by Schneider E 1e c tric Back-UPS®Pro 1300/1500 Installation and Operation Inventory Safety Do not install the Back-UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids. Connect the battery 0 Install PowerChute® Personal Edition Software APC PowerChute Personal Edition software provides automatic file saving and shutdown of your computer in the event of a power failure.
Connect the equipment Battery Backup and Surge Protected outlets When the Back-UPS is receiving input power, the Battery Backup with Surge Protection outlets will supply power to connected equipment. During a power outage or other utility problems, the Battery Backup outlets receive power for a limited time from the Back-UPS. Connect equipment such as printers, fax machines, scanners, or other peripherals that do not need battery backup power to the Surge Protection Only outlets.
Operation Power-Saving Function ~ w To conserve electricity, configure the Back-UPS to recognize a Master device, such as a desktop computer or an AN receiver, and Controlled peripheral devices, such as a printer, speakers, or a scanner. When the Master device goes into Sleep or Standby mode, or is switched OFF, the Controlled device(s) will be switched off as well, saving electricity. Enable the Power-Saving function. Press and hold MUTE and DISPLAy simultaneously for two seconds.
Front Panel Buttons and Display Interface Use the three buttons on the front panel of the Back-UPS and the display interface to configure the Back-UPS. Front panel 0 0 0 0 Mute button Power On/Off button Display button Display interface ··~·····~ ONilATT .-( LOW .&~uAL EVENT~ ES1lMI\1ED RUN 'liME IN MIMITES :l~8.8.
Warnings and System Faults Audible Warnings Four Beeps Every 30 Seconds Continuous Beeping Back-UPS is running on battery. You should consider saving any work in progress. Low battery condition and battery run-time is very low. Promptly save any work in progress, exit all open applications, and shut down the operating system. Continuous tone Battery Backup outputs are overloaded. Chirps for 1 Minute every 5 hours Battery fails the automatic diagnostic test and should be replaced.
Function Button Quick-Reference Function Timing Button (seconds) UPS Status Description Power Power On Power Off <9 <9 0.2 Off Press POWER to start receiving input utility power. If A/C input power is not available, the Back-UPS will run on battery power. 2 On The Back-UPS is not receiving input utility power, but is providing surge protection. ~ 0.2 On Verify the status or condition of the Back-UPS. The LCD will illuminate for 60 seconds.
Troubleshooting Problem Back-UPS will not switch on. The Back-UPS is not connected to utility power. The circuit breaker has been tripped. The internal battery is not connected. The utility input voltage is out of range. The Back-UPS does not Ensure that essential equipment is not provide power during a utility plugged into a SURGE ONLY outlet. \\ClWer outage.
Specifications Replacement Battery VA 1300 VA I 1500 VA Maximum Load 780W I 865 W Nominal Input Voltage 120V Online Input Voltage Range 88- 139V The battery cartridge typically lasts 3 to 6 years, a shorter period if subjected to frequent outages or elevated temperatures. For the BR1300G or BR1500G, order part APCRBC124. Please recycle spent battery cartridges. (94-1 07) +11.5% Service (126-141) -11/5% If the Back-UPS arrived damaged, notify the carrier.