INSTALLATION LIGHTED MEDICINE CABINET Lighting and Defogger PRODUCT SERIES INFORMATION 20" 24" 30” W12MCL3030 36" 48" W12MCL3630 W12MCL4830 *WARNING: Do not remove corner proctors & paper cushions, please remove after installation. Please retain the cabinet accessories during the installation process for future needs, for example, screws, nuts, cap and other similar components.Requires three(3) person in installation. PAGE 1 *»Style and shape may vary from the picture above.
INSTALLATION LIGHTED MEDICINE CABINET Lighting and Defogger IMPORTANT SAFETY INSTRUCTIONS When using an electrical furnishing, basic precautions should always be followed,Requires three(3) person in installation. READ AND FOLLOW ALL INSTRUCTIONS | BEFORE USING THIS MIRROR CABINET DANGER WARNING To reduce the risk of burns, fire, electric shock or injury to persons. Use this furnishing only for its intended use as described in these instructions. Do not use attachments not recommended by the manufacturer.
INSTALLATION LIGHTED MEDICINE CABINET Lighting and Defogger ELECTRIC CONNECTIONS ALL WIRING SHOULD BE DONE BY A QUALIFIED LICENSED ELECTRICIAN > WARNING: shut off power before wiring the mirror. 5 WARNING: An Electrical option mirror must be wired to a 20 Amp GF (Ground Fault Interrupter) protected circuit when used in bathrooms and all other locations required by the National Electric Code. / \ WARNING: This mirror must be connected to a grounded, metal permanent wiring system or an equipment-grounding con
TOOLS REQUIRED FOR ASSEMBLY INSTALLATION LIGHTED MEDICINE CABINET Lighting and Defogger Electrical Drill FF 1/8” Drill Bit Pencil Phillips Screwdriver PARTS INCLUDED Tape Measure Level SCREW WALL PLUG BOTTOM TOP MOUNTING MOUNTING BRACKET BRACKET CABINET DOOR BUMPERS Requires three(3) person in installation. «Accessories and parts may vary from the picture above.Depends on the product model and size .
SURFACE-MOUNTED INSTALLATION * No need to take off the door(s) before installing the cabinets. Level and mark the cabinet's location on the wall. Mark the position of the Bottom Mounting Bracket and Punch. | NEC A f Bottom mounting brackets must be attached to furring strip/channel or wall studs i 3 | Punch holes in the mark, put in Wall Plug, fix With assistance, to rest the cabinet on the Bottom Mounting Bracket to the wall with Screw. mounting bracket and hold in place.
Insert top mounting bracket into the top of 6 | Make sure fop brackets are locked in the the cabinet. grooves. Adjust the position of Top Mounting Bracket 8 Remove the cabinet, drill holes according and mark the holes with a pencil to the marked position, and put in Wall Plugs. Put the cabinet down first, then drill the top bracket holes, electric drill bit _ vibrations will damage the cabinet top "surface.
SURFACE-MOUNTED INSTALLATION 9 Put the cabinet on the bottom mounting bracket Test the fit of the cabinet before Final assembly. and hold the place, then insert the top mounting bracket into the top of cabinet, fix the top mounting brackets to the holes with screw. (repeat step 4-6 ) NOTE: Vibrations occur in the electric drill, use Philips Screwdriver to protect your cabinet top surface. Top mounting brackets must attached to furring strip/channel or wall studs.
RECESS INSTALLATION * No need to take off the door(s) before installing the cabinets. Detach side panel connectors and EVA Refer to "dimensions" on page 4 to measure foam pads from the cabinet for recessed Rough in size. installation. These items are located on both sides of the mirror cabinet body. 2. [ Use a tool fo pry open + the round plastic cover. NOTE:To recess mount, the wall cavity must be framed and the cabinet secured to framing studs.
RECESS INSTALLATION Frame the opening for the cabinet based on the measurements. Cut out for wire pass Junction Box Electric supply wire Wire from medicine cabinet Connect electrical wires and then place the cabinet between the wall studs. Be Careful to avoid squeezing the wiring while insert the cabinet First cut off the power , then use the WIRE CONNECTOR connect to external power supply.
GLASS SHELF ADJUSTMENT * No need to take off the door(s) before adjusting cabinet shelves. 1. Insert the metal glass shelf clips into the shelf holes on both sides of the mirror cabinet. 2.Insert the Glass Shelf along the board clip slot. 3.Use a Phillips screwdriver to tighten the screw at the bottom of the metal shelf clip, securing and clamping the glass shelf in place. 1. Slide the doors into place by Press the end of the hinge to match Installing wiring terminals pinching the end of the hinges.
TOUCH BUTTON AND OUTLET CHARGER How to use Defogger Switch and Dimmer Switch : Left Touch Sensor (0 Short touch to turn ON/OFF the defogger. Middle Touch Sensor 5 [v] [2] Short touch to ON/OFF lighting. “Switch’sign Right Touch Sensor = Short touch to get the light temperature 6000K, 4000K and 3000K. = Long touch to adjust the light brightness from Release the button when the light reaches the desired setting.
USE AND MAINTENANCE WARNINGS: 1.Please do not use if you found the mirror cabinet has been broken. 2.Never put any sharp or heavy material on the mirror surface, other wise the glass mirror will be broken and body injury accidents may occur. 3.Turn off the power switch in storm lightning weather to avoid electric parts damage. Use and Maintenance: CAUTION: ® USE 1. To avoid damage, do NOT knock the mirror cabinet with any hard objects; 2. Do NOT clean the mirror cabinet with caustic cleaner.
LIMITED WARRANTY LIMITED WARRANTY TWO YEARS TERM: WELL FOR warrants to the original purchaser that, it will, at its election repair, replace, or make appropriate adjustment to products made by this company shown to have significant defects in material or workmanship which are reported to Wellington writing within two (2)years from the date of delivery. WELL FOR is not responsible for installation costs.