of wood that are nailed along the back of the “H” frame. 1. To avoid obstructions during installation, make sure water lines, spout pipes and valve plumbing do not project into alcove. 2. Ledger Strip: Fasten a 1” x 3” ledger strip along rear for alcove and along both sides in corner installations at Dimension LH. (see diagram 1A) 3.
Builders’ Choice Air Owner's Manual & Installation Guide INSTALLATION INSTRUCTIONS ELECTRICAL CONNECTIONS READ AND FOLLOW ALL INSTRUCTIONS All local, state and national electrical codes must be observed by a licensed electrician in connecting power to the Aquatic air bath. IMPORTANT SAFETY INSTRUCTIONS WARNING - When using electrical products, basic precautions should always be observed, including the following: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2.
Builders’ Choice Air Owner's Manual & Installation Guide INSTALLATION INSTRUCTIONS ELECTRICAL CONNECTIONS Builders’ Choice Air Series Component Breakdown Electrical Requirements:120VAC, 60Hz, 15 Amp GFCI protected outlet Pneumatic Air Button TEST RESET Dedicated 15 Amp GFCI Outlet Blower Aquatic 13
Builders’ Choice Air Owner's Manual & Installation Guide INSTALLATION INSTRUCTIONS FINAL SYSTEM TEST & CLEAN-UP System Test: To test system, follow these steps in order listed: 1. Fill clean tub with water to minimum 4” above air channels. 2. To test the Ground-Fault Circuit-Interrupter (GFCI), push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored.
Builders’ Choice Air Owner's Manual & Installation Guide OPERATION INSTRUCTIONS BEFORE USE • Make sure the bathtub is clean: If there are any residue or foreign materials left from construction, clean the bathtub thoroughly. Use only the methods and materials described in TUB CARE on page 16. • Test the Ground-Fault Circuit-Interrupter (GFCI): Test the GFCI as described in SYSTEM TEST on page 14.] This device should be tested on a routine basis. TO OPERATE YOUR AIR BATH 1.
Builders’ Choice Air Owner's Manual & Installation Guide TUB CARE MAINTENANCE IMPORTANT: Use only the recommended cleaners and procedures described in this section. Use of other materials and methods may harm your air tub and will VOID THE WARRANTY. Acceptable Cleaning Procedures for Acrylic Surfaces The surface of your whirlpool bathtub will retain its color and gloss indefinitely with normal use, but many bathroom cleaning agents can harm it.
Builders’ Choice Air Owner's Manual & Installation Guide TUB CARE REPAIR The installation and service of your air bath should be performed only by a qualified service technician. Remember when contacting your distributor always have your serial number, proof of purchase and model number available. This will ensure a quick response on warranty items. The model and serial numbers are located above the blower on the backside of the air bath.
Builders’ Choice Air Owner's Manual & Installation Guide WATER QUALITY CHEMICAL & WATER QUALITY Owners of fill and drain air bathtubs need to know basic information concerning water quality, how it affects the performance and enjoyment of the operation of their tubs, and steps that can be taken by the owner to correct related problems. Important issues are the microbiological and chemical quality of the water. 1.
Builders’ Choice Air Owner's Manual & Installation Guide WATER QUALITY Iron - Iron is found in many natural waters especially from wells. Iron in water can also result from the corrosion of piping in the water supply system, such as cast iron mains or galvanized steel service lines, or galvanized piping in the home water system. High iron levels may result in the formation of brown stains in the vicinity of the faucet outlets of various fixtures in the home.
Builders’ Choice Air Owner's Manual & Installation Guide AIR BATH USER INFORMATION PLEASE NOTE: The air bath action may cause even small amounts of bubble bath or shampoo to foam excessively. Exercise moderation in experimenting with different soap products. No servicing of this product should be done by the user. There are no user serviceable parts. All controls are located in the control recesses on the lip of the tub. These are the only controls that should be used by the consumer.
Builders’ Choice Air Owner's Manual & Installation Guide TROUBLESHOOTING GUIDE WARNING: Always turn off power at the main electrical service panel when servicing your air bath. SYMPTOMS POSSIBLE PROBLEMS SUGGESTED SOLUTIONS Air bath system does not operate: 1) No power to air bath unit. 1) Reset circuit breakers and GFCI if tripped. Check fuses and replace if bad. 2) Reset GFCI. 3) Visually inspect air tube for kinks or slits. 4) Check air tube connections at blower and at bottom. 5) Contact Aquatic.
Builders’ Choice Air Owner's Manual & Installation Guide REPLACEMENT PARTS MAP REPLACEMENT PARTS LIST ILLUSTRATION # PART # DESCRIPTION 1a. 8115BUTTNxx* Button; Air On/Off 1b. 8115BODY Body; Air Button 1c. 8110TUBE Tubing; 1/8” Air 2a. 8001BLW Blower;300W Heater w/AS Timer 2b. 8409015FTG 1.5” 90° Elbow; ST 2c. 8427FTG 1.5” Union Check Valve 2d. 8406010FTG 1” 90° Elbow; SLIP 2e. 8409010FTG 1” 90° Elbow; ST 2f. 8437211FTG 1.
Aquatic Limited Warranty Builders’ Choice Series Limited Warranty For Original Consumer For Household Usage WHAT PRODUCTS ARE COVERED Structures and surface finishes on Whirlpools (“Whirlpools”), Air Baths (“air baths”) and Soaking Tubs (Tubs”), and their support systems including equipment, components, attachments and plumbing equipment. Different warranty periods apply to specific components.
Customer Service: 800.945.2726 • aquaticbath.com 8MANBCA | Rev. 07.