Installation Instruction

Installation Instruction
The Remote Unit, Extension Unit or Master Unit must be
mounted by proffessionel / special trained installer.
1.1. MECHANICAL INSTALLATION
1.1.1. Health and Safety for Mechanical Installation
1. Caution: Risk of injury by the considerable weight of the unit falling. Ensure there is
adequate manpower to handle the weight of the system.
2. Caution: Risk of serious personal injury by equipment falling due to improper installation.
The installer must verify that the supporting surface will safely support the combined load
of the electronic equipment and all attached hardware and components. The screws and
dowels (wall anchors) used should also be appropriate for the structure of the supporting
wall.
1.1.2. Property Damage Warnings for Mechanical Installation
1. Attention: Do not install the unit in a way or at a place where the specifications outlined in
the Environmental and Safety Specifications leaflet of the supplier are not met.
2. Attention: Due to power dissipation, the Remote Unit may reach a very high temperature.
Ensure sufficient airflow for ventilation.
3. Notice: Exceeding the specified load limits may cause the loss of warranty.
4. Notice: When connecting and mounting the cables (RF, optical, mains, ...) ensure that no
water can penetrate into the unit through these cables.
5. Notice: Also observe all additional rules or restrictions regarding mounting that depend on
the type of Remote Unit. For details refer to section 7.2.2 Mechanical Specification. Install
the unit vertically with the fan unit at the top. A maximum tilt angle of 25° from a vertical
position must be kept, as in the following illustrations: