User Instructions

Installation Instruction
The Remote Unit, Extension Unit or Master Unit has to be
mounted by proffessionel / special trained installer.
1.1. MECHANICAL INSTALLATION
1.1.1. General
Read the health and safety warnings in section 1.3.
1. Do not install the unit in a way or at a place where the specifications outlined in the
Environmental and Safety Specifications leaflet of the supplier are not met.
2. It is recommended only to use the mounting hardware delivered by the supplier. If different
mounting hardware is used, the specifications for stationary use of the Remote Unit must not
be exceeded.
Note: Exceeding the specified load limits may cause the loss of warranty!
3. The unit is considerably heavy. Make sure that a suitable mounting surface is used. Ensure
there is adequate manpower to handle the weight of the system.
4. Due to power dissipation, the Remote Unit may reach a very high temperature. Ensure
sufficient airflow for ventilation as specified in the individual mounting procedures.
5. When connecting and mounting the cables (RF, optical, mains, ...) ensure no water can
penetrate into the unit through these cables.
6. Also observe all additional rules or restrictions regarding mounting that depend on the type of
Remote Unit. Install the unit vertically with the fan unit at the top. A maximum tilt angle of
25° from a vertical position must be kept, as in the following illustrations: