Antaira Industrial Ethernet Switches LMP-0601G-SFP Series User Manual V1.0 LMX-0601G-SFP Series 6-Port Industrial Gigabit Managed Ethernet Switch, with 5*10/100/1000Tx and 1*100/1000 SFP Slot; 12~48VDC Power Input User Manual Version 1.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 © Copyright 2018 Antaira Technologies, LLC All Rights Reserved This document contains information, which is protected by copyright. Reproduction, adaptation or translation without prior permission is prohibited, except as allowed under the copyright laws. Trademark Information Antaira is a registered trademark of Antaira Technologies, LLC, Microsoft Windows and the Windows logo are the trademarks of Microsoft Corp.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 FCC Warning This equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 Table of Contents 1. Introduction ................................................................. 1 1.1 Product Overview ............................................... 1 1.2 Product Software Features ................................ 1 1.3 Product Hardware Features ............................... 2 1.4 Package Contents .............................................. 2 1.5 Safety Precaution..........................................
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.2 Basic Setting .................................................... 16 5.2.1 System Information ..................................... 16 5.2.2 Admin &Password ....................................... 17 5.2.3 IP Setting..................................................... 18 5.2.4 System Time ............................................... 19 5.3Port Management ............................................. 20 5.3.1 Port Status ...
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.7.2 802.1Q VLAN Settings ................................ 39 5.8. IGMP Snooping ............................................... 39 5.8.1 IGMP Settings ............................................. 40 5.8.2 IGMP Snooping Status Table ...................... 41 5.9 QoS (Traffic Prioritization) ................................ 41 5.9.1 QoS Classification ....................................... 42 5.9.2 CoS Mapping ....................
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.13.1 MAC Address Table .................................. 52 5.13.2 MAC Table Configuration ......................... 52 5.14 Maintenance .................................................. 53 5.14.1 Upgrade .................................................... 53 5.14.2 Reboot....................................................... 54 5.14.3 Default ....................................................... 54 5.15 Configuration ......
Antaira Industrial Ethernet Switches LMP-0601G-SFP Series User Manual V1.0 1. Introduction Antaira Technologies’ industrial managed switches come with a pre-installed “user friendly” web console interface, which allows users to easily configure and manage the units, whether one is using a serial console and command line interface(CLI) commands like Telnet, SSH, HTTP (Web GUI) or simple network management protocols (SNMP). 1.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 Configuration Backup – USB Port 1.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 2. Hardware Description 2.1 Physical Dimensions Figure 2.1, below, shows the physical dimensions of Antaira’s LMX-0601G-SFP series: 6-port industrial managed Ethernet switch with 5*10/100/1000Tx, and 1*100/1000 SFP slot; 12~48VDC power input. (W x D x H) is 46mm x 99mm x 142mm Figure2.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 2.2 Front Panel The front panel of the LMX-0601G-SFP series industrial managed Ethernet switches is shown below in Figure 2.2. Figure 2.2 - The Front Panel of LMX-0601G-SFP Series 2.3 Top View Figure 2.3, below, shows the top panel of the LMX-0601G-SFP series switch that is equipped with one 6-pin removal terminal block connector for dual DC power inputs (12~48VDC). Figure2.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 2.4 LED Indicators There are LED light indicators located on the front panel of the industrial Ethernet switch that display the power status and network status. Each LED indicator has a different color and has its own specific meaning, see below in Table 2.1.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 2.5 Ethernet Ports RJ-45 Ports RJ-45 Ports (Auto MDI/MDIX): The RJ-45 ports are auto-sensing for 10Base-T, 100Base-TX, and 1000Base-T connections. Auto MDI/MDIX means that the switch can connect to another switch or workstation without changing the straight-through or crossover cabling. See the figures as below for straight-through and crossover cabling schematics. RJ-45 Pin Assignments (Table 2.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 The following figures show the cabling schematics for straight-through and crossover. Figure 2.4 Straight-through Cable Schematic Figure 2.5 Crossover Cable Schematic The following figures show the 10/100/1000 Ethernet RJ-45 pin outs. Figure 2.6: RJ45 Ethernet Port Pin Outs Figure 2.7: Straight through cables schematic Figure 2.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 2.6 Cabling Twisted-pair segments can be connected with an unshielded twisted pair (UTP) or shielded twisted pair (STP) cable. The cable must comply with the IEEE 802.3u 100Base TX standard (e.g. Category 5, 5e, or 6). The cable between the equipment and the link partner (switch, hub, workstation, etc.) must be less than 100 meters (328 ft.) long. Fiber segment – port 6: dual rate (100/1000) SFP slot.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 Second, insert the fiber cable of the LC connector into the transceiver as shown below in Figure2.11. Figure 2.11 - LC Connector to the Transceiver To remove the LC connector from the transceiver, please follow the steps shown below: Press the upper side of the LC connector from the transceiver and pull it out to release as shown below in Figure 2.12. Figure 2.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 2.7 Wiring the Power Inputs Please follow the steps below to insert the power wire. 1. Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-) contacts on the terminal block connector as shown below in Figure 2.6. Figure 2.6 - Power Terminal Block 2. Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in Figure 2.7. Figure 2.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 2.8 Wiring the Fault Alarm Contact The fault alarm contact is in the middle of the terminal block connector as the picture shows below in Figure 2.8. By inserting the wires, it will detect the fault status including power failure or port link failure (managed industrial switch only) and forma normally open circuit. An application example for the fault alarm contact is shown below in Figure 2.8. Figure 2.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 3. Mounting Installation 3.1 DIN-Rail Mounting The DIN-Rail is pre-installed on the industrial Ethernet switch from the factory. If the DIN-Rail is not on the industrial Ethernet switch, please see Figure 3.1 to learn how to install the DINRail on the switch. Figure 3.1 The Rear Side of the Switch and DIN-Rail Bracket Follow the steps below to learn how to hang the industrial Ethernet switch. 1.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 3.2 Wall Mounting Follow the steps below to mount the industrial Ethernet switch using the wall mounting bracket as shown below in Figure 3.4. 1. Remove the DIN-Rail bracket from the industrial Ethernet switch by loosening the screws. 2. Place the wall mounting brackets on the top and bottom of the industrial Ethernet switch. 3. Use the screws to screw the wall mounting bracket on the industrial Ethernet switch. 4.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 4. Hardware Installation 4.1 Installation Steps This section will explain how to install Antaira’s LMX-0601G-SFP0 series: 6-port industrial gigabit managed Ethernet switch with 5*10/100/1000Tx RJ45 ports, and 1*100/1000 SFP Slot; 12~48VDC power input. Installation Steps 1. Unpack the industrial Ethernet switch from the original packing box. 2. Check if the DIN-Rail bracket is screwed on the industrial Ethernet switch.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5. Web Management 5.1 Web Console Configuration This section introduces the configuration by web browser. 5.1.1 About Web-Based Management All of Antaira’s industrial managed switches are embedded with HTML web console interfaces that have a flash memory on the CPU board.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 3. The login screen appears. 4. Key in the default username: admin and password admin. 5. Click the “Login” button, then the main (status) page of the web console will appear (Figure 5.2). The online image of the switch will display the real-time ports connection status. Figure 5.2 - Web Console Main (Status) Page 5.2 Basic Setting 5.2.1 System Information Below, Figure 5.3, shows the switch system setting information. Figure 5.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 Terms Value Description Factory Default: Switch *Users can assign any name label to identify this managed node. By convention, a domain name is a text string drawn from System Name the alphabet (A-Z, a-z), digits (0-9), minus sign (-). No space characters are permitted as part of a name. The first character must be an alpha character. And the first or last character must not be a minus sign. The allowed string length is 0 to 255.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 Terms Value Description New Password Users can assign a new password, and the maximum string length allowed is 0 to 31 characters. Confirmation Re-type the new password. Click “Apply” to save changes. Figure 5.6 – Admin & Password Description 5.2.3 IP Setting Configure the managed switch’s IP setting information. Figure 5.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 Subnet Mask Assign the subnet mask of the IP address. If the DHCP client function is enabled, the user is not required to assign the subnet mask. Gateway Assign the network gateway for the switch. If the DHCP client function is enabled, the user is not required to assign the Gateway. DNS Assign the DNS IP address. Click the “Apply” button to save changes. Figure 5.8 – IP Setting Information Description 5.2.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.3Port Management 5.3.1 Port Status The following information provides the current port status. Figure 5.11 – Port Status Interface 5.3.2 Port Configuration Users can assign or insert a “value/label” for each port under each “Port Name” box; enable or disable each port function; state the speed/duplex of each port; and enable or disable the flow control of the port. Figure 5.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 Terms Value Description Port No. It shows each port status: Up for link active, and Down for link inactive. Port Name Users can create or insert a value or label for each port’s identification. Status Enable or disable a port Speed/Duplex Flow Control Users can set the bandwidth of each port as Auto-negotiation, 100 full,100 half,10 full,10 half mode.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.5 ERPS In any industrial automation application, designing the redundant ring network paths can protect networks from unexpected failovers is extremely important in mission-critical networks that need to provide uninterrupted services. In practice, several loop protection methods are implemented to ensure that network functions normally without loops and recovers as soon as possible when a point of failure occurs.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.5.1 ERPS Status Below, Figure 5.18, shows the network redundancy ring status with the Ethernet Ring Protection Switch (ERPS) protocol. Figure 5.14 – Redundant Ring Network – ERPS Status 5.5.2 ERPS Configuration Below, Figure 5.19, shows the ERPS configuration interface. Figure 5.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 Terms Value Description Protocol “Enable” or “Disable” ERPS protocol Ring Port 0 Ring Port 1 ERPS ring port 0, can be mapped to port 1 – port 6. Do not set the same as Ring port 1. ERPS ring port 0, can be mapped to port 1 – port 6. Do not set the same as Ring port 0. Set the ERPS role as Owner, Neighbor or Normal. [Owner] In charge of blocking one side of RPL link. It will prevent the packet flow from its blocked port.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.5.3 Before Configuring ERPS Before configuring ERPS, the rapid spanning tree protocol (RSTP), or multiple spanning tree protocol is required to disabled, because only one protocol can be exclusively running within a switch. Below are the steps to disable RSTP or MSTP. Step 1: Login to the switch with a web browser. Step 2: Open the “RSTP Configuration” page under the “Spanning Tree” manual as below Figure 5.17. Figure 5.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 Step 4: Press the “Apply” button in the lower right corner (Figure 5.19). Figure 5.23 – RSTP/CIST Configuration Interface Ethernet Ring Protection Switch (ERPS) is an Ethernet ring protection protocol which is used to prevent forming the loop in LAN, thus, the Broadcast Storm problem could be avoided. The loop avoidance mechanism ensures the traffic flows on all but the RPL ring link.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.5.3.1 Scenario A – RPL Configured Architecture Under scenario A, there are three major roles that are required to be configured within the ERPS configuration. Figure 5.20 – RPL-Configured Architecture Caution: Before enabling any ERPS protocols on any of the Ring Nodes, please DO NOT connect all switches to form a loop (ring) network just yet.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 [RPL Owner Node] There is only one RPL Owner Node that can be set in a ring network. In order to set up the RPL Owner Node, choose a switch and enable the “Protocol” under the ERPS Configuration interface, and follow the steps below (Figure 5.25). Step 1: Choose a specific port from the dropdown box next to “ring port 0”, and set it as “Owner” node by clicking the dropdown box next to “Role” below “ring port 0”.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 [RPL Neighbor Node] Users should choose a second managed switch that is adjacent to the first managed switch and set it up as the RPL neighbor node.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 [Normal Node] Then user should setup the rest of the managed switches’ “Role” of both “Ring Port 0 and 1” as “Normal Node” as shown above in Figure 5.23. Please be sure no duplicate port number has been chosen within a managed switch’s ERPS ring setting, the incorrect configurations may lead to unexpected errors. Figure 5.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.5.3.2 Scenario B – Non-Configured Architecture In some situations, users can choose not to configure the RPL owner and neighbor node; the ERPS could still work well under the mechanism by blocking one of the ring ports in the ERPS ring topology. Figure 5.24 – Non-Configured Architecture Caution: Before enabling any ERPS protocols on any of the Ring Nodes, please DO NOT connect all switches to form a loop (ring) network just yet.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 Figure 5.25 – Non-Configured Architecture Setup Example 5.6 Spanning Tree The Spanning Tree Protocol (STP), defined in the IEEE Standard 802.1d, can be created within a mesh network of connected layer-2 switches. The Rapid Spanning Tree Protocol (RSTP), defined in the IEEE 802.1w. RSTP is an enhanced solution of STP.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.6.1 RSTP Status Figure 5.26 shows the RSTP algorithm results. Figure 5.26 – RSTP Information Interface 5.6.2 RSTP Configuration Users can enable/disable the RSTP function, and set the parameters for each port. Figure 5.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 Terms Value Description Users can select the RSTP or MSTP function to be Mode enabled or disabled before configuring the related parameters. A value used to identify the root bridge. The bridge with the lowest value has the highest priority and is selected as Root Priority (0~61440) the root. If any change of the value, the switch is required to be reboot.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 the port as an edge port, set the port to “True”. The port includes the STP mathematic calculation. Admin Non STP True is not including STP mathematic calculation. False is including the STP mathematic calculation. Click the “Apply” button to save changes. Figure 5.28 – RSTP Configuration Terms & Value Description MSTP (Multiple Spanning Tree Protocol) It is defined in IEEE 802.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.6.4 MSTI Configuration Users can display the MSTI root status and port status by selecting the “Instance ID” number from 1 to 15 by clicking on the dropdown box from the “MSTI Status” interface. Figure 5.30 – MSTI Configuration Interface Terms Value Description MTSI Configuration Name Revision Users can insert the unique MAC address of the bridge switch. Users can insert a value from 0~65535. MTSI Instance Instance No.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 Click the “Apply” button to save changes. Figure 5.31 – MSTI Configuration –Terms & Value Description Figure 5.32 – MSTI Port Configuration Interface Terms Instance Tabs Value Description Users can select Instance Tab #1~#15 to configure each MSTI port “Cost” & “Priority” value. Users can define the path cost value from 1 through Cost 200000000 to the other bridge from this transmitting bridge at the specified port.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.7. 802.1Q VLAN A Virtual LAN (VLAN) is a logical network grouping that limits the broadcast domain, which allows users to isolate network traffic. Only the members of the VLAN will receive traffic from the same members of VLAN. Basically, creating a VLAN from a switch is logically equivalent of reconnecting a group of network devices to another Layer 2 switch.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.7.2 802.1Q VLAN Settings Figure 5.35 – 802.1Q VLAN Settings Interface Terms Value Description PVID Users can assign a Port VLAN ID for each port. Users can choose any port be “Tagged” or “Untagged”. Tagged VLAN: Set the tagged PVIDs to carry different Filter VLAN frames to other switch. Untagged VLAN: Set the port PVID for untagged devices that connect to the port. The range of PVID is 1 to 4094.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 decreases the workload at the end hosts since their network cards (or operating system) will not receive and filter all the multicast traffic generated in the network. IGMP has 3 versions, IGMP v1, v2, and v3, and support query group up to 256 groups. 5.8.1 IGMP Settings Figure 5.37 – IGMP Snooping Settings Interface Terms Value Description IGMP Protocol Check the box to enable or disable IGMP Snooping.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.8.2 IGMP Snooping Status Table Multicast filtering is the system by which the end stations only receive multicast traffic if they have registered to join specific multicast groups. With multicast filtering, network devices only forward multicast traffic to the ports that are connected to registered end stations. Figure 5.39 – IGMP Snooping Status Table 5.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.9.1 QoS Classification Figure 5.40 – QoS Classification Interface Terms Value Description Users can set it as “Weighted” or “Strict”. Weighted Mode: An 8, 4, 2, 1 weighting is applied to Queue Scheduling each round robin priority queue. Strict Mode: It gives egress queues with higher priority to be transmitted first before lower priority queues are serviced. ” Users can select the trust mode with either DSCP or Cos.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 clicking from dropdown box; of which 0 is the Highest, and 7 is the lowest. Click the “Apply” button to save changes. Figure 5.41 – QoS Classification Terms & Value Description 5.9.2 CoS Mapping Figure 5.42 – CoS Mapping Interface Terms Value Description Users can assign each port a CoS value from 0 to 7. Cos Value (0~7) According to the IEEE 802.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.9.3 ToS Mapping ToS is an acronym for Type of Service. It is implemented as the IPv4 ToS priority control. It is fully decoded to determine the priority from the 6-bit ToS field in the IP header. The most significant 6 bits of the ToS field are fully decoded into 64 possibilities, and the singular code that results is compared against the corresponding bit in the IPv4 ToS priority control bit (0~63). Figure 5.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.10 Port Mirroring Enable or disable the mirroring feature. When enabled, a copy of matched frames will be mirrored to the destination port specified in the port mirroring interface. Figure 5.46 – Port Mirroring Configuration Interface Terms Value Description Port Mirror Mode Enable Port Mirroring function by checking the box.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.11 SNMP Simple Network Management Protocol (SNMP) is the protocol developed to manage nodes (servers, workstations, routers, switches and hubs etc.) on an IP network. SNMP enables network administrators to manage network performance, find and solve network problems, and plan for network growth. Network management systems learn of problems by receiving traps or change notices from network devices implementing SNMP. 5.11.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.11.2 SNMP Trap Setting Figure 5.50 – SNMP Trap Setting Terms Value Description Enable SNMP Trap Enable the SNMP Trap function by checking the box. Trap Destination IP Community Users can insert the Server IP address as the Trap Destination IP info. Users can release the SNMP to the public for “read-only”. Click the “Apply” button to save changes. Figure 5.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.12 System Warning System warning function is very important for managing a switch. Users can manage the switch by “Syslog”, “System Event Log”, and “Email Server” setup for Advanced Notice in any event type, “Event Type Selection”, and “Fault Alarm” setting. By setting up all these system warning features, users will receive the in advanced warning message through email, whenever any event occurs.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 Click the “Apply” button to save changes. Figure 5.53 – SYSLOG Setting Terms & Value Description 5.12.2System Event Log Users can view and display the system event log by clicking the “Apply” button on the right bottom corner of the interface. Then, the system event logs will display within the SYSLOG LIST window. The SYSLOG LIST will contain up to 5 pages of system event log information.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.12.3 SMTP Setting The Simple Mail Transfer Protocol (SMTP) is for e-mail transmission across the Internet. Figure 5.55 – SMTP Setting Interface Terms Value Description E-mail Alert Enable/Disable transmission system warning events by e-mail. SMTP Server Address Setting up the mail server IP address. Sender E-mail Set up the email account to send the alert. Address Mail Subject The subject of the mail.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.12.4 Event Selection Users can select any event type through the “Event Selection” interface, such as “System Cold Start”, any ports’ “Link Up”, “Link Down”, “Link Up & Link Down” and send the system warning massage to either SYSLOG or SMTP, or both at the same time. After the event selection, users can click the “Apply” button to save changes. Figure 5.57 – Event Selection Setting Interface 5.12.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.13 MAC Table The MAC address table is the filtering database that supports queries by the forwarding process, as to whether a frame received by a given port with a given destination MAC address is to be forwarded through a given potential transmission port. 5.13.1 MAC Address Table Figure 5.59 – MAC Address Table Interface 5.13.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.14 Maintenance Under the maintenance section, users can execute updated firmware upgrades, system reboots, and reset the system to factory defaults. 5.14.1 Upgrade Antaira is continuously developing new functions and features for specific application requirements for the industrial managed switches. Users can download the latest firmware from Antaira’s website and store it within their local PC, server, or USB drive. Figure 5.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.14.2 Reboot Users can click the “Apply” button under the “Reboot” interface to reboot the switch. Figure 5.63 – Switch Reboot Interface 5.14.3 Default Users can reset the switch to “Factory Default” by clicking the “Apply” button under the default interface. Figure 5.64 – Reset Factory Default Interface 5.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.15.1 Save Users can click the “Save” button under the “SAVE CONFIGURATION” interface, once all the settings have been configured. Figure 5.65 – Save Setting Interface 5.15.2 Backup & Store Figure 5.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 then finish by clicking the “Upload” button. USB Management Fill in the folder and filename and click the “Backup” Save Running Config to USB button. If the folder or filename does not exist, the system will generate it automatically. Ex: file1, / folder /file2. Fill in the folder and filename and click the button of Backup.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 5.16 Logout Users can logout of the web console interface by pointing at and clicking ‘logout’ from the menu. 6. Command Line Interface Management 6.1 About CLI Management Besides WEB-based management, LMX-0601G-SFP series also supports CLI management. Users can use console or telnet to manage their switch by CLI.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 Step 2: Input a name for the new connection. Step 3: Select a certain COM port number.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 Step 4: The COM port property settings are as follows: 115200 for “Bits per second”, 8 for “Data bits”, None for Parity, 1 for “Stop bits” and none for “Flow control”. Step 5: The Console login screen will appear. Use the keyboard to enter the Username and Password, then press “Enter”.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 CLI Management by Telnet Users can use “TELNET” to configure the switches. The default value is below: IP Address: 192.168.1.254 Subnet Mask: 255.255.255.0 Default Gateway: none User Name: admin Password: admin Follow the steps below to access the console via Telnet. Step 1: Enter the Telnet IP address of the switch from the Windows “Run” command as below. Step 2: The Login screen will appear.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 2. CLI : enable -> configure terminal ->copy startup-config usb (path) Fill in the folder and filename behind the “copy startup-config usb” command. Ex: file1, / folder /file2. 3. CLI :enable -> configure terminal ->copy usb startup-config (path) Fill in the folder and filename behind the “copy usb startup-config” command. Ex: file1, / folder /file2.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 4. CLI : enable -> configure terminal ->copy usb firmware (path) Fill in the folder and filename behind the “copy usb startup-config” command. Ex: file1, / folder /file2. 5. CLI : enable -> configure terminal -> Syslog mode (usb or all) Select USB or ALL, it can auto save the waning file to the USB. And the file name is “message”. 6. CLI : enable -> configure terminal ->usb auto load enable 7.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 7. Technical Specifications Table 7.1 has the technical specifications for Antaira’s LMX-0601G-SFP series: 6-port industrial gigabit managed Ethernet switch with 5*10/100/1000Tx, 1*100/1000 SFP Slot; 12~48VDC power input. Standards IEEE 802.3 10Base-T 10Mbit/s Ethernet IEEE 802.3u 100Base-Tx, 100Base-Fx, Fast Ethernet IEEE 802.3ab 1000Base-T Gigabit Ethernet IEEE 802.3z 1000Base-X Gigabit Fiber IEEE 802.
Antaira Industrial Ethernet Switches LMX-0601G-SFP Series User Manual V1.1 (100m); 100BaseTX: 2-pair UTP/STP Cat. 5 cable - EIA/TIA-568 100-ohm (100m); 1000BaseTX: UTP/STP Cat. 5/5E cable - EIA/TIA-568 100-ohm (100m) LED Indicator Per Unit: Housing Metal IP30 protection Dimension 46 x 142 x 99 mm (1.81 x 5.59 x 3.90 in.) Weight Unit Weight: 1.5 lbs. Shipping Weight: 2.3 lbs.