MPR-1914 -1- 1/2/2015 SENTINEL-SENSE MPR-1914 Installation & Operation Manual-041480
MPR-1914 -2- 1/2/2015 COPYRIGHT ACKNOWLEDGEMENTS The contents of this document are the property of Applied Wireless Identifications Group, Inc. (AWID) and are copyrighted. All rights reserved. Any reproduction, in whole or in part, is strictly prohibited. For additional copies of this document please contact: AWID 18300 Sutter Blvd Morgan Hill, CA 95037 http://www.AWID.
MPR-1914 -3- 1/2/2015 Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
MPR-1914 -4- 1/2/2015 I NDUSTRY C ANADA COMPLIANCE This device complies with RSS-210 of the Industry Canada Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Ce dispositif est conforme à la norme CNR-210 d'Industrie Canada applicable aux appareils radio exempts de licence.
MPR-1914 -5- 1/2/2015 NOTE IMPORTANTE: Dans le cas où ces conditions ne peuvent être satisfaites (par exemple pour certaines configurations d'ordinateur portable ou de certaines co-localisation avec un autre émetteur), l'autorisation du Canada n'est plus considéré comme valide et l'ID IC ne peut pas être utilisé sur le produit final. Dans ces circonstances, l'intégrateur OEM sera chargé de réévaluer le produit final (y compris l'émetteur) et l'obtention d'une autorisation distincte au Canada.
MPR-1914 -6- 1/2/2015 Professional Installation Instructions 1. Installation personnel This product is designed for specific application and needs to be installed by a qualified personnel with knowledge in RF and related regulations. The general user shall not attempt to install or change the setting. 2. Installation location The product shall be installed at a location where the radiating antenna be kept 20cm from nearby person in normal operational condition to meet regulatory RF exposure requirement.
MPR-1914 -7- 1/2/2015 5. Avertissement Choisir avec soin la position d'installation et s'assurer que la puissance de sortie ne depasse pas les limites en vigueur. La violation de cette regle peut conduire a de serieuses penalites federales.
MPR-1914 -8- 1/2/2015 Table of Contents REVISION HISTORY .......................................................................................................9 1 INTRODUCTION.....................................................................................................10 1.1 2 SPECIFICATIONS ..................................................................................................11 2.1 2.2 2.3 3 Channel Frequency Table.................................................................
MPR-1914 -9- 1/2/2015 REVISION HISTORY Version No. 1.0 1.1 Revised By Date AWID Engineering AWID Engineering 10/2014 11/2014 Sections Affected - 1.2 AWID Engineering 12/2014 - 1.
MPR-1914 1 - 10 - 1/2/2015 INTRODUCTION AWID's Sentinel-Sense MPR-1914 is a long-range (up to 20 feet) Radio Frequency IDentification (RFID) reader module with 3.3 V TTL logical interface that works with most leading passive UHF passive tags. The reader module comes with a unique combination of long read range, small size, and low power consumption. Its primary applications are asset management and tracking, and fleet management applications. MPR-1914 is delivered with Firmware Version such as 21.xx.xx.
MPR-1914 - 11 - 2 SPECIFICATIONS Input voltage Input current Idle Power Protocol language Read range RF connectors Output power Transmit frequency Receiver frequency Hopping channels Channel spacing Hopping sequence Operating temperature range Output data formats I/O Connector Dimension 1/2/2015 +13 VDC ±1.0V 2.0 A max 1.3W in stand-by ISO Type B/C, EPC Class 1 Gen 2 Depends on type & size of labels used 4xMMCS (F) USWR<1.2 @50OHMs +30 dBm max 902.60-927.40 MHz 902.60-927.
MPR-1914 2.2 - 12 - 1/2/2015 CONNECTOR PIN ASSIGNMENT Pin Function Pin Function 1 2 3 4 5 Reserved Reserved Reserved +13 V ± 1.0V +13 V ± 1.0V 6 7 8 9 10 GND Unit Enable (*) SCIR SCIT GND (*) Note: pin 7 is internally pulled high. User may leave this pin unconnected if manual control is not required 2.3 MEASURING READ DISTANCE Make sure you know the tag types.
MPR-1914 3 - 13 - 1/2/2015 INSTALLATION & OPERATION GUIDELINES For ease of explanation, MPR reader in this section refers to an RFID device that consists of MPR-1914 and a high performance circular polarized antenna inside a splash proof, UV stabilized housing case. The module should be installed on a heat sink. Example of a heat sink could be an aluminum plate of size 8”x8”x0.1” exposed to convection air flow. The screws at the bottom of module shall be used for mounting the module on the heat sink. 3.
MPR-1914 4 - 14 - 1/2/2015 INSTALLATION PROCEDURE This section provides installation and operation information for MPR-1914 reader modules. 4.1 PARTS LIST Verify that all items listed below are present before starting the installation. o Sentinel-Sense MPR-1914 o Documentation 4.2 Qty=1 Qty=1 PREPARATION FOR INSTALLATION Familiarize yourself with the connectors and pin out assignment of each I/O connectors. 4.2.
MPR-1914 5 5.1 - 15 - 1/2/2015 SOFTWARE PROGRAMMING AND SYSTEM OPERATION NOTES SYSTEM OPERATION 5.1.1 Running a Custom Software Application or the AWID Demo Program If AWID Demo Program is not used, it is expected user will launch a Custom Software Application developed using the MPR Communication Protocol and/or the supporting SDK (http://www.awid.com Support/Download) to issue commands to the MPR reader/module as specified. 5.1.
MPR-1914 6 - 16 Reference MPR Communication Protocol Manual – Doc# 041479 MPR Command Demo II Quick Reference Guide – Doc# 041483 1/2/2015